OptiSonde. General Eastern Chilled Mirror Hygrometer. GE Sensing. Key Benefits. Applications

Documents pareils
03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Fabricant. 2 terminals

Master4Light. Caractérisation Optique et Electrique des Sources Lumineuses. Equipement 2-en-1 : source de courant et spectrophotomètre

SYSTÈME DE GAINES À SPIRALE ET RACCORDS TOURNANTS

Igloo. Congélateurs Ultra-Froid -45 o C & -86 o C Armoires & Coffres 370 à 830 litres

Z-Axis Compliance Device Compliance en z

Folio Case User s Guide

SERIE TS-770 SYSTEME CONFERENCE

Série M Débitmètres Eletta. Débitmètre à P avec sortie programmable

Vannes à boisseau sphérique Ball valves

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

Le No.1 de l économie d énergie pour patinoires.

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

crm+ capteurs à ultrasons Extrait de notre catalogue en ligne : Mise à jour :

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

Collecteur de distribution de fluide

Notice Technique / Technical Manual

NEW Fin Fan / Air cooled condenser cleaning

epowerswitch 8XM+ Fiche technique

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

MODULES ÉLECTRIQUES. - systèmes électriques DC - onduleurs - convertisseurs - interrupteurs statiques. Notre alimentation Votre confiance

Charge Force Poids. Highly Reliable Systems for Measuring and Monitoring Load, Force and Weight

Paxton. ins Net2 desktop reader USB

Classes of protection IP 65 / IP66 / IP 67 ATEX zone protection Eex "ia" Eex "ed" Eex "em" ATEX II2 G/D

Indicateur universel de procédé format 96 x 48 mm ( 1 /8 DIN)

Package Contents. System Requirements. Before You Begin

Stérilisation / Sterilization

Contents Windows

Transmetteur de pression de haute qualité pour applications industrielles Type S-10

Sonde de surveillance environnementale gamma

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

PVCHECK Rel /11/12

Pressostat électronique avec afficheur Type PSD-30, exécution standard Type PSD-31, à membrane affleurante

Instructions Mozilla Thunderbird Page 1

Contrôle d'accès Access control. Notice technique / Technical Manual

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

ContrôleEnvironnemental

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Contrôleur de débit pour système MicroCoat Manuel utilisateur

Curve. Innover pour simplifier! Mistral signe les fontaines High Tech à hauteur adaptable. Mistral signs the High Tech coolers with adaptable height

CONTEC CO., LTD. Novembre 2010

Système d énergie solaire et de gain énergétique

Information Equipment

OLP-55 Smart Optical Power Meter Un mesureur de puissance optique évolutif de la gamme Smart

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Logitech Speaker System Z553 Setup Guide Guide d installation


Manomètre pour pression différentielle avec contacts électriques Exécution soudée Types DPGS43.1x0, version acier inox

DYNTEST AML (Alarme/Moniteur/Logger) Surveillance du filtre à particules

epowerswitch 4M+ Fiche technique

Laboratory accredited by the French Home Office (official gazette date February 5 th, 1959, modified) Valid five years from August 27 th, 2013

Boîtier de contrôle et de commande avec EV 3/2 voies intégrée

Nouveaux! Analyseurs de COT M9

CHROMATOGRAPHE BTEX GC 5000 BTX

Spécial Catégorie 6 Patch Cords

J TB/TW Limiteur de température, contrôleur de température avec afficheur LCD, montage sur rail oméga 35 mm

Congélateur très basse température ULTRA.GUARD

P7669 MACHINE A VAPEUR MINIATURE P7669R A mouvement alternatif P7669T Turbine

Guide d'installation rapide TFM-560X YO.13

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Comment choisir le bon instrument pour la mesure de l humidité et du point de rosée

WEB page builder and server for SCADA applications usable from a WEB navigator

Face Recognition Performance: Man vs. Machine

Bain à circulation réfrigéré Thermo Scientific VersaCool. Expérimentez les avantages. du fonctionnement sans tête

VIDE DÉBIT MESURE EXCELLENCE EXCELLENCE VIDE DÉBIT MESURE EXCELLENCE DANS LA FABRICATION. EXCELLENCE DANS LES APPLICATIONs

Une production économique! Echangeur d ions TKA

Flottes privatives Une gestion maîtrisée Fleet management The management expert

Guide d installation Deco Drain inc. DD200

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

RAPID Prenez le contrôle sur vos données

Capteur de pression compact dan-hh

Thermomètre portable Type CTH6500

Fonctions intégrées. Nouvelles solutions universelles & système de communication

Recopieur de position Type 4748

ACS-30-EU-PCM2-x-32A Régulation et surveillance du traçage électrique des bâtiments commerciaux et résidentiels pour divers domaines d application

