Omni Flow Computers, Inc. 12620 W. Airport Blvd., Suite 100 Sugar Land, TX, 77478 USA



Documents pareils
Maximum Capacity / Capacité maximal: 10 kg/min

Fisher Controls International Inc South 17th Avenue Marshalltown, IA, USA

Metretek Incorporated 305 East Drive, Suite A Melbourne, Florida, USA

Schneider Electric 19 Waterman Ave. Toronto, Ontario M4B 1Y2. Square D/Schneider Electric 295 Tech Park Drive LaVergne, TN USA

Kraft Fuels/Alternate Fuels Technology Inc. 50 Ritin Lane, Unit 20 Concord, Ontario L4K 4C9

Daniel Industries Canada Inc nd Avenue S.E. P.O. Box 727, Station T Calgary, AB T2H 2H2

Daniel Industries Canada Inc. A Division of Emerson Process Management nd Avenue SE Calgary, Alberta T2C 2G5

Itron Canada Inc. 6507C Mississauga Road Mississauga, Ontario L5N 1A6. Itron B North Highway 11 West Union, South Carolina, USA

Paxton. ins Net2 desktop reader USB

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

Mercury Instruments Inc Virginia Avenue Cincinnati, Ohio, USA Mercury Instruments Inc Virginia Avenue Cincinnati, Ohio, USA 45227

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

Règlement relatif à l examen fait conformément à la Déclaration canadienne des droits. Canadian Bill of Rights Examination Regulations CODIFICATION

Mercury Instruments Inc Virginia Avenue Cincinnati, Ohio, USA Mercury Instruments Inc Virginia Avenue Cincinnati, Ohio, USA 45227

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

Ships Elevator Regulations. Règlement sur les ascenseurs de navires CODIFICATION CONSOLIDATION. C.R.C., c C.R.C., ch. 1482

Credit Note and Debit Note Information (GST/ HST) Regulations

THE LAW SOCIETY OF UPPER CANADA BY-LAW 19 [HANDLING OF MONEY AND OTHER PROPERTY] MOTION TO BE MOVED AT THE MEETING OF CONVOCATION ON JANUARY 24, 2002

Disclosure on Account Opening by Telephone Request (Trust and Loan Companies) Regulations

General Import Permit No. 13 Beef and Veal for Personal Use. Licence générale d importation n O 13 bœuf et veau pour usage personnel CONSOLIDATION

Material Banking Group Percentage Regulations. Règlement fixant le pourcentage (groupe bancaire important) CONSOLIDATION CODIFICATION

Calculation of Interest Regulations. Règlement sur le calcul des intérêts CONSOLIDATION CODIFICATION. Current to August 4, 2015 À jour au 4 août 2015

Short-term Pooled Investment Fund Regulations. Règlement sur le fonds commun de placement à court terme CONSOLIDATION CODIFICATION

Notice Technique / Technical Manual

Disclosure on Account Opening by Telephone Request (Retail Associations) Regulations

MODULES ÉLECTRIQUES. - systèmes électriques DC - onduleurs - convertisseurs - interrupteurs statiques. Notre alimentation Votre confiance

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

Import Allocation Regulations. Règlement sur les autorisations d importation CONSOLIDATION CODIFICATION

Export Permit (Steel Monitoring) Regulations. Règlement sur les licences d exportation (surveillance de l acier) CONSOLIDATION CODIFICATION

Interest Rate for Customs Purposes Regulations. Règlement sur le taux d intérêt aux fins des douanes CONSOLIDATION CODIFICATION

Critères à l attention des fabricants et des fournisseurs de biens ou de services : dispositifs mécaniques pour bingo

Nordion Europe S.A. Incorporation Authorization Order. Décret autorisant la constitution de Nordion Europe S.A. CONSOLIDATION CODIFICATION

Règlement sur les baux visés à la Loi no 1 de 1977 portant affectation de crédits. Appropriation Act No. 1, 1977, Leasing Regulations CODIFICATION

Order Binding Certain Agents of Her Majesty for the Purposes of Part 1 of the Personal Information Protection and Electronic Documents Act

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

CONSOLIDATION CODIFICATION. Current to August 30, 2015 À jour au 30 août 2015

Railway Operating Certificate Regulations. Règlement sur les certificats d exploitation de chemin de fer CODIFICATION CONSOLIDATION

Indicateur universel de procédé format 96 x 48 mm ( 1 /8 DIN)

Fabricant. 2 terminals

Form of Deeds Relating to Certain Successions of Cree and Naskapi Beneficiaries Regulations

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

Appointment or Deployment of Alternates Regulations. Règlement sur la nomination ou la mutation de remplaçants CONSOLIDATION CODIFICATION

