Network monitor for low voltage 4 module



Documents pareils
Network monitor for low voltage

Network monitor for low voltage 4 module

Centrales de mesures. CENTRALES DE MESURES Nemo. A.6 Guide de choix. A.14 4 Modules. A.20 Encastré 72x72. A.24 Encastré 96x96. A.

Insulation monitor for hospital use 4 module

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

Fabricant. 2 terminals

Fonctions intégrées. Nouvelles solutions universelles & système de communication

UMG 20CM. UMG 20CM Appareil de surveillance des circuits de distribution avec 20 entrées et RCM. Analyse d harmoniques RCM. Gestion d alarmes.

PVCHECK Rel /11/12

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Moteur DC: Comment faire varier sa vitesse?

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

Relais statiques SOLITRON MIDI, Commutation analogique, Multi Fonctions RJ1P

NPIH800 GENERATION & RESEAUX. PROTECTION de COURANT TERRE

Neu. Technique d installation / de surveillance. VARIMETER RCM Contrôleur différentiel type B IP 5883

Fiche technique CPU 314SC/DPM (314-6CG13)

Multitension Monofonction. Multitension Multifonction

MODULE DIN RELAIS TECHNICAL SPECIFICATIONS RM Basse tension : Voltage : Nominal 12 Vdc, Maximum 14 Vdc

MODULES ÉLECTRIQUES. - systèmes électriques DC - onduleurs - convertisseurs - interrupteurs statiques. Notre alimentation Votre confiance

100% électricité. Appareils de mesure numériques et transformateurs de courant

Spécifications d installation Précision des mesures

Relais d'arrêt d'urgence, protecteurs mobiles

sur le réseau de distribution

domovea tebis La maison sous contrôle

Contrôle d'accès Access control. Notice technique / Technical Manual

Module Relais de temporisation DC V, programmable

domovea tébis La maison sous contrôle

Notice technique. Système de surveillance MAS 711

Notice d'utilisation Afficheur multifonctions et système d'évaluation FX 360. Mode/Enter

POWER + SA Series 10kVA-40kVA & "POWER kVA-20kVA. Notre alimentation Votre confiance

Solutions pour la mesure. de courant et d énergie

Modules d automatismes simples

DIRIS D-30 DIRIS Digiware D-40 DIRIS Digiware D-50

TM238LDA24DR 230VAC - RELAYS OUTPUTS -

Paxton. ins Net2 desktop reader USB

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Surveillance de Scripts LUA et de réception d EVENT. avec LoriotPro Extended & Broadcast Edition

Description du logiciel Modbus RTU

Série 77 - Relais statiques modulaires 5A. Caractéristiques. Relais temporisés et relais de contrôle

Notice Technique / Technical Manual

Classes of protection IP 65 / IP66 / IP 67 ATEX zone protection Eex "ia" Eex "ed" Eex "em" ATEX II2 G/D

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

Power Management. Une vision fiable et précise des grandeurs électriques et de l énergie. Answers for industry.* Centrales de mesure SENTRON PAC

Pt 100 dispositif de commande TR 600 «Relais» avec deux sorties analogiques

T500 DUAlTACH. JAQUET T500 DualTach Instrument de mesure et de surveillance équipé de 2 entrées fréquence TACHYMETRE 2 CANAUX

Multifonction 1 NO Montage sur rail 35 mm (EN 60715)

08/07/2015

Technique de sécurité

BK 2515, BK 2516 DAS 50 DAS 30

Présentation et installation PCE-LOG V4 1-5

Exemple PLS avec SAS

Contrôle d accès Access control MOD-TCPIP-AI. Notice technique / Technical Manual

Références pour la commande

Relais d'arrêt d'urgence, protecteurs mobiles

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN 61303:1997

Garage Door Monitor Model 829LM

M2M La mesure de l'efficacité

Protect 5.31 Sortie monophasée 10kVA 120kVA Protect 5.33 Sortie triphasée 25kVA 120kVA. Alimentations Statique Sans Interruption

fonctions 1 NO Montage sur rail 35 mm (EN 60715) 16/30 (120 A - 5 ms) 16/30 (120 A - 5 ms) Tension nom./tension max.

Contrôle électronique pour chambres froides

Indicateur universel de procédé format 96 x 48 mm ( 1 /8 DIN)

Master4Light. Caractérisation Optique et Electrique des Sources Lumineuses. Equipement 2-en-1 : source de courant et spectrophotomètre

Relais statiques SOLITRON, 1 ou 2 pôles Avec dissipateur intégré

Système électronique de régulation et surveillance pour traçage et distribution électrique multicircuit à monter en armoire

DOCUMENTATION - FRANCAIS... 2

DimNet Gradateurs Numériques Evolués Compulite. CompuDim 2000

TRAITEMENT DE DONNÉES

Once the installation is complete, you can delete the temporary Zip files..

