Detecteur Autonome GSH/GSLS-(CO2)

Documents pareils
Contrôle d'accès Access control. Notice technique / Technical Manual

Garage Door Monitor Model 829LM

Master4Light. Caractérisation Optique et Electrique des Sources Lumineuses. Equipement 2-en-1 : source de courant et spectrophotomètre

Surveillance de Scripts LUA et de réception d EVENT. avec LoriotPro Extended & Broadcast Edition

Notice Technique / Technical Manual

Paxton. ins Net2 desktop reader USB

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Le No.1 de l économie d énergie pour patinoires.

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

DGA. Self Contained Digicode Keypad Digicode avec électronique intégrée INSTALLATION MANUAL MANUEL D INSTALLATION. Group Company

SERIE TS-770 SYSTEME CONFERENCE

Fabricant. 2 terminals

I ntroduction. Coffrets pour la régulation de la température et de l hygrométrie. Caractéristiques et avantages

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Contents Windows

Classes of protection IP 65 / IP66 / IP 67 ATEX zone protection Eex "ia" Eex "ed" Eex "em" ATEX II2 G/D

Module de mesure de courant pour relais statiques serie HD Module de mesure de courant HD D0340I

Centrale d alarme DA996

Fonctions intégrées. Nouvelles solutions universelles & système de communication

Application Form/ Formulaire de demande

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

Systèmes pour la surveillance et la commande lors de l entreposage et du transvasement de liquides. BA

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

AMC 120 Amplificateur casque

Instructions Mozilla Thunderbird Page 1

CAA/SE N O T I C E D E M O N T A G E E T D U T I L I S A T I O N KIT DE MONTAGE. Clavier lumineux codes DIGICODE

LE SYSTÈME D'ALARME DE GSM

WEB page builder and server for SCADA applications usable from a WEB navigator

Logitech Speaker System Z553 Setup Guide Guide d installation

NEW Fin Fan / Air cooled condenser cleaning

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

MODULES ÉLECTRIQUES. - systèmes électriques DC - onduleurs - convertisseurs - interrupteurs statiques. Notre alimentation Votre confiance

Pt 100 dispositif de commande TR 600 «Relais» avec deux sorties analogiques

Astra Elite AM/3 Manuel d'installation

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

SI SERIES. Manuel d'utilisation et de montage. Onduleur sinusoïdal STUDER INNOTEC

Z-Axis Compliance Device Compliance en z

Relais statiques SOLITRON MIDI, Commutation analogique, Multi Fonctions RJ1P

COMPASS 485/232. D Vers. 02 UNITE DE GESTION POUR COMPASS-READER

INdICAteur MISE EN SERVICE. INdICAteur. Afficheur déporté pour BAMOFLONIC PFA. MeS. Indicateur pour BAMOFLONIC /1. Code article :

Centrales d alarme incendie - SALVENA

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Instructions d Installation & Maintenance KAPTIV PURGEUR DE CONDENSAT SANS PERTE D AIR 07/09

Guide abrégé ME401-2

Description du logiciel Modbus RTU

Tableau d alarme sonore

NUGELEC. NOTICE D'UTILISATION DU B.A.A.S. du type Ma - STI / MaME - STI. pages. 1 introduction 2. 2 encombrement 3 fixation

PVCHECK Rel /11/12

Technique de sécurité

Système d alarme sans fil GSM / SMS / RFID.

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

Guide abrégé ME301-2

POLICY: FREE MILK PROGRAM CODE: CS-4

HAM841K CENTRALE D'ALARME POUR SYSTEMES DE SECURITE COMMERCIAUX ET D'HABITATION

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

Notice d'utilisation originale Safety Standstill Monitor Contrôleur d'arrêt de sécurité DA101S / / 2013

GAME CONTENTS CONTENU DU JEU OBJECT OF THE GAME BUT DU JEU

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

Boîtier de contrôle et de commande avec EV 3/2 voies intégrée

CONTRÔLE DE BALISES TYPE TB-3 MANUEL D'INSTRUCTIONS. ( Cod ) (M H) ( M / 99G ) (c) CIRCUTOR S.A.