Guide d'installation rapide TFM-560X YO.13

Loi sur l aide financière à la Banque Commerciale du Canada. Canadian Commercial Bank Financial Assistance Act CODIFICATION CONSOLIDATION

Name Use (Affiliates of Banks or Bank Holding Companies) Regulations

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

Life Companies Borrowing Regulations. Règlement sur les emprunts des sociétés d assurance-vie CONSOLIDATION CODIFICATION

Fiche technique CPU 314SC/DPM (314-6CG13)

de stabilisation financière

TERRITOIRES DU NORD-OUEST RÈGLEMENT SUR LA FORMULE DE NOTIFICATION R FORM OF NOTIFICATION REGULATIONS R

Fonctions intégrées. Nouvelles solutions universelles & système de communication

Archived Content. Contenu archivé

Avis certifiant que des pays accordent les avantages du droit d auteur. Certification of Countries Granting Equal Copyright Protection Notice

CODIFICATION CONSOLIDATION. Current to August 30, À jour au 30 août Last amended on December 12, 2013

Resident Canadian (Insurance Companies) Regulations. Règlement sur les résidents canadiens (sociétés d assurances) CONSOLIDATION CODIFICATION

Input Tax Credit Information (GST/HST) Regulations

Order Assigning to the Minister of the Environment, the Administration, Management and Control of Certain Public Lands

Borrowing (Property and Casualty Companies and Marine Companies) Regulations

Ordonnance sur le paiement à un enfant ou à une personne qui n est pas saine d esprit. Infant or Person of Unsound Mind Payment Order CODIFICATION

Contrôle d'accès Access control. Notice technique / Technical Manual

If the corporation is or intends to become a registered charity as defined in the Income Tax Act, a copy of these documents must be sent to:

Garage Door Monitor Model 829LM

T500 DUAlTACH. JAQUET T500 DualTach Instrument de mesure et de surveillance équipé de 2 entrées fréquence TACHYMETRE 2 CANAUX

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

CONTEC CO., LTD. Novembre 2010

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

Folio Case User s Guide

TM238LDA24DR 230VAC - RELAYS OUTPUTS -

AUDIT COMMITTEE: TERMS OF REFERENCE

Laboratory accredited by the French Home Office (official gazette date February 5 th, 1959, modified) Valid five years from August 27 th, 2013

Loi sur la Semaine nationale du don de sang. National Blood Donor Week Act CODIFICATION CONSOLIDATION. S.C. 2008, c. 4 L.C. 2008, ch.

I. Programmation I. 1 Ecrire un programme en Scilab traduisant l organigramme montré ci-après (on pourra utiliser les annexes):

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

VTP. LAN Switching and Wireless Chapitre 4

OFFICIAL STATUS OF CONSOLIDATIONS CARACTÈRE OFFICIEL DES CODIFICATIONS

DECLARATION OF PERFORMANCE. No DoP_FAC_003

Master4Light. Caractérisation Optique et Electrique des Sources Lumineuses. Equipement 2-en-1 : source de courant et spectrophotomètre

Air Transportation Tax Order, Décret de 1995 sur la taxe de transport aérien CONSOLIDATION CODIFICATION

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

MANUEL D INSTRUCTION

Accu-Sort Systems Inc. 511 School House Road Telford, Pennsylvania, USA

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN 61303:1997

BILL 203 PROJET DE LOI 203

Le No.1 de l économie d énergie pour patinoires.

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Instructions Mozilla Thunderbird Page 1

F1 Security Requirement Check List (SRCL)

epowerswitch 8XM+ Fiche technique

LE FORMAT DES RAPPORTS DU PERSONNEL DES COMMISSIONS DE DISTRICT D AMENAGEMENT FORMAT OF DISTRICT PLANNING COMMISSION STAFF REPORTS

0 20mV; 0 40mV; 0 80mV; 0 160mV; 0 320mV; 0 640mV; 0 1,28V; 0 2,56V 0 5V; 0 10V

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

APPENDIX 6 BONUS RING FORMAT

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Loi sur la remise de certaines dettes liées à l aide publique au développement. Forgiveness of Certain Official Development Assistance Debts Act

Transcription:

Measurement Canada An agency of Industry Canada Un organisme d Industrie Canada APPROVAL No. - N D APPROBATION Mesures Canada NOTICE OF CONDITIONAL APPROVAL Issued by statutory authority of the Minister of Industry for: AVIS D APPROBATION CONDITIONNELLE Émis en vertu du pouvoir statutaire du ministre de l Industrie pour: TYPE OF DEVICE Electronic Flow Computer APPLICANT TYPE D APPAREIL Débitmètre électronique REQUÉRANT Omni Flow Computers, Inc. 12620 W. Airport Blvd., Suite 100 Sugar Land, TX, 77478 USA MANUFACTURER FABRICANT Omni Flow Computers, Inc. 12620 W. Airport Blvd., Suite 100 Sugar Land, TX, 77478 USA MODEL(S)/MODÈLE(S) 3000 6000 RATING/ CLASSEMENT See Summary Description / Voir «Description Sommaire» Page 1 of/de 17

NOTE: This approval applies only to meters, the design, composition, construction and performance of which are, in every material respect, identical to that described in the material submitted, and that are typified by samples submitted by the applicant for evaluation for approval in accordance with sections 13 and 14 of the Electricity and Gas Inspection Regulations. The following is a summary of the principal features only. REMARQUE : Cette approbation ne vise que les compteurs dont la conception, la composition, la construction et le rendement sont identiques, en tout point, à ceux qui sont décrits dans la documentation reçue et pour lesquels des échantillons représentatifs ont été fournis par le requérant aux fins d évaluation, conformément aux articles 13 et 14 du Règlement sur l inspection de l électricité et du gaz. Ce qui suit est une brève description de leurs principales caractéristiques. SUMMARY DESCRIPTION: DESCRIPTION SOMMAIRE : The Omni model 3000 and model 6000 are microprocessor based flow computers that perform gas flow calculations. The model 3000 is a single flow run design while the model 6000 can be configured for up to four meter runs. NOTE: Omni model 3000 and model 6000 flow computers are also approved under AG-0466 but without the linearization function. Main Components Each flow computer consist of an enclosure that has a keyboard, an LCD, three electro-mechanical counters and four status LED s located on the front panel. The enclosure contains a backplane that is connected through ribbon cables to terminal blocks on the back of the enclosure. Power supply, CPU and I/O modules are plugged into this backplane. Keypad A thirty-four key domed membrane keypad provides the capability to configure flow runs, perform diagnostic tasks, and retrieve data. Les modèles 3000 et 6000 d Omni sont des débitmètres commandés par microprocesseur qui effectuent des calculs de débit du gaz. Le modèle 3000 est un appareil à une seule voie de mesure, alors que le modèle 6000 peut être configuré pour jusqu à quatre voies de mesure. NOTE: Les modèle de débimètres 3000 et 6000 d Omni sont aussi approuvés sous AG-0466 mais sans la fonction de linéarisation. Éléments principaux Chaque débitmètre est constitué d une enceinte qui comporte un clavier, un afficheur à cristaux liquides, 3 totalisateurs électromécaniques et 4 DEL d état situés sur le panneau avant. L enceinte comporte un fond de panier qui est connecté à des borniers sur l arrière de l enceinte au moyen de câbles-rubans. Les modules d alimentation, CPU et d E/S sont branchés sur ce fond de panier. Clavier Un clavier à membrane bombée de 34 touches offre la capacité de configurer les débits, d effectuer des tâches de diagnostic et d extraire des données. Page 2 of/de 17

Liquid Crystal Display (LCD) Display: 4 lines of 20 characters 5 x 8 dot matrix Display Data: Alphanumeric, 80 characters Backlight: Green/Yellow LED Electro-Mechanical Counters The three 6-digit electro-mechanical non-resettable totalizers may be configured to indicate either uncorrected volume, corrected volume, energy or mass totals. Additional totalizers are included in the firmware. CPU Modules P/N 68-6001 CPU type Clock Speed Coprocessor Clock Speed EPROM RAM Motorola MC68HC000FN16 16 MHz MotorolaMC68HC881/82FN16B 16 MHz 1 MB, expandable to 2 MB max. 512 KB expandable to 1 MB max. Real Time Clock Battery backed-up, time of day; Programmable interval down to 10 msec RAM Battery Typical RAM backup period 3.6 Vdc Ni-Cad 30-60 days (with power removed) Afficheur à cristaux liquides (ACL) Affichage: 4 lignes de 20 caractères, matrice à points 5 x 8 Données d affichage: Alphanumérique, 80 caractères Rétroéclairage: DEL vert/jaune Totaliseurs électromécaniques Les 3 totalisateurs électromécaniques sans remise à zéro peuvent être configurés pour indiquer soit le total du volume non corrigé, du volume corrigé, de l énergie ou de la masse. Des totalisateurs supplémentaires sont inclus dans les microprogrammes. Modules CPU N o de pièce 68-6001 Type de CPU Motorola MC68HC000FN16 Vitesse d horloge 16 MHz Coprocesseur Motorola MC68HC881/82FN16B Vitesse d horloge 16 MHz EPROM 1 Mo, extensible à 2 Mo max. RAM 512 Ko, extensible à 1 Mo max. Horloge en temps Heure du jour protégée par pile; réel intervalle programmable jusqu à 10 ms Pile de RAM Période type de sauvegarde de la mémoire vive 3,6 V c.c. Ni-Cad 30-60 jours (hors tension) P/N 68-6201 CPU type Clock Speed Flash Memory RAM Real Time Clock RAM Battery Typical RAM backup period 32-bit Freescale MCF5232 100 MHz 4 MB 4 MB Fast 2 MB Battery Backed Battery backed-up, time of day 3.6 Vdc NiMH 90 days (with power removed) N o de pièce 68-6201 Type de CPU Vitesse d horloge Mémoire flash RAM Real Time Clock Pile de RAM Période type de sauvegarde de la mémoire 32 bits Freescale MCF5232 100 MHz 4 Mo 4 Mo rapide 2 Mo protégée par pile Heure du jour protégée par pile 3,6 V c.c. accumulateur NiMH 90 jours (hors tension) Page 3 of/de 17