PEINTAMELEC Ingénierie

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

La nouvelle norme dans la mesure de température et d humidité

Système de sécurité de périmètre INTREPID

Système d automation TROVIS 6400 Régulateur compact TROVIS 6493

CCTV. Montage simple et rapide Solutions pour tous types d applications Composants Intégration avec les portiers d interphone

Unité de pompage SKF Maxilube. pour SKF DuoFlex, systèmes de lubrification double ligne

VMT Mod : Ventilation modulée pour le tertiaire

Pompe à chaleur Air-Eau. Confort et économies

Du Thermostat à l ordinateur climatique. Vincent Aubret Hortimax

Garage Door Monitor Model 829LM

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

US US Instruction d'utilisation 03/2010

Instructions d Installation & Maintenance KAPTIV PURGEUR DE CONDENSAT SANS PERTE D AIR 07/09

Application Form/ Formulaire de demande

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

ballons ECS vendus en France, en 2010

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

APPENDICE B SYSTÈME DE PESAGE INTELLIGENT MODÈLE ILC3 ET LM3D VERSION 1.7

Utiliser une WebCam. Micro-ordinateurs, informations, idées, trucs et astuces

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

DTS MOBATime's Distributed Time System

I ntroduction. Coffrets pour la régulation de la température et de l hygrométrie. Caractéristiques et avantages

Nouveautés printemps 2013

Transcription:

Key Benefits Chilled mirror hygrometers are used in standards and metrology labs as well as in industrial applications where precise and repeatable humidity measurement and control are required. The inherent accuracy and long term stability provide many advantages over other types of humidity measurement technologies. Applications Environmental test chambers Engine test cells Clean rooms Air conditioning and heat exchange coil testing Metrology labs Compact and rugged design for easy installation and durability Built-in data logger provides ability to record historical data Sensor conveniently plugs into wall mount chassis for facility monitoring, eliminating the need to run cable Sensors may be connected up to 91 m away via cable for remote monitoring Displays and transmits in a variety of parameters, such as dew point, relative humidity, dry bulb, wet bulb, absolute h umidity, volume ratio, and mass ratio, offering flexibility during operation Digital (RS-232) interface for data integrity Patented PACER cycle automatically cleans mirror to ensure measurement integrity PanaView TM software transfers data from the meter to a PC for additional storage and enables data to be viewed graphically Easy to configure using the front panel for simple operation Humidity measurements are traceable to National Institute of Standards and Traceability (NIST) OptiSonde General Eastern Chilled Mirror Hygrometer General Eastern Instruments has joined other GE high-technology sensing businesses under a new name GE. g

The OptiSonde chilled mirror hygrometer is a National Institute of Standards and Technology (NIST) traceable humidity transfer standard at an exceptional value. The compact rugged analyzer is connected to either a single-or two-stage chilled mirror sensor and PRTD. Chilled mirrors are the humidity sensors of choice when laboratory and process measurements require high precision without long-term drift. An LCD indicates two simultaneous user-configured parameters. OptiSonde provides two user-configured analog (4 to 20 ma) outputs. The display and front panel keys enable quick and easy configuration. The OptiSonde easily records humidity and temperature data from a wide variety of applications. The analyzer is equipped with a data logger capable of recording for 100 days at a sample rate of 1 second and is equipped with an internal real-time clock. The saved data is uploaded to a PC using terminal software as ASCII delimited text, enabling it to be opened by Excel and other spreadsheet programs for data reduction, graphing and statistical analysis. Theory of Operation Chilled mirrors fundamentally measure the dew or frost point temperature by controlling a reflective surface to an equilibrium temperature between dew/frost formation and evaporation and precisely measuring the temperature of the mirror at this point. The cardinal measurements of dew/frost point and dry bulb temperature, along with pressure and molecular weight constants, are used to calculate other humidity parameters, such as relative humidity, wet bulb, ppm v, ppm w, absolute humidity, and water vapor pressure values using psychometric equations. The RTD sensor, which is imbedded in the chilled mirror, never comes in contact with the process or test environment. The wetted parts consist of the platinum or rhodium mirror, Mylar or stainless steel vapor barrier and epoxy sealant. The net result is drift free humidity measurement designed to maintain accuracy specifications for many years. Chilled mirrors require a nominal flow rate across the mirror to achieve the optimal dew/frost formation and response time. The sensor should either be installed in a duct with moving air or be equipped with a sampling pump. The optimum flow rate is 0.5 to 2.5 SCFH (0.25 to 1.2 L/min). GE provides sampling systems to condition the temperature, regulate the pressure and filter process air before reaching the chilled mirror. Our applications engineers would be pleased to discuss your application in detail and provide a recommendation for the system best suited to your needs. Optical balance GE s chilled mirrors consist of a small polished hexagonal rhodium, or platinum mirror attached to a thermoelectric cooling module (TEC). OptiSonde s servo controller applies current to the TEC, which causes the mirror to cool. The mirror is illuminated with a regulated Gallium Arsenide (GaAs) emitter that transmits light in the infrared spectrum. The light reflected by the mirror is received by a photo detector. When water vapor condenses on the mirror as water or frost (ice crystals), the light received by the photodetector is reduced due to scattering. This results in the servo controller reducing the power, causing the mirror to slightly warm. LED regulation Power supply Precission Precision four-wire 4-wire PRTD Light emitting diodes Photo detectors Thermoelectric cooling Cooling module Module Rhodium or or platinum Platinum Mirror mirror OP AMP Gas flow Thermoelectric heat pump control OptiSonde s control system will modulate the amount of current flowing though the TEC to maintain a temperature where the rate of condensation and evaporation of water molecules and the mass of water on the mirror are constant. The resulting temperature of the mirror is then, by definition, equal to the dew or frost point temperature. A precision four-wire platinum RTD imbedded in the mirror measures the temperature. The accuracy of the dew point measurement has been validated to an accuracy of ±0.2 C dew/frost point. Dry bulb temperature is measured with a precise fourwire 100Ω platinum RTD. The dew/frost point and dry bulb RTD resistance signals are conditioned and amplified by OptiSonde s monitor to display and transmit dew/frost point and temperature.

