IBM Systems & Technology Group Technical Conference 2008. Power = i + p. 2008 IBM Corporation



Documents pareils
Tout le monde parle du Cloud Computing, Mais qui offre une solution complète? Copyright IBM Corporation, 2009 All Rights Reserved

Convergence i & p : Une infrastructure fédératrice

vbladecenter S! tout-en-un en version SAN ou NAS

en version SAN ou NAS

GID SAS Aiguebelette, 12 juin 2013

Virtualisation des ressources serveur. Exemple : Systèmes partitionnés sous HP-UX et Oracle

L offre Stockage et serveurs System x / BladeCenter F.Libier, Business Partner Technical Manager

LES APPROCHES CONCRÈTES POUR LE DÉPLOIEMENT D INFRASTRUCTURES CLOUD AVEC HDS & VMWARE

VMware Infrastructure The New Computing Platform. Stéphane CROIX Systems Engineer

Windows Server Chapitre 1: Découvrir Windows Server 2008

StruxureWare Power Monitoring v7.0. La nouvelle génération en matière de logiciel de gestion complète d énergie

FOURNIR UN SERVICE DE BASE DE DONNÉES FLEXIBLE. Database as a Service (DBaaS)

HSCS 6.4 : mieux appréhender la gestion du stockage en environnement VMware et service de fichiers HNAS Laurent Bartoletti Product Marketing Manager

VMware : De la Virtualisation. au Cloud Computing

Bénéficiez d'un large choix d'applications novatrices et éprouvées basées sur les systèmes d'exploitation i5/os, Linux, AIX 5L et Microsoft Windows.

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

SAS AN Spécialiste en architecture de systèmes IBM POWER /AIX & Stockage PROFIL EXPÉRIENCE PROFESSIONNELLE

Engineered for Business: Oracle Hardware for Oracle Database

Replatforming SAP. Daniel MARTIN - Architecte SAP & Décisionnel Jean MIRANDA - Architecte Stockage & Messagerie. Espace Grande Arche Paris La Défense

APX et VCE, Modèle d industrialisation de l intégration et du déploiement. Olivier BERNARD, VCE

Les opportunités du modèle de Cloud Computing. Fabrice Dubosc

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

SERVEUR LYNX CALLEO DATACENTER 2460

ORACLE PAAS CLOUD MANAGEMENT

Serveur Lynx CALLEO Application 2240 Fiches Technique

Consolidation. Grid Infrastructure avec la 11gR2

SERVEUR CALLEO APPLICATION R269M

VMware ESX : Installation. Hervé Chaudret RSI - Délégation Centre Poitou-Charentes

Virtual I/O Server. ESCALA Power7 REFERENCE 86 F1 42FF 07

Présentation Infrastructure DATACENTRE

Positionnement PowerLinux

Webinar ORACLE LE LICENSING ORACLE Quel type de licensing choisir?

<Insert Picture Here> Exadata Storage Server et DB Machine V2

Le serveur IBM Power 750 Express offre la technologie IBM POWER7 et une capacité de calcul pour grande entreprise dans un format compact.

Virtualisation : explorez le champ des possibles avec VMware

ORACLE 10g Découvrez les nouveautés. Jeudi 17 Mars Séminaire DELL/INTEL/ORACLE

Une nouvelle Famille de systèmes

EXALOGIC ELASTIC CLOUD MANAGEMENT

Solutions Data Center. Bruno DUTRIAUX, Business Development, Data Center

Serveur Lynx CALLEO Application 2240S Fiches Technique

Choix d'un serveur. Choix 1 : HP ProLiant DL380 G7 Base - Xeon E GHz

Virtualisation des Serveurs et du Poste de Travail

..seulement 5% des serveurs x86 sont virtualisés!

Brochure de la gamme IBM System x

CA ARCserve Family of Solutions Pricing and Licensing

Organiser vos données - Big Data. Patrick Millart Senior Sales Consultant

Hitachi Storage Viewer v Hitachi Data Systems

PACKZ System Requirements. Version: Version: Copyright 2015, PACKZ Software GmbH. 1

imvision System Manager

Protection des données en environnement Windows

.Réinventons l innovation.

