ABB Inc. 7051 Industrial Blvd. Bartlesville, OK, 74006 USA. ABB Inc. 7051 Industrial Blvd. Bartlesville, OK, 74006 USA



Documents pareils
Maximum Capacity / Capacité maximal: 10 kg/min

Daniel Industries Canada Inc. A Division of Emerson Process Management nd Avenue SE Calgary, Alberta T2C 2G5

Schneider Electric 19 Waterman Ave. Toronto, Ontario M4B 1Y2. Square D/Schneider Electric 295 Tech Park Drive LaVergne, TN USA

Metretek Incorporated 305 East Drive, Suite A Melbourne, Florida, USA

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

Paxton. ins Net2 desktop reader USB

Kraft Fuels/Alternate Fuels Technology Inc. 50 Ritin Lane, Unit 20 Concord, Ontario L4K 4C9

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Embases pour raccordement G1/8 - G1/4

Fisher Controls International Inc South 17th Avenue Marshalltown, IA, USA

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

Chromatographe NGC8206 Manuel d utilisation

(FRENCH) NGC8200 Start-Up Guide. Propriété intellectuelle et Droits d auteur. Introduction. Avant de commencer

Credit Note and Debit Note Information (GST/ HST) Regulations

Règlement relatif à l examen fait conformément à la Déclaration canadienne des droits. Canadian Bill of Rights Examination Regulations CODIFICATION

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Material Banking Group Percentage Regulations. Règlement fixant le pourcentage (groupe bancaire important) CONSOLIDATION CODIFICATION

Interest Rate for Customs Purposes Regulations. Règlement sur le taux d intérêt aux fins des douanes CONSOLIDATION CODIFICATION

Notice Technique / Technical Manual

F1 Security Requirement Check List (SRCL)

Short-term Pooled Investment Fund Regulations. Règlement sur le fonds commun de placement à court terme CONSOLIDATION CODIFICATION

Form of Deeds Relating to Certain Successions of Cree and Naskapi Beneficiaries Regulations

Nordion Europe S.A. Incorporation Authorization Order. Décret autorisant la constitution de Nordion Europe S.A. CONSOLIDATION CODIFICATION

Calculation of Interest Regulations. Règlement sur le calcul des intérêts CONSOLIDATION CODIFICATION. Current to August 4, 2015 À jour au 4 août 2015

Railway Operating Certificate Regulations. Règlement sur les certificats d exploitation de chemin de fer CODIFICATION CONSOLIDATION

Loi sur l aide financière à la Banque Commerciale du Canada. Canadian Commercial Bank Financial Assistance Act CODIFICATION CONSOLIDATION

Ships Elevator Regulations. Règlement sur les ascenseurs de navires CODIFICATION CONSOLIDATION. C.R.C., c C.R.C., ch. 1482

Order Binding Certain Agents of Her Majesty for the Purposes of Part 1 of the Personal Information Protection and Electronic Documents Act

Archived Content. Contenu archivé

Appointment or Deployment of Alternates Regulations. Règlement sur la nomination ou la mutation de remplaçants CONSOLIDATION CODIFICATION

If the corporation is or intends to become a registered charity as defined in the Income Tax Act, a copy of these documents must be sent to:

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

Avis certifiant que des pays accordent les avantages du droit d auteur. Certification of Countries Granting Equal Copyright Protection Notice

Disclosure on Account Opening by Telephone Request (Trust and Loan Companies) Regulations

de stabilisation financière

Itron Canada Inc. 6507C Mississauga Road Mississauga, Ontario L5N 1A6. Itron B North Highway 11 West Union, South Carolina, USA

Life Companies Borrowing Regulations. Règlement sur les emprunts des sociétés d assurance-vie CONSOLIDATION CODIFICATION

Règlement sur les baux visés à la Loi no 1 de 1977 portant affectation de crédits. Appropriation Act No. 1, 1977, Leasing Regulations CODIFICATION

Z-Axis Compliance Device Compliance en z

Instructions Mozilla Thunderbird Page 1

Borrowing (Property and Casualty Companies and Marine Companies) Regulations

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

APPENDIX 6 BONUS RING FORMAT

THE LAW SOCIETY OF UPPER CANADA BY-LAW 19 [HANDLING OF MONEY AND OTHER PROPERTY] MOTION TO BE MOVED AT THE MEETING OF CONVOCATION ON JANUARY 24, 2002

