Manuel de résolution des problèmes liés aux serveurs HP ProLiant Gen9 Volume II : Messages d'erreur

Documents pareils
Manuel de résolution des problèmes des serveurs HP ProLiant

NOTICE INSTALLATION. ARCHANGE Simplex Office N&B/Couleur KONICA MINOLTA BUSINESS SOLUTIONS FRANCE

HAUTE DISPONIBILITÉ DE MACHINE VIRTUELLE AVEC HYPER-V 2012 R2 PARTIE CONFIGURATION OPENVPN SUR PFSENSE

Contrôle d'accès Access control. Notice technique / Technical Manual

Paxton. ins Net2 desktop reader USB

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

Guide pour l Installation des Disques Durs SATA et Configuration RAID

Package Contents. System Requirements. Before You Begin

Instructions Mozilla Thunderbird Page 1

DELL E6500 : Remplacement du disque dur d origine par un disque dur chiffrant

SERVEUR DÉDIÉ DOCUMENTATION

Principe de TrueCrypt. Créer un volume pour TrueCrypt

Spécifications détaillées

Choix d'un serveur. Choix 1 : HP ProLiant DL380 G7 Base - Xeon E GHz

Contrôle d accès Access control MOD-TCPIP-AI. Notice technique / Technical Manual

Guide d'installation rapide TFM-560X YO.13

Manuel de l utilitaire Computer Setup (F10) HP Compaq Business Desktops Modèles d220 et d230

Manuel de l utilisateur de HP Array Configuration Utility

Nouveautés printemps 2013

Contents Windows

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

SERVEUR CALLEO APPLICATION R269M

WEB page builder and server for SCADA applications usable from a WEB navigator

Quick Installation Guide TEW-P21G

Notice Technique / Technical Manual

VTP. LAN Switching and Wireless Chapitre 4

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

HSCS 6.4 : mieux appréhender la gestion du stockage en environnement VMware et service de fichiers HNAS Laurent Bartoletti Product Marketing Manager

SERVEUR LYNX CALLEO DATACENTER 2460

NOTICE INSTALLATION. ARCHANGE WebDAV Office N&B/Couleur KONICA MINOLTA BUSINESS SOLUTIONS FRANCE

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

IMS INTERNET /Paramétrage de l offre / Gateway Cisco IMS INTERNET. Paramétrage de l offre Gateway CISCO. Référence Edition Date de Diffusion Page

Tout le monde parle du Cloud Computing, Mais qui offre une solution complète? Copyright IBM Corporation, 2009 All Rights Reserved

Garage Door Monitor Model 829LM

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

How to Login to Career Page

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Serveur Lynx CALLEO Application 2240 Fiches Technique

Gestion et impression

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Cours 13. RAID et SAN. 2004, Marc-André Léger

Présentation du SC101

CommandCenter Secure Gateway

file://\\tsclient\unix\msa.html

Serveur Lynx CALLEO Application 2240S Fiches Technique

Spécifications détaillées

Sun Blade G2 RAID 0/1 Expansion Module Installation Guide

Oracle FS Data Protection Manager. Release Notes. Part Number E Oracle FS Data Protection Manager release 3.5.

Gamme Serveurs HP ProLiant Rack

Fiche produit Fujitsu Serveur NAS CELVIN Q600 STOCKAGE RESEAU

DOCUMENTATION - FRANCAIS... 2

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Municipalité de La Nation The Nation Municipality

Configuration de l'ordinateur Manuel de l'utilisateur

GAME CONTENTS CONTENU DU JEU OBJECT OF THE GAME BUT DU JEU

POLICY: FREE MILK PROGRAM CODE: CS-4

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

Editing and managing Systems engineering processes at Snecma

DOCUMENTATION - FRANCAIS... 2

VMware ESX : Installation. Hervé Chaudret RSI - Délégation Centre Poitou-Charentes

Frequently Asked Questions

Stockage Réseau. Le stockage s'échappe du système pour devenir une fonction réseau

Table des matières. 1. Installation de VMware ESXI Pré-requis Installation... 3

Surveillance de Scripts LUA et de réception d EVENT. avec LoriotPro Extended & Broadcast Edition

StruxureWare Power Monitoring v7.0. La nouvelle génération en matière de logiciel de gestion complète d énergie

Dexia Guide d installation de NetWorker Server 25 juin Legato Systems, Inc.

Extended Communication Server release 4: Service pack 2

Le Cloud Computing est-il l ennemi de la Sécurité?

Warning: Failure to follow these warnings could result in property damage, or personal injury.

ANF Datacentre. Jonathan Schaeffer Monitoring Environnemental Ad-Hoc. J. Schaeffer. Intro. Dans mon rack.

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

Utiliser une WebCam. Micro-ordinateurs, informations, idées, trucs et astuces

1 Configuration des Fichiers Hosts, Hostname, Resolv.conf

TP LINUX : LINUX-SAMBA SERVEUR DE FICHIERS POUR UTILISATEURS WINDOWS

Manuel de l'utilisateur du module HP BladeSystem Onboard Administrator

ADMINISTRATION EXADATA

APPENDIX 6 BONUS RING FORMAT

SAN AoE (ATA over Ethernet)

Fabricant. 2 terminals

Guide de récupération de Windows Server 2003 R2 pour serveurs Sun x64

SunATM 4.0 Release Notes

PayShield 9000 Présentation générale

SNMP for cloud Jean Parpaillon. SNMP4cloud - 1

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

Agenda. Exemple : données et back à Eurecom SANs and NAS. Les bases: SANs. Back-up Partage de fichier. Disques et Raid SCSI et FCP

INDIVIDUALS AND LEGAL ENTITIES: If the dividends have not been paid yet, you may be eligible for the simplified procedure.

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Quick Installation Guide TBW-106UB H/W: V1

Quick Setup Guide Guide de configuration rapide. Tablet Device SGPT12 Series Tablette électronique Série SGPT12

USB 598. Quick Start Guide (Windows) Guide de démarrage rapide (Windows) USB Modem. Modem USB.

Sécurité des systèmes d exploitation

NIMBUS TRAINING. Administration de Citrix NetScaler 10. Déscription : Objectifs. Publics. Durée. Pré-requis. Programme de cette formation

VMotion ne peut fonctionner qu avec une architecture de stockage centralisé de type SAN FC, iscsi ou NAS.

Transcription:

Manuel de résolution des problèmes liés aux serveurs HP ProLiant Gen9 Volume II : Messages d'erreur Résumé Ce manuel contient une liste des messages d'erreur associés aux serveurs HP ProLiant, à HP Integrated Lights-Out, au stockage HP Smart Array, à HP Onboard Administrator, à HP Virtual Connect, à ROM et à Configuration Replication Utility. Ce manuel est destiné au personnel qui installe, administre et répare les serveurs et lames de serveur. HP suppose que vous êtes qualifié en réparation de matériel informatique et que vous êtes averti des risques inhérents aux produits capables de générer des niveaux d'énergie élevés.