BAMOSONIC IT. - Mesure de niveau -

Vannes à boisseau sphérique Ball valves

Thermostate, Type KP. Fiche technique MAKING MODERN LIVING POSSIBLE

INdICAteur MISE EN SERVICE. INdICAteur. Afficheur déporté pour BAMOFLONIC PFA. MeS. Indicateur pour BAMOFLONIC /1. Code article :

WEBVIEW. Serveur Web embarqué dans DIRIS G NOTICE D UTILISATION. com/webview_ software

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

Exercices sur SQL server 2000

fullprotect inside EOLE SPEie RS E-SPEie V-0.6A-RS 1.0 revision Protection environnement Datasheet édition française

Embases pour raccordement G1/8 - G1/4

Système ASC unitaire triphasé. PowerScale kva Maximisez votre disponibilité avec PowerScale

I>~I.J 4j1.bJ1UlJ ~..;W:i 1U

Fiche technique CPU 315SN/PN (315-4PN33)

Compteurs d énergie iem3000

DOCUMENTATION - FRANCAIS... 2

ACS-30-EU-PCM2-x-32A Régulation et surveillance du traçage électrique des bâtiments commerciaux et résidentiels pour divers domaines d application

Z-Axis Compliance Device Compliance en z

Logiciel de gestion de l énergie. Technologie pour une énergie électrique efficace

ProCod. Manuel d utilisation. Software de programmation pour codeurs absolus TWK modèles CRF et DAF CRF DF 08 / 10

VTP. LAN Switching and Wireless Chapitre 4

CONTRÔLE DE BALISES TYPE TB-3 MANUEL D'INSTRUCTIONS. ( Cod ) (M H) ( M / 99G ) (c) CIRCUTOR S.A.

de mesure d intérieur

Guide d'installation rapide TFM-560X YO.13

TP TP4-20 GSM. Système d alarme sériel extensible. Les systèmes d alarme TP4-20 et TP4-20 GSM concilient la

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Centrale de surveillance ALS 04

0 20mV; 0 40mV; 0 80mV; 0 160mV; 0 320mV; 0 640mV; 0 1,28V; 0 2,56V 0 5V; 0 10V

T101, serveur de temps haute précision

Editing and managing Systems engineering processes at Snecma

AUDIT COMMITTEE: TERMS OF REFERENCE

Charge Force Poids. Highly Reliable Systems for Measuring and Monitoring Load, Force and Weight

INSTALLATIONS ÉLECTRIQUES CIVILES

Transcription:

ISTRUMETS DE MESURE MULTIMESURE MULTIMETERIG Centrale de mesure pour réseau basse tension modules KIT de mesure Rogowski Centrale de mesure multifonctions + 3 transformateurs de courant Rogowski Réseau triphasé 80...500 (-Phase) Raccordement sur transformateur de courant Rogowski dédié Rapport TT externe programmable Transformateur de courant externe programmable Energie active cl.1 (multifonction + transformateur de courant) Sortie impulsions Communication RS85 Diagnostic, correction séquence de Interfaces externes: Communication Ethernet (T809 - T891) etwork monitor for low voltage module Rogowski meausurement KIT etwork monitor + 3 Rogowski current sensors Three- network 80...500 (-) Connection on dedicated Rogowski current sensors Programmable external T ratio Programmable external current sensors ctive energy cl.1 (multifunction + current sensor) Pulse output RS85 communication Phase sequence correction, diagnostic External interfaces: Ethernet communication (T809 - T891) emo D-Le DISPL Rogowski IMPULSIOS PULSE RS85 ETHERET Tension et composée Phase and linked voltage Tension min. et max. Min. and max. voltage Courant et du neutre eutral and current Courant moyen et valeur max. du courant moyen Current demand and current max. demand réquence requency acteur de puissance Power factor Puissance ctive, reactive power 11E 50...290 /1 /5 3-1E 80...500 /1 /5 Puissance moyenne et valeur max. de la puissance moyenne Power demand and power max. demand L Energie totale et partielle, positive et négative active et réactive, Total and partial, positive and negative, active and reactive energy T889 09-2015 1 Ed. pag.1/10 31E 33E 80...500 80...500 /1 /5 /1 /5 3-2E 3-3E 80...500 80...500 /1 /5 /1 /5 Energie active tariffaire, tariffs Tariff active energy, tariff Heures et minutes de fonctionnement orking hours and minutes THD et THDI THD and THDI nalyse des Harmoniques Harmonic analysis acteur de crête tension et courant oltage and current crest factor ngle de entre courant et tension ngle de entre les courants ngle de entre les tensions Phase angle between current and voltage Phage angle between currents Phase angle between voltages Comptage impulsions, 2 entrées Pulse count, 2 input