General Import Permit No. 13 Beef and Veal for Personal Use. Licence générale d importation n O 13 bœuf et veau pour usage personnel CONSOLIDATION

Practice Direction. Class Proceedings

BILL 203 PROJET DE LOI 203

Air Transportation Tax Order, Décret de 1995 sur la taxe de transport aérien CONSOLIDATION CODIFICATION

Disclosure on Account Opening by Telephone Request (Retail Associations) Regulations

Mercury Instruments Inc Virginia Avenue Cincinnati, Ohio, USA Mercury Instruments Inc Virginia Avenue Cincinnati, Ohio, USA 45227

Export Permit (Steel Monitoring) Regulations. Règlement sur les licences d exportation (surveillance de l acier) CONSOLIDATION CODIFICATION

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

Order Assigning to the Minister of the Environment, the Administration, Management and Control of Certain Public Lands

Fabricant. 2 terminals

Resident Canadian (Insurance Companies) Regulations. Règlement sur les résidents canadiens (sociétés d assurances) CONSOLIDATION CODIFICATION

Daniel Industries Canada Inc nd Avenue S.E. P.O. Box 727, Station T Calgary, AB T2H 2H2

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

CONSOLIDATION CODIFICATION. Current to August 30, 2015 À jour au 30 août 2015

Exercices sur SQL server 2000

Name Use (Affiliates of Banks or Bank Holding Companies) Regulations

INDIVIDUALS AND LEGAL ENTITIES: If the dividends have not been paid yet, you may be eligible for the simplified procedure.

CODIFICATION CONSOLIDATION. Current to August 30, À jour au 30 août Last amended on December 12, 2013

TERRITOIRES DU NORD-OUEST RÈGLEMENT SUR LA FORMULE DE NOTIFICATION R FORM OF NOTIFICATION REGULATIONS R

Contrôle d'accès Access control. Notice technique / Technical Manual

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

LOI SUR LA RECONNAISSANCE DE L'ADOPTION SELON LES COUTUMES AUTOCHTONES ABORIGINAL CUSTOM ADOPTION RECOGNITION ACT

WEB page builder and server for SCADA applications usable from a WEB navigator

DOCUMENTATION - FRANCAIS... 2

Mon Service Public - Case study and Mapping to SAML/Liberty specifications. Gaël Gourmelen - France Telecom 23/04/2007

CLIM/GTP/27/8 ANNEX III/ANNEXE III. Category 1 New indications/ 1 re catégorie Nouvelles indications

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Monitor LRD. Table des matières

LE FORMAT DES RAPPORTS DU PERSONNEL DES COMMISSIONS DE DISTRICT D AMENAGEMENT FORMAT OF DISTRICT PLANNING COMMISSION STAFF REPORTS

Package Contents. System Requirements. Before You Begin

Critères à l attention des fabricants et des fournisseurs de biens ou de services : dispositifs mécaniques pour bingo

Input Tax Credit Information (GST/HST) Regulations

FÉDÉRATION INTERNATIONALE DE NATATION Diving

Import Allocation Regulations. Règlement sur les autorisations d importation CONSOLIDATION CODIFICATION

Once the installation is complete, you can delete the temporary Zip files..

AIDE FINANCIÈRE POUR ATHLÈTES FINANCIAL ASSISTANCE FOR ATHLETES

86 rue Julie, Ormstown, Quebec J0S 1K0

Ordonnance sur le paiement à un enfant ou à une personne qui n est pas saine d esprit. Infant or Person of Unsound Mind Payment Order CODIFICATION

Folio Case User s Guide

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

CLASSIFICATION REPORT OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2007

Edna Ekhivalak Elias Commissioner of Nunavut Commissaire du Nunavut

Application Form/ Formulaire de demande

An Act to Amend the Tobacco Sales Act. Loi modifiant la Loi sur les ventes de tabac CHAPTER 46 CHAPITRE 46

PART II / PARTIE II Volume 31, No. 11 / Volume 31, n o 11

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

Contents Windows

Fédération Internationale de Handball. b) Règlement du but

AUDIT COMMITTEE: TERMS OF REFERENCE

Supervision et infrastructure - Accès aux applications JAVA. Document FAQ. Page: 1 / 9 Dernière mise à jour: 15/04/12 16:14

Transcription:

Measurement Canada An Agency of Industry Canada Un organisme d Industrie Canada APPROVAL No. - N D APPROBATION Mesures Canada NOTICE OF APPROVAL Issued by statutory authority of the Minister of Industry for: AVIS D APPROBATION Émis en vertu du pouvoir statutaire du ministre de l Industrie pour : TYPE OF DEVICE Gas Chromatograph APPLICANT TYPE D APPAREIL Chromatographe en phase gazeuse REQUÉRANT ABB Inc. 7051 Industrial Blvd. Bartlesville, OK, 74006 USA MANUFACTURER FABRICANT ABB Inc. 7051 Industrial Blvd. Bartlesville, OK, 74006 USA MODEL(S)/MODÈLE(S) 8209 RATING/ CLASSEMENT -18 C to +55 C / de -18 C à +55 C Page 1 of/de 12

NOTE: This approval applies only to meters, the design, composition, construction and performance of which are, in every material respect, identical to that described in the material submitted, and that are typified by samples submitted by the applicant for evaluation for approval in accordance with sections 13 and 14 of the Electricity and Gas Inspection Regulations. The following is a summary of the principal features only. SUMMARY DESCRIPTION: The NGC 3809 is an on-line chromatograph which consists of an oven that houses sample valves, chromatographic columns and thermal conductivity detectors. The device performs an extended analysis of natural gas. A single controller processes the data, calculating heating value, compressibility and other necessary calculations. A natural gas sample is extracted from a flowing pipeline, transported to the analyzer and processed for particle removal. The sample is then injected onto the main and secondary unit for separation and analysis. The main unit has 2 columns and measures: N2 (nitrogen), CO2 (Carbon Dioxide), C1 (Methane), C2 (Ethane), C3 (Propane), IC4 (ISO-Butane), NC4 (N- Butane), NeoC5 (Neo-Pentane), IC5 (ISO-Pentane), NC5 (N-Pentane), C6 (Hexane). The secondary unit has 1 column and measures: C7 (Heptanes), C8 (Octanes), C9 (N-Nonane). From these concentrations the heating value and compressibility are calculated. REMARQUE : La présente approbation ne vise que les compteurs dont la conception, la composition, la construction et le rendement sont identiques, en tout point, à ceux qui sont décrits dans la documentation reçue et pour lesquels des échantillons représentatifs ont été fournis par le requérant aux fins d évaluation, conformément aux articles 13 et 14 du Règlement sur l inspection de l électricité et du gaz. Ce qui suit est une brève description de leurs principales caractéristiques. DESCRIPTION SOMMAIRE : Le NGC 3809 est un chromatographe en ligne constitué d un four dans lequel se trouvent les vannes d échantillonnage, les colonnes chromatographiques et les catharomètres. L appareil effectue une analyse précise du gaz naturel. Un régulateur unique traite les données; il calcule le pouvoir calorifique et la compressibilité et effectue les autres calculs nécessaires. Un échantillon de gaz naturel est prélevé d un gazoduc, acheminé vers l analyseur et traité pour en extraire les particules. Ensuite, l échantillon est injecté dans les unités principale et secondaire, où il sera séparé et analysé. L unité principale compte deux colonnes et mesure le N 2 (azote), le CO 2 (dioxyde de carbone), le C 1 (méthane), le C 2 (éthane), le C 3 (propane), l IC 4 (isobutane), le NC 4 (n-butane), le NeoC 5 (néopentane), l IC 5 (isopentane), le NC 5 (n-pentane) et le C 6 (hexane). L unité secondaire est constituée d une colonne et mesure le C 7 (heptane), le C 8 (octane) et le C 9 (n-nonane). Le pouvoir calorifique et la compressibilité sont calculés à partir de ces concentrations. Page 2 of/de 12

Calculated values include: - Real Relative Density (Specific Gravity) - Btu/CV Value - Wobbe Index All of these values as well as composition are available on a modbus communication protocol. The sample is then vented and results are stored in memory and communicated to other devices as needed. Functional setup and operation of the Btu/CV Transmitter is accomplished by using Portable Collection and Calibration Unit (PCCU) software operating on a Laptop PC in a Windows environment. Les valeurs calculées comprennent : - la densité relative réelle (gravité spécifique) - la valeur Btu/VC - l indice de Wobbe Toutes ces valeurs, ainsi que la composition sont accessibles au moyen d un protocole de communication Modbus. L échantillon est ensuite mis à l air libre et les résultats sont entreposés en mémoire et communiqués aux autres appareils au fur et à mesure des besoins. La configuration fonctionnelle et l exploitation du transmetteur Btu/VC se font au moyen du logiciel Portable Collection and Calibration Unit (PCCU) installé sur un ordinateur portatif dans un environnement Windows. Page 3 of/de 12