Contamination Control and Self- Cleaning Mirrors For environments where physical contaminants such as dust, oil mist and pollen are present, the use of a sampling system with a filter media is recommended. The filter media must be hydrophobic so as to not absorb or release water vapor into the test stream. Over time the mirror can be etched or pitted by particulates that lead to altering the light scattering characteristics. GE s mirrors are field replaceable. The standard rhodium mirror may be upgraded to platinum for industrial applications. The two stage sensors also utilize stainless steel wetted surfaces. GE developed a patented contamination compensation scheme called PACER (Program Automatic Error Reduction). The PACER cycle may be initiated manually or by programming a timed cycle. The cycle starts by capturing the data (during the PACER cycle a constant reading can be transmitted via the analog outputs) and cooling the mirror well below the dew point such that a thick dew layer forms on the mirror. The mirror is then rapidly heated. During the heating a significant amount of soluble and some non-soluble contamination is flash evaporated. The contamination left on the mirror tends to aggregate in dry islands or spots (much like a glass that comes out of a dishwasher). This process leaves approximately 85% of the mirror clean. The light signal received by the photodetector is compared against a reference LED/photodetector and the two signals are balanced, effectively negating the effect of the residual contamination left on the mirror. Heating Cooling Prevailing dew point Start of of cycle Cycle Mirror heats Heating Mirror to dry heats state Cooling to dry Mirror cools (90 state seconds) (90 and coalesces Mirror cools (30 seconds) and coalesces (30 seconds) Data Data is sampled is and and held (3 minutes) Typical PACER Cycle Optical system automatically Optical system adjusts automatically adjusts for for correct correct reflectance reflectance (5 (5 seconds) End of cycle Cycle Mirror returns to dew point point (60 seconds) The PACER cycle works very well, but eventually manual cleaning may be required. All of GE s chilled mirrors are accessible for manual cleaning. Cleaning is a simple process consisting of wiping the mirror with a cotton swab wetted with cleaning solution or distilled water. Calibration Services Proper calibration is critical to the measurement integrity of your equipment. Comparing and adjusting the output of a device or sensor against a known reference standard ensures accuracy, reliability and repeatability. We provide a single source for initial start-up, programming and verification and for scheduled calibrations. The requirements of your application dictate the frequency of calibration and we will tailor a multiyear contract to your needs. We perform on-site calibrations that keep your equipment in your facility minimizing downtime. This is a good alternative if you have more than one piece of equipment. Mail-in service to our modern calibration facilities provides a more controlled environment and NIST traceability. Before PACER cycle After PACER cycle