MODELE MODEL emo D Le ETREE ICHGE DISPL USCITE OUTPUT COMUICZIOE COMMUICTIO RESEU ETORK bt / L Monophasé / Single- Triphasé, équilibré RCCORDEMET Three-, balanced load COECTIO Triphasé, non équilibré Three-, unbalanced load DIGOSTIC, CORRECTIO SEQUECE DE PHSE / PHSE SEQUECE CORRECTIO, DIGOSTIC LEUR OMILE Tension / oltage 100-00 RTED LUE Courant / Current ETREE COURT TC dédié / Dedicated CT CURRET Isolé / Insulated TT (kt) / T (kt) 1...10 Calibres / Ranges RPPORT PROGRMMLE TC/CT Ipn PROGRMMLE RTIO 1000-3000-5000 max. kt x kt / max. kt x kct 99 990 Shunt Précision / ccuracy E/IEC 61557-12 cl.1 EERGIE CTIE CTIE EERG EERGIE RECTIE RECTIE EERG TESIO OLTGE COURT CURRET CTEUR DE PUISSCE POER CTOR PUISSCE POER DISTORSIO HRMOIQUE Courant / Tension HRMOIC DISTORTIO Current / oltage Précision énergie dc Energy accuracy dc Positive, totale et partielle Positive, total and partial égative, totale / egative total Précision / ccuracy E/IEC 61557-12 cl.1 Positive, totale / Positive, total Positive, partielle / Positive, partial égative, totale / egative, total Simple et composée / Phase and linked Par et du neutre (calculé) Phase and neutral (computed) du neutre (mesuré) eutral (measured) Moyenne et moyenne max. Phase demand and max. demand Triphasé / Three- Par / Phase ctive, réactive, apparente ctive, reactive, apparent Moyenne et moyenne max. Demand and max. demand ctive et réactive Phase active and reactive THD nalyses / nalysis REQUECE / REQUEC MESURE C.C. 1 / D.C. 1 MESURE COMPTEUR HORIRE / RU HOUR METER SEQUECE DE PHSE ERROÉE / ROG PHSE SEQUECE TEMPERTURE / TEMPERTURE IMPULSIOS / PULSES RELIS LRMES / LRM RELS RELIS LRMES + ETREES UMERIQUES / LRM RELS + DIGITL S LOGIQUE / LOGUE RS232 RS85 MODUS RTU RS85 + MEMOIRE / RS85 + MEMOR PROIUS LOORKS M-US CET ETHERET RS85 + I2E011 TRSMISSIO RDIO 868MHz / 868MHz RDIO TRSMISSIO 1 Tension, courant, puissance, h positive et négative / 1 oltage, current, power, h positive and negative en alternative On choice en alternative On choice T889 09-2015 1 Ed. pag.2/10

REERECES ORDERIG CODE Rogowski sensor ETREE SORTIE OUTPUT LIM. U. U.SUPPL 9017 0203 80mm 9017 020 12mm 9017 0205 190mm 20...5000 80...500 Impulsion énergie / communication RS85 Pulse energy / RS85 communication 80...265ac 100...300dc COMPOSITIO KIT KIT COMPOSITIO 3 Transformateur Rogowski 3 Rogowski sensor 1 emo D-Le RogowskiRetrofit REERECE CODE DIMETRE DIMETER ETREE SORTI OUTPUT LIM. U. U.SUPPL 9017 0203 80mm 20...5000 80...500 9017 020 12mm 20...5000 Sensore Rogowski 9017 0205 190mm 20...5000 Sensor impulsions énergie communication RS85 energy pulse RS85 communication 80...265ca/ac 100...300cc/dc LEGEDE: = Paramètres programmables = Paramètres réinitialisables LEGED: = Programmable Parameter = Reset Parameter ICHGE DISPL Type d affichage: cristaux liquides rétroéclairés (LCD) Type of display: backlighted liquid crystal Rétroéclairage sélectionnable: 0 35 70 100% Selectable backlighting: 0 35 70 100% Réduction automatique du rétroéclairage (de la valeur sélectionnée), temporisation acklighting automatic reduction (to the selected value) after approximately 20 20 secondes d inactivité du clavier seconds of keyboard idle Rétroéclairage 100% à la pression sur le clavier 100% backlighting after first pressure on the keyboard bre de points d affichage: 10. 000 chiffres (hauteur des chiffres 12 mm) Reading points: 10.000 digits (digit height 12mm) Unités de mesures: affichage automatique en fonction des rapports TT et TC sélectionnés Engineering unit: automatic display according to the loaded T and CT ratios Résolution: automatique Resolution: automatic Point décimal: automatique Decimal point: automatic Mise à jour de la lecture : 1 lecture/s Display updating: 1 reading/s Comptage de l énergie: 8 chiffres Energy count: 8 digits L affichage est divisé en menus accessible à l aide des touches Display is subdivided into menus which are accessible through the relevant correspondantes : function keys: u i u pqs i etu pqs i uet pqs i etpqs et La page d affichage change selon la mesure programmée Display pages change according to the programmed measuring mode PRMETRES PROGRMMLES Programmation: par touches tactiles en façade, touches ccès à la programmation: protégé par un mot de passe Menu programmation: subdivisé en deux niveaux IEU 1 Page d affichage personnalisée Raccordement Temps d intégration courant/puissance moyenne ffichage rétroéclairage Démarrage du comptage du compteur Communication RS85 onction sortie relais impulsions ou alarme ou commutation état IEU 2 Mode de comptage de l énergie Rapport TT et courant nominal PROGRMMLE PRMETERS Programming: through touch-screen front keyboard, keys Programming access: password-protected Programming menu: subdivided on two levels LEEL 1 Customized display page Connection verage power/current delay time Display backlighting Lapsed time count start RS85 communication Relay output function pulses or alarm or state switching LEEL 2 Energy count mode External T ratio and current rating MODE DE COMPTGE DE L EERGIE EERG COUT MODE T889 09-2015 1 Ed. pag.3/10 modes sélectionnables : synchrone, asynchrone, tariff, comptage impulsions SCHROE Synchronus SCHROE synchronus TRI Tariff COMPTGE IMPULSIOS Pulse counting Comptage énergie partielle Partial Energy Count ctivé par entrées numériques ctivated by digital inpuls Toujours actif lways active -- Toujours actif lways active selectable modes: synchronous, asynchronous, tariff, pulse counting Energie Tariff Comptage impulsions Energy Tariffs Pulse Counter -- -- -- -- Commutation tarif avec entrées numériques Tariff switching with digital inputs -- ctivé par entrées numériques ctivated by digital inputs

