OmniSmart 120V 500VA 300W Line-Interactive UPS, Tower, USB port NUMÉRO DE MODÈLE: OMNISMART500 Points principaux 500VA tower 120V line-interactive UPS Corrects brownouts and overvoltages from 75V to 147V 3 UPS battery supported outlets, 3 surge-only outlets USB port, TEL/DSL protection, Front panel status LEDs NEMA 5-15P input plug and 6 NEMA 5-15R outlets Inclut dans l'emballage OMNI SMART 500 UPS System USB and RJ11 Phone Cable Instruction manual with warranty information Présentation générale Tripp Lite's OMNI SMART 500 line interactive UPS system offers voltage regulation, surge suppression and long lasting battery support for personal computers, internetworking equipment and other sensitive electronics. Supports entry level PC systems for up to 30 minutes during power failures so that connected equipment can be shutdown without data loss. Automatic Voltage Regulation (AVR) circuits regulate brownouts as low as 75 volts and overvoltages as high as 147 back to normal 120V levels without consuming battery power. Offers complete desktop power protection in an attractive black upright tower configuration. Includes 3 battery supported outlets for computer, monitor and one vital system peripheral, plus 3 additional surge suppression-only outlets for printers and other system accessories not requiring battery support. USB port enables optional unattended system shutdown without data loss in the case of extended power failure. USB cabling included. PowerAlert software available via download. HID-compliant USB port also enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Built-in dataline protection jacks offer protection of a single dialup phone/dsl line. Built-in audible alarm and 4 front panel LEDs indicate line power status, battery power status, battery low/replace status and overload status. 500VA/300 watt power handling ability supports entry-level PCs, network workstations, point-of-sale equipment, small business phone systems, audio/video equipment and home theater systems. Offers 4 minutes battery runtime with a full load of 500VA/300 watts and 14.6 minutes with a half load of 250VA/150 watts. Supports battery replacement via built-in access panel. Fonctionnalités OMNISMART500 line interactive UPS system offers voltage regulation and battery support, plus complete AC and dialup/dsl line surge suppression Supports entry level PC systems for up to 30 minutes during power failures to enable a safe system shutdown Supports a maximum load of 500VA/300 watts for 4 minutes and a half load of 250VA/150 watts for 14.6 minutes Automatic Voltage Regulation (AVR) circuits correct brownouts as low as 75 volts and overvoltages as high as 147 back to normal 120 volt levels without using battery power Attractive black tower configuration Includes 3 battery supported outlets, plus 3 additional surge suppression-only outlets, 6 foot AC line cord (all NEMA 5-15) USB port enables data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert HID-compliant USB port also enables integration with built-in power management and auto shutdown features of Windows and Mac OS X Supports Tripp Lite's WatchDog Service Monitoring/Rebooting Software (part# WATCHDOGSW) 1 / 5
Dataline suppression jacks protect a single dialup phone/dsl line Audible alarm and 4 front panel LEDs indicate UPS system and line power status 500VA/300 watt power handling ability supports a variety of computer, internetworking, telecom and consumer electronics equipment Supports battery replacement via built-in access panel Compatible with 120V/60Hz applications for USA, Canada, Mexico and more Optional PDUB15 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment Short circuit protection during AC and battery modes Caractéristiques Sortie Puissance en volts-ampères (VA) 500 Capacité en sortie (Watts) 300 Tension(s) de sortie nominale(s) prise(s) en charge Détails de la tension nominale Compatibilité avec fréquences Régulation de la tension de sortie (mode ligne) Régulation de la tension de sortie (mode batterie) 110 V; 115 V; 120 V 115v nominal output in battery mode 60 Hz -18%, +8% +/- 5% Prises de sortie (6) 5-15R Prises de sortie pour onduleur (Protection contre les surtensions uniquement) Options de PDU échangeable à chaud Forme d'onde CA de sortie (mode CA) Forme d'onde de sortie CA (mode Batterie) 3 prises alimentées par la batterie de l'onduleur, 3 prises anti-surtension uniquement PDUB15 (2U / 8 prises 5-15R) Sine wave Signal sinusoïdal à modulation d'impulsions en largeur Entrée Courant d'entrée nominal (charge maximale) Tension(s) d'entrée nominale(s) prise(s) en charge Type de connexion d'entrée de l'onduleur (UPS) Longueur du cordon d'entrée de l'onduleur (pi) Longueur du cordon d'entrée de l'onduleur (m) 12A 120 V CA 5-15P; À angle droit 6 1.8 2 / 5