Power Supply Modules The power supply modules with the following part numbers can be used: 68-6118 68-6218 Process I/O Combination Modules All flow parameter measurements are input via plug-in process I/O combination modules which are summarized below. A Type (p/n 68-6006 or 68-6206) 2 analog or RTD inputs (jumper selectable) 2 analog or pulse inputs (jumper selectable) 2 analog outputs B Type (p/n 68-6006 or 68-6206) 2 analog or RTD inputs (jumper selectable) 1 analog or pulse input (jumper selectable) 1 frequency density input 1 analog output E Type (p/n 68-6008 or 68-6208) 2 analog or RTD inputs (jumper selectable) 2 pulse inputs, with pulse fidelity or double chronometry proving capabilities (jumper selectable) 2 analog outputs E/D Type (p/n 68-6008 or 68-6208) 2 analog or RTD inputs (jumper selectable) 2 frequency density inputs 2 analog outputs Modules d alimentation On peut utiliser les modules d alimentation portant les numéros de pièce suivants : 68-6118 68-6218 Modules de combinaison d E/S de service Toutes les mesures des paramètres de débit sont entrées par l entremise de modules enfichables de combinaison d E/S de service dont un résumé se trouve ci-dessous. Type A (n o de pièce 68-6006 ou 68-6206) 2 entrées analogiques ou RTD (sélectionnable par cavalier) 2 entrées analogiques ou à impulsions (sélectionnable par cavalier) 2 sorties analogiques Type B (n o de pièce 68-6006 ou 68-6206) 2 entrées analogiques ou RTD (sélectionnable par cavalier) 1 entrée analogique ou à impulsions (sélectionnable par cavalier) 1 entrée de densité de fréquence 1 sortie analogique Type E (n o de pièce 68-6008 ou 68-6208) 2 entrées analogiques ou RTD (sélectionnable par cavalier) 2 entrées à impulsions, avec capacités d étalonnage de fidélité des impulsions ou de chronométrie double (sélectionnable par cavalier) 2 sorties analogiques Type E/D (n o de pièce 68-6008 ou 68-6208) 2 entrées analogiques ou RTD (sélectionnable par cavalier) 2 entrées de densité de fréquence 2 sorties analogiques Page 4 of/de 17

H Type or HV Type (p/n 68-6004) 4 single variable (H type) or multi-variable (HV type) Honeywell Smart transmitter inputs 2 analog outputs SV (p/n 68-6203) 2 RS-485 ports 6 analog outputs HT (p/n 68-6207-HT) 4 point to point HART networks (up to 4 HART devices per module) HM (p/n 68-6207-HM) 4 multi-drop or multi-variable HART networks (up to 16 HART devices per module) Communications Modules S (p/n 68-6005) 2 proprietary RS-232 ports (multi-drop when using the RS-485 mode and a external RS-232 to RS-485 converter) S (p/n 68-6205) 2 RS-232 or RS-485 ports (selectable) SE (p/n 68-6209) a RS-232 or RS-485 port (selectable) a 10BaseT ethernet port a 2-wire RS-485 repeater port a RS-232 configuration port Type H ou type HV (n o de pièce 68-6004) 4 entrées de transmetteur intelligent Honeywell à variable simple (type H) ou à variables multiples (type HV) 2 sorties analogiques Type SV (n o de pièce 68-6203) 2 ports RS-485 6 sorties analogiques Type HT (n o de pièce 68-6207-HT) 4 réseaux HART point à point (jusqu à 4 dispositifs HART par module) Type HM (n o de pièce 68-6207-HM) 4 réseaux HART à branchements et variables multiples (jusqu à 16 dispositifs HART par module) Modules de communication Module S (n o de pièce 68-6005) 2 ports RS-232 brevetés (à branchements multiples en mode RS-485 et avec utilisation d un convertisseur RS-232/RS-485 externe) Module S (n o de pièce 68-6205) 2 ports RS-232 ou RS-485 (sélectionnables) Module SE (n o de pièce 68-6205) 2 ports RS-232 ou RS-485 (sélectionnables) 1 port Ethernet 10BaseT 1 port de répéteur RS-485 à deux fils 1 port de configuration RS-232 Approved Functions Flow Calculations AGA-3 (1992) AGA-7 Fonctions approuvées Calculs de débit AGA-3 (1992) AGA-7 Supercompressibility Calculations AGA-8 (1994) Detail Calculs de surcompressibilité AGA-8 (1994) Méthode détaillée Page 5 of/de 17