OptiSonde Specifications 8.17 in (207.5 mm) 8 in (203.2 mm) 10.48 in (266 mm) Bench Top 8.84 in (224.5 mm) 3.3 in (83.8 mm) 3.7 in (94 mm) 4.49 in (114 mm) 4 X 2.86 in Ø 0.38 in (72.6 mm) 7.8 in (9.7 mm) (198.1 mm) Other Humidity Parameters The range and accuracy of absolute humidity (m H20 /v) and relative humidity (e/e sat ) readings are based on the fundamental dew point and temperature measurements. The range and accuracy of mass (ppm w ) and volume (ppm v ) ratios are calculated based on the fundamental dew point measurement and pressure and gas molecular weight constants. Temperature Accuracy ±0.15 C Repeatability 0.05 C Display Two simultaneous parameters with 0.01 C resolution. Dew Layer Thickness, Control, Alarm and Service indicators Analog Output Two linear simultaneous parameters. 0/4 to 20 ma (isolated) with 250Ω max load Alarm Form C (SPDT) 7 amp, 30 VDC (resistive load) Digital Interface RS-232 Power 100-240 VAC, 50 to 60 Hz, 60 Watts 18-32 VDC (bench top only) Enclosure Material Wall mount: Cast aluminum Bench top: Aluminum body with plastic front bezel Dimensions Wall mount: 26.6 x 20.8 x 11.4 cm (h x w x d) Bench top: 9.4 x 20.3 x 22.4 cm (h x w x d) Weight Wall mount: 2.4 kg Bench mount: 1.4 kg Ingress Protection Rating Wall mount: IP-65 Bench top: IP-20 Front Panel Keys Rubber function keys may be locked out via software Dew Point Range Dependent on sensor used Dew Point Accuracy ± 0.2 C dew/frost point Dew Point Repeatability 0.1 C Wall Mount Cooling Slew Rate 1.5 C/sec Self Cleaning and Balancing Via patented PACER cycle. PACER may be programmed to run on an elapsed time or daily timer Operating Temperature Analyzer: -10 C to 60 C Data Logger Capable of recording eight parameters, time and date for a minimum of 100 days at sample rate of one second. Operating Humidity 0 to 95% RH non-condensing MTBF Five years of continuous operation Certifications CE Approval Electrical I/O Power: AC IEC receptacle for bench top and screw terminal blocks for wall mount. Chilled mirror sensor: keyed connector/cable. Temperature sensor, keyed connector/cable. RS-232: SUB-D-9. Analog Outputs: screw terminals Carrying Case Optional hard shell carrying case with die-cut foam for bench top unit and accessories

1111H Single Stage Chilled Mirror Specifications Operating Temperature -15ºC to 80ºC Operating Pressure 0.8 to 15 bar (-3 to 200 psig) Power Derived from analyzer Ø1.2 in (30 mm) 0.62 in (16 mm) 3.5 in (89 mm) 1 in (25.4 mm) NPT 2.57 in (65 mm) 1.23 in (31 mm) Sensor Body Epoxy-coated aluminum Filter PTFE filter optional (standard on 1111H-GE) Mirror Rhodium-plated copper (solid platinum optional) Vapor Barrier Mylar Dewfrost Dew/frost Point Temperature ( C) ( C) 100 75 50 25 0-25 -50-75 Mirror depression -100-50 -25 0 25 50 75 100 Sensor Sensor Body Body Temperature ( C) ( C) Sensor Wetted Material Epoxy-coated aluminum, rhodium copper, mylar Electrical Connector MS style multipin keyed connector Weight 1.4 kg (1111H) 1.8 kg (1111H-GE) Accessories MB-11: Wall mounting bracket (1111H) PTFE-GE: PTFE filter Platinum mirror O111D: Pressure boss (flow cell) Element Four-wire 1/3 Class A DIN 43760 PRT, 100Ω @ 0 C Dew/Frost Point Accuracy ± 0.2ºC Depression 45ºC at 25ºC, 1 atmosphere for standard air Typical Dew Point Measurement Range -15ºC to 25ºC Td at 25ºC, 1 atmosphere for standard air. (Equivalent to 6-100% RH) 1111 H-GE Sample Flow Rate 0.25 to 1.25 LPM (0.5 to 2.5 SCFH)

D2 Two Stage Chilled Mirror Specifications Element Four-wire 1/3 Class A DIN 43760 PRT, 100Ω @ 0ºC Dew/Frost Point Accuracy ± 0.2ºC Depression 65ºC at 25ºC, 1 atmosphere for standard air Typical Dew Point Measurement Range -35ºC to 25ºC Td at 25ºC, 1 atmosphere for standard air. (Equivalent to 1 to 100 % RH) Sample Flow Rate 0.25 to 1.25 LPM (0.5 to 2.5 SCFH) Ø 0.107 in (4.75 mm) thru 4 places Operating Temperature -25ºC to 85ºC 0.25 in (6.35 mm) compression stainless steel 4.5 in (114 mm) square Operating Pressure 1 to 11 bar (0 to 150 psig) Power Derived from analyzer View Port Equipped with illuminated view port that enables observation of mirror 4 in (102 mm) Sensor Body Cast aluminum with 314 SS flow cell Mirror Rhodium-plated copper (solid platinum optional) Dewfrost Dew/frost Point Temperature ( C) ( C) 100 75 50 25 0-25 -50-75 Mirror depression -100-50 -25 0 25 50 75 100 Sensor Body Temperature ( C) ( C) Vapor Barrier Stainless steel Sensor Wetted Material 302, 314, 316 stainless steel, silicone O-ring, BK-7 glass, rhodium-plated copper or platinum mirror aluminum, rhodium copper, mylar, PTFE Inlet/Outlet 0.25 in (6.35 mm) OD tubing fittings Electrical Connector SUB-D-15 Weight 1.8 kg (4 lb) Accessories Platinum mirror