COMPONENTS: Feed-through Assembly: Independant sample streams are connected directly to the Feed-through Assembly of the 8209 main and secondary unit, or an optionally installed Sample Conditioning System. The Feed-through Assemblies also serve as the connection for the carrier gas and calibration streams, and contains the vents for the sample and the column gases. Analytical Module: This applies to the main and secondary unit of the 8209. This module can be broken down into three components: the GC Module, the Manifold Assembly and the Analytical Processor Assembly. The GC Module is comprised of 3 parts: valves, columns and electronic interface. The valves control flow of gas within the system. The columns perform the separation of the gas into component parts for analysis. The electronic interface contains pressure and temperature sensors to monitor and detect the different gas components as they leave the GC columns. The analytical processor board interfaces with the analogue circuits to monitor temperatures and pressures, and also controls the processes. The 8209 is equipped with a manifold heater that is set to 10 C. This heater is automatically turned on when the temperature lowers under the set temperature. It is used to maintain a warmer temperature in the manifold in order to assure reliable data analysis. COMPOSANTS : Ensemble de traversée : Des circuits d échantillonnage indépendants sont raccordés directement à l ensemble de traversée des unités principale et secondaire du 8209 ou à un système de conditionnement d échantillon installé en option. L ensemble de traversée sert également de raccord pour le gaz vecteur et les circuits d étalonnage et contient les évents pour l échantillon et les gaz dans les colonnes. Module analytique : Il se trouve dans les unités principale et secondaire du 8209. Ce module compte trois composants : le module de chromatographie en phase gazeuse (CPG), le collecteur et le processeur analytique. Le module de CPG comprend trois parties : les vannes, les colonnes et l interface électronique. Les vannes commandent l écoulement du gaz dans le système. Les colonnes séparent le gaz en composants aux fins d analyse. L interface électronique comprend les capteurs de pression et de température qui surveillent et détectent les différents composants du gaz à la sortie des colonnes du CPG. La carte du processeur analytique est branchée aux circuits analogiques; elle surveille la température et la pression et commande les processus. Le modèle 8209 est équipé d un élément chauffant du collecteur réglé à 10 C. Cet élément chauffant s allume automatiquement si la température descend sous la température de consigne. Cet élément chauffant est utilisé pour conserver une température plus élevée dans le collecteur afin d assurer une analyse des données fiable. Page 4 of/de 12

SPECIFICATIONS Detector Type: Two Thermal Conductivity Detectors. This applies to the main and secondary unit. Sampling Freq.: 40 Hz Column information: The Gas valve (Part number 2103180-xxx for the main unit, (Part number 2103220-xxx for the secondary unit) contains the columns which are encased and therefore not accessible. The valve part number and revision level (001) ensure that the columns are the same as tested. If the columns change the revision will be different. - Software Name: PCCU NGC (Portable Collection and Calibration Unit) - Firmware Version: Accountable Software: CHROM PROCESSOR, part number 2103505-002, ANALYZER STREAM, part number 2101312-001. APPROVAL No. - N D APPROBATION CARACTÉRISTIQUES Type de détecteur : Deux détecteurs à thermo-conduction dans les unités principale et secondaire. Fréquence d échantillonnage : 40 Hz Information relative aux colonnes : Les vannes (pièce n o 2103180-xxx pour l unité principale, pièce n o 2103220-xxx pour l unité secondaire) comprennent les colonnes, qui sont enfermées, donc inaccessibles. Les numéros de pièce et de révision (001) des vannes garantissent que les colonnes sont les mêmes que celles qui ont été mises à l essai. Si les colonnes changent, le numéro de révision sera différent. - Nom du logiciel : PCCU NGC (Portable Collection and Calibration Unit). - Version du micrologiciel : logiciel principal : CHROM PROCESSOR, numéro de pièce 2103505-002, ANALYZER STREAM, numéro de pièce 2101312-001. The Software information is available through the Help menu, select About. The firmware information is available from the Main screen, press the Connect button, then select the Entry Setup. In the tree view select TOTALFLOW (or whichever name was given as the station id) which is at the top level of the tree. Then select the Registry tab. The Crom Processor and the Analyzer Stream part numbers contain the metrologically significant information. L information concernant le logiciel peut être obtenue dans le menu «Help» (aide), sélectionner «About». Les renseignements sur le micrologiciel sont disponibles à partir de l écran principal, appuyer sur le bouton «Connect», puis sélectionner «Entry Setup». Dans l arborescence, sélectionner «TOTALFLOW» (ou le nom identifiant le poste) situé au niveau supérieur de l arborescence. Sélectionner l onglet «Registry». Page 5 of/de 12