CATALOGUE DES OFFRES DE SERVICES IBM PARTENAIRES COMMERCIAUX DEMARRER

TRANSFORM IT + BUSINESS + YOURSELF


IBM Tivoli Monitoring, version 6.1

Modernisation et développement d applications IBM i Stratégies, technologies et outils. Volubis.fr

System Center 2012 R2 Licensing Fiche Produit

ADMINISTRATION EXADATA

file://\\tsclient\unix\msa.html

La Continuité d Activité

Cycle Innovation & Connaissance 12 petit déjeuner Mardi 15 mai Cloud Computing & Green IT : nuages ou éclaircies?

Un système intégré totalement redondant

IBM Power Systems GID SAS. Lyon, 4 Avril Didier FERAUD CTS Power Systems STG didier_feraud@fr.ibm.com IBM Corporation

Estimated SMB instances PC (Physical and Virtual) 125,000 Total instances: SMB 1-24 PC. 392,000 Total instances: SMB PC

La virtualisation du stockage

GESTION DU CYCLE DE VIE. Albert Amar Avant-vente Middleware

Cours 13. RAID et SAN. 2004, Marc-André Léger

Stratégie DataCenters Société Générale Enjeux, objectifs et rôle d un partenaire comme Data4

Serveur d E-S virtuel ESCALA REFERENCE 86 F1 81FA 01

Hyper-V v2 : une évolution majeure des services de virtualisation

TEC-SHEET. PROVIGO Dacoria V-STORAGE APPLIANCE. transtec Solution Data Sheet ADMINISTRATION MADE EASY HAUTE DISPONIBILITÉ MADE EASY

Fiche produit FUJITSU ETERNUS DX200F Baie de stockage Flash

Sébastien Geiger IPHC Strasbourg

IT SERVICES BUSINESS STORAGE DATA AUDIT PARTNERSHIP INTEGRATOR SECURITY PLANNING PRIVATE AGILITY DYNAMIC PUBLIC TECHNOLOGY SOLUTIONS MANAGEMENT

Technologie des disques SSD et IBM i

Gamme Serveurs HP ProLiant Rack

Sécurité de bout en bout Une solution complète pour protéger les données et prévenir les risques

Tivoli Storage Manager version TSM Server

Spécifications techniques

Configuration du serveur ESX

Spécifications détaillées

Spécifications détaillées

Plan de cette matinée

Entrer. Dans le Cloud

La Virtualisation Windows chez CASINO. Philippe CROUZY Responsable Infrastructure Equipes Systèmes -Stockage

SAN AoE (ATA over Ethernet)

High Performance IBM

Cartographie du SI pour alimenter la CMDB

Forward! 3.0. Antony Vo, Architecte Infrastructure SI, Unisys

Bienvenue au roadshow Microsoft System Center, SQL et Windows Server 2012

Innovative BI with SAP Jean-Michel JURBERT D. de Marché BI, HANA, BIG DATA _ SAP France

Hyper-V chez PSA. Stéphane CHOVET Spécialise Windows/Hyper-V

Virtualisation Infrastructure Agence

<Insert Picture Here> Solaris pour la base de donnés Oracle

Transcription:

Power = i + p

IBM Systems & Technology Group Technical Conference 2008 La gamme IBM Power Systems Common Features Processor technology Service Processor Virtualization 595 550 560 570 575 520 BladeCenter JS12 JS22

La transition vers la gamme Power Systems est achevée 1H2007 System p5-520q System p5-550q System p5 560Q System p5 570 1.65GHz 1.65GHz 1.8GHz 2.2 GHz rperf 20.3 38.3 75.6 95.9 System i 515/525 System i 550 System i 570 1.9GHz 1.9GHz 2.2 GHz cpw 7,100 14,000 58,500 4Q2008 Power 520 Power 550 Power 560 NEW! Power 570 4.2GHz 3.5/4.2 GHz 3.6GHz 5.0 GHz rperf 31.4 58.8/68.2 100.3 141.2 cpw 15,600 27,600/32,650 48,500 77,600 rperf, cpw data is located at http://www-03.ibm.com/systems/power/hardware/reports/system_perf.html 3