PHANTOM. Manuel Avancé. V Révision DJI Innovations. All Rights Reserved. 1

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

CO 2 CONTROL Système de détection de gaz

Relais d'arrêt d'urgence, protecteurs mobiles

Archived Content. Contenu archivé

Neu. Technique d installation / de surveillance. VARIMETER RCM Contrôleur différentiel type B IP 5883

GE Security. KILSEN série NK700 Centrale de détection et d alarme Incendie conventionelle. Manuel d utilisation

AVOB sélectionné par Ovum

Station défibrillateur réf. SDSA1A et SDSA1AF : notice d emploi de l alarme

Centrales d alarme incendie - SALVENA

AND / ET USER GUIDE UK HARDWIRED CONTROL PANEL UK GUIDE UTILISATEUR CENTRALE D ALARME FILAIRE F

Contrôleur de débit pour système MicroCoat Manuel utilisateur

Pilotec confort 10/Pilotec confort 20 réf réf

Base casera de la alarma del GSM con el texto (ii) Más MANUAL

Une liste des distributeurs Paxton se trouve sur le site Internet -

fullprotect inside EOLE SPEie RS E-SPEie V-0.6A-RS 1.0 revision Protection environnement Datasheet édition française


SECURIT GSM Version 2

ACS-30-EU-PCM2-x-32A Régulation et surveillance du traçage électrique des bâtiments commerciaux et résidentiels pour divers domaines d application

Package Contents. System Requirements. Before You Begin

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Lavatory Faucet. Instruction Manual. Questions?

Moteur DC: Comment faire varier sa vitesse?

SYSTEMES ELECTRONIQUES NUMERIQUES

Système d alarme ProG5

MODE D EMPLOI Boitier de programmation SKY

Editing and managing Systems engineering processes at Snecma

MANUEL D INSTRUCTION

Modules d automatismes simples

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.

Traceur GPS Antivol. Le traceur est conforme aux normes européennes 95/56 E27

PROMI 500 Badges - Codes

UP 588/13 5WG AB13

GASMAN II MANUEL D UTILISATION

1. Utilisation conforme à l usage prévu. 2. Propriétés. 3. Montage. Capteur de CO 2 AMUN

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

Face Recognition Performance: Man vs. Machine

GS301-A Notice d installation et d utilisation.

How to Login to Career Page

Transcription:

Detecteur Autonome GSH/GSLS-(CO2) GB Instructions FR Instructions GSH GSLS Modèle Autonome plage 0-10000ppm Modèle Autonome plage 0-10000ppm avec Flash LED et SIRENE IS GSH_GSLS CO2 doc 1

GSH- / GSLS- (CO2) Location / Positionnement X > 50 cm Y > 20 cm H1 = 20 cm H2 =150 cm (CO 2) H3 = 20 cm GB / FR (4) - NIveau d alarme, réglage usine - Alarm levels, factory settings Dioxyde de Carbone (CO2) / (0-10000ppm) Carbon Dioxide C=2000 B=5000 A=8000 FR Ce produit est en conformité avec la directive ( LVD) 2006/95/EC & (EMC) 2004/95/EC standard: EN 61 000-6-2:2001 EN 61 000-6-3:2001 EN 61 000-3-2:2001 EN 61 000-3-3:1995 EN 61 010-1:2001 GB This product is in conformity with the directive (LVD) 2006/95/EC & (EMC) 2004/95/EC It fulfils the requirements of: EN 61 000-6-2:2001 EN 61 000-6-3:2001 EN 61 000-3-2:2001 EN 61 000-3-3:1995 EN 61 010-1:2001 IS GSH_GSLS CO2 doc 2

Detecteur Autonome GSH/GSLS-(CO2) Table d application des alarmes / Logical matrix GSLS / ALARME NEUTRALISEE 1 Heure Niveau Alarme BUZZER A Niveau Alarme FLASH LIGHT B A B Ou concentration en gaz IS GSH_GSLS CO2 doc 3