ICHGE DES PGES RCCORDEMET 33E 33E COECTIO PGES DISPLIG SCHROE - SCHROE - COMPTGE IMPULSIOS SCHROOUS - SCHROOUS - PULSE COUTIG TRI TRI u i u pqs i u et pqs i u et pqs i et pqs et TESIO et composée OLTGE and linked COURT et du neutre CURRET and neutral PUISSCE TRIPHSEE, déformée 1 THREE-PHSE POER, distorting 1 CTEUR DE PUISSCE et triphasée POER CTOR and three- TESIO MIIMUM MIIMUM OLTGE COURT MOE CURRET DEMD PUISSCE PR PHSE PHSE POER GLE DE PHSE COURT-TESIO et triphasée PHSE GLE CURRET-OLTGE and three- TESIO MIMUM MIMUM OLTGE COURT MOE M. M. CURRET DEMD PUISSCE MOEE POER DEMD REQUECE REQUEC DISTORSIO HRMOIQUE TESIO et composée OLTGE HRMOIC DISTORTIO or linked MOEE DES 3 COURTS ERGE CURRET I1 + I2 + I3 3 PUISSCE MOEE M. M. POER DEMD COMPTEUR HORIRE RU HOUR METER LSE HRMOIQUES 2 et composée H03/05/07/09 HRMOIC LSIS 2 or linked DISTORSIO HRMOIQUE COURT CURRET HRMOIC DISTORTIO EERGIE CTIE TOTLE Positive et négative TOTL CTIE EERG Positive and egative CTEUR DE CRETE CREST CTOR LSE HRMOIQUES 2 H03/05/07/09 HRMOIC LSIS 2 EERGIE RECTIE TOTLE Positive et négative TOTL RECTIE EERG Positive and egative GLE DE PHSE fra le tensioni PHSE GLE between voltages CTEUR DE CRETE CREST CTOR EERGIE CTIE PRTIELLE Positive et négative PRTIL CTIE EERG Positive and egative GLE DE PHSE entre courants PHSE GLE between currents EERGIE RECTIE PRTIELLE Positive et négative PRTIL RECTIE EERG Positive and egative COMPTGE IMPULSIOS Etat du compteur d impulsions PULSE METERIG State of Pulse Input DISTORSIO PUISSCE DISTORTIG POER TESIO et composée OLTGE and linked COURT et du neutre CURRET and neutral PUISSCE TRIPHSEE, déformée 1 THREE-PHSE POER, distorting 1 CTEUR DE PUISSCE et triphasée POER CTOR and three- TESIO MIIMUM MIIMUM OLTGE COURT MOE CURRET DEMD PUISSCE PR PHSE PHSE POER GLE DE PHSE COURT-TESIO et triphasée PHSE GLE CURRET-OLTGE and three- TESIO MIMUM MIMUM OLTGE DISTORSIO HRMOIQUES TESIO et composée OLTGE HRMOIC DISTORTIO or linked COURT MOE M. M. CURRET DEMD MOEE DES 3 COURTS ERGE CURRET I1 + I2 + I3 3 PUISSCE MOEE POER DEMD PUISSCE MOEE M. tariff 1/2/3/ M. POER DEMD tariff1/2/3/ REQUECE REQUEC COMPTEUR HORIRE RU HOUR METER LSE DES HRMOIQUES 2 et composée H03/05/07/09 HRMOIC LSIS 2 or linked DISTORSIO HRMOIQUE COURT CURRET HRMOIC DISTORTIO EERGIE CTIE POSITIE POSITIE CTIE EERG CTEUR DE CRETE CREST CTOR LSE HRMOIQUE 2 H03/05/07/09 HRMOIC LSIS 2 EERGIE RECTIE POSITIE POSITIE RECTIE EERG GLE DE PHSE entre tensions PHSE GLE between voltages CTEUR DE CRETE CREST CTOR GLE DE PHSE entre courants PHSE GLE between currents EERGIE CTIE EGTIE EGTIE CTIE EERG EERGIE RECTIE EGTIE EGTIE RECTIE EERG EERGIE CTIE tariff 1/2/3/ CTIE EERG tariff1/2/3/ T889 09-2015 1 Ed. pag./10