Lames BladeCenter Power Systems Blades Processeur # de processeurs (cores) GHz Mémoire (Min/Max) Disques internes (Min/Max) Ports Ethernet (1 GB) Slots cartes Virtualisation # de partitions (max) AIX Linux i Groupe Processeur CPW RPerf Disponibilité Support du Chassis BladeCenter JS12 POWER6 2 (1 socket DCM) 3.8 GHz 2/64 GB 0/2 73/146 GB 2 0-2 VIOS/IVM 20 Oui (5.3 & 6.1) Oui 6.1 P05 7100* 14.37 30 mai 2008 BCH, BCS JS22 POWER6 4 (2 sockets DCM) 4.0 GHz 2/32 GB 0/1 73/146 GB 2 0-2 VIOS/IVM 40 Oui (5.3 & 6.1) Oui 6.1 P10 13,800* 30.26 21 mars 2008 BCH, BCHT, BCS * Measurements based on an unconstrained environment. Actual performance may be limited by number of disk drives supported

Les chassis BladeCenter Chassis BCH BCS Exemples BladeS # de lames 14 6 # de disques Stockage externe 0 Bandes SAS DS 3400, DS4700, DS4800, DS8100, or DS8300 0-12 (SAS) Bandes SAS VIOS i Hypervisor JS12 / JS22 Capacité disque (Max) 0 3.6 TB Power Processeurs 220 x86 and POWER 110 ou 220 x86 and POWER VIOS i Hypervisor i Redundant Power and Cooling Management Modules Oui 1-2 Oui 1 JS12 / JS22 IBM i JS12 & JS22 JS12 et JS22 VIOS i AIX Linux Hypervisor JS12 / JS22

IBM Power 520 Express Configuration : 1, 2 ou 4-cores 4.2 GHz POWER6 Jusqu à 64 Go de mémoire Port Ethernet Quad 1 GB ou Dual 10 GB en option Disques SAS et slots PCI Express Format 4U Rack ou Tour AIX et Linux, et applications * Linux x86 PowerVM Express Edition en option Jusqu à 40 micro-partitions Jusqu à 8 tiroirs d Entrées/Sorties * PowerVM Lx86 feature supports most x86 applications, there are certain applications that will not run and not recommended. Go Green and Save with Ratio performance / watt amélioré de 36% par rapport au POWER5 QCM 3 Taux d utilisation améliorée grâce à la virtualisation PowerVM virtualization Gestion plus efficace des coûts énergétiques avec IBM Systems Director Active Energy Manager Pour quels besoins? Applications : ERP, CRM, petites databases Serveur transactionnel ecommerce or Java Petit serveur de Consolidation

IBM Power 550 Express Configuration : 2, 4, 6 ou 8-cores 3.5 Ghz ou 4.2 GHz POWER6 Jusqu à 256 Go de mémoire Port Ethernet Quad 1 GB ou Dual 10 GB en option Disques SAS et slots PCI Express Format 4U Rack ou Tour AIX et Linux, et applications * Linux x86 PowerVM Express Edition en option Jusqu à 80 micro-partitions Jusqu à 8 tiroirs d Entrées/Sorties Go Green and Save with Taux d utilisation améliorée grâce à la virtualisation PowerVM virtualization Gestion plus efficace des coûts énergétiques avec IBM Systems Director Active Energy Manager * PowerVM Lx86 feature supports most x86 applications, there are certain applications that will not run and not recommended. Pour quels besoins? Serveur de bases de données DB2, Oracle ou Sybase Serveur mono ou multi-applications ERP ou CRM Serveur de Consolidation

Power 560 Express Serveur d infrastructure, applicatif et de consolidation Permet de réduire et de contrôler la consommation énergétique, l occupation au sol, et les coûts logiciels appliqués par coeur Rapport prix/performance aggressif 2 tiroirs modulaires, technologie idéale pour les grosses PME et les entités informatiques éparpillées 3.6 GHz POWER6 processors 4, 8, and 16 core Express configurations AIX, i, and Linux Operating System POWER6 Processors L3 Cache Redundant Power & Cooling 32 MB / Chip Yes 3.6 GHz Redundant Server Processor Optional ( Two Nodes minimum ) Redundant Clock Yes (Cold Detect) ( Two Nodes minimum ) Advanced Features: CUoD, Hot Node Add, Concurrent Repair Per Building Block Cores 4 or 8 16 DDR2 Memory (Buffered) 192 384 SAS Disk Bays (3.5 ) 6 12 No System Maximum Media Bays 1 Slim-line 2 Slim-line SAS/SATA Controller 1 2 PCI (Internal) 4 PCIe, 2 PCI-X 266 8 PCIe, 4 PCI-X 266 GX Bus Slots 2 3 Dual Port 10/100/1000 Quad Port 1 Gb (Optional) 1 2 Dual Port 10 Gb (Optional Remote I/O Drawers 8 Max 12 Max Dynamic LPARs 80 160 8

