Itron Canada Inc. 6507C Missisauga Road Mississauga, Ontario L5N 1A6. Itron Inc. 2401 North State Street Waseca, Minnesota USA 56093



Documents pareils
Maximum Capacity / Capacité maximal: 10 kg/min

Metretek Incorporated 305 East Drive, Suite A Melbourne, Florida, USA

Schneider Electric 19 Waterman Ave. Toronto, Ontario M4B 1Y2. Square D/Schneider Electric 295 Tech Park Drive LaVergne, TN USA

Mercury Instruments Inc Virginia Avenue Cincinnati, Ohio, USA Mercury Instruments Inc Virginia Avenue Cincinnati, Ohio, USA 45227

Kraft Fuels/Alternate Fuels Technology Inc. 50 Ritin Lane, Unit 20 Concord, Ontario L4K 4C9

Paxton. ins Net2 desktop reader USB

Itron Canada Inc. 6507C Mississauga Road Mississauga, Ontario L5N 1A6. Itron B North Highway 11 West Union, South Carolina, USA

Notice Technique / Technical Manual

Règlement relatif à l examen fait conformément à la Déclaration canadienne des droits. Canadian Bill of Rights Examination Regulations CODIFICATION

Fisher Controls International Inc South 17th Avenue Marshalltown, IA, USA

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

Fabricant. 2 terminals

Mercury Instruments Inc Virginia Avenue Cincinnati, Ohio, USA Mercury Instruments Inc Virginia Avenue Cincinnati, Ohio, USA 45227

Credit Note and Debit Note Information (GST/ HST) Regulations

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Daniel Industries Canada Inc. A Division of Emerson Process Management nd Avenue SE Calgary, Alberta T2C 2G5

Interest Rate for Customs Purposes Regulations. Règlement sur le taux d intérêt aux fins des douanes CONSOLIDATION CODIFICATION

Instructions Mozilla Thunderbird Page 1

Ships Elevator Regulations. Règlement sur les ascenseurs de navires CODIFICATION CONSOLIDATION. C.R.C., c C.R.C., ch. 1482

General Import Permit No. 13 Beef and Veal for Personal Use. Licence générale d importation n O 13 bœuf et veau pour usage personnel CONSOLIDATION

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

Calculation of Interest Regulations. Règlement sur le calcul des intérêts CONSOLIDATION CODIFICATION. Current to August 4, 2015 À jour au 4 août 2015

Contrôle d'accès Access control. Notice technique / Technical Manual

Life Companies Borrowing Regulations. Règlement sur les emprunts des sociétés d assurance-vie CONSOLIDATION CODIFICATION

Material Banking Group Percentage Regulations. Règlement fixant le pourcentage (groupe bancaire important) CONSOLIDATION CODIFICATION

Folio Case User s Guide

VTP. LAN Switching and Wireless Chapitre 4

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Order Binding Certain Agents of Her Majesty for the Purposes of Part 1 of the Personal Information Protection and Electronic Documents Act

Railway Operating Certificate Regulations. Règlement sur les certificats d exploitation de chemin de fer CODIFICATION CONSOLIDATION

Appointment or Deployment of Alternates Regulations. Règlement sur la nomination ou la mutation de remplaçants CONSOLIDATION CODIFICATION

Input Tax Credit Information (GST/HST) Regulations

Avis certifiant que des pays accordent les avantages du droit d auteur. Certification of Countries Granting Equal Copyright Protection Notice

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

Resident Canadian (Insurance Companies) Regulations. Règlement sur les résidents canadiens (sociétés d assurances) CONSOLIDATION CODIFICATION

Borrowing (Property and Casualty Companies and Marine Companies) Regulations

Short-term Pooled Investment Fund Regulations. Règlement sur le fonds commun de placement à court terme CONSOLIDATION CODIFICATION

Nordion Europe S.A. Incorporation Authorization Order. Décret autorisant la constitution de Nordion Europe S.A. CONSOLIDATION CODIFICATION

Form of Deeds Relating to Certain Successions of Cree and Naskapi Beneficiaries Regulations

BILL 203 PROJET DE LOI 203

Daniel Industries Canada Inc nd Avenue S.E. P.O. Box 727, Station T Calgary, AB T2H 2H2

Contents Windows

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

Embases pour raccordement G1/8 - G1/4

PART II / PARTIE II Volume 31, No. 11 / Volume 31, n o 11

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

DECLARATION OF PERFORMANCE. No DoP_FAC_003

Air Transportation Tax Order, Décret de 1995 sur la taxe de transport aérien CONSOLIDATION CODIFICATION