1 Dans les systèmes triphasés, la relation entre P,Q et S est normalement la suivante : S = x I = P 2 + Q 2 Ceci s'applique en l'absence de distorsion d harmonique. S il existe des distorsions du courant, le rapport doit être corrigé comme suit: S = x I = P 2 + Q 2 + D 2 où D signifie puissance déformée. LSE HRMOIQUES 2 Le calcul du contenu d harmoniques du signal d entrée tient compte de la présence éventuelle des inter-harmoniques, qui généralement sont présentes lorsque la forme d onde est cycliquement interrompue. Dans ces cas, il n'y a pas d'harmoniques à des fréquences multiples de la fréquence fondamentale, mais au milieu de deux valeurs consécutives : ex.: 50Hz (fondamentale) inter-harmoniques: 87,5Hz (50-100Hz) ou 112,5Hz (100-150Hz) fin de présenter les données d'une manière standard, le contenu d harmonique, comme dans l exemple, est attribué correctement à l harmonique centrale la plus proche dans la plage 50...100Hz qui est 100Hz (seconde harmonique). 1 In normal 3- systems, usually the relationship between P,Q and S is as in the following: S = x I = P 2 + Q 2 This is true whwn no distortionis present in the currents. hen the currents have some way a harmonic contents, yhe formula must be corrected in this way: S = x I = P 2 + Q 2 + D 2 where D has the meaning deforming power. HRMOIC LSE 2 The calculation of the harmonic contents of the incoming signal keeps in account the possible presence of inter-harmonics that normally is found when the waveform is cyclically interrupted (burst fired). In these cases, there aren t any harmonics at frequencies multiple of the fundamental but in the ranges between two consecutive values: eg.: 50Hz (fundamental) inter-harmonics: 87,5Hz (50-100Hz) or 112,5Hz (100-150Hz) To show the results in a standard way, the harmonic contents, as in the example, are correctly attributed to the nearest central harmonic in the range 50...150Hz that is 100Hz (second harmonic). PRECISIO E COORMITE COORMIT CCURC ITH E/IEC 61557-12 Energie active ctive energy Ea cl.1 Energie réactive Reactive energy Erv cl.1 Tension oltage U cl.0,5 Courant Current I cl.0,5 Puissance active ctive power P cl.0,5 Puissance réactive Reactive power Qv cl.1 Puissance apparente pparent power Sv cl.1 réquence requence f ± 0,1Hz THD (jusqu au rang 50 ) THD (up to 50 th harmonic) Harmonique simple Harmonics single Mise à jour mesure : 5 lectures/sec Measuring updateing: 5 reading/sec THDu / THDi cl.1 ETREE Raccordement: réseau monophasé et triphasé 3 et fils Tension nominale Un: 00-100 (-) Tension triphasée : 80...500 (-) Tension monophasée nominale Un: 230 Tension monophasée : 50...290 Rapport TT externe: 1...10,0 (tension primaire max. TT 1200) Raccordement sur dédié Etendue de mesure: 20...1000-60...3000-100... 5000 La sortie du transformateur est un signal en m, sans danger pour les enroulements des secondaires ouverts réquence nominale fn: 50Hz - 00Hz (sélection automatique) ariation admissible: 5...65Hz (fn 50Hz) - 360...0Hz (fn 00Hz) Type de mesure: valeur efficace vraie RMS Contenu des harmoniques: jusqu au rang 0 (5...65Hz) acteur de crête courant: 2 Temps de démarrage (comptage de l énergie): < 5s utoconsommation tension: 0,2 (-neutre vers tension nominale) utoconsommation courant: nulle L'absence d'un noyau magnétique permet d'éviter l'absorption de courant du circuit de mesure Connection: single and three- network, 3 and -wire Three- voltage rating Un: 00-100 (-) Three- voltage: 80...500 (-) Single- voltage rating Un: 230 Single- voltage: 50...290 External T ratio: 1...10,0 (max. T primary 1200) Connection with Rogowski current sensor dedicated Measuring range: 20...1000-60...3000-100...5000 Sensor output is a m, signal without any danger for open secondary windings requency rating fn: 50Hz - 00Hz (automatic selection) Tolerance: 5...65Hz (fn 50Hz) - 360...0Hz (fn 00Hz) Type of measurement: true RMS value Harmonic content: up to 0 th harmonic (5...65) Current peak factor: 2 Start time (energy count): < 5s oltage rated burden: 0,2 (neutral- to voltage rating) Current rated burden: void The absence of a magnetic core allows to avoid absorption of power from the measuring circuit T889 09-2015 1 Ed. pag.5/10 ETREE UMERIQUES 2 entrées numériques actives, utilisables en fonction du mode de comptage sélectionné Synchrone: activation comptage énergie partielle active et/ou réctive synchrone: entrées numériques non utilisées Tariff: commutation tariff 1 / 2 / 3 / Comptage impulsions : comptage impulsions entreés 1 et 2 3 bornes d entrée avec point commun (bornes 23-2-25) Entrée tension max.: 27 réquence entrée impulsions max. : 15Hz DIGITL S 2 active digital inputs, with different use according to the selected count mode Synchronous: active and/or reactive partial energy count activation synchronous: unused digital inputs Tariff: tariff switching 1 / 2 / 3 / Pulse metering: pulse metering for input 1 and 2 3 input terminals with common point (terminals 23-2-25) Max. input voltage: 27 Max. input pulse frequency: 15Hz