Power 570/16 POWER6 Processors L3 Cache Redundant Power & Cooling 3.5, 4.2 et 4.7 GHz 4.4 and 5.0 GHz 32 MB / Chip Yes Redundant Server Processor Optional ( Two Nodes minimum ) Redundant Clock Yes (Cold Detect) ( Two Nodes minimum ) CoD Yes Hot Node Add Yes Hot-node Repair Yes ( Nodes 2 / 3 / 4 ) Per Building Block System Maximum Cores 4 16 DDR2 Memory (Buffered) 2-192 768 SAS Disk Bays (3.5 ) 6 24 Media Bays 1 Slim-line 4 Slim-line SAS/SATA Controller 1 4 PCI (Internal) 4 PCIe, 2 PCI-X 266 16 PCIe, 8 PCI-X 266 GX Bus Slots 2 8 Dual Port 10/100/1000 Quad Port 1 Gb (Optional) 1 4 Dual Port 10 Gb (Optional) Remote I/O Drawers 8 Max 32 Max Dynamic LPARs 40 160

Power 570/32 POWER6 Processors 4.2 GHz L3 Cache 32 MB / Chip Redundant Power & Cooling Yes Redundant Server Processor Optional ( Two Nodes minimum ) Redundant Clock Yes (Cold Detect) ( Two Nodes minimum ) CoD Hot Node Add Yes Yes Hot-node Repair Yes ( Nodes 2 / 3 / 4 ) Per Building Block System Maximum Cores 8 32 DDR2 Memory (Buffered) 2-192 768 SAS Disk Bays (3.5 ) 6 24 Media Bays 1 Slim-line 4 Slim-line SAS/SATA Controller 1 4 PCI (Internal) 4 PCIe, 2 PCI-X 266 16 PCIe, 8 PCI-X 266 GX Bus Slots 2 8 Dual Port 10/100/1000 Quad Port 1 Gb (Optional) Dual Port 10 Gb (Optional) 1 4 Remote I/O Drawers 8 Max 32 Max Dynamic LPARs 80 160

Positionnement Power TM Systems Entrée/Milieu de gamme Footprint, packaging Nodes Number of SMPs GHz clock Max. GB of Memory Max. Internal Storage PCI slots LPARs I/O Drawers Advanced Features Primary Use rperf cpw p5-560q NEW! Power 520 Power 550 Power 560 EOL 1Q09 4RU rack, tower 31 1 1, 2, 4 4.2 64GB 1.8TB 5 40 8 No Distributed application server 15,600 4RU rack, tower 1 2, 4, 6, 8 3.5/4.2 128/256GB 1.8TB 5 80 8 No Mid-size DB server, application consolidation server 68.2 32,650 2 nodes x 4RU 2 4, 8, 16 1.8 128GB 3.6TB 12 160 8 No Application server consolidation, database server 75.6 N/A 2 nodes x 4RU 2 4, 8, 16 3.6 384GB 5.4TB 12 160 12 No Application server consolidation, database server 100.3 48,500 Power 570 4 nodes x 4RU 2, 4, 8, 12, 16, 32 3.5, 4.2, 4.7 4.4, 5.0, 4.2(32) 768GB 10.2TB 24 160 48 Yes Database server, large scale consolidation server 141.2 77,600 rperf data is located at http://www-03.ibm.com/systems/power/hardware/reports/system_perf.html

