MODE DE LIGNE : tension de secteur d'onde sinusoïdale 120 V (-13% / +15%), MODE DE PILE : sortie d'onde sinusoïdale 120 V (+/-5 %)

MODULES ÉLECTRIQUES. - systèmes électriques DC - onduleurs - convertisseurs - interrupteurs statiques. Notre alimentation Votre confiance

Notice Technique / Technical Manual

PROJECT POUR LE SYSTÈME DE SURVEILLANCE PAR CAMERA BASÉ SUR TECHNOLOGIE AXIS, PANNEAUX SOLAIRES ET LUMIERE DU LEDS BLOC D APARTEMENT LAURIER.

Fabricant. 2 terminals

Nova AVR 500 Nova AVR 625 Nova AVR 1250

SERIE TS-770 SYSTEME CONFERENCE


POWER + SA Series 10kVA-40kVA & "POWER kVA-20kVA. Notre alimentation Votre confiance

Master4Light. Caractérisation Optique et Electrique des Sources Lumineuses. Equipement 2-en-1 : source de courant et spectrophotomètre

Spécial Catégorie 6 Patch Cords

AMC 120 Amplificateur casque

Logitech Speaker System Z553 Setup Guide Guide d installation

fullprotect inside EOLE SPEie RS E-SPEie V-0.6A-RS 1.0 revision Protection environnement Datasheet édition française

Unité de pompage SKF Maxilube. pour SKF DuoFlex, systèmes de lubrification double ligne

Flottes privatives Une gestion maîtrisée Fleet management The management expert

Curve. Innover pour simplifier! Mistral signe les fontaines High Tech à hauteur adaptable. Mistral signs the High Tech coolers with adaptable height

Paxton. ins Net2 desktop reader USB

Moteur DC: Comment faire varier sa vitesse?

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

I ntroduction. Coffrets pour la régulation de la température et de l hygrométrie. Caractéristiques et avantages

PVCHECK Rel /11/12

Guide d'installation rapide TFM-560X YO.13

User guide Conference phone Konftel 100

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Relais d'arrêt d'urgence, protecteurs mobiles

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

Références pour la commande

TM238LDA24DR 230VAC - RELAYS OUTPUTS -

TRAITEMENT DE DONNÉES

RAMOS ULTRA FICHE TECHNIQUE CONTEG. Tous droits réservés, 2014 CONTEG SYSTÈMES COMPLÉMENTAIRES. CONTEG, spol. s r.o. version:

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

Owner s Manual SmartOnline

Service correctionnel du Canada Direction des services techniques Systèmes électroniques NORMES EN ÉLECTRONIQUE

DX400E-FR / DX600E-FR / DX800E-FR Manuel d utilisation

CONTRÔLE DE BALISES TYPE TB-3 MANUEL D'INSTRUCTIONS. ( Cod ) (M H) ( M / 99G ) (c) CIRCUTOR S.A.

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

Contrôle d'accès Access control. Notice technique / Technical Manual

Fiche technique CPU 314SC/DPM (314-6CG13)

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

EX RT 7/11 Manuel d'installation et d'utilisation

Procédure de test pour réception câblage LANmark-7

SYSTÈME DE GAINES À SPIRALE ET RACCORDS TOURNANTS

POLICY: FREE MILK PROGRAM CODE: CS-4

RELEVÉ DES RÉVISIONS

ONDULEURS TRIPHASÉS SMARTONLINE

AUTO ER ADAPT ER SPECIAL USE WARNING

Série 77 - Relais statiques modulaires 5A. Caractéristiques. Relais temporisés et relais de contrôle

domovea tebis La maison sous contrôle

Instructions Mozilla Thunderbird Page 1

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Relais statiques SOLITRON MIDI, Commutation analogique, Multi Fonctions RJ1P

CHARGEURS AUTOMATIQUES DE BATTERIE AUTOMATIC BATTERY CHARGERS

Système ASC unitaire triphasé. PowerScale kva Maximisez votre disponibilité avec PowerScale

UMG 20CM. UMG 20CM Appareil de surveillance des circuits de distribution avec 20 entrées et RCM. Analyse d harmoniques RCM. Gestion d alarmes.