GSH- / GSLS- (CO2) GB FUNCTION When power supply is switched on, a green LED will flash to indicate power ON. This will also start the heating process of the sensor. After approximately 4 minutes the green LED will light and indicate Sensor Active. The detector has one yellow and two red LEDs. The yellow LED indicates low gas concentration (Alarm C) and the red LEDs indicate medium gas concentration (Alarm B) and high gas concentration (Alarm A). When gas is detected the LEDs (2) will light and the relay corresponding to the alarm level will change state. If alarm delay is chosen (see below) the respective LED will flash and it will light (and the relay will change state) when the chosen delay time is exceeded. GSLS: The time delay does not apply to sound & light lid. AUTOMATIC/MANUAL RESET Is managed by DIP switch (1) n o 3 where on means automatic reset and off means manual reset by pressing the Reset/Test/ Service -button (located under the cover). ALARM TIME DELAY (T1) Is managed by DIP-switches (1) n o 1 and n o 2: n o 1 n o 2 on on No alarm delay off on (1) minutes alarm delay on off (10) minutes alarm delay off off (30) minutes alarm delay FAIL SAFE Relays are in normal mode energized and will change state if power failure or if a fault situation occurs. SELF TEST FUNCTION Press the Reset/Test/Service -button (5) for 5 seconds and the test program will start and go through all LED functions and all relay functions in five seconds intervals. FAULT FUNCTION If there is a voltage drop (GV-value below 0,1V) from the sensor there is a fault situation. During the first four hours the green LED will go out and the other LED s will flash. Alarm relay C will change state. After four hours the LED Alarm B will light (other LED s will go off) and relay Alarm B will also change state. INSTALLATION Connect the detector according to the wiring diagram. SERVICE FUNCTION Pressing the Reset/Test/Service button (5) for 10 seconds will lock all alarm functions for 60 minutes. During this period it is always possible to start a new 60-minutes period by pressing the button for 10 seconds again. Return to active status is automatic at the end of the 60-minutes period or may be done manually by a single press on the Reset/Test/Service -button. When the service function is activated all LED s will flash and all relays will be in normal mode position. SOUND, LIGHT & MUTE BUTTON (GSLS only) Mute (9) button mutes the buzzer for 60 minutes. If gas concentration drops beneath A-level alarm buzzer (7) is deactivated and if gas concentration drops beneath B-level alarm LED (8) is deactivated. More details look on page 3, Logical matrix (10). ALARM THRESHOLDS The detectors are delivered with pre-set alarm. It is easy to change the thresholds by using a service adapter SA200 in combination with a voltmeter or a DT300 connected at the test terminal. (3) MAINTENANCE, ANNUAL CHECK Testing the system is recommended to be done at least twice a year. A basic function test can be made using a service tool (SA200) and a voltage meter or a DT300. Extended control and calibration requires also test gas with a specific concentration. Contact us for more information. TECHNICAL DATA Housing: Polycarbonate, PC, IP67 Power supply: GSH230 / GSLS230 85 230V AC, 50/60Hz GSH24 / GSLS24 12..24V AC/DC Power consumption: 3W Indications: Power/Active and alarm indication on three levels. Outputs relay: Potential free contacts (230V, max 5A) Ambient temp: -40 0 C..+50 0 C Humidity: Glands: Screw terminals: 0-95% Rh (non condensing) 4 of M16 membrane glands < 1,5 mm 2, fuse < 10A ATTENTION! Risk of high voltage under the lid! The device may only be opened by authorized personnel! LED A LED B LED C n 1 n 2 n 3 ALARM RESET: ON=AUTO, OFF=MANUELL n 4 not used Sensor signal for CO 2 module with range 0-10000ppm: TEST TERMINAL ALARM A ALARM B ALARM C (-) + 5VDC GV OFFSET Specifications subject to change. IS GSH_GSLS CO2 doc 4