POWER6 continues to deliver more Performance per Watt 9X increase in performance per watt 7.9X increase in rperf performance 7+ years of changing the UNIX landscape rperf per KWatt POWER4 p670 1.1 GHz rperf: 24.46 KWatts: 6.71 POWER4+ p670 1.5 GHz rperf: 46.79 KWatts: 6.71 POWER5 p5-570 1.65 GHz rperf: 68.4 KWatts: 5.2 POWER5+ p570 1.9 GHz rperf: 85.20 KWatts: 5.2 POWER6 Power 570 4.7 GHz rperf: 134.35 KWatts: 5.6 POWER6 Power 570 4.2 GHz rperf: 193.25 KWatts: 5.6

Power 595 De 8 à 64 cores POWER6 cadencés à 5.0 et 4.2 GHz Mémoire jusqu à 4 TB avec plus de bande passante (1.3 TB/sec) Interconnection point-to-point SMP pour une scalabilité linéaire Améliorations pour une disponibilité continue Serveur de consolidation par excellence pour des applications UNIX, i et Linux Performance leadership Performance + Disponibilité Meilleur taux d utilisation (TCO) Meilleur efficience énergétique

IBM Power 595 Les nouveautés annoncées ce trimestre améliore la résilience et le rapport prix/performance de votre infrastructure Fonctions Hot-node Add & Hot-node Repair : ajoutez et modifiez des ressources sans interruption de service Ajout de books processeurs Réparation/modification de books processeurs ayant des composants corrompus Ajout de mémoire sur des books existants Nouveaux tiroirs I/O12X pour augmenter la bande passant I/O Ils remplacent les tiroirs RIO-2 I/O ou peuvent coexister avec eux Nouveaux books processeurs 5 GHz permettant l exploitation de mémoires 64GB DDR2 New features are available on November 21 with the latest release of firmware

IBM Power Systems High End Positioning 570/16 570/32 595 Nodes 4 nodes of 4 cores each 4 nodes of 8 cores each 8 nodes of 8 cores each Processors 2 16 4 32 8 64 Frequency 3.5-5.0 GHz 4.2 GHz 4.2, 5.0 GHz System memory 768 GB 768 GB 4 TB Memory per core 48 GB 24 GB 64 GB Memory Bandwidth 256 GB/s 256 GB/s 1376 GB/s I/O Bandwidth 66.7 GB/s 56 GB/s 640 GB/s 16 core rperf 122.67 @ 4.2 GHz 142.90 @ 4.2 GHz 127.32 @ 4.4 GHz 113.68 @ 4.2 GHz 164.67 @ 5.0 GHz 141.21 @ 5.0 GHz Maximum CPW 77,600 @ 5.0 GHz 104,800 @ 4.2 GHz 294,700 @ 5.0 GHz rperf per core 7.6-8.8 7.1 8.9-10.2 rperf per kw 21.9-25.2 40.6 21.9 23.4 rperf per U 7.6-8.8 14.21 RAS Concurrent, dynamic clocks Hot-node Repair on all nodes Warranty 9 x 5 9 x 5 24 x 7 PowerCare No No Yes

Power = Uptime + Control Standard Optional Not available RAS Item Power 550 Power 560 Power 570 Power 595 Redundant / Hot Swap Fans & Blowers Hot Swap DASD / Media / PCI Adapters Concurrent Firmware Update Redundant / Hot Swap Power Supplies Dual disk controllers (split backplane) Processor Instruction Retry / Alternate Processor Recovery Storage Keys PowerVM /Live Partition Mobility/Live Application Mobility Redundant Service Processors * * Redundant System Clocks * * Redundant / Hot Swap Power Regulators Dynamic Processor Sparing Memory Sparing Hot GX Adapter Add and Cold Repair Hot-node Add / Cold-node Repair * Hot-node Repair / Hot-memory Add * * POWER6 Enhanced Memory Dynamic System Clock Failover Hot-node Repair / Hot-memory Add for all nodes * Mid-plane connection for inter-nodal communication * Requires two or more nodes

AIX système d exploitation le plus Fiable D après une étude récente du Yankee Group study* auprès de 400 utilisateurs Windows, Linux et UNIX, AIX est le système d exploitation le plus fiable: IBM s AIX achieved the highest level of reliability, with corporate enterprises reporting an average of only 36 minutes of downtime per server in a 12-month period 9 8 7 6 5 4 3 2 1 0 Hours of downtime per year* AIX HP-UX Solaris Windows * Source: Unix, Linux Uptime and Reliability Increase; Patch Management Woes Plague Windows 2008 Yankee Group Research, Inc. All rights reserved 17