- Designed for Pipeline-Quality Natural Gas. 800 to 1500 Btu per standard cubic foot (29.8 to 55.9 megajoules/meter 3 ) - Calculations Per: GPA 2172-96 and 2145-03 (or current). - Carrier Gas: Helium (consumption rate < 20 ml/minute during analysis cycle) - Analysis Time: Approximately five (5) minutes; interval between cycles is user adjustable up to 500 minutes. APPROVAL No. - N D APPROBATION - Conçu pour le gaz naturel de qualité pipeline, de 800 à 1500 BTU par pied cube standard (29,8 à 55,9 MJ/m 3 ). - Calculs selon les normes GPA 2172-96 et 2145-03 (ou version courante). - Gaz vecteur : hélium (débit < 20 ml/min pendant le cycle d analyse). - Durée de l analyse : environ 5 min; l utilisateur peut régler la durée de l intervalle entre les cycles jusqu à un maximum de 500 min. - Four (4) sample streams, one of which can be used as a calibration/validation stream. This applies to the main and secondary units. - Temperature Range (Operation): -18 C to 55 C. For operating temperatures below -18 C, the gas chromatograph must be housed inside an optional temperature controlled environmental enclosure. - Unités principale et secondaire dotées de quatre (4) circuits d échantillonnage, dont un peut servir de circuit d étalonnage/validation. - Plage de températures (fonctionnement) : -18 C à 55 C. Pour les températures de service inférieures à -18 C, le chromatographe en phase gazeuse doit être logé dans une enceinte à température contrôlée facultative. Page 6 of/de 12

- Temperature Range (Storage): -30 C to +60 C - Supply Voltage = 21 to 28 volts DC - Hazardous Area Certifications: - NEC & CEC Class 1, Div. 1, Groups C and D T6 - Communications Ports Supported: -2 serial ports (explosion proof) software configurable for RS232, RS485, RS422 -Optional USB Host and client (explosion proof) -Optional ethernet (explosion proof) Communication ports and I/O are not available for use on the secondary unit. - Protocols Supported: -Totalflow Remote / Local MMI -Totalflow / TCP -Modbus / TCP Server -Modbus / TCP Client -Modbus ASCII or RTU (Modicom, Wordswap, or Danalyzer) -DSFG - Dimensions: 6.75" dia. x 16" long x 9.00" tall (17.1 cm x 40.6 cm x 22.9 cm). This applies to the main and secondary unit - Weatherproof Construction: NEMA/Type-4/IP 56, aluminum alloy with white polyester powder coating. N/A MODELLING APPROVAL No. - N D APPROBATION - Plage de températures (entreposage) : -30 C à +60 C - Tension d alimentation : 21 à 28 V c.c. - Certificats de classification d endroits dangereux : - CNE et CCE classe 1, div. 1, groupes C et D T6 - Ports de communication acceptés : - deux ports série (antidéflagrants) RS232, RS485 et RS422 configurables par logiciel; - port USB hôte et client (antidéflagrant) facultatif; - port Ethernet (antidéflagrant) facultatif. Les ports de communication et d entrée-sortie sont inutilisables pour l unité secondaire. - Protocoles acceptés : -Totalflow à distance / IHM local; -Totalflow / TCP; -Modbus / serveur TCP; -Modbus / client TCP; -Modbus ASCII ou RTU (Modicom, Wordswap ou Danalyzer); - DSFG. - Dimensions : 6,75 po de diamètre x 16 po de longueur x 9,00 po de hauteur (17,1 cm x 40,6 cm x 22,9 cm). Il s agit des dimensions des unités principale et secondaire. - Construction à l épreuve des intempéries : NEMA/type-4/IP 56, alliage d aluminium revêtu de poudre de polyester blanche. S.O. MODÉLISATION Page 7 of/de 12