Garage Door Monitor Model 829LM

Fronius IG. Onduleurs centraux PV POWERING YOUR FUTURE

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Configurateur TX100B tébis KNX avec prise USB

Igloo. Congélateurs Ultra-Froid -45 o C & -86 o C Armoires & Coffres 370 à 830 litres

Switches Gigabit ProSAFE Plus

H E L I O S - S T E N H Y

TP TP4-20 GSM. Système d alarme sériel extensible. Les systèmes d alarme TP4-20 et TP4-20 GSM concilient la

Technique de sécurité

Mode d emploi ALTO MONITOR PROCESSEUR D ÉCOUTE. Version 1.0 Juillet 2003 Français

Module Relais de temporisation DC V, programmable

MODULAIRE REDONDANT EVOLUTIF FLEXIBLE

Relais d'arrêt d'urgence, protecteurs mobiles

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

User Manual Guide d utilisation

Switches ProSAFE Plus Gigabit

08/07/2015

Pour les PME. Solutions de vidéosurveillance sur IP Cisco

Une production économique! Echangeur d ions TKA

Mesure. Multimètre écologique J2. Réf : Français p 1. Version : 0110

Fonctions intégrées. Nouvelles solutions universelles & système de communication

Protect 5.31 Sortie monophasée 10kVA 120kVA Protect 5.33 Sortie triphasée 25kVA 120kVA. Alimentations Statique Sans Interruption

StruxureWare Power Monitoring Expert v7.2

ad notam Applications et Solutions

Relais statiques SOLITRON, 1 ou 2 pôles Avec dissipateur intégré

Summary / Sommaire. 1 Install DRIVER SR2 USB01 Windows seven 64 bits / Installation du DRIVER SR2 USB01 Windows seven 64 bits 2

Fiche produit Fujitsu ETERNUS JX40 Baie de stockage JBOD

Stainless Steel Solar Wall Light

Commutateur statique de transfert Liebert La solution incontournable pour vos systèmes d alimentation à haute disponibilité

Once the installation is complete, you can delete the temporary Zip files..

Contents Windows

Fiche technique : Vérifiez la connectivité du réseau en moins de 10 secondes

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

User s Manual CPS3500PIE/CPS3500PRO/CPS3500STD CPS5000PIE/CPS5000PRO/CPS5000STD

DI-1. Mode d'emploi. Direct Box

How to Login to Career Page

Owner s Manual. SmartOnline Single-Phase 5kVA, 6kVA & 10kVA Intelligent True On-Line UPS Systems (Rackmount/Tower)

Spécifications détaillées

Manuel de référence O.box

Product Overview Présentation produits

Système avancé de contrôle pour câble chauffant. Configuration à distance et surveillance à l'aide du logiciel DigiTrace Supervisor

INSTITUT MARITIME DE PREVENTION. For improvement in health and security at work. Created in 1992 Under the aegis of State and the ENIM

Glossaire technique Veditec

Transcription:

OmniSmart 120V 330VA 225W UL 60601-1 Medical Grade Line-Interactive UPS, Tower, DB9 Serial NUMÉRO DE MODÈLE: OMNISMART350HG Points principaux 330VA line interactive tower UPS Maintains sine-wave 120V nominal output over an input range of 83 to 132V Professional features include serial port, hospital grade plug & outlets, built-in isolation transformer and UL60601-1 listing Input: Hospital-grade NEMA 5-15P (120V 15A) / Output: 4 Hospital-grade NEMA 5-15R (120V) 2 line phone suppression for TEL/DSL line protection Leakage current less than 100 microamps Inclut dans l'emballage Présentation générale OMNI SMART 350HG Hospital Tripp Lite's OMNI SMART 350HG offers medical-grade UPS protection with built-in line interactive voltage Grade UPS System regulation, intelligent monitoring and unattended shutdown capability. Hospital-grade plug & outlets, plus built-in Serial cable for remote monitoring isolation transformer with Faraday shield offers full isolation and removes common mode noise equal to 100 Warranty information microamps. UL 60601-1 listed as medical electrical equipment. 330VA power handling capacity supports Instruction manual computers, inter-networking equipment and other critical loads during commercial power failures. Line interactive voltage regulation corrects brownouts as low as 83V back to normal 120V levels, saving battery reserves for use only during complete power failures. Includes, 2 line phone surge suppression and built-in DB-9 communications port that works with PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications. Fonctionnalités Ideal UPS protection for applications in medical patient-care areas where UL 60601-1 listed electrical medical equipment is required Line-interactive voltage regulation corrects brownouts as low as 83V without using battery power Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections Full line isolation prevents shock potential and operational problems in sensitive electronic equipment Resistant to electrostatic discharge Supports loads up to 330VA/225 watts 46 minutes half load runtime (with 165VA load), 18 minutes full load runtime (with 330VA load) 4 protected hospital-grade outlets; 6-ft. cord 1-DB9 serial port for network interface Complete surge protection, line isolation and EMI/RFI noise filtering 2 phone line surge suppression for modems, fax machines and other phone accessories Complete remote monitoring cabling included, PowerAlert UPS management software available via free download 4 diagnostic LEDs indicate AC present, on battery, voltage correction & battery low/replace Battery replacement door and back panel grounding lug 1 / 5