Capacity on Demand : Payez pour la capacité dont vous avez besoin et économisez de l énergie sur les processeurs inutilisés! Réponse instantanée aux besoins de capacité Et payez seulement aux minutes consommées! Supporté Plus d information et CoD Planning Guide: Non disponible http://www.ibm.com/systems/support/planning/capacity/index.html Power 595&570 Offre Processeur Mémoire Pre- Pay Post- Pay Usage Capacity Upgrade on Demand Upgrades non disruptifs Trial Capacity on Demand Test de capacité additionnelle, Test de nouvelles applis/workloads On/Off Capacity on Demand Satisfaire des demandes saisonnières (granularité à la journée) New! Utility Capacity on Demand Satisfaire des pics de charge courts et non prédictifs avec un haut niveau de service (granularité à la minute)

IBM et la virtualisation Une histoire vieille de 40 ans jusqu à. PowerVM 1967 1973 1987 1999 2004 2007 2008 IBM développe l hyperviseur qui deviendra VM sur les mainframes IBM annonce les premiers serveurs qui supportent le partitionnement physique IBM annonce LPAR sur les mainframes IBM annonce LPAR sur POWER IBM introduit l Hyperviseur POWER pour les System p et System i IBM annonce POWER6, le 1er serveur UNIX avec Live Partition Mobility IBM annonce PowerVM [PowerVM] ensures that we are making the best possible use of hardware resources across our entire environment. - T N Rangarajan, VP of IT, Brakes India August 2007 client quote source: Brakes India case study published at http://www.ibm.com/software/success/cssdb.nsf/cs/strd-76dhwe?opendocument&site=eserverpseries&cty=en_us

Editions PowerVM Virtualisation pour UNIX, Linux et IBM i PowerVM Editions Quoi de neuf? Express Standard Enterprise Essayez à moindre coût la virtualisation sur plateforme Power avec PowerVM Express Edition Servers Supported p520, p550 JS21, JS22, System i, System p & Power Systems JS22, Power Systems Hébergez et consolidez vos applications x86 Linux sur Power sans recompilation, avec Lx86 Maximum LPARs Management Virtual I/O Server 3 / Server IVM 10 / Core IVM, HMC 10 / Core IVM, HMC Support de Virtual I/O server pour IBM i V6R1 Lx86 Shared Dedicated Capacity* PowerVM Express Multiple Shared Processor Pools Power Systems * Power Systems * 26,88 / core SWMA 1 an : 8,96 / core SWMA 3 ans : 24,19 / core Live Partition Mobility Multiple Shared Processor Pools supporté sur plateforme POWER6, avec HMC Live Partition Mobility fonctionne avec AIX V5.3 ou supérieur et Linux on POWER * Serveurs avec processeurs POWER6 uniquement

PowerVM Shared Dedicated Capacity Permet à une partition à processeurs dédiés de céder des ressources processeurs non utilisées 200 175 150 125 100 75 50 0.5 Nonbridée 2 0.5 Nonbridée 1 Puissance perdue 1 Core Dédié 25 0 1 partition avec un processeur dédié 2 partitions qui se partagent un processeur.

PowerVM Shared Dedicated Capacity 200 175 150 125 100 75 50 0.5 Nonbridée 2 0.5 Nonbridée 1 Puissance perdue 1 Core Dédié 25 0 Avec la fonction Shared Dedicated, une partition à processeurs dédiés va donner son excès de cycles processeur aux partitions non-bridées qui en font la demande. Chaque partition non-bridée (uncapped) va consommer un processeur entier s il est disponible (quand la partition dédiée est à 0%) et partagera un processeur quand la partition à processeurs dédiés sera à pleine charge (100%) La capacité totale des ressources processeur du système est mieux utilisée tandis que la partition à processeurs dédiés conserve les caractéristiques de performance et de prévisibilité des environnements dédiés lors des fortes charges.