1211H Two Stage Chilled Mirror Specifications Element Four-wire 1/3 Class A DIN 43760 PRT, 100Ω @ 0 C Dew/Frost Point Accuracy ± 0.2ºC Depression 65ºC at 25ºC, 1 atmosphere for standard air Typical Dew Point Measurement Range -35ºC to 25ºC Td at 25ºC, 1 atmosphere for standard air. (Equivalent to 6 to 100% RH) Sample Flow Rate 0.25 to 1.25 LPM (0.5 to 2.5 SCFH) 5.7 in (144.8 mm) 3.6 in (91.44 mm) g GE Infrastructure 1211H 1/4 in (6.35mm) Compression fitting 3.1 in (78.7 mm) Operating Temperature -25ºC to 100ºC Operating Pressure 1-21 bar (0 to 300 psig) Power Derived from analyzer 5 in (127 mm) Sensor Body Cast aluminum with 314 SS flow cell Dewfrost Dew/frost Point Temperature ( C) ( C) 100 75 50 25 0-25 -50-75 -100 Mirror depression -50-25 0 25 50 75 100 Sensor Body Temperature ( C) Sensor Body Temperature ( C) Mirror Rhodium-plated copper (solid platinum optional) Vapor Barrier Mylar Sensor Wetted Material 302, 314, 316 stainless steel, silicone O-ring, rhodiumplated copper or platinum mirror Inlet/Outlet 0.25 in (6.35 mm) OD tubing fittings Electrical Connector MS style multipin keyed connector Weight 1.8 kg (4 lb) Accessories Platinum mirror Stainless steel vapor barrier

T-100 Four-wire PRTD Temperature Mirror Element Four-wire 1/3 Class A DIN 43760 PRT, 100Ω @ 0 C Accuracy 0.15ºC Range -100ºC to 100ºC Response Time 7 seconds for 25ºC to 70ºC step change in fluid Sensor Body Material Stainless steel Cable PTFE insulation rated to 150ºC, 3 m (10 ft) length, spring strain relief Power Low voltage derived from analyzer Weight 0.9 kg (2 lb) Polytetrafluoroethylene cable 150 C, 10 ft (3 m) standard length Connector 0.25 in (6.35 mm) NPT 7.5 in (190.5 mm) Ø 0.25 in (6.35 mm) Ordering Information Analyzer 1 Benchtop 2 Wall Mount Power 1 100-240 VAC, 50-60 Hz 2 18-32 VDC Chilled Mirror Sensor 0 None 1 1111H Single Stage w/npt Fitting 2 1111H-GE Single Stage w/duct Mt Flange 3 D2 Two Stage 4 1211H Two Stage (High Pressure & Temp) Chilled Mirror Type 1 Rhodium 2 Platinum Chilled Mirror Sensor Vapor Barrier 1 Mylar 2 Stainless Steel Analyzer to Chilled Mirror Sensor Cable 0 No Cable 1111H Fixed to Wall Mount 1 10 Ft Standard 2 25 Ft 3 50 Ft 4 100 Ft 5 200 Ft 6 300 Ft Temperature Sensor 0 T-100 Affixed to Wall Mount 1 T-100 w/10 Ft Cable (Standard) 2 T-100 w/25 Ft Cable 3 T-100 w/50 Ft Cable 4 T-100 w/100 Ft Cable 5 T-100 w/200 Ft Cable 6 T-100 w/300 Ft Cable - - - - - - Notes: 1 1111H sensors are only available with Mylar vapor barriers 2 D2 sensors are only available with stainless steel vapor barriers 3 Analyzer to sensor cable will be dependent on which analyzer (bench or wall) and sensor is ordered 4 All systems are standard dew point accuracy ±0.2 o C Td and temperature ±0.15 o C Ta 5 For 1111H affixed to wall mount, you must select 1111H and wall unit 6 For T-100 affixed to wall mount, you must select the wall analyzer 7 18-32 VDC power supply is only available on bench top analyzer Accessories: PTFE-GE: FILTER for 1111H Sensor Hard shell carrying case for benchtop unit with accessories. Calibration-multilayer Extended warranty g 2007 GE. All rights reserved. 920-423A_E All specifications are subject to change for product improvement without notice. Mylar and Excel are registered trademarks of DuPont and Microsoft Corportation, respectively. GE is a registered trademark of General Electric Co. All products denoted with a or are registered trademarks or trademarks of GE. C2AI - 9 RUE DE CATALOGNE - 69153 DECINES Téléphone: 04 72 15 88 70 - Fax: 04 78 26 41 35 www.c2ai.com www.gesensing.com