Copyright 2014, 2015 Hewlett-Packard Development Company, L.P. Les informations contenues dans ce document pourront faire l'objet de modifications sans préavis. Les garanties relatives aux produits et services HP sont exclusivement définies dans les déclarations de garantie limitée qui accompagnent ces produits et services. Aucune information de ce document ne peut être interprétée comme constituant une garantie supplémentaire. HP ne pourra être tenu responsable des éventuelles erreurs ou omissions de nature technique ou rédactionnelle qui pourraient subsister dans le présent document. Java est une marque déposée d'oracle et/ou de ses filiales. Linux est une marque déposée de Linus Torvalds aux États-Unis et dans d'autres pays. Microsoft, Windows et Windows Server sont des marques commerciales ou des marques déposées de Microsoft Corporation aux États-Unis et/ou dans d'autres pays. SD et microsd sont des marques commerciales ou marques déposées de SD-3C aux États-Unis, dans d'autres pays ou les deux. UNIX est une marque déposée de The Open Group. Référence : 795673-052 Septembre 2015 Édition : 2

Sommaire 1 Introduction... 1 Présentation... 1 Résolution des problèmes de ressources... 1 2 Erreurs sur les serveurs HP ProLiant... 2 Messages d'erreur de diagnostic de module RAID... 2 Messages d'erreur de l'utilitaire de diagnostic HP Smart Storage Administrator... 2 Array status: The array has failed... 2 Array status: The array currently has a drive erase operation queued, running, stopped or completed on a logical or physical drive... 2 Array Status: The array has a spare drive assigned which is smaller than the smallest data drive in the array... 2 Cache module: The batteries were hot-removed... 2 Cache module: The cache is disabled because the batteries are low on the redundant controller... 2 Cache module: The cache for this controller is temporarily disabled since a snapshot is in progress...... 2 Cache module: The cache is disabled because the batteries are low... 2 Cache module: This controller has been set up to be a part of a redundant pair of controllers...... 3 Cache module: The cache is disabled because the restore operation from flash memory failed... 3 Cache module: The cache is disabled because the charge on the flashmemory capacitor is too low... 3 Cache module: The cache is disabled because a capacitor has failed to charge to an acceptable level... 3 Cache module: The cache is disabled because the backup operation to flash memory failed... 3 Cache module: The cache is disabled because there are no capacitors attached to the cache module... 3 Cache module: The cache is disabled because a flash memory or capacitor hardware failure has been detected... 3 Cache module: This controller's firmware is not backward compatible with the cache module revision... 3 Controller State: The array controller contains a volume that was created with a different version of controller firmware... 3 Controller State: The array controller contains more logical drives than are supported in the current configuration... 4 FRWW iii

Controller State: The array controller contains one or more logical drives with a RAID level that is not supported in the current configuration... 4 Controller State: The array controller contains redundant connections to one or more physical drives that are not supported in the current configuration... 4 Controller State: The array controller is connected to an expander card or an external enclosure... 4 Controller State: The array controller is operating without a memory board... 4 Controller State: The array controller is operating without a memory board and has a bad volume position... 5 Controller State: The array controller is operating without a memory board and contains more logical drives than are supported in the current configuration... 5 Controller State: The array controller is operating without a memory board and has an invalid physical drive connection... 5 Controller State: The array controller has a configuration that requires more physical drives than are currently supported... 5 Controller State: The array controller has an unknown disabled configuration status message... 5 Controller State: The array controller has an unsupported configuration... 5 Controller State: The controller cannot be configured. CACHE STATUS PROBLEM DETECTED...... 6 Controller State: A logical drive is configured with a newer version of the Array Configuration tools than is currently running... 6 Controller State: The HBA does not have an access ID...... 6 Drive Offline due to Erase Operation: The logical drive is offline from having an erase in progress... 6 Drive Offline due to Erase Operation: The physical drive is currently queued for erase... 6 Drive Offline due to Erase Operation: The physical drive is offline and currently being erased... 6 Drive Offline due to Erase Operation: The physical drive is offline and the erase process has been failed...... 6 Drive Offline due to Erase Operation: The physical drive is offline and the erase process has completed...... 7 Drive Offline due to Erase Operation: The physical drive is offline from having an erase in progress... 7 Failed Array Controller: code:<lockup Code> : Restart the server and run a diagnostic report... 7 Logical drive state: A logical drive is configured with a newer version of Storage/Config Mod than is currently running... 7 Logical drive state: Background parity initialization is currently queued...... 7 iv FRWW

Logical drive state: The current array controller is performing capacity expansion...... 7 Logical drive state: The logical drive is disabled from a SCSI ID conflict... 7 Logical drive state: The logical drive is not configured... 7 Logical drive state: The logical drive is not yet available... 7 Logical drive state: The logical drive is offline from being ejected... 8 Logical drive state: The logical drive is queued for erase... 8 Logical drive state: The logical drive is queued for expansion... 8 Logical drive state: The logical drive is queued for rebuilding... 8 Logical drive state: This logical drive has a high physical drive count...... 8 NVRAM Error: Board ID could not be read...... 8 NVRAM Error: Bootstrap NVRAM image failed checksum test...... 8 NVRAM Error: Bootstrap NVRAM image failed checksum test...... 8 Physical Drive State: The data on the physical drive is being rebuilt... 8 Physical Drive State: Predictive failure. This physical drive is predicted to fail soon... 8 Physical Drive State: This drive is not supported for configuration...... 9 Physical Drive State: SATA drives are not supported for configuration and should be disconnected from this controller... 9 Physical Drive State: Single-ported drives are not supported for configuration and should be disconnected from this controller... 9 Physical Drive State: This drive contains unsupported configuration data...... 9 Physical Drive State: This drive is not supported for configuration by this version of controller firmware... 9 Physical Drive State: This drive is smaller in size than the drive it is replacing...... 9 Physical Drive State: This drive is unrecognizable...... 9 Physical Drive State: This physical drive is part of a logical drive that is not supported by the current configuration...... 9 Redundancy State: This controller has been setup to be part of a redundant pair of controllers...... 10 Redundancy State: This controller has been setup to be part of a redundant pair of controllers...... 10 Redundant Path Failure: Multi-domain path failure... 10 Redundant Path Failure: The logical drive is degraded due to the loss of a redundant path... 10 Redundant Path Failure: The physical drive is degraded due to the loss of a redundant path... 10 Redundant Path Failure: Warning: Redundant I/0 modules of this storage box...... 10 Smart SSD State: SSD has less than 2% of usage remaining before wearout... 10 FRWW v