Disclosure on Account Opening by Telephone Request (Trust and Loan Companies) Regulations

Garage Door Monitor Model 829LM

Archived Content. Contenu archivé

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

TERRITOIRES DU NORD-OUEST RÈGLEMENT SUR LA FORMULE DE NOTIFICATION R FORM OF NOTIFICATION REGULATIONS R

Règlement sur les baux visés à la Loi no 1 de 1977 portant affectation de crédits. Appropriation Act No. 1, 1977, Leasing Regulations CODIFICATION

CONSOLIDATION CODIFICATION. Current to August 30, 2015 À jour au 30 août 2015

DOCUMENTATION - FRANCAIS... 2

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

DOCUMENTATION - FRANCAIS... 2

Fédération Internationale de Handball. b) Règlement du but

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Ordonnance sur le paiement à un enfant ou à une personne qui n est pas saine d esprit. Infant or Person of Unsound Mind Payment Order CODIFICATION

Critères à l attention des fabricants et des fournisseurs de biens ou de services : dispositifs mécaniques pour bingo

Name Use (Affiliates of Banks or Bank Holding Companies) Regulations

Import Allocation Regulations. Règlement sur les autorisations d importation CONSOLIDATION CODIFICATION

CODIFICATION CONSOLIDATION. Current to August 30, À jour au 30 août Last amended on December 12, 2013

APPENDIX 6 BONUS RING FORMAT

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

POLICY: FREE MILK PROGRAM CODE: CS-4

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

Lavatory Faucet. Instruction Manual. Questions?

Loi sur la Semaine nationale du don de sang. National Blood Donor Week Act CODIFICATION CONSOLIDATION. S.C. 2008, c. 4 L.C. 2008, ch.

Disclosure on Account Opening by Telephone Request (Retail Associations) Regulations

Order Assigning to the Minister of the Environment, the Administration, Management and Control of Certain Public Lands

If the corporation is or intends to become a registered charity as defined in the Income Tax Act, a copy of these documents must be sent to:

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Nouveautés printemps 2013

F1 Security Requirement Check List (SRCL)

de stabilisation financière

Practice Direction. Class Proceedings

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

THE LAW SOCIETY OF UPPER CANADA BY-LAW 19 [HANDLING OF MONEY AND OTHER PROPERTY] MOTION TO BE MOVED AT THE MEETING OF CONVOCATION ON JANUARY 24, 2002

OFFICIAL STATUS OF CONSOLIDATIONS CARACTÈRE OFFICIEL DES CODIFICATIONS

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

Loi sur l aide financière à la Banque Commerciale du Canada. Canadian Commercial Bank Financial Assistance Act CODIFICATION CONSOLIDATION

Exercices sur SQL server 2000

Guide d'installation rapide TFM-560X YO.13

Export Permit (Steel Monitoring) Regulations. Règlement sur les licences d exportation (surveillance de l acier) CONSOLIDATION CODIFICATION

INDIVIDUALS AND LEGAL ENTITIES: If the dividends have not been paid yet, you may be eligible for the simplified procedure.

22/09/2014 sur la base de 55,03 euros par action

RAPID Prenez le contrôle sur vos données

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

Z-Axis Compliance Device Compliance en z

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Transcription:

Measurement Canada An Agency of Industry Canada Mesures Canada Un organisme d Industrie Canada NOTICE OF APPROVAL Issued by statutory authority of the Minister of Industry for: AVIS D APPROBATION Émis en vertu du pouvoir statutaire du ministre de l Industrie pour : TYPE OF DEVICE Electronic Volume Transponder (Encoder/Receiver/Transmitter) APPLICANT TYPE D APPAREIL Transpondeur électronique de volume (encodeur/récepteur/transmetteur) REQUÉRANT Itron Canada Inc. 6507C Missisauga Road Mississauga, Ontario L5N 1A6 MANUFACTURER FABRICANT Itron Inc. 2401 North State Street Waseca, Minnesota USA 56093 MODEL(S)/MODÈLE(S) 40G ERT ERT 40G REMOTE ERT REMOTE ERT RATING/CLASSEMENT See "Summary Description"/Voir «Description sommaire» Page 1 of/de 18