La norme de référence de nouvelle génération en matière d humidité Les hygromètres à miroirs refroidis Optica de GE offrent des mesures d humidité, température et pression traçables au National Institute of Standards and Technologies (NIST) _ pour la production raccordée. Maintenant, les données sont accessibles de tout point, à tout moment, à partir d un navigateur Internet ou de votre intranet. Mesures Optica Température Humidité relative (% HR) Point de rosée (Td) Humidité absolue (m/v) Rapport de mélange - masse (m/m) Rapport de mélange - volume (v/v) Réservoir humide (Tw) Enthalpie (h) Pression de vapeur d eau (e) Pression Relais d alarme Sorties analogiques La mesure fondamentale du point de rosée est une mesure principale utilisée comme norme de transfert pour le calibrage d autres instruments et capteurs d humidité. Les miroirs refroidis sont les capteurs préférés lorsque les mesures de process et de laboratoire exigent une haute précision sans dérive à long terme. L Optica pourra être utilisé avec cinq capteurs-miroirs refroidis entièrement interchangeables donnant une plage de mesure de point de rosée entre -112 et 185 F (-80 et 85 C) d une précision de 0,36 F (0,2 C) ou meilleure. Les entrées d un transducteur de pression piézorésistif à base de silicone avec détecteur de température à résistance de 100 S garantissent des mesures de précision, qui permettent de convertir le point de rosée en toute unité métrique, anglaise ou définie par l utilisateur de mesure de l humidité. Optica Optica est un produit General Eastern. General Eastern a rejoint d autres secteurs d activité de détection haute technologie GE sous un nouveau nom _ GE Industrial,. g

Communications Port Ethernet L applet basée sur Java se charge dans les navigateurs du Web. Mémoire d enregistrement des données : 6 Mo Les données enregistrées sont télédéchargées dans le format ASCII Exportation vers des feuilles de calcul Graphe du type «tracé à déroulement continu» en temps réel Affichage VGA couleur matriciel VGA ou 4 x 40 points Logiciels Le logiciel Optica est facile à utiliser. Les utilisateurs sélectionnent l affichage des relevés, un tracé, une échelle de sortie analogique, des communications numériques, des auto-diagnostics, le nettoyage et la consignation des données au moyen de menus déroulants conviviaux. Les valeurs définies peuvent être enregistrées dans la mémoire et chargées à tout moment, soit localement, soit à partir de tout point via le port Ethernet. Calorimètres de serpentin d échangeurs de chaleur et de systèmes de réfrigération Traitement thermique Fabrication de semi-conducteurs Zones de stockage Chambres de validation pharmaceutiques Tests des piles à combustible et des émissions de moteurs Moteurs et turbines d avion Fonctionnalité L Optica mesure simultanément le point de rosée, la température et la pression. L analyseur est équipé de fonctions mathématiques programmables pour produire des unités personnalisées. Les fonctions In, exp +, -, x et / permettent l affichage, l enregistrement et la transmission d unités dérivées aux systèmes d acquisition de données. Le canal d entrée de l analyseur étant une entrée 4 à 20 ma/0 à 5 V c.c. standard, l Optica peut être connecté à tout type de transmetteur de process et être configuré pour afficher des unités. L installation «Plug and Play» s accomplit facilement au moyen de connecteurs standard de sorties d alimentation, de capteur et analogiques. Dans le laboratoire ou l usine Laboratoires d étalonnage Commande de process Salles blanches Caissons d essai environnementaux Surveillance et commande CVC de précision Piles à combustible Principe de fonctionnement des capteurs-miroirs refroidis Les hygromètres à miroirs refroidis de GE s utilisent dans les laboratoires d étalonnage et de métrologie, de même que dans des applications industrielles où la mesure précise et reproductible de l humidité s impose. La précision inhérente et la stabilité à long terme présentent de nombreux avantages sur les autres types de techniques de mesure de l humidité. Les miroirs refroidis mesurent fondamentalement et directement la température du point de rosée en régulant une surface réfléchissante à une température d équilibre entre la formation et l évaporation de la rosée/du givre et en mesurant précisément la température du miroir en ce point.