Caractéristiques Sortie Puissance en volts-ampères (VA) 330 Capacité en sortie (Watts) 225 Tension(s) de sortie nominale(s) prise(s) en charge Compatibilité avec fréquences Régulation de la tension de sortie (mode ligne) Régulation de la tension de sortie (mode batterie) 120 V 60 Hz -18%, +8% +/- 5% Prises de sortie (4) 5-15R Détails des prises de sortie Forme d'onde CA de sortie (mode CA) Forme d'onde de sortie CA (mode Batterie) Hospital grade output receptacles Sine wave Signal sinusoïdal à modulation d'impulsions en largeur Entrée Courant d'entrée nominal (charge maximale) Tension(s) d'entrée nominale(s) prise(s) en charge Type de connexion d'entrée de l'onduleur (UPS) 2.3A 120 V CA 5-15P-HG Disjoncteurs de circuit d'entrée 3.5A Longueur du cordon d'entrée de l'onduleur (pi) Longueur du cordon d'entrée de l'onduleur (m) Service électrique recommandé Phase en entrée 6 1.8 15A 120V Monophasé Batterie Durée de fonctionnement à pleine charge (min.) Durée de fonctionnement à demi-charge (min.) 18 min. (225w) 46 min. (115w) Tension du système CC (V CC) 12 2 / 5

Taux de recharge des batteries (Batteries incluses) Cartouche de batterie de rechange de l'onduleur interne Accès aux batteries Description du remplacement de la batterie Autonomie extensible Less than 4.5 hours from 10% to 90% RBC52(quantity 2) Battery access door Hot-swappable, user replaceable batteries Non Régulation de tension Description de la régulation de tension Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89 Correction des sous-tensions Input voltages between 89 and 107 are boosted by 14% Interface Utilisateur, Alarmes et Contrôles Switches Fonctionnement de l'annulation d'alarme Alarme sonore Indicateurs LED 2 Switches control off/on power status and alarm-cancel/self-test operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status Audible alarm indicates power-failure and low-battery conditions 4 LEDs indicate line power, battery power, overload and battery low/replace status Suppression de Bruit / Surtensions Temps de réponse suppression CA onduleur Suppression de la ligne de données de l'onduleur Suppression de bruit CA RFI / IEM Instantaneous 2 lignes TEL/DSL Oui ISOLATION Transformateur d'isolement de sortie Hospital grade load isolation transformer Physiques Facteurs de forme d'installation pris en charge avec accessoires inclus Facteurs de forme d'installation pris en charge avec accessoires optionnels Facteur de forme primaire Dimensions du module d'alimentation de l'onduleur (hlp, po) Dimensions du module d'alimentation de l'onduleur (hlp, cm) Tour Montage mural (UPSWM - kit de montage en tour) Tour 10.8 x 5.2 x 7.2 27.3 x 13.3 x 18.4 3 / 5

Poids du module d'alimentation de l'onduleur (livres) Poids du module d'alimentation de l'onduleur (kg) Dimensions d'expédition de l'onduleur (hlp / po) Dimensions d'expédition de l'onduleur (hlp / cm) 25 11.4 14 x 8.5 x 11 35.6 x 21.6 x 27.9 Poids d'expédition (livres) 28 Poids d'expédition (kg) 12.7 Matériau du boîtier de l'onduleur PVC Ecologique Plage de température de fonctionnement Plage de température de stockage Humidité relative +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius 0 to 95%, non-condensing BTU mode CA / Hr. (pleine charge) 48.8 BTU mode batterie / Hr. (pleine charge) Coefficient de rendement mode CA (Charge 100 %) 215.8 94% Communication Interface de communication Logiciel PowerAlert Câble de communications Série DB9 For local monitoring via the UPS s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert DB9 serial cable included Transfert Ligne / Batterie Temps de transfert Transfert basse tension vers alimentation batterie (Consigne) Transfert haute tension vers alimentation batterie (Consigne) 2-4 milliseconds 89 139 Fonctions spéciales Cosse de mise à la terre Démarrage à froid (Démarrage en mode batterie pendant une coupure de courant) Fonctions de haute disponibilité de l'onduleur Grounding lug Cold-start operation supported Batteries remplaçables à chaud 4 / 5

Certifications Certifications onduleur Testé selon la norme UL1778 (États-Unis); Testé selon les normes CSA (Canada); Certifié FCC Part 15 Category B (EMI); Testé selon la norme UL60601-1 (classe médicale) Garantie Période de garantie du produit (Mondiale) Garantie limitée de 2 ans 2016 Tripp Lite. Tous les droits sont réservés. Tous les noms de produits et de sociétés sont des marques commerciales ou des marques déposées de leurs détenteurs respectifs. Leur utilisation ne comporte aucune affiliation avec ou approbation par eux. Tripp Lite a une politique d'amélioration continue. Les spécifications sont sujettes à modification sans préavis. Tripp Lite utilise les agences primaires et de tiers pour tester ses produits pour conformité aux normes. Voir la liste des agences d essais de Tripp Lite: 5 / 5