PUISSCE MOEE POER DEMD Calcul: moyenne sur la période sélectionnée Quantity: active power Grandeur: puissance active Temporisation : 5/8/10/15/20/30/60 min. Calculation: average on the selected time interval Delay time: 5/8/10/15/20/30/60 min. Temps d intégration: unique pour toutes les grandeurs verage period: only for all quantity COMPTEUR HORIRE RU HOUR METER Comptage heures et minutes Départ du comptage : présence puissance ou tension sélectionnable Hours and minutes count Tension: -tension > 20 Puissance: puissance active triphasée nominale oltage: -voltage > 20 aleur programmable : 0,5...50%Pn Pn = puissance active tri. nominale = tension active tri. nominale Un x Courant In x 3 Programmable value: 0,5...50%Pn In = 1 ou. 5 Un = 00 Count start: power or voltage present selectable Power: 3- active power rating Un = 00 Pn = 3- active power rating = 3- active voltage rating Un x Current In x 3 Pn = 00 x 5 x 3 = 36 or. 00 x 1 x 3b = 692,8 In = 1 or. 5 SORTIE RELIS REL OUTPUT (commandé à distance) mode bistable, commutation état relais (commandé à Output function: energy pulses, alarm contact, state of relay switching (remote- distance) mode chronométré controlled), bistable mode, state of relay switching (remote-controlled), timed mode Sortie impulsions compatible avec S0 E/IEC 62053-31 EERG PULSE OUTPUT Pouvoir de coupure: 27dc/ac - 50m Optorelay with potential-free SPST-O contact SORTIE IMPULSIOS EERGIE Opto-relais avec contatct SPST-O libre de potentiel Energie associée: active ou réactive Pulse output compatible with S0 E/IEC 62053-31 Contact range: 27dc/ac 50m ssociated energy: active or reactive Poids de l impulsion : 1 impulsion/10h(varh) 100h(varh) - 1 kh(varh) eight of pulse: 1 pulse/10h(varh) - 100h(varh) 1kh(kvarh) - 10 kh(kvarh) 100kh(kvarh) 1Mh(kvarh) 10Mh(kvarh) 10kh(kvarh) - 100kh(kvarh) 1Mh(Mvarh) - 10Mh(Mvarh) LRME LRM Durée de l impulsion: 50 100 200-300 - 00-500ms 1 larme programmable Pulse duration: 50 100 200 300 00 500ms En cas d intervention de l alarme, l affichage clignote pour signaler l anomalie. En 1 Programmable alarm a l alarme ainsi que le type d alarme (min. ou max.) y pressing many times et key it is possible to display the quantity coupled with the Pouvoir de coupure : 27dc/ac - 50m Optorelay with potential-free SPST-O contact appuyant plusieurs fois sur la touhe et il est possible d afficher la grandeur associée In case an alarm occurred, the display is blinking to signal the anomaly. Opto-relais avec contact SPST-O libre de potentiel alarm as well as the alarm type (min. or max.) Grandeurs associables: tension - / - / - Contact range: 27dc/ac 50m Quantities that can be associated: tension composée - / - / - voltage - / - / - fréquence currenti1 / I2 / I3 puissance réactive triphasée 3- active power courant I1 / I2 / I3 interlinked voltage - / - / - puissance active triphasée frequency Seuil d intervention Type d alarme : min. or max. Contact relais sortie : normallement ouvert ou normallement fermé 3- reactive power Intervention threshold Type alarm: min. or max. Hystérésis : 0-20% Relay output contact: normally open or normarmally closed Délai de réarmemement : 0,99s Intervention delay: 0...99s Délai d intervention : 0,99s Etat commutation relais (commandé à distance), mode bistable Contact sortie relais: normallement ouvert (no) ou normallement fermé (nc) Hysteresis: 0...20% Reset delay: 0...99s State of relay switching (remote-controlled), bistable mode t on: délai entre l activation à distance et changement d état du relais Relay output contact: normally open (no) or normally closed (nc) aleur sélectionnabes t on / t o : 0,99s t o: delay between reset remote control and change of state of relay t o : délai entre le reset à distance et le changement de statut du relais Etat commutation relais (commandé à distance), mode chronométré Contact sortie relais: normallement ouvert (no) ou normallement fermé (nc) t on: delay between activation remote control and change of state of relay Selectable values t on / t o: 0 99s State of relay switching (remote-controlled), timed mode t on: délai entre l activation à distance et changement d état du relais Relay output contact: normally open (no) or normally closed (nc) aleur sélectionnabes t on / t o : 0,99s t o: delay between change of state of relay (activation) and reset t o : délai entre le changement d état du relais (activation) et le reset t on: delay between activation remote control and change of state of relay Selectable values t on / t o: 0 99s T889 09-2015 1 Ed. pag.6/10 onction sortie: impulsions énergie, contact alarme, commutation état relais Pn = 00 x 5 x 3 = 36 or. 00 x 1 x 3 = 692,8