Les miroirs refroidis de GE sont de petits miroirs hexagonaux en rhodium ou platine poli attachés à un module de refroidissement thermo-électrique (TEC). La servocommande de l analyseur Optica applique le courant au TEC, ce qui entraîne le refroidissement du miroir. Le miroir est éclairé par un émetteur de gaz régulé, qui transmet la lumière dans le spectre infrarouge. La lumière réfléchie par le miroir est reçue par un photodétecteur. Lorsque la vapeur d eau se condense sur le miroir sous forme d eau ou de givre (cristaux de glace), la lumière reçue par le photodétecteur est réduite en raison de la diffusion. En conséquence, la servocommande réduit l alimentation, ce qui entraîne le léger réchauffement du miroir. Le système de commande Optica module la quantité de courant qui circule à travers le TEC pour maintenir une température où le taux de condensation et d évaporation des molécules d eau et de la masse d eau sur le miroir est constant. La température résultante du miroir est ensuite, fondamentalement par définition, égale à la température du point de rosée. Un détecteur de température à résistance (RTD) de précision en platine à 4 fils encastré dans le miroir mesure la température. La précision de la mesure du point de rosée a été validée par rapport à une précision du point de rosée de ±0,36 F (±0,2 C). La précision peut également être améliorée à une précision du point de rosée de ±0,27 F (±0,15 C). La température du réservoir sec est mesurée à l aide d un RTD en platine 100 S à 4 fils précis et la pression est mesurée à l aide d un transducteur de pression en silicium piézorésistif. Les signaux de résistance RTD du réservoir sec et de point de rosée sont conditionnés et amplifiés par le moniteur Optica pour afficher et transmettre le point de rosée et la température. Le capteur de pression transmet un signal de 4 à 20 ma amplifié qui est alimenté par l Optica. Les mesures primordiales de point de rosée, de température du réservoir sec et de pression permettent de calculer d autres paramètres d humidité, comme des valeurs d humidité relative, réservoir humide, rapport de mélange (masse), rapport de mélange (volume), humidité absolue, enthalpie et pression de vapeur d eau à l aide d équations psychométriques. Le capteur RTD est encastré dans le miroir refroidi et ne touche jamais l environnement de process ou d analyse. Les pièces mouillées comprennent le miroir en platine ou rhodium, un pare-vapeur en acier inoxydable ou mylar et un agent d étanchéité en résine époxyde. Le résultat net est une mesure d humidité sans dérive conçu pour maintenir des spécifications de précision pendant de nombreuses années. Les miroirs refroidis exigent un débit nominal à travers le miroir pour produire la formation de rosée/givre et un temps de réponse optimums. Le capteur doit être installé dans une conduite d air en circulation ou être équipé d une pompe d échantillonnage. Le débit optimum est compris entre 0,5 et 5 SCFH (0,25 et 2,5 l/min). GE propose des systèmes d échantillonnage pour conditionner la température, réguler la pression et filtrer l air de process avant qu il n atteigne le miroir refroidi. Nos ingénieurs en applications discuteront en détail de votre application et vous recommanderont le système le mieux adapté à vos besoins. Régulation DEL Alimentation PRTD 4 fils de précision Diodes électroluminescentes Photodétecteurs Équilibre optique Module de refroidissement Miroir en thermoélectrique rhodium ou en platine Nettoyage automatique et commande numérique OP AMP Écoulement de gaz Commande de pompe à chaleur thermo-électrique Pour les environnements où des contaminants physiques comme poussière, brouillard d huile et pollen sont présents, l utilisation d un système d échantillon à filtre est recommandée. Le filtre devra être hydrophobe de sorte à ne pas absorber ni libérer de vapeur d eau dans l écoulement à analyser. Avec le temps, le miroir risque d être rayé ou piqué par des particules, modifiant les caractéristiques de diffusion de la lumière. Les miroirs GE sont remplaçables sur site. Le miroir en rhodium standard pourra être en platine pour les applications industrielles. GE a développé un schéma breveté de compensation de la contamination appelé PACER (Program Automatic Error Reduction). Le cycle PACER pourra être lancé manuellement ou en programmant un cycle minuté. Le cycle démarre en capturant les données (durant le cycle PACER, une valeur constante est transmise) et le refroidissement du miroir bien en dessous du point de rosée à tel point qu une couche épaisse de rosée se forme sur le miroir. Le miroir est ensuite rapidement chauffé. Durant la chauffe, une quantité significative de contamination soluble et une petite quantité de contamination non soluble sont évaporées par évaporation éclair. La contamination qui reste sur le miroir a tendance à s agréger en îlots et taches secs (à la manière d un verre qui sort d un lavevaisselle). Ce processus laisse 85 % environ du miroir propres. Le signal lumineux reçu par le photodétecteur est comparé à une DEL/un photodétecteur de référence et les deux signaux sont «équilibrés», annulant l effet de la contamination résiduelle laissée sur le miroir. Le cycle PACER fonctionne très bien, mais il est possible qu un nettoyage manuel s impose. Tous les miroirs refroidis de GE sont accessibles pour permettre leur nettoyage manuel. Le nettoyage est simple : il vous suffit