NOTE: This approval applies only to meters, the design, composition, construction and performance of which are, in every material respect, identical to that described in the material submitted, and that are typified by samples submitted by the applicant for evaluation for approval in accordance with sections 13 and 14 of the Electricity and Gas Inspection Regulations. The following is a summary of the principal features only. REMARQUE : Cette approbation ne vise que les compteurs dont la conception, la composition, la construction et le rendement sont identiques, en tout point, à ceux qui sont décrits dans la documentation reçue et pour lesquels des échantillons représentatifs ont été fournis par le requérant aux fins d évaluation, conformément aux articles 13 et 14 du Règlement sur l inspection de l électricité et du gaz. Ce qui suit est une brève description de leurs principales caractéristiques. SUMMARY DESCRIPTION: DESCRIPTION SOMMAIRE : The Itron model 40G or ERT (direct mount) and/or 40G or REMOTE (remote mount) is a combination automatic meter reader and an electronic transponder. The ERT transmits the meter reading over a radio frequency to a mobile, handheld or fixed network data collection device. This meter reading can be used for billing purposes. Wake-up and Bubble-up Modes The B in the model number denotes a feature entitled bubble-up. The ERT and REMOTE ERT can be programmed in either wake-up or bubble-up mode: In bubble-up mode, the automatic meter reading device wakes up every 15 seconds and transmits its information to a mobile computer. In wake-up mode, the automatic meter reading device has to be polled before it can wake up and transmit data..the models 40G ERT and 40G REMOTE ERT (without the B ) can only operate in wake-up mode. Les modèles Itron 40G ou ERT (montage direct) et/ou 40G ou REMOTE (montage à distance) combinent un lecteur automatique de compteur et un transpondeur électronique. L ERT transmet la lecture d un compteur par fréquence radio à un appareil de cueillette de données réseaux fixe, mobile ou de poche. Ce lecteur de compteur peut également être utilisé à des fins de facturation. Modes d éveil provoqué et d éveil programmé Le «B» du numéro du modèle correspond à la caractéristique «éveil programmé». Les modèles ERT et REMOTE ERT peuvent être réglés en mode «éveil provoqué» ou en mode «éveil programmé». En mode «éveil programmé», le lecteur automatique de compteur s éveille toutes les 15 secondes et transmet l information à un ordinateur mobile. En mode «éveil provoqué», le lecteur automatique doit être interrogé avant de réagir et de transmettre les données. Les modèles 40G ERT et 40G REMOTE ERT (sans le «B») peuvent uniquement être utilisés en mode «éveil provoqué». Page 2 of/de 18

Direct Mount When installed on a diaphragm meter, the model 40G or ERT is installed between the host meter and its index and adapts to the host meter with the ERT s own plastic base and register cover. Cork gaskets seal the components together as well as to the meter. When installed on a rotary meter, the model 40G or ERT is installed as described in the respective Notice of Approval using an approved AMR adapter. Remote Mount A 3 wire cable (white +, red - and blue tamper wire) from the 40G or Remote ERT is attached to the test dial of the mechanical register or connected to a pulse transmitter or a Mercury conversion device (refer to Itron s installation manual, Installing the 40G and Remote ERT Module on Mercury Correctors, PUB-0071-501). The ERT counts one pulse per revolution of the test dial generated by the initiator / magnetic switch from the meter s register or counts one pulse for every pulse received from a meter, pulse transmitter or a Mercury conversion device of the type specified below. Programming The ERT can be programmed with a hand held device, the Itron s ReadOne Pro or FC200. Upon installation, the Itron 40G or ERT (direct or remote mount) is programmed to match the initial reading on the device s index. The ERT has three different lock levels for securing program information (levels 1, 2 and 3). ONLY LOCK LEVEL 3 IS APPROVED FOR USE. Upon installation, the ERT must be programmed to Lock Level 3. Montage direct Lorsqu installé sur un compteur à parois déformables, le modèle 40G ou ERT est installé entre le compteur principal et son indicateur et se fixe au compteur principal par l'entremise du socle en plastique et du couvercle de l enregistreur de l ERT. Les composants sont scellés les uns aux autres et au compteur par des garnitures d'étanchéité en liège. Lorsqu installé sur un compteur à pistons rotatifs, le modèle 40G ou ERT est installé selon les exigences décrites dans les avis d approbation appropriés au moyen d un adaptateur LAC. Montage à distance Un câble à 3 fils (fil blanc +, rouge - et un fil antisabotage) du modèle 40G ou REMOTE ERT est fixé au cadran de contrôle de l'enregistreur mécanique ou rattaché à un émetteur d impulsions ou à un dispositif de conversion Mercury (consulter le guide d installation de Itron «Installing the 40G and Remote ERT Module on Mercury Correctors», PUB-0071-501. L ERT compte une impulsion par révolution du cadran de contrôle produite par le commutateur magnétique ou l amorceur de l enregistreur du compteur ou compte une impulsion pour chaque impulsion reçue d un compteur, d un émetteur d impulsions ou d un dispositif de conversion Mercury des types précisés ci-dessous. Programmation L ERT peut être programmé à l aide d un dispositif de poche, le ReadOne Pro de Itron ou le FC200. Lors de l'installation, le modèle Itron 40G ou ERT (montage direct ou montage à distance) est programmé pour correspondre à la lecture initiale de l'indicateur du compteur. Le ERT comporte trois mécanismes de verrouillage différents pour protéger l information des programmes (niveaux 1, 2 et 3). SEUL LE NIVEAU 3 EST APPROUVÉ AUX FINS D UTILISATION. Lors de l installation, l ERT doit être programmé pour verrouiller le niveau 3. Page 3 of/de 18