Smart SSD State: SSD has less than 2% of usage remaining before wearout... 10 Smart SSD State: SSD has less than 5% of usage remaining before wearout... 10 Smart SSD State: SSD has less than 5% of usage remaining before wearout... 11 Smart SSD State: SSD has less than an estimated 56 days before it reaches the maximum usage limit for writes (wearout)...... 11 Smart SSD State: SSD has reached the maximum rated usage limit for writes (wearout) and should be replaced immediately... 11 Smart SSD State: The SmartSSD Wear Gauge log is full... 11 Storage Enclosure: The enclosure is reporting a critical temperature status condition...... 11 Storage Enclosure: One or more fans have failed... 11 Storage Enclosure: Warning: The enclosure is reporting a high temperature status... 11 Storage Enclosure: Warning: One or more redundant power supplies in this enclosure has failed or is not plugged in correctly... 11 POST, messages d'erreur... 12 Introduction aux messages d'erreur POST... 12 Série 100... 12 102-System board error... 12 104-ASR Timer Failure... 12 162-Systems Options Not Set... 12 163-Time and date not set... 12 Série 200... 12 207-DIMM configuration errors... 12 209-DIMM Configuration Error- Installed DIMM configuration does NOT support configured AMP Mode... 13 210-Processor X: Quick Path Interconnect (QPI) Link Degradation... 13 212-CPU failed... 13 224-Power fault detected FlexLOM X... 13 225-Power fault detected Mezzanine X... 14 226-Power fault detected Embedded storage controller... 14 228- DIMM Configuration Error - Processor X, Channel Y... 14 229-DIMM Configuration Error Processor X, DIMM Y... 14 230-DIMM Configuration Error Processor X, Channel Y... 14 231-DIMM Configuration Error... 15 232-Memory initialization error Processor A, DIMM B failed... 15 233-Trusted Execution Technology (TXT) Failure Secrets in Memory detected and BIOS may be compromised... 15 234-DIMM Initialization Error Memory cannot be initialized... 15 vi FRWW

235-DIMM Configuration Error... 15 236-DIMM Configuration Error... 16 237-DIMM Configuration Error Processor X, DIMM Y... 16 238-DIMM Configuration Error Processor X, DIMM Y... 16 239-DIMM Configuration Error... 16 240-Unsupported Expansion Riser Board Detected One or more of the installed expansion riser boards is not supported by this server... 16 241-Expansion Riser Board Detected in Incorrect Slot An expansion riser board is installed in a riser slot in which it is not supported... 17 242-Unsupported Processor Configuration Detected - System does not support booting with three processors installed... 17 243-Unsupported Option Card configuration. The option card installed in Slot X is not supported in that slot with the current server configuration... 17 244 IMPORTANT: PCIe Slot X only supports 8 functions for a SR-IOV capable Expansion Card... 17 245-Processor Power-on Issue: Processor X did not power up... 17 246 IMPORTANT: The system has exceeded the amount of available Option ROM space... 18 248 Unsupported Option Card configuration. The option card installed in Slot X is only supported in Slot Y... 18 249-Unsupported Option Card configuration. The option card installed in Slot X is not supported unless Slot Y is unpopulated... 18 250-Unsupported Processor Configuration Detected... 18 251-IMPORTANT: Switches SW1 and SW3 are ON... 18 252-Unsupported Processor Configuration Detected... 18 253-IMPORTANT: The PCI-e Device installed in Slot X has no corresponding processor installed and will not function... 18 254-IMPORTANT: A FlexCompute license is installed that cannot be utilized by installed processors(s)... 19 256-IMPORTANT: A PCI-e Riser Card is installed that requires 2 processors to function... 19 257-Memory Initialization Error - Memory on Processor X failed to initialize... 19 258-Unsupported Processor Configuration Detected... 19 259-Unsupported Processor Configuration Detected... 19 260-Configuration Error - Online Spare (OLS) Mode and Combined Channel (CC) Mode are both Enabled... 19 261-Server Platform Services Firmware requires update... 19 262- Redundant ROM Error: The Backup System ROM is invalid... 20 263-Redundant ROM Error: The Primary System ROM is invalid... 20 264-Fatal System ROM Error: The System ROM is not programmed properly... 20 265- Fatal System ROM Error: The programming of the System ROM cannot be verified... 20 FRWW vii

266- Non-Volatile Memory Corruption Detected... 20 267- IMPORTANT: Default configuration settings have been restored at the request of the user... 20 268- ilo FW Not Responding Unable to communicate with ilo FW... 20 269- IMPORTANT: Default configuration settings have been restored per user request... 20 270- ilo FW Communication Issue Unable to communicate with ilo FW... 20 271- Processor X, DIMM Y could not be authenticated as genuine HP SmartMemory... 21 273-Unsupported Option Card Configuration. The option card installed in Slot Y is not supported in Slot 3 or Slot 4... 21 275-Unsupported Processor Detected - Processor stepping not supported... 21 276-Option Card Configuration Error... 21 277- Secure Boot Authentication Failure... 21 278- Secure Boot Authentication Failure... 21 279-Cable Error - An internal cable routed to the LED Board is not plugged in or plugged in incorrectly... 21 280-Cable Error - An internal cable routed to the SUV connector is not plugged in or plugged in correctly... 22 281-IMPORTANT: SW12 is ON indicating physical presence... 22 282-Invalid Server Serial Number and Product ID... 22 283-Memory Address/Command Parity Error Detected Processor X, Channel Y... 22 284-DIMM Failure Uncorrectable Memory Error Processor X, DIMM Y... 22 284-DIMM Failure Uncorrectable Memory Error Memory Board X, DIMM Y... 22 285-DIMM Failure Uncorrectable Memory Error Processor X, DIMM Y or Processor X, DIMM Z... 22 285-DIMM Failure Uncorrectable Memory Error Memory Board X, DIMM Y or Processor X, DIMM Z... 22 286- IMPORTANT: The removal of a storage device has been detected... 23 287- IMPORTANT: The removal of a network device has been detected... 23 288- IMPORTANT: A new storage device has been detected and has been added to the end of the Boot Controller Order... 23 289-IMPORTANT: A new network or storage device has been detected... 23 290- IMPORTANT: The Boot Mode for the system has been changed to Legacy Boot Mode... 23 291- IMPORTANT: The Standard Boot Order (IPL) has been detected as corrupted and has been restored to default values... 23 292- Invalid HP Software RAID Configuration... 23 293- A critical error occurred resulting in a reboot of the system... 23 294-Memory Board X Training Failure... 23 295-DIMM Failure Uncorrectable Memory Error Processor X, DIMM Y... 24 viii FRWW