MARKING REQUIREMENTS Markings shall be in accordance with section 3.5 and 20-3.1 of LMB-EG-08 and section 3-5.5 of Specification S-G-03. Tags #1 and #2 must both be present on device. See page 9 and 10. USER RESTRICTIONS The display on the device cannot be used for transaction purposes. SEALING Gas Chromatographs are exempt from sealing. EVALUATED BY Claude Dupont, CET Senior Legal Metrologist Tel: (613) 952-0630 Fax: (613) 952-1754 E-mail: claude.dupont@ic.gc.ca APPROVAL No. - N D APPROBATION MARQUAGE Le marquage doit être conforme aux exigences des articles 3.5 et 20-3.1 de la norme LMB-EG-08 et de l article 3-5.5 de la norme S-G-03. Les étiquettes n o 1 et n o 2 doivent toutes deux être présentes sur l appareil. Voir pages 9 et 10. RESTRICTIONS POUR L UTILISATEUR L affichage du dispositif ne peut pas être utilisé à des fins de transaction. SCELLAGE Aucune exigence de scellage n est prescrite pour les chromatographes en phase gazeuse. ÉVALUÉ PAR Claude Dupont, CET Métrologiste légal principal Tél. : 613-952-0630 Téléc. : 613-952-1754 Courriel : claude.dupont@ic.gc.ca Page 8 of/de 12

Figure 1 NGC Feed-Through Assembly / Ensemble de traversée du NGC Figure 2 Analytical Module / Module analytique Figure 3 Module Assembly / Module de CPG Chrom Module = Module de chromatographie Oven wall cylinder = Paroi cylindrique du four Figure 4 Manifold Assembly / Collecteur Figure 5 Analytical Processor Assembly /Processeur analytique Analog processor board = Carte processeur analogique Shield plate = Plaque de protection Support shield = Plaque support Page 9 of/de 12

Figure 6 Environment Enclosure Installation with Electric Heater / Montage dans l abri contre les intempéries avec appareil de chauffage électrique Auxiliary Unit = Unité secondaire Main Unit = Unité principale Sample Conditioning Module = Système de conditionnement de l échantillon Sample Probe = Sonde d échantillonnage Carrier Gas = Gaz vecteur Calibration Gas = Gaz d étalonnage Figure 7 Tag #1 - Measurement Canada Name Plate / Étiquette n o 1 Plaque signalétique de Mesures Canada Page 10 of/de 12

Figure 8 Tag # 2 - Device Name Plate / Étiquette n o 2 Plaque signalétique de l appareil Figure 9 8209 APPROVAL: Page 11 of/de 12

The design, composition, construction and performance of the meter type(s) identified herein have been evaluated in accordance with regulations and specifications established under the Electricity and Gas Inspection Act. Approval is hereby granted accordingly pursuant to subsection 9(4) of the said Act. The sealing, marking, installation, use and manner of use of meters are subject to inspection in accordance with regulations and specifications established under the Electricity and Gas Inspection Act. The sealing and marking requirements are set forth in specifications established pursuant to section 18 of the Electricity and Gas Inspection Regulations. Installation and use requirements are set forth in specifications established pursuant to section 12 of the Regulations. Verification of conformity is required in addition to this approval for all metering devices excepting instrument transformers. Inquiries regarding inspection and verification should be addressed to the local inspection office of Industry Canada. APPROBATION : La conception, la composition, la construction et le rendement du(des) type(s) de compteurs identifié(s) ci-dessus, ayant fait l objet d une évaluation conformément au Règlement et aux normes établis aux termes de la Loi sur l inspection de l électricité et du gaz, la présente approbation est accordée en application du paragraphe 9(4) de la dite Loi. Le scellage, l installation, le marquage, et l utilisation des compteurs sont soumis à l inspection conformément au Règlement et aux normes établis aux termes de la Loi sur l inspection de l électricité et du gaz. Les exigences de scellage et de marquage sont définies dans les normes établies en vertu de l article 18 du Règlement sur l inspection de l électricité et du gaz. Les exigences d installation et d utilisation sont définies dans les normes établies en vertu de l article 12 du dit règlement. Sauf dans les cas des transformateurs de mesure, une vérification de conformité est requise. Toute question sur l inspection et la vérification de conformité doit être adressée au bureau local d Industrie Canada. Original copy signed by: Copie authentique signée par : Patrick J. Hardock, P.Eng. Senior Engineer Gas Measurement Engineering and Laboratory Services Directorate Patrick J. Hardock, P.Eng. Ingénieur principal Mesure des gaz Direction de l ingénierie et des services de laboratoire Date: 2011-09-15 Web Site Address / Adresse du site Internet : http://mc.ic.gc.ca Page 12 of/de 12