DIGOSTIC, CORRECTIO SEQUECE DE PHSE IME a rajouté un algorithme pour détecter et corriger de nombreux problèmes liés au raccordement tension et / ou courant. Cette fonction peut être activée par un mot de passe et permet d afficher et de modifier, via software, la séquence de raccordement pour autant que les conditions suivantes soient remplies: 1) fil du neutre (dans un réseau fils) est raccordé à la borne correspondante (normalement numéro 11). 2) Pas de croisements entre les câbles raccordés aux TC (ex.: sur la 1 de l'appareil éviter un câble provenant de TC1 et un câble provenant de TC2) 3) Le facteur de puissance et compris entre 1 et 0,5 inductif pour chacune des s. voir www.imeitaly.com SUPPORTO TECICO. PHSE SEQUECE CORRECTIO, DIGOSTIC In the software of the device IME have added a specific functionality to detect and correct many problems concerning voltage and / or current connection. This function can be activated through password and allows to display and modify the connection sequence provided that the following conditions are respected: 1) The neutral wire (in a -wire network) is connected to the right terminal (normally number 11). 2) o crossings between cables connected to CTs (e.g. avoid that on 1 of the meter -terminals 1 and 3 - are connected some way both to CT1 and CT2). 3) The power factor is between 1 and 0,5 - Inductive load - for each. See www.imeitaly.com TECHICL SUPPORT. COMMUICTIO RS85 Modbus Isolée galvaniquement de l entrée et de l alimentation auxiliaire Standard: RS85-3 fils Transmission: asynchrone série Protocole: Modbus RTU - Modbus TCP (reconnaissance automatique) ombre d adresse : 1...255 ombre de bits: 8 it de stop: 8 it de parité: sans - paire - impair Temps de réponse à l interrogation: 3...100ms itesse de transmission : 800-9 600-19 200-38 00 bit/second Message Modbus format ord: ig Endian, Little Endian, Swap Exemple Message demande: 01 03 10 00 00 02 CO C Réponse: ig Endian = 01 03 0 01 02 03 0 C Little Endian = 01 03 0 0 03 02 01 C Swap = 01 03 0 03 0 01 02 C bre max. d appareils raccordés au réseau: 32 (jusqu à 255 avec répétiteur RS85) Distance max. du superviseur: 1200m Modbus RS85 COMMUICTIO Galvanically insulated from input and auxiliary supply Standard: RS85 3 wires Transmission: serial asynchronous Protocol: Modbus RTU Modbus TCP (autorecognition) umber of address: 1...255 umber of bits: 8 Stop bit: 8 Parity bit: none even odd nswer waiting time: 3...100ms Transmission speed: '800 9'600 19'200 38'00 bit/second Modbus word message format: ig Endian, Little Endian, Swap Example Request message: 01 03 10 00 00 02 C0 C Risposta: ig Endian = 01 03 0 01 02 03 0 C Little Endian = 01 03 0 0 03 02 01 C Swap = 01 03 0 03 0 01 02 C Max. number of devices that can be network-connected: 32 (up to 255 with RS85 repeator) Max. distance from the supervisor: 1200m COMMUICTIO RS85 CET Isolée galvaniquement de l entrée et de l alimentation auxiliaire Standard: RS85-3 fils Transmission: asynchrone série Protocole: CET MS-TP ombre d adresse: 0...127 itesse de transmission: 9'600 19'200 38'00 76 800 bit/s ombre de bits: 8 it de stop: 8 it de parité: sans - paire - impair dresse du réseau: 0...000 bre max. d appareils raccordés au réseau: 32 (jusqu à 255 avec répétiteur RS85) Distance max. du superviseur: 1200m CET RS85 COMMUICTIO Galvanically insulated from input and auxiliary supply Standard: RS85 3 wires Transmission: serial asynchronous Protocol: CET MS-TP umber address: 0...127 Trasmission speed: 9'600 19'200 38'00 76 800 bit/s umber of bits: 8 Stop IT: 8 Parity: none even odd etwork address: 0...000 Max. number of devices that can be network-connected: 32 (up to 255 with RS85 repeator) Max. distance from the supervisor: 1200m COMMUICTIO ETHERET (T809) Réalisable avec les interfaces I2E011 ou I2E111 ou IE011 (RS85/Ethernet) ETHERET COMMUICTIO (T809) It can be carried out with I2E011 or I2E111 or IE011 (RS85/Ethernet) interface LIMETTIO UILIIRE UILIR SUPPL T889 09-2015 1 Ed. pag.7/10 aleur nominale Uaux ac: 80...265ac - 8ac réquence nominale fn: 50 ou 00Hz (sélection automatique) réquence de fonctionnement: 5 65Hz (fn 50Hz) ou 360...0Hz (fn 00Hz) utoconsommation: 2,5 (230ca backlight 30%) aleur nominale Uaux cc: 100...300dc - 20...60dc utoconsommation: 2,5 (2dc backlight 30%) Protection contre l inversion de polarité COMPTIILITE ELECTROMGETIQUE Emission selon E / IEC 61326-1 classe Immunité selon E / IEC 61326-1 Rated value Uaux ac: 80...265ac - 8ac Rated frequency fn: 50 or 00Hz (automatic selection) orking frequency: 5 65Hz (fn 50Hz) or 360...0Hz (fn 00Hz) Rated burden: 2,5 (230ac backlight 30%) Rated value Uaux dc: 100...300dc - 20...60dc Rated burden: 2,5 (2dc backlight 30%) Protected against incorrect polarity ELETROMMGETIC COMPTIILIT Emission according to E 61326-1 class Immunity according to E 61326-1