With Lock Level 3, the ERT unit cannot be reprogrammed until the ERT Unit is powered down and reset to default settings. This requires breaking the seal and disconnecting and reconnecting the battery on the ERT unit. Housing The housing of the Itron/Metscan model 40G Remote has increased in volume to about double the original size. It is now roughly 11.4 cm x 11.4cm x 2.5 cm. The ERT can be used with the following meter types and models: Avec le verrouillage de niveau 3, l unité ERT ne peut pas être reprogrammée tant qu elle n est pas mise hors circuit et réinitialisée selon les paramètres par défaut. Cette opération requiert le bris du sceau, et le débranchement et le rebranchement de la pile de l unité ERT. Boîtier La taille du boîtier du modèle 40G REMOTE ERT de Itron/Metscan a presque doublé par rapport à sa taille d origine et mesure maintenant environ 11,4 cm sur 11,4 cm sur 2,5 cm. Le ERT peut être utilisé avec les modèles et types des compteurs suivants : Page 4 of/de 18

Compatibility Table/Tableau de compatibilité Device Manufacturer/ Fabricant de l appareil Model/Modèle ERT Type/ Type d ERT ERT mount type/ Type de montage de l ERT ERT Part Number/ Numéro de pièce de l ERT Actaris/Schlumberger/ Sprague METRIS 250 (Slant Face)/(Face oblique), 175, 240, 250 40G Direct/Direct ERG-0006-011, ERG-0006-211, ERG-1006-211, 248-2517-832, 248-2517-842 PR* ERG-1006-511 ERG-1006-513 American Meter Company AL-175, AC-175, AL-225, AL-250, AR-250, AC-250, AL-425, AC-630, 5B-225, RPM Rotary (CMTC)/ RPM à pistons rotatifs (CMTC) 40G Direct/Direct ERG-0006-001, ERG-1006-201, 248-2517-830 40G PR* ERG-0005-001, ERG-0006-003, ERG-0006-203, ERG-1006-203 ERG-1006-501 AL800, AL1000, AL1400, AL2300, AL5000 PR* 40G ERG-1006-503 ERG-0006-215, ERG-1006-215, 248-2517-840 ERG-1006-515 Dresser B series with B3 module/série B avec module B3, LM-MA (as approved by G- 0026 & G-0282/(approuvés par G-0026 et G-0282) 40G Remote/À distance ERG-0003-005, ERG-0003-006, ERG-0007-003, 248-2517-976, 248-2517-978, ERG- 1007-003 ERG-1007-503 Mercury B series with B3 module using Adapter Patent # 7059200/Série B avec module B3 utilisant un adapteur dont le n o de brevet est 7059200 MERCOR-EC Series/Série MERCOR-EC, Mini-AT, Mini-Max PR* Direct/Direct ERG-1006-503 40G Remote/À distance ERG-1007-005, ERG-1007-006 ERG-1007-505, ERG-1007-506 ROMET ECM2 Remote/À distance ERG-1007-507 Page 5 of/de 18

Device Manufacturer/ Fabricant de l appareil Model/Modèle ERT Type/ Type d ERT ERT mount type/ Type de montage de l ERT ERT Part Number/ Numéro de pièce de l ERT Sensus/Invensys/ Equimeter/Rockwell R-275 40G Direct/Direct ERG-0006-004, ERG-0006-204, ERG-1006-204, 248-2517-831, 248-2517-975 40G PR* PR* ERG-0005-002, ERG-0006-007, ERG-0006-207, ERG-1006-207 ERG-1006-504 ERG-1006-507 415 40G ERG-0006-005, ERG-0006-205, ERG-1006-205, 248-2517-838 40G PR* PR* ERG-0005-004, ERG-0006-009, ERG-0006-209, ERG-1006-209 ERG-1006-505 ERG-1006-509 MR-8, MR-12 40G ERG-0006-206, ERG-1006-206, 248-2517-843 PR* ERG-1006-506 ERG-1006-508 Sonix 6 40G Direct/Direct ERG-1007-004 ERG-1007-504 Sonix 12, 16 & 25 40G Direct/Direct ERG-1007-003 ERG-1007-503 Remote/À distance ERG-1007-507 * PR - passive radiator/radiateur passif Page 6 of/de 18