295-DIMM Failure Uncorrectable Memory Error Memory Board X, DIMM Y... 24 296-DIMM Configuration Error - Processor X, DIMM Y - Non-production DIMM detected... 24 297-IMPORTANT: The ilo Security switch is set to the ON position... 24 298- IMPORTANT: The Boot Mode has been changed to Legacy Boot Mode for this boot only... 24 299- IMPORTANT: The Boot Mode has been changed to UEFI Boot Mode for this boot only... 24 Série 300... 24 300- IMPORTANT: Unable to log an entry to the Integrated Management Log (IML)... 24 301-Keyboard Error... 24 301-Keyboard Error or Test Fixture Installed... 25 303-Keyboard controller error... 25 304-Keyboard or System Unit Error... 25 305- Redundant ROM Error: Both the Primary and Backup System ROMs are invalid... 25 306- Redundant ROM Error: ilo FW did not set the Primary System ROM... 26 307-Fan Failure Detected Fan X Failed... 26 308-Required Fan NOT Installed Fan X Missing... 26 309-Insufficient Fan Solution... 26 310- IMPORTANT: Fan Solution Not Redundant... 26 311-HP Smart Storage Battery Configuration Error The system has exceeded the installed battery capacity... 26 312-HP Smart Storage Battery X Failure Communication with the battery failed and its output may not be enabled... 26 313-HP Smart Storage Battery X Failure Battery Shutdown Event Code: XXXX... 26 314- A critical error occurred prior to this system boot... 27 315-An uncorrectable memory error was detected prior to this system boot... 27 316-Chassis Firmware Error The Chassis Firmware is in Recovery Mode... 27 317- Chassis Firmware Error - Unable to communicate with the Chassis Firmware... 27 318-Trusted Platform Module (TPM) Self-Test Error... 27 319-An unexpected shutdown was detected prior to this boot... 27 320-IMPORTANT: Enclosure Power Event detected. Boot delayed until condition resolved... 27 321-HP Dual microsd Device Unsupported Configuration A microsd card is not installed in Slot X... 27 322-HP Dual microsd Device Unsupported Configuration No microsd cards are installed... 27 323-HP Dual microsd Device Error The microsd card in Slot X has failed.. 27 FRWW ix

324-HP Dual microsd Device Error Both microsd cards have failed... 27 325-HP Dual microsd Device Error microsd cards have conflicting metadata. Configuration required... 28 326-HP Dual microsd Device Error The microsd card in Slot X has failed. A microsd card is not installed in Slot Y... 28 Série 400... 28 40X-Parallel Port X Address Assignment Conflict... 28 404-Parallel Port Address Conflict Detected... 28 Série 1500... 28 1500-iLO 4 configuration is temporarily unavailable... 28 1501-iLO 4 Security Override Switch is set. ilo 4 security is DISABLED!... 28 1502-iLO 4 is disabled. Use the Security Override Switch and ilo 4 F8 ROM-Based Setup Utility to enable ilo functionality... 29 1503-iLO 4 ROM-based Setup Utility is disabled... 29 1503-ROM-based Setup Utility is disabled... 29 Série 1600... 29 1609-Battery Failure message. This is detected by checking the RTC Lost Power bit in CMOS (Byte 0Dh - Bit 7)... 29 1610-Temperature violation detected. Waiting 5 Minutes for System to Cool... 29 1611-CPU Zone Fan Assembly Failure Detected. Either...... 30 1611-CPU Zone Fan Assembly Failure Detected. Single fan...... 30 1611-Fan failure detected... 30 1611-Fan X Failure Detected (Fan Zone CPU)... 30 1611-Fan X Failure Detected (Fan Zone I/O)... 31 1611-Fan X Not Present (Fan Zone CPU)... 31 1611-Fan x Not Present (Fan Zone I/O)... 31 1611-Power Supply Zone Fan Assembly Failure Detected...... 31 1611-Power Supply Zone Fan Assembly Failure Detected...... 32 1611-Primary Fan Failure (Fan Zone System)... 32 1611-Redundant Fan Failure (Fan Zone System)... 32 1612-Primary Power Supply Failure... 32 1613-Low System Battery warning... 32 1614-Redundant Fan Failure... 32 1615-Power Supply Configuration Error... 33 1615-Power Supply Configuration Error... 33 1615-Power Supply Failure, Power Supply Unplugged, or Power Supply Fan Failure in Bay X... 33 1616-Power Supply Configuration Failure... 33 1623-Power Supply Failure Power Supply X is failed... 33 1624- Power Supply Unplugged Power Supply X is unplugged... 33 x FRWW

1625-Unsupported Power Supply Configuration Unsupported Power Supply Mismatch... 33 1626-Unsupported Power Supply Configuration Unsupported Power Supply detected... 33 1627-Power Supply Configuration Insufficient... 34 1628-IMPORTANT: The system contains multiple types of power supplies... 34 Série 1700... 34 1700-Slot # Drive Array Please replace battery...... 34 1701-Slot # Drive Array Please install battery...... 34 1702-SCSI Cable Error Detected... 34 1703-Slot X Drive Array controller - Memory Self-Test Error. Access to all storage has been disabled... 34 1704-Slot X System Halted. Unsupported Virtual Mode Disk Operation... 35 1705-Slot # Drive Array Please replace Cache Module Super-Cap...... 35 1706-The Extended BIOS Data Area in Server Memory has been Overwritten...... 35 1707-Slot X Drive Array Controller - Bootstrap NVRAM checksum invalid... 35 1708 - Slot X Drive Array Controller - Bootstrap NVRAM restored from backup. System restart required... 35 1709-One or more attached hard drives could not be authenticated as a genuine HP hard drive... 35 1710-Slot X Drive Array Non-Array Controller Drives Detected Warning: possible data loss may occur... 36 1711-Slot # Drive Array Stripe size too large for RAID 5/6 logical drive(s)... 36 1712-Slot X Drive Array RAID 5 volume(s) present with 56 drives or more, but cache size <= 32MB... 36 1713-Slot X Array Controller Redundant ROM Reprogramming Failure... 36 1714-Slot X Array Controller Redundant ROM Checksum Error... 36 1715-Slot # Drive Array Controller Memory Error(s) Occurred... 37 1716-Slot # Drive Array Unrecoverable Media Errors Detected on Drives... 37 1717-Slot X Drive Array Disk Drive(s) Reporting OVERHEATED Condition: Port X Box Y Bay(s) Z... 37 1718-Slot X Drive Array Device discovery found more devices attached to this controller than firmware currently supports...... 37 1719 A controller failure event occurred prior to this power-up. (Previous lock up code = 0x####)... 38 1720-Slot X Drive Array S.M.A.R.T. Hard Drive(s) Detect imminent failure: Port X Box Y Bay(s) Z... 38 1721-Slot # Drive Array Drive Parameter Tracking Predicts Imminent Failure... 38 1722-Slot x Drive Array Redundant Controller Pair Not Operating Redundantly... 38 1723-Slot X Drive Array To improve signal integrity... 39 FRWW xi