Energy Calculations The flow computers calculate the heating value and energy flow rate from the entered gas components in accordance with AGA-5. Analog Inputs The analog inputs mapped to process inputs for temperature and pressure are approved for custody transfer. RTD Temperature Measurement The flowing gas temperature can be measured using an external 4-wire PRTD, that has an alpha coefficient of 0.00385 or 0.00392 ohm/ohm/ C, measures 100 ohms at 0 C and meets either a class A or B type designation of the IEC 751 specification. Pulse Inputs The pulse inputs are jumper selectable to accept either a square wave or a zero crossing AC voltage signal from an approved and compatible flow meter. Honeywell Smart Transmitter Inputs Digitally enhanced (DE) inputs from approved Honeywell smart transmitters may be used for pressure, differential pressure and temperature. Modbus Communications Protocol Digital communication using the Modbus protocol over RS-232 or RS-485 serial connections to obtain process parameters, from an approved and compatible transmitter, ultrasonic meter and/or gas chromatograph, is approved for custody transfer. Calculs d énergie Les débitmètres électroniques calculent le pouvoir calorifique et le débit d énergie à partir des composantes du gaz entrées conformément à l AGA-5. Entrées analogiques Les entrées analogiques mises en correspondance avec les entrées de température et de pression de service sont approuvées aux fins de transfert fiduciaire. Mesure de la température du gaz en écoulement La température du gaz en écoulement peut être mesurée au moyen d un capteur à résistance thermométrique en platine externe, à quatre fils, ayant un coefficient alpha de 0,00385 ou 0,00392 ohm/ohm/ C et une résistance de 100 ohms à 0 C et satisfaisant aux exigences de classe A ou B de la norme CEI 751. Entrées à impulsions Les entrées à impulsions sont sélectionnables par cavalier pour accepter soit une onde carrée, soit un signal de passage à zéro de la tension c.a. venant d un débitmètre compatible. Entrées de transmetteur intelligent Honeywell Les entrées améliorées numériquement des transmetteurs intelligents Honeywell approuvés peuvent être utilisées pour la pression, la pression différentielle et la température. Protocole de communications Modbus La transmission numérique par protocole de communication Modbus sur des connexions série RS-232 ou RS-485 afin d obtenir les paramètres de service à partir d un transmetteur, d un compteur à ultrasons et/ou d un chromatographe en phase gazeuse approuvés et compatibles est approuvée aux fins de transfert fiduciaire. Page 6 of/de 17

Live Chromatography Omni 3000 and 6000 flow computers accept live chromatographic inputs from approved chromatographs manufactured by Daniel Industries or Applied Automation through one of the serial ports. Linear Interpolation Linearization Function The linearization function using linear interpolation of the k-factor versus flow rate is approved for use in custody transfer. The flow computers can be configured with up to twelve points. Functions NOT Approved Flow Calculations Flow calculation methods that are not listed in the Approved Functions section shall not be used for custody transfer. Supercompressibility Calculations Methods for calculating Supercompressibility that are not listed in the Approved Functions section shall not be used for custody transfer. Analog Outputs The analog outputs are not approved for custody transfer but may be used for process control. Digital I/O The digital I/O is not approved for custody transfer but may be used for process control. Event Logger The event logger is not approved for custody transfer and access to the configuration shall be sealed. Chromatographie directe Les débitmètres Omni 3000 et 6000 acceptent, par l entremise d un des ports série, des entrées chromatographiques directes provenant de chromatographes approuvés fabriqués par Daniel Industries ou Applied Automation. Fonction de linéarisation par interpolation linéaire La fonction de linéarisation par interpolation linéaire du facteur K par rapport au débit est approuvée pour le transfert fiduciaire. Les débitmètres peut être configuré pour un maximum de douze points d essais. Fonctions non approuvées Calculs de débit Les méthodes de calcul de débit qui ne figurent pas sous la rubrique «Fonctions approuvées» ne doivent pas être utilisées aux fins de transfert fiduciaire. Calculs de surcompressibilité Les méthodes de calcul de surcompressibilité qui ne figurent pas sous la rubrique «Fonctions approuvées» ne doivent pas être utilisées aux fins de transfert fiduciaire. Sorties analogiques Les sorties analogiques ne sont pas approuvées aux fins de transfert fiduciaire, mais peuvent être utilisées aux fins de commande de processus. E/S numérique L E/S numérique n est pas approuvée aux fins de transfert fiduciaire, mais peut être utilisée aux fins de commande de processus. Enregistreur d événements L enregistreur d événements n est pas approuvé aux fins de transfert fiduciaire, et l accès à la configuration doit être scellé. Page 7 of/de 17