Radio Frequency SPECIFICATIONS Receiver Frequency: 952-956 MHz Transmitter Frequency: 910-920 MHz Power Supply 1 lithium A cell (for all ERTs except the following) 1 or 2 lithium A cells (for part numbers ERG- 1007-505, ERG-1007-506 and ERG-1007-507) average battery life: 14 to 20 years (for 1 or 2 batteries) exempt from battery specification 3-4.1 of LMB- EG-08 Programmable Parameters index reading test hand multiplier index roll over pressure compensation security flags wake-up or bubble-up mode Operating Humidity Range 5% RH to 95% RH Operating Temperature Range -30 C to 70 C (declared by manufacturer) -30 C to 40 C (tested by Measurement Canada) Radiofréquence CARACTÉRISTIQUES Fréquence du récepteur : 952-956 MHz Fréquence du transmetteur : 910-920 MHz Pile d alimentation 1 pile A au lithium (pour tous les ERT à l exception des suivants :) 1 ou 2 piles A au lithium (pour les numéros de pièce ERG-1007-505, ERG-1007-506 et ERG- 1007-507) durée de vie moyenne de la pile : de 14 à 20 ans (pour 1 ou 2 piles) exempté de la caractéristique 3-4.1 sur la pile d alimentation de la norme LMB-EG-08 Paramètres programmables relevé de l'indicateur multiplicateur d'essai de poche réinitialisation de l'indicateur compensation de la pression indicateurs de sécurité mode «éveil provoqué» ou mode «éveil programmé» Plage d'humidité relative de service humidité relative : de 5 % à 95 % Plage de température de service de -30 à 70 C (déclarée par le fabricant) de -30 à 40 C (testée par Mesures Canada) Page 7 of/de 18

Product Identification Identification du produit serial number (also called ERT and/or ID number) and bar code part number (determines which device the ERT is compatible with as well as battery capacity, maximum pulse frequency and cable length) Construction Material polyethermide plastic Signal inputs Form A Dry contacts Maximum Count Rate / Frequency 0.67 seconds per revolution equivalent to 1.49 Hz (for all ERTs except the following) 2.78 Hz (for part numbers ERG-1007-003, ERG-1007-005, ERG-1007-006, ERG-1007-505, ERG-1007-506 and ERG-1007-507) 5 Hz (for part number ERG-1007-503) numéro de série (également appelé ERT et/ou numéro d identification) et code à barres numéro de pièce (détermine le type d appareil avec lequel l ERT est compatible de même que la capacité de la pile, la fréquence d impulsions maximale et la longueur du câble) Matériau de fabrication polyéthermide Entrée de signaux forme A contacts secs Vitesse de comptage maximale/fréquence 0,67 seconde par révolution équivalent à 1,49 Hz (pour tous les ERT à l exception des suivants : ) 2,78 Hz (pour les numéros de pièce ERG- 1007-003, ERG-1007-005, ERG- 1007-006, ERG-1007-505, ERG- 1007-506 et ERG-1007-507) 5 Hz (pour le numéro de pièce ERG- 1007-503) Page 8 of/de 18