1724-Slot # Drive Array Physical Drive Position Change(s) Detected... 39 1725-Slot # Drive Array Incompatibility between CPLD and BBWC Detected Caching is disabled until CPLD has been updated... 39 1726-Slot X Drive Array - Cache Memory Size or Battery Presence Has Changed... 39 1727-Slot X Drive Array - New (or Previously Failed) Logical Drive(s) Attachment Detected... 40 1728-Slot # Drive Array Abnormal Shut-Down Detected with Write Cache Enabled... 40 1729-Slot # Drive Array Disk Performance Optimization Scan in Progress...... 40 1730-Fixed Disk 0 Does Not Support DMA Mode... 40 1731-Fixed Disk 1 Does Not Support DMA Mode... 40 1732-Slot # Drive Array Cache Module Battery Pack Missing...... 40 1733-Slot # Drive Array Storage Enclosure Firmware Upgrade Problem Detected...... 40 1734-Slot # Drive Array Disk Drive(s) Responding to Incorrect SCSI ID... 41 1735-Slot # Drive Array Unsupported Redundant Cabling Configuration Detected...... 41 1736-HP Trusted Platform Module Error... 41 1737-Slot X Drive Array Redundant Cabling Configuration has excess Device Paths... 42 1738-Slot # Drive Array Storage Enclosure Redundant Cabling Problem Detected... 42 1739-Slot # Drive Array Redundant Cabling is not as recommended... 42 1740-Fixed Disk 0 failed set Block Mode... 42 1741-Fixed Disk 1 failed set Block Mode... 43 1742-Slot X Drive Array - Previously Ejected Drive(s) Detected...... 43 1743-Slot # Drive Array Logical Drive Erase Operation in Progress...... 43 1743-Slot # Drive Array Logical Drive Erase Operation(s) are Queued...... 43 1744-Slot X Drive Array Drive Erase Operation In Progress (or Queued)..... 43 1745-Slot X Drive Array - Drive Erase Operation Completed...... 44 1746-Slot X Drive Array Unsupported Storage Connection Detected...... 44 1747-Slot # Drive Array Unsupported Array Configuration Detected...... 44 1748-Slot # Drive Array Unsupported Cache Module Battery Attached...... 45 1749-Slot X Drive Array Cache Module Flash Memory being erased... 45 1750-Fixed Disk 0 failed ID command... 45 1751-Fixed Disk 1 failed ID command... 45 1752- Slot X Drive Array...... 45 1753-Slot X Drive Array Array Controller Maximum Operating Temperature Exceeded During Previous Power Up... 45 1754-Slot X Drive Array One or more RAID levels are configured...... 45 xii FRWW

1755-Slot Z Drive Array ADG Enabler Module appears to be defective. Please replace ADG Enabler Module... 46 1756-Slot X Drive Array Redundant controllers are not the same model... 46 1762-Slot X Drive Array Controller Firmware Upgrade Needed... 46 1763-Slot X Drive Array Cache module is detached; please reattach... 46 1764-Slot X Drive Array Capacity Expansion Process is Temporarily Disabled...... 47 1766-Slot X Drive Array... 47 1768-Slot X Drive Array Resuming logical drive expansion process... 47 1769- Slot X Drive Array Drive(s) Disabled due to Failure During Expansion... 47 1770-Slot X Drive Array Disk Drive Firmware Update Recommended... 48 1774-Slot X Drive Array Obsolete data found in Cache Module...... 48 1775-Slot X Drive Array Storage Enclosure Cabling Problem Detected: SAS Port Y: OUT port of this box is attached to OUT port of previous box...... 48 1776-Slot X Drive Array Shared SAS Port Connection Conflict Detected - Ports 1I, 1E: Storage connections detected on both shared internal and external ports... 48 1777-Slot X Drive Array Storage Enclosure Problem Detected...... 48 1778-Slot X Drive Array resuming Automatic Data Recovery (Rebuild) process... 49 1779- Slot X Drive Array Replacement drive(s) detected OR previously failed drive(s) now appear to be operational... 49 1779- Slot X Drive Array Replacement drive(s) detected OR previously failed drive(s) now appear to be operational... 50 1783-Slot X Drive Array Controller Failure...... 50 1784-Slot X Drive Array Logical Drive Failure... 50 1784-Slot X Drive Array Drive Failure...... 51 1785-Slot X Drive Array Not Configured...... 51 1786-Slot X Drive Array Recovery Needed...... 52 1787-Slot X Drive Array Operating in Interim Recovery (Degraded) Mode...... 52 1788-SlotX Drive Array Reports Incorrect Drive Replacement...... 52 1789-Slot X Drive Array Disk Drive(s) Not Responding...... 53 1792-Slot X Drive Array Valid Data Found in Write-Back Cache... 53 1793-Slot X Drive Array Data in Write-Back Cache has been lost... 54 1794 Slot X Drive Array Cache Module Battery Pack is Charging... 54 1795-Slot X Drive Array Write-Back Cache Configuration Error... 54 1796-Slot X Drive Array Cache Module is Not Responding... 54 1797-Slot X Drive Array Write-Back Cache Backup Previously Failed... 55 1797-Slot X Drive Array Write-Back Cache Restore Previously Failed... 55 1797-Slot X Drive Array Write-Back Cache Read Error Occurred... 55 1798-Slot X Drive Array Cache Module Self-Test Error Occurred... 56 FRWW xiii

1799-Slot X Drive Array Drive(s) Disabled due to Write-Back Cache Data Loss... 56 Série 1800... 56 1802-Slot X Drive Array Dual domain configured or detected but not supported by this configuration... 56 1803-Slot X Drive Array Cache Module is not installed... 56 1804-Slot X Drive Array Cache Module critical error... 56 1806-Slot X Drive Array Cache Module flash memory is not installed... 57 1807-Slot X Drive Array Cache Module incompatible with this controller... 57 1808-Slot X Drive Array Cache Module critical error... 57 1809- Slot X Encryption Failure- Communication issue prevents drive keys from being retrieved...... 57 1810- Slot X Encryption Failure- Master Key is incorrect on or not retrieved from Remote Key Manager...... 57 1811- Slot X Encryption Failure- Drive Keys not retrieved from the Remote Key Manager...... 57 1812- Slot X Encryption Failure- Invalid Drive Keys on Remote Key Manager... 58 1814- Slot X Encryption Failure- Communication issue prevents keys from being retrieved...... 58 1815- Slot X Encryption Failure- All encrypted logical drives are offline due to failure to enter proper Controller Password...... 58 1816- Slot X Encryption Failure- Encrypted logical drives are present but encryption is not yet enabled...... 58 1817- Slot X Encryption Failure- Encryption is enabled for the controller but the Master Key name is not set...... 58 1818- Slot X Encryption Failure- Key Management Mode mismatch between controller and drives...... 58 1819- Slot X Encryption Failure- Unsupported System ROM detected...... 58 1820- Slot X Encryption Failure- Encrypted logical drives are offline...... 58 1821- Slot X Encryption Failure- FW version for this controller does not support HP Secure Encryption...... 59 1822- Slot X Encryption Failure Imported encrypted logical drives are offline... 59 1823- Slot X Encryption Failure- Unsupported ilo FW detected...... 59 1824-Slot X One or more storage cables has failed preventing discovery of attached storage... 59 1825- Slot X Encryption Failure- Non-volatile storage corrupted: Critical Security Parameters erased per policy...... 59 1826- Slot X Encryption Failure- Encryption engine hardware failure...... 59 1827-Slot X Drive Array Please install cache module battery pack... 59 1828- Slot X Drive Array Cache Module Battery Pack is not installed... 59 1829-Slot # Drive Array Please replace cache module battery pack... 60 xiv FRWW