PowerVM Lx86 Pouvoir faire tourner des applications Linux x86 sur des serveurs Power en même temps que des applications UNIX ou Linux on POWER. Simplifie la migration d applications Linux x86, tout en tirant partie de la valeur ajoutée des serveurs IBM Power Systems en terme d économie d énergie et de facilité d administration apportées par la consolidation : Exécution de la plupart des applications Linux 32-bit x86 sans modification Inclus dans l achat des éditions PowerVM Editions x86 x86 x86 Linux OS Linux OS Linux OS App App App Linux OS Linux OS Linux OS x86 Platforms x86 Platforms x86 Platforms Install and Run Sans portage Sans recompilation Sans modification GA : 8 février 2008 x86 Linux OS App PowerVM Lx86 POWER Linux OS Application Supported Linux OS PowerVM AIX OS Application AIX OS Power Systems Platform

PowerVM Live Partition Mobility Déplacer des partitions Unix et Linux actives d un serveur à base de processeurs POWER6 à un autre! Disponibilité continue : éliminer la plupart des arrêts planifiés Workload Balancing: pendant les pics de charge Economie d énergie : pendant les heures creuses Infrastructure Infrastructure SAN SAN et et Réseau Réseauvirtualisée

PowerVM Workload Partition & PowerVM Live Application Mobility (AIX 6.1) AIX Image 1 AIX Image 2 Workload Partition A Workload Partition C Workload Partition E Application Partition D Workload Partition B Workload Partition Q Workload Partition R Workload Partition S Partitionnement logiciel : partition logique dans une instance AIX Gestion des contrôles séparée : domaine de sécurité & administration Ressoures partagées : Operating system, E/S, processeur & mémoire Déplacement d une partition logique, dans une instance AIX 6, d un serveur à un autre pour éviter les arrêts systèmes et/ou permettre une répartition de charge multi-serveurs Fonctionne sur les serveurs supportant AIX 6 : POWER4, POWER5/5+ et POWER6

Integrated Virtualization Manager Une solution adaptée aux collectivités locales Simplification de la gestion Interface graphique (Navigateur) pour créer et gérer les partitions Réduction des coûts Plus besoin d une HMC dédiée Inclus dans toutes les éditions PowerVM Fait partie de la partition Virtual I/O Server

IBM Systems Director for POWER Plus de virtualisation, moins de management Standard avec les Power 550, Power 520 et BladeCenter JS12 & JS22 Réduit les taches d administration consommatrices de temps en simplifiant le management des ressources physiques et virtuelles Déploiement et configuration du logiciel simple Suivi du bon fonctionnement du système en continu Manangement proactif de l énergie Suivi de l utilisation et comptabilité Supports de tous les systèmes incluant les System p, System i, System x, BladeCenter et stockage IBM System Storage Nouveautés Power Systems - Interface intuitive avec page d accueil pour les serveurs Power Systems - Amélioration des fonctionnalités de découverte et des vues graphiques des ressources et de leurs interactions - Administration AIX et i intégrées, updates software/firmware pour les serveurs Power Systems et les Hardware Management Consoles (HMC)

Go green and save energy avec IBM EnergyScale technology Piloter vos coûts énergétiques.. New! IBM Systems Director Active Energy Manager exploite la technologie EnergyScale pour vous aider à réduire votre consommation énergétique Mesures Consommation/thermiques : Collecte et remonte la consommation énergétique et ses tendances, et les données thermiques des systèmes Nap Mode: Alimentation des processeurs inactifs coupée et restaurée quand les besoins de performance le nécessite Limitation énergétique : Contrôle précis pour garantir que le système ne dépasse pas un seuil de consommation défini Economie d énergie : Fonctionnement avec consommation limitée lorsque les workloads le permettent IBM Confidential until Announce IBM Systems Director Active Energy Manager V4.1 Nouveautés Power Systems - Nouvelles fonctionnalités de contrôle énergétique pour fixer des limites sur un serveur ou sur un groupe de serveurs - Modes de contrôles énergétiques pour favoriser économies vs. performances - Ajustement de la vitesse de ventilateur(s) - Monitoring de données environnementales (e.g. A/C units, legacy hardware) d applications de facility management et de capteurs wi-fi Chassi BladeCenter IBM Power 520 et Power 550 IBM Power 570