Duty Cycle Facteur d utilisation For part numbers ERG-1007-003, ERG-1007-005, ERG-1007-006, ERG-1007-505, ERG-1007-506 and ERG-1007-507: minimum off time: 280 ms minimum on time: 8 ms For part number ERG-1007-503: minimum off time: 200 ms minimum on time: 8 ms For all others, duty cycle is 50%. Firmware ICS-0025-005 (for 40G ERT and 40G REMOTE ERT) ICS-0025-007 (for ERT and REMOTE ERT) (printed on firmware chip) SEALING When installed on a diaphragm meter, the Itron 40G or ERT (direct mount) can be sealed in the same manner as the original register cover was sealed. Access to the register is prevented when wire is passed through drilled head screws and connected with a lead seal or through the use of screws and seal caps. When installed on a rotary meter, the Itron 40G or ERT (direct mount) can be sealed to an approved adaptor plate using seal plugs. Pour les numéros de pièces ERG-1007-003, ERG- 1007-005, ERG-1007-006, ERG-1007-505, ERG- 1007-506 et ERG-1007-507 : temps d inutilisation minimal : 280 ms. temps d utilisation minimal : 8 ms Pour le numéro de pièce ERG-1007-503 : temps d inutilisation minimal : 200 ms temps d utilisation minimal : 8 ms Pour tous les autres numéros de pièces, le facteur d utilisation est de 50 %. Microprogramme ICS-0025-005 (pour 40G ERT et 40G REMOTE ERT) ICS-0025-007 (pour ERT et REMOTE ERT) (imprimé sur une puce du microprogramme) SCELLAGE Lorsqu installé sur un compteur à parois déformables, le modèle 40G ou ERT (montage direct) de Itron peut être scellé de la façon utilisée pour le couvercle de l'enregistreur d'origine. L'accès à l'enregistreur est interdit lorsque le fil métallique passe dans la tête percée des vis pour être relié à un plomb de sécurité ou lorsque des vis et des raccords de scellage sont utilisés. Lorsqu installé sur un compteur à pistons rotatifs, le modèle 40G ou ERT (montage direct) de Itron peut être scellé à une plaque d adaptation approuvée au moyen de raccords d étanchéité. Page 9 of/de 18

The Itron 40G or REMOTE ERT is mounted on a flat surface, either a wall or an adaptor for pipe mounting. It can then be sealed externally by two red seal plugs. The ERT s 3 wire cable is attached to the test dial of the mechanical register or connected to a pulse generator or a Mercury electronic conversion device which is sealed. Upon installation, the programmable parameter security flags of the ERT must be set to Lock Level 3. Subsequent re-programming is not possible without breaking the seal and re-setting the unit by disconnecting and reconnecting the power supply. NAMEPLATE MARKINGS Marking requirements shall be in accordance with Sections 3-5.1 a, b, c and e (with the change noted below), 3-5.2 and 21-2.4 a, c, d, and e (with the exceptions noted) of LMB-EG-08. 3-5.1 c, Serial Number The ERT ID number is unique for each device and serves as both the ID and serial number (see Fig. 7). 21-2.4 c, Maximum Signal Input Voltage The maximum signal input voltage is not applicable as the ERT is designed to hook up to a register switch or contact that is described as dry (no voltage present). The ERT provides the potential and the switch at the register provides a conduction path. The ERT counts the switch closures. Le modèle 40G ou REMOTE ERT est monté sur une surface plane, soit un mur ou un adaptateur pour le raccordement de tuyaux. Il peut être scellé à l'extérieur à l'aide de deux raccords d étanchéité rouges. L ERT à 3 fils est fixé au cadran de contrôle de l'enregistreur mécanique ou rattaché à un dispositif de conversion électronique Mercury qui est scellé. Lors de l installation, le paramètre programmable «indicateurs de sécurité» de l ERT doit être programmé pour verrouiller le niveau 3. Pour effectuer toute reprogrammation subséquente, il faut briser le sceau et réinitialiser l'appareil en coupant et en rétablissant l'alimentation. MARQUAGES DE LA PLAGE SIGNALÉTIQUE Les exigences de marquage sont précisées dans les articles 3-5.1 a, b, c et e (le changement étant noté ci-dessous), 3-5.2 et 21-2.4 a, c, d et e (avec l exception signalée auparavant) de la norme LMB-EG-08. 3-5.1 c. Numéro de série Le numéro d identification de l ERT est unique pour chaque appareil et peut servir de numéro d identification et de numéro de série (voir la figure 7). 21-2.4 c, Tension maximale pour l entrée de signaux La tension maximale pour l entrée de signaux ne s applique pas compte tenu que l ERT est conçu pour être couplé avec un commutateur de registre ou des contacts secs (en l absence de tension). L ERT offre le potentiel et le commutateur de registre fournit un trajet conducteur. L ERT compte les fermetures du commutateur. Page 10 of/de 18