Service électrique recommandé 15A 120V Longueur du cordon d'entrée (ft.) 6 Longueur du cordon d'alimentation (m) Phase en entrée 1.83 Monophasé Batterie Durée de fonctionnement à pleine charge (min.) Durée de fonctionnement à demi-charge (min.) 4 min. (300w) 14.6 min. (150w) Tension du système CC (V CC) 12 Taux de recharge des batteries (Batteries incluses) Cartouche de batterie de rechange de l'onduleur interne Accès aux batteries Description du remplacement de la batterie Autonomie extensible Less than 3.6 hours from 10% to 90% RBC51 Battery access door Hot-swappable, user replaceable batteries Non Régulation de tension Description de la régulation de tension Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 Correction des surtensions Input voltages between 128 and 147 are reduced by 12% Correction des sous-tensions Input voltages between 93 and 107 are boosted by 14% Correction des fortes sous-tensions Input voltages between 75 and 92 are boosted by 30% Interface Utilisateur, Alarmes et Contrôles Switches Fonctionnement de l'annulation d'alarme Alarme sonore Indicateurs LED 2 Switches control off/on power status and alarm-cancel/self-test operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status Audible alarm indicates power-failure and low-battery conditions 4 LEDs indicate line power, battery power, overload and battery low/replace status Suppression de Bruit / Surtensions Coefficient de suppression Joules CA onduleur Temps de réponse suppression CA onduleur Suppression de la ligne de données de l'onduleur 480 Instantaneous 1 ligne TEL / DSL (1 entrée/1 sortie); Ethernet 10/100Base T 3 / 5
Suppression de bruit CA RFI / IEM Valeur nominale en joules de parasurtension CA Temps de réponse suppression CA Suppression ligne de données Oui 480 Instantaneous 1 line TEL / DSL or 10Base T Ethernet protection Physiques Formats d'installation pris en charge avec accessoires fournis Formats d'installation pris en charge avec accessoires optionnels Facteur de forme primaire Dimensions du module d'alimentation de l'onduleur (hlp, po) Dimensions du module d'alimentation de l'onduleur (hlp, cm) Poids du module d'alimentation de l'onduleur (livres) Poids du module d'alimentation de l'onduleur (kg) Dimensions d'expédition de l'onduleur (hlp / po) Dimensions d'expédition de l'onduleur (hlp / cm) Tour Montage mural (UPSWM - kit de montage en tour) Tour 8.5 x 5.2 x 7 21.59 x 13.21 x 17.78 14 6.35 12 x 10 x 8.2 30.48 x 25.40 x 20.83 Poids d'expédition (livres) 14 Poids d'expédition (kg) 6.4 Matériau du boîtier de l'onduleur PVC Hauteur de l'onduleur principal (mm) 216 Largeur de l'onduleur principal (mm) 132 Profondeur de l'onduleur principal (mm) 178 Hauteur d'expédition (mm) 305 Largeur d'expédition (mm) 254 Profondeur d'expédition (mm) 208 Ecologique Plage de température de fonctionnement Plage de température de stockage Humidité relative +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius 0 to 95%, non-condensing BTU mode CA / Hr. (pleine charge) 53 4 / 5
BTU mode batterie / Hr. (pleine charge) Coefficient de rendement mode CA (Charge 100 %) 324 94% Communication Interface de communication Logiciel PowerAlert Câble de communications Compatibilité WatchDog Compatibilité outils onduleur réseau USB (compatible HID) For local monitoring via the UPS s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert USB cable included Supports Watchdog application, OS and hard-reboot restart options for remote applications NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=tripp Lite Transfert Ligne / Batterie Temps de transfert Transfert basse tension vers alimentation batterie (Consigne) Transfert haute tension vers alimentation batterie (Consigne) 2-4 milliseconds 75 147 Fonctions spéciales Démarrage à froid (démarrage en mode batterie pendant une coupure électrique) Fonctions de haute disponibilité de l'onduleur Fonctions d'économie d'énergie Cold-start operation supported Batteries remplaçables à chaud Efficacité supérieure à 95% - UPS ECOLOGIQUE Certifications Certifications onduleur Testé selon la norme UL1778 (États-Unis); Testé selon les normes CSA (Canada); Testé selon les normes NOM (Mexique); Certifié FCC Part 15 Category B (EMI) Garantie Période de garantie du produit (Mondiale) Assurance équipements connectés (États-Unis, Canada et Porto Rico) Garantie limitée de 2 ans $200,000 Ultimate Lifetime Insurance 2017 Tripp Lite. Tous les droits sont réservés. Tous les noms de produits et de sociétés sont des marques commerciales ou des marques déposées de leurs détenteurs respectifs. Leur utilisation ne comporte aucune affiliation avec ou approbation par eux. Tripp Lite a une politique d'amélioration continue. Les spécifications sont sujettes à modification sans préavis. Tripp Lite utilise les agences primaires et de tiers pour tester ses produits pour conformité aux normes. Voir la liste des agences d essais de Tripp Lite: 5 / 5