1830-Slot X Drive Array Incorrect cache module power source detected... 60 1831- Slot X Drive Array Data in Write-Back SmartCache has been lost... 60 1832- Slot X One or more physical drives are not exposed to the host due to presence of logical unit metada... 60 1833-Slot X Drive Array Unsupported Array Configuration Detected... 60 Messages d'erreur du journal de maintenance intégré... 60 Présentation des messages d'erreur du journal de maintenance intégré... 60 Automatic operating system shutdown initiated due to fan failure... 61 Automatic Operating System Shutdown Initiated Due to Overheat Condition...... 61 Operating System failure: Cause [NT]... 61 Corrected Memory Error Threshold exceeded (Processor X, Memory Module Y)... 61 Uncorrectable PCI Express Error (Slot X, Bus Y, Device Z, Function W, Error status <hex value>)... 61 Uncorrectable Machine Check Exception (Board X, Processor Y, APIC ID <hex value>, Bank <hex value> Status <hex value>)... 61 System Fan Failure (Fan X, Location)... 61 System Fans Not Redundant... 62 System Overheating (Zone X, Location)... 62 System Power Supplies Not Redundant... 62 System Power Supply Failure (Power Supply X)... 62 Uncorrectable Memory Error (Slot X, Memory Module Y)...... 62 3 Codes de défaut d'alimentation de HP ProLiant Gen9... 63 Codes de défaut d'alimentation des voyants du panneau avant... 63 4 Erreurs HP Smart Array... 64 Voyants d'exécution de contrôleur... 64 Voyants du contrôleur P440ar... 64 Voyants du contrôleur P440... 65 Voyants du contrôleur P441... 66 Voyants du contrôleur P840... 67 Voyants du module de cache... 68 Messages du journal des évènements de Windows - Smart Array... 70 Identifiants de message 24578-24599... 70 Identifiants de message 24600-24624... 81 Identifiants de message 24625-24649... 87 Identifiants de message 24650-24674... 90 Identifiants de message 24675-24699... 95 Identifiants de message 24700-24724... 100 Identifiants de message 24725-24749... 111 Identifiants de message 24750-24774... 116 FRWW xv

Identifiants de message 24775-24799... 123 Identifiants de message 24800-24808... 131 Erreurs de driver Windows, Smart Array... 133 5 Erreurs HP Onboard Administrator... 135 Messages d'erreur du module Onboard Administrator... 135 Erreurs Onboard Administrator... 135 Erreurs de capture d'écran Insight Display... 157 Messages SysLog... 158 Messages du journal - Alertmail... 158 Message du journal - Authentification et démarrage... 159 Messages du journal - CGI... 159 Messages du journal - CLI... 159 Messages du journal - Baie d'interconnexion... 160 Messages du journal - DHCP... 160 Messages du journal - Enclosure-Link... 161 Messages du journal - Configuration non volatile... 163 Messages du journal - Flash microprogramme... 164 Messages du journal - Certificat flash, configuration et stockage... 165 Messages du journal - DNS... 167 Messages du journal - LCD... 168 Messages du journal - Opérations... 169 Messages du journal - Linux... 178 Messages du journal - Gestion... 178 Messages du journal interne OA... 186 Messages du journal - LDAP... 187 Messages du journal - Redondance... 188 Messages du journal - SSO... 189 Messages du journal - Two Factor... 189 Messages du journal - FIPS... 190 Messages du journal - VLAN... 190 Interruptions SNMP du module Onboard Administrator... 191 Notifications d'évènements de boîtier... 192 Notifications d'évènements de ligne de commande... 193 6 Erreurs HP Virtual Connect... 195 Présentation de SNMP... 195 Interruptions SNMP... 196 Interruptions MIB du module VC... 199 Interruptions MIB du domaine VC... 201 Interruptions État du domaine VC géré modifié... 201 xvi FRWW

Interruptions de point de contrôle du domaine VC... 205 vcdomainstackinglinkredundancystatuschange... 205 vctesttrap... 205 Évènements SysLog Virtual Connect... 205 Évènements de domaine (1000-1999)... 206 1003 - VCM-OA communication down (Panne de communication entre VCM et OA)... 206 1022 - Domain state FAILED (ÉCHEC de l'état du domaine)... 207 1023 - Domain state PROFILE_FAILED (État de domaine : PAS DE COMMUNICATION)... 207 1026 - Domain state NO_COMM (État de domaine : PAS DE COMMUNICATION)... 208 Évènements de boîtier (2000-2999)... 208 2003 - Enclosure import failed (Échec d'importation du boîtier)... 208 2011 - Enclosure state NO_COMM (État du boîtier : NO_COMM)... 208 2013 - Enclosure state failed (Échec de l'état du boîtier)... 209 2016 - Enclosure Find failed (Échec de recherche de boîtier)... 209 Évènements du module Ethernet (3000-3999)... 210 3009 - Enet Module OA CPU Fault Event (Évènement de panne OA du module Ethernet)... 210 3012 - Enet Module State FAILED (État du module Ethernet : ÉCHEC)... 210 3014 - Enet Module state INCOMPATIBLE (État du module Ethernet MANQUANT)... 211 3019 - Enet Module state MISSING (État du module Ethernet MANQUANT)... 212 3023 - Enet Module state NO_COMM (État du module Ethernet : NO_COMM)... 212 3031 - Enet Module IP is 0.0.0.0 (Adresse IP du module Ethernet : 0.0.0.0). 213 3101 - Port is disabled as network loop is detected (Le port est désactivé si une boucle réseau est détectée)... 213 3102 - Port was disabled because a pause flood was detected (Le port a été désactivé car une saturation de pause a été détectée)... 213 Évènements du module FC (4000-4999)... 214 4009 - FC Module OA CPU Fault Event (Évènement de panne du processeur OA du module FC)... 214 4012 - FC Module State Failed (État du module FC : échec)... 214 4014 - FC Module State Incompatible (État du module FC incompatible)... 214 4019 - FC Module State is NO_COMM (État du module FC : NO_COMM)... 215 Évènements de serveur (5000-5999)... 215 5009 - Server OA fault event (évènement de panne du module OA du serveur)... 215 5012 - Server state FAILED (État du serveur : INCOMPATIBLE)... 215 FRWW xvii