21-2.4 d, # Pulses per increment of volume The pulse weight (# cubic feet or cubic meters per pulse) is equal to the drive value that can be viewed on the display of the ReadOne Pro handheld unit. The # cubic feet or cubic meters per pulse can also be displayed by the FC200 handheld unit, with the Endpoint-Link software installed. The pulse weight is shown as Meter Configuration beside the # dials or drums that the meter has. 21-2.4 e, Units of registered quantity The units of registered quantity (i.e. cubic feet or cubic meters) can be viewed on the display of the ReadOne Pro or the FC200 handheld unit. NOTE: As of December 8' 1998 the model 40G Encoder/Receiver/Transmitter approved under AG-0327 under the applicant name of EnScan Inc. will be approved under AG-0371 Rev. 3 and any subsequent revisions thereof. The model 40G approved under AG- 0327 is identical in every respect as the device approved under AG-0371 except that the applicant and manufacturer is identified as EnScan Inc. MODIFICATION ACCEPTANCE LETTERS The following Modification Acceptance Letters are incorporated into this approval: MAL-G92 2000-11-03 MAL-G92 added a larger housing, coloured black for the 40G REMOTE ERT. MAL-G198 2005-10-18 MAL-G198 added the bubble-up models, ERT and REMOTE ERT. 21-2.4 d, Nombre d impulsions par augmentation du volume Le poids d impulsion (le nombre de pieds cubes ou de mètres cubes par impulsion) est égal à la valeur de l organe d entraînement que l on peut voir sur l affichage de l unité de poche ReadOne Pro. Le nombre de pieds cubes ou de mètres cubes peut également être affiché sur l unité de poche FC200 si le logiciel Endpoint-Link est installé. Le poids de l impulsion fait partie de la configuration du compteur au même titre que le nombre de cadrans ou de tambours que le compteur possède. 21-2.4 e, Unité de la grandeur enregistrée L unité de la grandeur enregistrée (c est-à-dire les pieds cubes ou les mètres cubes) apparaît sur l afficheur de l unité de poche ReadOne Pro ou FC200. NOTE : À compter du 8 décembre 1998, le codeur/récepteur/transmetteur, modèle 40G, approuvé en vertu de l'avis AG-0327, où le requérant EnScan Inc., sera approuvé en vertu de l'avis AG-0371, révision 3 et de toute révision subséquente. Le modèle 40G approuvé en vertu de l'avis AG-0327 est identique en tous points à l'appareil approuvé en vertu de l'avis AG-0371, sauf que le requérant et le fabricant sont EnScan Inc. LETTRES D ACCEPTATION DE MODIFICATION Les lettres d acceptation de modification suivantes sont intégrées au présent avis d approbation : LAM-G92 2000-11-03 LAM-G92 mentionne l augmentation de la taille du boîtier de couleur noire pour le modèle 40G REMOTE ERT. LAM-G198 2005-10-18 LAM-G198 mentionne l ajout des modèles ERT et REMOTE ERT en mode «éveil provoqué». Page 11 of/de 18

REVISION Date of original issue: 1994-03-23 Rev. 1 1996-07-29 The purpose of revision 1 was to include the Itron 40G ERT Remote unit under Approval Number AG- 0371. The 40G ERT and the 40G Remote ERT Unit show the same circuitry but the A.M.R. wiring of the Remote unit is relocated outside the register case. Rev. 2 1998-09-23 The purpose of revision 2 was to permit the use of the "level 2 soft lock" security feature by organizations accredited for its use by Measurement Canada and to change the address of the approval applicant and manufacturer. Rev. 3 1998-12-09 The purpose of revision 3 was to serve notice that the 40G ERT approved under AG-0327 will now be approved under AG-0371 and any subsequent revisions thereof. Rev. 4 Revision 4 adds the following: the remote versions of the ERT with a greater count rate/frequency and different duty cycles a compatibility table MAL-G92 and MAL-G198 updated Markings, Specifications and Sealing sections Rev. 1 David Lau Approvals Examiner Tel: (613) 952-0647 Fax: (613) 952-1754 EVALUATED BY RÉVISION Date de publication originale : 1994-03-23 Rév. 1 1996-07-29 La révision 1 visait à ajouter les appareils 40G REMOTE ERT de Itron dans l'avis d'approbation AG-0371. Les appareils 40G ERT et 40G REMOTE ERT ont les mêmes circuits, mais le câblage LAC de l unité à distance se trouve maintenant à l'extérieur du boîtier de l'enregistreur. Rév. 2 1998-09-23 Le but de la révision 2 était de permettre l utilisation du dispositif de sécurité du «verrouillage programmable de niveau 2» par des organismes accrédités par Mesures Canada ainsi que de changer l adresse du fabricant et du requérant de l approbation. Rév. 3 1998-12-09 Le but de la révision 3 était d annoncer que le modèle 40G ERT, visé par l Avis d approbation AG-0327, serait maintenant visé par l Avis d approbation AG-0371 et tiendrait compte de toutes les révisions subséquentes. Rév. 4 La révision 4 ajoute les points suivants : le modèle ERT REMOTE offre une plus grande vitesse de comptage/fréquence et divers facteurs d utilisation un tableau de compatiblité les lettres d acceptation de modification LAM- G92 et LAM-G198 la mise à jour des sections visant le marquage, les caractériques et le scellage ÉVALUÉ PAR Rév. 1 David Lau Examinateur d'approbations Tél. : 613-952-0647 Téléc. : 613-952-1754 Page 12 of/de 18