Materials of Construction Omni 3000 and 6000 flow computers are mounted in NEMA 4 or NEMA 4X weather proof enclosures or a NEMA 7 explosion proof enclosure. Firmware The following firmware versions are approved: 23.71 23.74 23.75 27.71 27.74 27.75 Firmware is stored in positions U3 and U4 on the CPU module. Software A PC type computer running Omnicom software can be used to communicate with an OMNI 3000 or 6000 flow computer. Use of this software permits configuration, interrogation, calibration and data retrieval prior to sealing. Specifications Matériaux de construction Les débitmètres Omni 3000 et 6000 sont logés à l intérieur de boîtiers NEMA 4 ou NEMA 4X à l épreuve des intempéries ou de boîtiers NEMA 7 antidéflagrants. Microprogramme Les versions de microprogramme suivantes sont approuvées : 23.71 27.71 23.74 27.74 23.75 27.75 Le microprogramme est stocké dans les positions U3 et U4 du module CPU. Logiciel Un ordinateur personnel faisant tourner le logiciel «Omnicon» peut être utilisé pour communiquer avec un débitmètre OMNI 3000 ou 6000. L utilisation de ce logiciel permet la configuration, l interrogation, l étalonnage et l extraction de données avant le scellement. Caractéristiques Operating temperature Verified operating temperature Relative humidity 68-6118 Power Module AC supply voltage Optional AC supply voltage AC supply frequency DC supply voltage AC and DC supply power (excluding transducer loops) (0 to 40) C (0 to 40) C 80% noncondensing maximum 120 Vac 220 to 250 Vac 50 to 500 Hz 18 to 30 Vdc 10 to 20 Watts Température de fonctionnement (0 à 40) C Température de fonctionnement (0 à 40) C vérifiée Humidité relative maximum 80% sans condensation Module d alimentation 68-6118 Tension d alimentation c.a. 120 V c.a. Tension d alimentation c.a. 220 à 250 V c.a. optionnelle Fréquence d alimentation c.a. 50 à 500 Hz Tension d alimentation c.c. 18 à 30 V c.c. Puissance d alimentation c.a. 10 à 20 watts et c.c. (excluant les boucles de transducteurs) Page 8 of/de 17

68-6218 Power Module AC supply voltage AC supply frequency DC supply voltage AC and DC supply power (excluding transducer loops) 100 to 250 Vac 50 to 500 Hz 22 to 28 Vdc 10 to 30 Watts Module d alimentation 68-6218 Tension d alimentation c.a. 100 à 250 V c.a. Fréquence d alimentation c.a. 50 à 500 Hz Tension d alimentation c.c. 22 à 28 V c.c. Puissance d alimentation c.a. 10 à 30 watts et c.c. (excluant les boucles de transducteurs) Transducer Output Power: 24 Vdc at 750 ma+ for most configurations (when AC powered) Puissance de sortie des transducteurs 24 V c.c. à 750 ma+ pour la plupart des configurations (si alimenté en c.a.) Square Wave Pulse Inputs Maximum frequency Positive going threshold Negative going threshold Maximum input voltage Sine Wave Pulse Inputs Maximum frequency Positive going threshold Negative going threshold Maximum input voltage 15 khz 4.2 Vdc (nominal) 3.2 Vdc (nominal) 30 Vdc 12 khz 4.2 Vdc (nominal) 3.2 Vdc (nominal) 30 Vdc Impulsions d entrée à onde carrée Fréquence maximale 15 khz Seuil de sens positif 4,2 V c.c. (nominal) Seuil de sens négatif 3,2 V c.c. (nominal) Tension d entrée maximale 30 V c.c. Impulsions d entrée à onde sinusoïdale Fréquence maximale 12 khz Seuil de sens positif 4,2 V c.c. (nominal) Seuil de sens négatif 3,2 V c.c. (nominal) Tension d entrée maximale 30 V c.c. Electromechanical Counters Maximum Count Rate 10 counts per second Compteurs électromécaniques Taux de comptage maximal 10 coups/seconde Analog Inputs Type (jumper selectable) Resolution 4-20 ma or 1-5 V 14 bits Entrées analogiques Type (sélectionnable par cavalier) Résolution 4-20 ma ou 1-5 V 14 bits MARKINGS The following information is marked on the nameplate or nameplates secured to the flow computer in accordance with the following sections of LMB-EG-08: 3-5.1 3-5.2 contractors inspection number badge MARQUAGE Les renseignements suivants sont indiqués sur la ou les plaques(s) signalétique(s) apposée(s) sur le débitmètre-ordinateur selon les articles suivants de LMB-EG-08 : 3-5.1 3-5.2 numéro d insigne d inspection du fournisseur Page 9 of/de 17