de passer dessus un coton-tige humecté de solution nettoyante ou d eau distillée. (L eau distillée est recommandée comme nettoyant final.) GE a développé la commande Digiloop pour surmonter les limites des commandes proportionnelles, intégrales et dérivées (PID) analogiques traditionnelles. La commande de température analogique produit des oscillations, en particulier à des niveaux d humidité élevés ou infimes. Il est difficile d appliquer des constantes d autoréglage ou PID à des boucles de commande analogiques, qui sont suramorties ou sous-amorties. Digiloop utilise l échantillonnage numérique et la réaction positive en effectuant des prélèvements minutés lorsque le point de rosée se situe dans un intervalle proportionnel prédéfini. En enregistrant les oscillations, la commande numérique prédit efficacement l ampleur du changement et ajuste le courant par rapport au module de refroidissement thermo-électrique, en augmentant la température du miroir par incréments de 0,09 F (0,05 C). Ceci se traduit par une commande sensiblement améliorée et une précision supérieure du point de rosée. Refroidissement Point de rosée prévalent Chauffage Température Début de cycle Le miroir refroidit et coalesce (30 secondes) Le miroir chauffe jusqu à l état sec (90 secondes) Le miroir retourne au point de rosée (60 secondes) Les données sont échantillonnées et conservées (3 minutes) Cycle PACER typique Fréquence de balayage Oscillation Le système optique corrige automatiquement la réflectance (5 secondes) Fin de cycle Point de rosée Temps Commande analogique Avant le cycle PACER Cycle PACER Après le cycle PACER Température Fréquence de balayage Incréments de température de 0,05 C Point de rosée Temps Commande Digiloop

Caractéristiques techniques d Optica Modèles VGA couleur avec enregistreur de données et communications Ethernet disponible dans les styles sur établi, bâti ou mur Matriciel 4 x 40 points disponible dans les styles sur établi, bâti ou mur 6,5 po (165 mm) 13,5 po (343 mm) Fixation sur établi 13,5 po (343 mm) Fixation murale 16,5 po (419 mm) Alimentation 95 à 265 V c.a., 50/60 Hz, 200 W E/S électrique Prise secteur style CEI (établi), borne à vis (fixation murale), connecteurs de câble/capteur de température et miroir refroidi multibroche, bornes à vis pour sorties analogiques, DB-9 pour RS232 et 10 base-t pour Ethernet* Paramètres mesurés Point de rosée, température et 4 à 20 ma/0 à 5 V c.c. Paramètres calculés Humidité relative, réservoir humide, rapport de mélange (masse), rapport de mélange (volume), humidité absolue, pression de vapeur d eau et enthalpie en unités anglaises et métriques, de même qu en unités configurées par l utilisateur Entrées 1/3 Classe A DIN 43760, RTD 100 S, point de rosée et température de réservoir sec. 4 à 20 ma c.c. à une charge maximale de 500 S Précision Précision système ±0,36 F (±0,1 C) pour le point de rosée, ±0,27 F (±0,15 C) pour la température, 0,5 % à pleine échelle pour la pression Plage Gouvernée par le capteur Hystérésis Négligeable Sensibilité 0,1 % à pleine échelle A/N 16 bits Mémoire d enregistrement des données 6 Mo* Affichage VGA couleur 1/4 permettant l affichage de six paramètres ou matrice 4 x 40 points permettant l affichage de trois paramètres Température de fonctionnement 32 à 122 F (0 à 50 C) Taux de refroidissement 0,27 F (1,5 C )/s typique au-dessus de 32 F (0 C) Interface numérique Port RS232, port Ethernet* Format de sortie numérique Donnée des texte ASCII, applet Java Ethernet, protection par mot de passe* Adresse TCP/IP Programmable par l utilisateur* Sorties analogiques (2) 4 à 20 ma et 0 à 5 V c.c., configurable par l utilisateur et mise à l échelle possible Sorties analogiques (2) 5 A à 250 V, relais de forme C (SPDT) Boîtier Établi : Type 1 Fixation murale : Type 4 Poids Établi : Fixation murale : 8 lb (3,6 kg) 10 lb (4,5 kg) *Fonction disponible avec les modèles VGA uniquement