Rev. 2 & 3 Randy Byrtus Approvals Technical Coordinator Tel: (613) 952-0631 Fax: (613) 952-1754 Rev. 4 Judy Farwick Senior Legal Metrologist Tel: (613) 946-8185 Fax: (613) 952-1754 E-mail: farwick.judy@ic.gc.ca Rév. 2 et 3 Randy Byrtus Coordonnateur en Technologie - Approbation Tél. : 613-952-0631 Téléc. : 613-952-1754 Rév. 4 Judy Farwick Métrologiste légal principal Tel. : 613-946-8185 Télec. : 613-952-1754 Courriel : farwick.judy@ic.gc.ca Page 13 of/de 18

Figure 1 : 40G ERT/Modèle 40G ERT 40G ERT installed inside the register housing/installation du modèle 40G ERT à l intérieur du boîtier de l enregistreur. Page 14 of/de 18

Figure 2 : 40G REMOTE ERT, original housing/boîtier original du modèle 40G REMOTE ERT Figure 3 : 40G REMOTE ERT s 3 wire cable connection to Meter Register/ Connexion du câble à 3 fils du modèle 40G REMOTE ERT à l enregisteur du compteur Page 15 of/de 18

Figure 4 : 40G REMOTE ERT, larger black housing/ Plus grand boîtier de couleur noire du modèle 40G REMOTE ERT Figure 5: Inside the 40G Single Battery/ modèle 40G REMOTE REMOTE ERT with Intérieur du ERT à une pile Page 16 of/de 18

Figure 6: Inside the 40G REMOTE ERT with 2 Batteries/ Intérieur du modèle 40G REMOTE ERT à deux piles Figure 7: 40G REMOTE ERT for connection to Mercury Conversion Devices/ Connexion du 40G REMOTE ERT au dispositif de conversion Mercury ERT Part Number/ Numéro de pièces de l ERT Unique ERT ID Number/Identificateur unique de l ERT Page 17 of/de 18

APPROVAL: The design, composition, construction and performance of the meter type(s) identified herein have been evaluated in accordance with regulations and specifications established under the Electricity and Gas Inspection Act. Approval is hereby granted accordingly pursuant to subsection 9(4) of the said Act. The sealing, marking, installation, use and manner of use of meters are subject to inspection in accordance with regulations and specifications established under the Electricity and Gas Inspection Act. The sealing and marking requirements are set forth in specifications established pursuant to section 18 of the Electricity and Gas Inspection Regulations. Installation and use requirements are set forth in specifications established pursuant to section 12 of the Regulations. Verification of conformity is required in addition to this approval for all metering devices excepting instrument transformers. Inquiries regarding inspection and verification should be addressed to the local office of Measurement Canada. APPROBATION : La conception, la composition, la construction et le rendement du(des) type(s) de compteur(s) identifié(s) cidessus, ayant fait l objet d une évaluation conformément au Règlement et aux normes établis en vertu de la Loi sur l inspection de l électricité et du gaz, la présente approbation est accordée en application du paragraphe 9(4) de ladite Loi. Le scellage, l installation, le marquage, et l utilisation des compteurs sont soumis à l inspection conformément au Règlement et aux normes établis en vertu de la Loi sur l inspection de l électricité et du gaz. Les exigences de scellage et de marquage sont définies dans les prescriptions établis en vertu de l article 18 du Règlement sur l inspection de l électricité et du gaz. Les exigences d installation et d utilisation sont définies dans les prescriptions établis en vertu de l article 12 dudit règlement. En plus de cette approbation et sauf dans les cas des transformateurs de mesure, une vérification de conformité est requise. Toute question sur l inspection et la vérification de conformité doit être adressée au bureau local de Mesures Canada. Original signed by: Patrick J. Hardock, P.Eng. Senior Engineer Gas Measurement Engineering and Laboratory Services Directorate Copie authentique signée par : Patrick J. Hardock, P.Eng. Ingénieur principal Mesure des gaz Direction de l ingénierie et des services de laboratoire Date : 2007-05-10 Web Site Address/Adresse du site Internet: http://mc.ic.gc.ca Page 18 of/de 18