5014 - Server state INCOMPATIBLE (État du serveur : INCOMPATIBLE)... 216 5019 - Server state is NO_COMM (État du serveur : NO_COMM)... 216 5022 - Missing information for one or more blades of a multi-blade server (Des données sont manquantes concernant une ou plusieurs lames dans le serveur multi-lame)... 216 5050 - The BIOS for the following devices is not compatible with Virtual Connect (Le BIOS des périphériques suivants n'est pas compatible avec Virtual Connect)... 216 5055 - The server BIOS needs to be updated to at least the version dated (Le BIOS du serveur doit être mis à jour à la dernière version datée)... 217 5056 - Unable to release power hold on the server (Impossibilité de dégager la prise d'alimentation sur le serveur) Annulez son affectation et attribuez-lui un nouveau profil... 217 Évènements de profil (6000-6999)... 217 6012 - Profile state FAILED (État du profil : ÉCHEC)... 217 6020 - Profile has the same network on two Flex-10 NICs on the same physical port (Le profil a le même réseau sur deux cartes réseau du même port physique)... 217 6021 - Profile has PXE enabled on a non-primary Flex-10 NIC (PXE est activé sur une carte réseau Flex-10 qui n'est pas la carte principale)... 217 6022 - Profile has iscsi boot enabled on an unsupported Flex-10 NIC (Le profil comporte un démarrage iscsi activé sur une carte réseau Flex-10 qui n'est pas prise en charge)... 218 6023 - Profile is assigned to a multi-blade server that has data missing (Le profil est assigné à un serveur multi-lame qui a des données manquantes).. 218 6030 - Profile could not be assigned to powered up server (Le profil n'a pas pu être affecté au serveur alimenté)... 218 Évènements du réseau Ethernet (7000-7999)... 219 7012 - Enet Network state FAILED (État du réseau Ethernet : DÉSACTIVÉ) 219 7014 - Enet Network state DISABLED (État du réseau Ethernet : DÉSACTIVÉ)... 219 Évènements de la structure FC (8000-8999)... 219 8012 - FC Fabric state FAILED (État de la structure FC : ÉCHEC)... 219 Évènements de module inconnu (9000-9999)... 220 9012 - Unknown Module state FAILED (État de module inconnu : INCOMPATIBLE)... 220 9014 - Unknown Module state INCOMPATIBLE (État de module inconnu : INCOMPATIBLE)... 220 9019 - Unknown Module state NO_COMM (État de module inconnu : NO_COMM)... 220 Évènements uplinkset Enet (17000-17999)... 221 17012 - Enet uplinkset state FAILED (État uplinkset Enet : ÉCHEC)... 221 xviii FRWW

17014 - Enet uplinkset state is DISABLED (État uplinkset Enet : DÉSACTIVÉ)... 221 7 Erreurs CONREP... 222 Utilisation de CONREP... 222 Codes renvoyés par CONREP... 222 Sortie écran CONREP... 223 8 Erreurs ilo HP... 225 Présentation d'ilo... 225 Voyants du POST ilo... 225 Entrées du journal des évènements... 226 Messages RIBCL... 234 9 Identifiants d'évènements Microsoft Windows et interruptions SNMP... 241 Messages du journal d'évènements associés aux interruptions SNMP... 241 Les pages suivantes récapitulent les évènements HP Insight Management entrés dans le journal d'évènements Microsoft Windows NT lorsqu'ils surviennent... 241 Descriptions des agents... 242 Agents de fondation... 242 Identifiants d'évènements 1105-1808... 242 Identifiants d'évènements 2048-2359... 252 Identifiants d'évènements 3072-3876... 255 Identifiants d'évènements 4352-4626... 260 Agents de stockage... 263 Identifiants d'évènements 256-774... 263 Identifiants d'évènements 1061-1098... 267 Identifiants d'évènements 1101-1199... 275 Identifiants d'évènements 1200-1294... 305 Identifiants d'évènements 1343-4613... 324 Agents de serveur... 329 Identifiants d'évènements 256-1024... 329 Identifiants d'évènements 1025-1092... 333 Identifiants d'évènements 1103-1183... 342 Identifiants d'évènements 1539-3352... 379 Identifiants d'évènements 5632-5684... 382 Agents de carte réseau... 384 Identifiants d'évènements 256-299... 384 Identifiants d'évènements 300-1293... 389 FRWW xix

10 Assistance et autres ressources... 396 Avant de contacter HP... 396 Informations de contact HP... 396 11 Acronymes et abréviations... 397 12 Commentaires sur la documentation... 401 Index... 402 xx FRWW

1 Introduction Présentation Ce manuel fait partie d'un ensemble de deux volumes. Le volume I, Manuel de résolution des problèmes liés aux serveurs HP ProLiant Gen9, Volume I : résolution des problèmes propose des procédures de résolution des problèmes les plus fréquents. Ce manuel, Volume II : Messages d'erreur contient une liste des messages d'erreur et des informations permettant d'interpréter et de régler les messages d'erreur sur les serveurs et lames de serveur ProLiant. Ces messages vous permettent de résoudre les problèmes liés à votre équipement HP et d'optimiser le fonctionnement de celui-ci. Résolution des problèmes de ressources Le Manuel de résolution des problèmes HP ProLiant Gen9, Volume I : dépannage fournit des procédures de dépannage des problèmes courants et des cours complets sur la détection et l'identification des pannes, la résolution des problèmes et la maintenance logicielle sur les serveurs ProLiant et les lames de serveur. Pour consulter ce manuel, sélectionnez une langue : Anglais (http://www.hp.com/support/gen9_tsg_en) Français (http://www.hp.com/support/gen9_tsg_fr) Espagnol (http://www.hp.com/support/gen9_tsg_es) Allemand (http://www.hp.com/support/gen9_tsg_de) Japonais (http://www.hp.com/support/gen9_tsg_ja) Chinois simplifié (http://www.hp.com/support/gen9_tsg_zh_cn) FRWW Présentation 1

2 Erreurs sur les serveurs HP ProLiant Messages d'erreur de diagnostic de module RAID Messages d'erreur de l'utilitaire de diagnostic HP Smart Storage Administrator Cette section contient une liste alphabétique complète de tous les messages d'erreur présentés par HP Smart Storage Administrator Diagnostics Utility dans le rapport de diagnostic de module RAID. Array status: The array has failed Action : Contrôlez les unités physiques ou logiques en défaut dans le module RAID et corrigez la cause de l'échec. Array status: The array currently has a drive erase operation queued, running, stopped or completed on a logical or physical drive Action : Aucune intervention n'est requise. Array Status: The array has a spare drive assigned which is smaller than the smallest data drive in the array Some operations in the array will not be available Action : Remplacez le disque de secours par un autre disque dont la taille est au moins la taille du plus petit disque de données dans le module RAID. Cache module: The batteries were hot-removed Action: Remplacez les batteries. Cache module: The cache is disabled because the batteries are low on the redundant controller Action : Remplacez les batteries si elles ne sont pas rechargées dans les 36 heures. Cache module: The cache for this controller is temporarily disabled since a snapshot is in progress......the controller requires a reboot to enable the cache. Until the reboot occurs, cache module operations such as Expansion, Extension, and Migration are disabled Action : Redémarrez le contrôleur pour activer le cache. Jusqu'à ce que le redémarrage se produise, les opérations du module de cache telles que l'expansion, l'extension et la migration sont désactivées. Cache module: The cache is disabled because the batteries are low Action : Remplacez les batteries si elles ne sont pas rechargées dans les 36 heures. 2 Chapitre 2 Erreurs sur les serveurs HP ProLiant FRWW