ISOLEMET (E/IEC 61010-1) Catégorie de l installation: III Degré de pollution: 2 Tension de référence pour l isolement: emo D-Le: 300 ( - neutre) Tension de référence pour l isolement: : 1000 ISULTIO (E/IEC 61010-1) Installation category: III Pollution degree: 2 Insulation voltage rating emo D-Le: 300 (Phase - neutral) Insulation voltage rating...: 1000 Circuits considérés Considered circuits Tension d essai impulsions normalisées 1,2 / 0μs0,5J oltage test 1,2 / 50μs 0,5J PROE TESTS Tension alternative valeur r.m.s 50Hz 1min lternating voltage r.m.s value 50Hz 1min limentation / Entrées voltmétriques Supply / oltmetric inputs 6k 3k Entrées mesure / Communication RS85 Measure inputs / RS85Communication 6k 3k Entrées mesure / Sorties impulsions Meaure inputs / Pulse output 6k 3k emo D-Le Tous les circuits et la masse ll circuits and earth - k Tous les circuits et la masse ll circuits and earth - 7,k CODITIOS D UTILISTIO Température de référence: 23 C ± 2 C Température de fonctionnement spécifique: -5...55 C Température limite pour le stockage et le transport: - 25...70 C dapté pour l utilisation en climat tropical Puissance max. dissipée 1 : 5 1 Pour le dimensionnement thermique du coffret Température de référence: 23 C ± 2 C Température de fonctionnement spécifique: -30...80 C Température limite pour le stockage et le transport: - 0...80 C EIROMETL CODITIOS Reference temperature: 23 C ± 2 C Specified operating range: -5...55 C Limit range for storage and transport: - 25...70 C Suitable for tropical climates Max. power dissipation 1 : 5 1 or switchboard thermal calculation. Reference temperature: 23 C ± 2 C Specified operating range: -30...80 C Limit range for storage and transport: - 0...80 C OITIER Centrale de mesures multifonctions emo D-Le oîtier : modules DI 3880 Montage: rail 35mm Type de profil: TH35-15 (E60715) Matériau du boîtier: polycarbonate autoextinguible Degré de protection (E60529): IP5 face avant, IP20 bornes Poids: 250 grammes ixation du transformateur: baïonnette Raccordement: fil avec embout Longueur du câbe: 3m Matériau du boîtier: polyuréthane thermoplastique UL9-0 Degré de protection (E60529): IP67 Poids: 500 grammes (max.) HOUSIG emo D-Le Mutifunction Housing: moduli DI 3880 Mounting: snap-on 35mm rail Rail type: top hat TH35-15 (E60715) Housing material: self-extinguishing policarbonate Protection degree (E60529): IP5 front frame, IP20 terminals eight: 250 grams Sensor Sensor fastening: bayonet holder Connections: cable with lag Cable lenght: 3m Housing material: UL9-0 thermoplastic polyurethane Protection degree (E60529): IP67 eight: 500 grams (max.) CPCITE DES ORES TERMIL CPCIT ETREE TESIO LIMETTIO UILIIRE SORTIE il avec embout: min.0,05mm 2 / max.,5mm 2 il souple: min.0,05mm 2 / max. 2,5mm 2 Couple de serrage max.: 0,6m ETREE COURT il avec embout : min.0,05mm 2 / max. 6mm 2 il souple: min.0,05mm 2 / max. mm 2 Couple de serrage max: 1m OLTGE U. SUPPL OUTPUT ith lag: min.0,05mm 2 / max. mm 2 lexible cable: min.0,05mm 2 / max. 2,5mm 2 Tightening torque advised: 0,6m CURRET ith lag: min.0,05mm 2 / max. 6mm 2 lexible cable: min.0,05mm 2 / max. mm 2 Tightening torque advised: 1m T889 09-2015 1 Ed. pag.8/10

SCHEMS DE RCCORDEMET IRIG DIGRMS : 0,5 gg S 1000/0 1n1E Réseau monophasé Single network L 2 11 a b OLTGE CURRET 2 5 8 11 1 3 6 7 9 DIGITL RS 85 U. Rx / Tx GD SUPPL 25 23 2 15 29 33 3 35 20 21 LOD S 1000/1 3-1E Réseau triphasé 3 fils 1 système Three- 3-wires network 1 System 2 5 8 a b a b DIGITL RS 85 OLTGE CURRET Rx / Tx GD 2 5 8 11 1 3 6 7 9 25 23 2 15 29 33 3 35 U. SUPPL 20 21 LOD 31E Réseau triphasé fils 1 système Three- 3-wires network, 1 System S 1000/2 2 5 8 11 a OLTGE CURRET 2 5 8 11 1 3 6 7 DIGITL RS 85 Rx / Tx GD 9 25 23 2 15 29 33 3 35 U. SUPPL 20 21 LOD 3-2E Réseau triphasé 3 fils 2 systèmes Three- 3-wires network, 2 Systems S 1000/3 2 5 8 a b a b DIGITL RS 85 OLTGE CURRET Rx / Tx GD 2 5 8 11 1 3 6 7 9 25 23 2 15 29 33 3 35 U. SUPPL 20 21 LOD T889 09-2015 1 Ed. pag.9/10 3-3E Réseau triphasé 3 fils 3 systèmes Three- 3-wires network, 3 Systems S 1000/ 2 5 8 a b a b DIGITL RS 85 OLTGE CURRET Rx / Tx GD 2 5 8 11 1 3 6 7 9 25 23 2 15 29 33 3 35 LOD U. SUPPL 20 21

TTETIO! DIMESIOS 33E Réseau triphasé fils 3 systèmes Three- -wire network, 3 Systems DIMESIOS 90 71,2 S 1000/5 2 5 8 11 a Les raccordements à la terre indiqués sur les schémas de raccordement (mis en évidence en rouge) sont obligatoires. L alimentation auxiliaire doit être raccordée aux bornes 20 et 21. POSITIO DES ORES TERMIL POSITIO Rogowski 1 3 6 7 OLTGE CURRET 2 5 8 11 1 3 6 7 9 TTETIO! 65,5 DIGITL RS 85 U. Rx / Tx GD SUPPL 25 23 2 15 29 33 3 35 20 21 LOD The earth connections shown in the wiring diagrams (highlighted in red) are compulsory. ux. supply must be connected to terminals 20 and 21. 33 3 35 15 29 9 2 5 8 11 25 23 2 20 21 Modèle Model 80 80 12 12 190 190 www.imesys.fr T889 09-2015 1 Ed. pag.10/10 IMESS se réserve à chaque moment de modifier les caractéristiques sans préavis écrit / IMESS reserves the right to modify the technical characteristics without notice.