The following information is marked on either the nameplate or displayable using the PC based configuration software listed under the heading Software : 3-5.5 (as per section 5.3.4 of S-G-03) 15-4.1 (c) 21-2.4 SEALING The Omni 3000/6000 is sealed by putting the Program Inhibit switch, located behind the keypad, in the lock position(down) to prevent configuration changes from the keypad. A sealing wire is then passed through holes provided in the outer housing to prevent removal of the chassis. CPU modules using Flash memory shall have the Flash Update jumper in the disabled position. For units mounted in NEMA 4 and NEMA 4X enclosures,additional sealing is accomplished by passing a sealing wire through the door latch. The NEMA 7 enclosure is sealed by passing a sealing wire through holes in two of the bolts retaining the front cover. Serial port access is permitted for a dedicated printer (output), gas chromatograph(live input) and external computer systems(output only from Omni 3000/6000). A two-way serial port intended for use with Omnicom software, must be put in lockout mode using the Program Inhibit switch prior to sealing. INSTALLATION REQUIREMENTS The flow computers have a common input for atmospheric pressure and shall be limited to use with groups of primary meters and orifice runs such that the requirements of the Electricity and Gas Inspection Regulations will be complied with. Les renseignements suivants peuvent être inscrits sur la plaque signalétique ou peuvent être visualisés au moyen du logiciel informatique indiqué sous la rubrique «Logiciel» : 3-5.5 (selon la section 5.3.4 de la norme S-G-03) 15-4.1 (c) 21-2.4 SCELLEMENT Le scellement de l Omni 2000/6000 s effectue en plaçant l interrupteur «Program Inhibit», situé derrière le bloc de touches, dans la position de verrouillage pour empêcher la modification de la configuration à partir du bloc de touches. Un fil métallique est ensuite passé dans les trous prévus dans le boîtier extérieur pour empêcher le retrait du châssis. Dans le cas des modules CPU faisant appel à une mémoire flash, le cavalier «Flash Update» connexe doit être dans la position d invalidation. Pour les unités montées à l intérieur de boîtiers NEMA 4 et NEMA 4X, le scellement additionnel s effectue en passant un fil métallique par le verrou de la porte. Le boîtier NEMA 7 est scellé en passant un fil métallique à travers les trous de deux des boulons retenant le panneau avant. L accès au port série est possible pour une imprimante spéciale (sortie), un chromatographe en phase gazeuse (entrée directe) et un ordinateur externe (sortie seulement de l Omni 3000/6000). Un port série à deux canaux destiné à être utilisé avec le logiciel Omnicon doit être mis en mode de verrouillage à l aide de l interrupteur d interdiction avant le scellement. EXIGENCES EN MATIÈRE D INSTALLATION Les débitmètres possèdent une entrée commune pour la pression atmosphérique qui devrait être utilisée seulement avec les groupes de voies des compteurs primaires et des compteurs à orifice de façon à satisfaire aux prescriptions du Règlement sur l inspection de l électricité et du gaz. Page 10 of/de 17