Cache module: This controller has been set up to be a part of a redundant pair of controllers......but the cache module cache sizes are different on the two controllers. Make certain that both controllers are using cache modules with the same amount of cache memory installed Action : Ajustez la mémoire installée dans les modules de cache pour faire correspondre les tailles. Cache module: The cache is disabled because the restore operation from flash memory failed Action : Réinstallez le module de cache du contrôleur. Si le problème persiste, contactez l'assistance HP (Informations de contact HP à la page 396). Cache module: The cache is disabled because the charge on the flash-memory capacitor is too low Action : Remplacez le condensateur si le condensateur ne se recharge pas dans les 10 minutes. Cache module: The cache is disabled because a capacitor has failed to charge to an acceptable level Action : Remplacez le condensateur. Cache module: The cache is disabled because the backup operation to flash memory failed Action : Réinstallez le module de cache du contrôleur. Si le problème persiste, contactez l'assistance HP (Informations de contact HP à la page 396). Cache module: The cache is disabled because there are no capacitors attached to the cache module Action : Installez un condensateur. Cache module: The cache is disabled because a flash memory or capacitor hardware failure has been detected Action : Contactez l'assistance HP (Informations de contact HP à la page 396). Cache module: This controller's firmware is not backward compatible with the cache module revision Action : Mettez le contrôleur à la dernière version du microprogramme. Si le problème persiste, contactez l'assistance HP (Informations de contact HP à la page 396). Controller State: The array controller contains a volume that was created with a different version of controller firmware and is not backward-compatible with the current version of firmware. You may reconfigure the controller, but the existing configuration and data will be overwritten and potentially lost Action : Mettez le contrôleur à la dernière version du microprogramme. Si le problème persiste, replacez les unités configurées sur le contrôleur d'origine. FRWW Messages d'erreur de diagnostic de module RAID 3

Controller State: The array controller contains more logical drives than are supported in the current configuration Any configuration command (e.g. logical drive creation, array expansion, etc.) or modification to the controller will result in the loss of all existing data on the disabled volume(s) Action : Identifiez les disques qui contiennent les volumes logiques perdus. Déplacez ces disques vers un autre contrôleur, où les volumes logiques peuvent être recréés. Si un disque contient un volume logique valide qui est utilisé et un volume logique perdu, ne déplacez pas ce disque vers un autre contrôleur. Controller State: The array controller contains one or more logical drives with a RAID level that is not supported in the current configuration Any configuration command (e.g. logical drive creation, array expansion, etc.) or modification to the controller will result in the loss of all existing data on the disabled volume(s) Action : Effectuez l'une des actions suivantes : Si ce message est observé après le déplacement d'un module RAID de disques configurés à partir d'un autre contrôleur, mettez à niveau le microprogramme de ce contrôleur. En outre, vérifiez si le module de cache est installé. Installez le module de cache s'il n'est pas présent. Si cela ne résout pas le problème, mettez le serveur hors tension et déplacez les disques vers le contrôleur d'origine. Si ce message est observé sans mouvement de disque, vérifiez si le module de cache est en panne et remplacez-le si nécessaire. Si le problème persiste, contactez l'assistance HP (Informations de contact HP à la page 396). Controller State: The array controller contains redundant connections to one or more physical drives that are not supported in the current configuration Please remove the redundant connection(s) or, if your controller supports it, install the appropriate license key to enable the dual domain feature Action : Prenez l'action appropriée comme indiqué dans le message. Controller State: The array controller is connected to an expander card or an external enclosure and is operating without a memory board. If there are physical drives attached to the expander card or external enclosure, and those drives contain any logical drives, then making any configuration change will lead to potential data loss on those logical drives Action : Installez un module de mémoire cache. Controller State: The array controller is operating without a memory board and contains one or more logical drives with a RAID level that is not supported in the current configuration. Any configuration command (e.g. logical drive creation, array expansion, etc.) or modification to the controller will result in the loss of all existing data on the disabled volume(s) Action : Installez un module de mémoire cache. 4 Chapitre 2 Erreurs sur les serveurs HP ProLiant FRWW

Controller State: The array controller is operating without a memory board and has a bad volume position Any configuration command (e.g. logical drive creation, array expansion, etc.) or modification to the controller will result in the loss of all existing data on the disabled volume(s) Action : Installez un module de mémoire cache. Controller State: The array controller is operating without a memory board and contains more logical drives than are supported in the current configuration Any configuration command (e.g. logical drive creation, array expansion, etc.) or modification to the controller will result in the loss of all existing data on the disabled volume(s) Action : Installez un module de mémoire cache. Controller State: The array controller is operating without a memory board and has an invalid physical drive connection Any configuration command (e.g. logical drive creation, array expansion, etc.) or modification to the controller will result in the loss of all existing data on the disabled volume(s) Action : Installez un module de mémoire cache. Controller State: The array controller has a configuration that requires more physical drives than are currently supported You may reconfigure the controller, but the existing configuration and data will be overwritten and potentially lost Action : Effectuez l'une des actions suivantes : Si ce message est observé après le déplacement d'un module RAID de disques configurés à partir d'un autre contrôleur, mettez à niveau le microprogramme de ce contrôleur. En outre, vérifiez si le module de cache est installé. Installez le module de cache s'il n'est pas présent. Si cela ne résout pas le problème, mettez le serveur hors tension et déplacez les disques vers le contrôleur d'origine. Si ce message est observé sans mouvement de disque, vérifiez si le module de cache est en panne et remplacez-le si nécessaire. Si le problème persiste, contactez l'assistance HP (Informations de contact HP à la page 396). Controller State: The array controller has an unknown disabled configuration status message Any configuration command (e.g. logical drive creation, array expansion, etc.) or modification to the controller will result in the loss of all existing data on the disabled volume(s) Action : Contactez l'assistance HP (Informations de contact HP à la page 396). Controller State: The array controller has an unsupported configuration You may reconfigure the controller, but the existing configuration and data will be overwritten and potentially lost Action : Effectuez l'une des actions suivantes : Si ce message est observé après le déplacement d'un module RAID de disques configurés à partir d'un autre contrôleur, mettez à niveau le microprogramme de ce contrôleur. En outre, FRWW Messages d'erreur de diagnostic de module RAID 5