VERIFICATION Energy Calculations The true calorific power and relative density of the sample gas shall be calculated using the true relative concentrations of all components of the sample gas as established in accordance with the Gas Processors Association standards, Calculation of Gross Heating Value, Relative Density and Compressibility Factor for Natural Gas Mixtures from Compositional Analysis, GPA 2172, and Table of Physical Constants for Hydrocarbons and Other Compounds of Interest to the Natural Industry, GPA 2145. EVALUATED BY Revision 1 Ed DeSousa Senior Legal Metrologist Tel: 613-941-3454 Fax: 613-952-1754 email: edwardo.desousa@ic.gc.ca Original (2010-01-27) Dwight Dubie Complex Approvals Examiner VÉRIFICATION Calculs d énergie Le pouvoir calorifique et la densité relative réels de l'échantillon de gaz doivent être calculés à l'aide des concentrations relatives réelles de toutes les composantes du gaz échantillon établies conformément aux normes de la Gas Processors Association, Calculation of Gross Heating Value, Relative Density and Compressibility Factor for Natural Gas Mixtures from Compositional Analysis, GPA 2172 et Table of Physical Constants for Hydrocarbons and Other Compounds of Interest to the Natural Gas Industry, GPA 2145. ÉVALUÉ PAR Révision 1 Ed DeSousa Métrologiste légal principal Tél. : 613-941-3454 Fax : 613-952-1754 Courriel : edwardo.desousa@ic.gc.ca Original (2010-01-27) Dwight Dubie Examinateur d approbations complexes Page 11 of/de 17

Page 12 of/de 17

Page 13 of/de 17

Page 14 of/de 17

Page 15 of/de 17

APPROVAL: The design, composition, construction and performance of the meter type(s) identified herein have been evaluated in accordance with regulations and specifications established under the Electricity and Gas Inspection Act. Approval is hereby granted accordingly pursuant to subsection 9(4) of the said Act. The sealing, marking, installation, use and manner of use of meters are subject to inspection in accordance with regulations and specifications established under the Electricity and Gas Inspection Act. The sealing and marking requirements are set forth in specifications established pursuant to section 18 of the Electricity and Gas Inspection Regulations. Installation and use requirements are set forth in specifications established pursuant to section12 of the Regulations. Verification of conformity is required in addition to this approval for all metering devices excepting instrument transformers. Inquiries regarding inspection and verification should be addressed to the local office of Measurement Canada. TERMS AND CONDITIONS The Linear Interpolation Linearization Function of this device has been assessed against and found to comply with the requirements of: Provisional Specifications and Procedures for the Approval of Correction Devices and Linearization Functions Incorporated in Meters and Flow Computers, (2006-03-31). This conditional approval will expire upon the revocation of this provisional specification and no further devices will be authorized to be placed in service unless permitted by transitory measures announced at the time of the revocation of the provisional specification. APPROBATION : La conception, la composition, la construction et le rendement du(des) type(s) de compteur(s) identifié(s) cidessus ont été évalués conformément au Règlement et aux normes établis en vertu de la Loi sur l inspection de l électricité et du gaz. La présente approbation est accordée enapplicationduparagraphe 9(4) de ladite Loi. Le scellage, l installation, le marquage, et l utilisation des compteurs sont soumis à l inspection conformément au Règlement et aux normes établis en vertu de la Loi sur l inspection de l électricité et du gaz. Les exigences de scellage et de marquage sont définies dans les normes établies en vertu de l article 18 du Règlement sur l inspection de l électricité et du gaz. Les exigences d installation et d utilisationsont définies dans les normes établies en vertu de l article 12 dudit règlement. En plus de cette approbation et sauf dans les cas des transformateurs de mesure,une vérificationde conformité est requise. Toute question sur l inspection et la vérification de conformité doit être adressée au bureau local de Mesures Canada. MODALITÉS ET CONDITIONS La Fonctionde linéarisation par interpolation linéaire a été évaluée et jugée conforme aux exigences de: Norme et procédures provisoires pour l approbation des appareils de correction et des fonctions de linéarisation intégrées aux compteurs et aux débitmètres-ordinateurs, (2006-03-31). La présente approbation conditionnelle prendra fin lors de la révocation de la norme provisoire et aucun autre appareil ne pourra être mis en service à moins qu il en soit prévu autrement dans des mesures transitoires annoncées au moment de la révocation de la norme provisoire. Page 16 of/de 17

Devices installed, initially inspected, and verified under the authority of this conditional approval may require subsequent modifications by the applicant to comply with any new specifications. Les appareils installés, soumis à une inspection initiale et vérifiés sous l autorité de la présente approbation conditionnelle peuvent nécessiter des modifications subséquentes par le requérant afin de les rendre conforme à toute nouvelle norme. ORIGINAL COPY SIGNED BY: Patrick J. Hardock, P.Eng. Senior Engineer Gas Measurement Engineering and Laboratory Services Directorate COPIE AUTHENIQUE SIGNEE PAR: Patrick J. Hardock, P.Eng. Ingénieur principal Mesure des gaz Direction de l ingénierie et des services de laboratoire Date: 2010-10-13 Web Site Address / Adresse du site Internet: http://mc.ic.gc.ca Page 17 of/de 17