Detecteur Autonome GSH/GSLS-(CO2) FR FONCTIONNEMENT Lorsque l'alimentation électrique est enclenchée, un voyant LED vert clignote pour indiquer que le détecteur est sous tension ( ON ). De plus, le processus de chauffe de la sonde est enclenché. Après environ 4 minutes, le voyant LED vert est allumé et indique Sensor Active (Sonde active). Le détecteur comporte un voyant LED jaune et deux voyants LED rouges. Le voyant LED jaune indique une faible concentration de gaz (alarme C). Les voyants DEL rouges indiquent une concentration de gaz moyenne (alarme B) et une concentration de gaz élevée (alarme A). Lorsque du gaz est détecté, les voyants LED (2) s'allument et le relais correspondant au niveau de l'alarme change d'état. En cas de sélection d'une temporisation d'alarme (voir cidessous), le voyant LED correspondant clignote. Il reste allumé en permanence (et le relais change d'état) lorsque la durée de temporisation sélectionnée est dépassée. GSLS : La temporisation n(agit pas sur le buzzer et la FlashLight. RÉINITIALISATION AUTOMATIQUE/MANUELLE Contrôlée par le commutateur DIP switch (1) no 3 ; "ON" indique la réinitialisation automatique et "OFF" la réinitialisation manuelle (en appuyant sur le bouton "Reset/Test/Service", situé sous le couvercle). TEMPORISATION DES ALARMES (T1) Contrôlée par les commutateurs DIP switches (1) no 1 et no 2 : No 1 No 2 ON ON Aucune temporisation d alarme OFF ON Temporisation de (1) minute ON OFF Temporisation de (10) minutes OFF OFF Temporisation de (30) minutes SÉCURITÉ INTÉGRÉE En mode de marche normal, les relais sont sous tension et change d'état en cas de panne de courant ou défaillance. FONCTION D'AUTO-VÉRIFICATION Appuyer sur le bouton "Reset/Test/Service" (5) pendant 5 secondes et le programme d'essai s'enclenche et contrôle toutes les fonctions DEL et toutes les fonctions de relais par intervalles de cinq secondes. DÉFAILLANCE Par "défaillance", il est entendu les cas où l'alimentation électrique de la sonde chute (valeur GV inférieure à 0,1 V). Pendant les quatre premières heures, le voyant LED vert est éteint et les autres voyants LED clignotent. Le relais d'alarme C change d'état. Après quatre heures, le voyant DEL "Alarm B" s'allume (les autres voyants LED s'éteignent) et le relais Alarm B change d'état. INSTALLATION Raccorder le détecteur conformément au schéma de câblage. FONCTION DÉPANNAGE/ENTRETIEN Appuyer sur le bouton "Reset/Test/Service" (5) pendant 10 secondes pour verrouiller toutes les fonctions d'alarme pendant 60 minutes. Durant cette période, il est toujours possible de lancer une nouvelle période de 60 minutes en appuyant une nouvelle fois sur le bouton pendant 10 secondes. Le retour à l'état actif se fait automatiquement à l'issue des 60 minutes ou peut être opéré manuellement en appuyant une seule fois sur le bouton Reset/Test/Service". Lorsque la fonction de dépannage/entretien est activée, tous les voyants LED clignotent et tous les relais sont en position de marche normale. SIRENE, FLASHLIGHT et BOUTON MUTE (GSLS seulement) Le bouton (9) arrête la sirène pendant 60 mn. Si la concentration de gaz descend en-dessous du niveau d alarme A, le buzzer est désactivé. Si la concentration de gaz descend en dessous du niveau d alarme B la FLASHLIGHT (8) est désactivée. Plus de détail en page 3. ÉTALONNAGE Chaque détecteur est préréglé pour un type de gaz spécifique.. Il est très facile de modifier les seuils d'étalonnage à l'aide d'un adaptateur.sa200 ou DT300 raccordé à la borne d'essai. (3) CONTRÔLE DE FONCTIONNEMENT Il est recommandé de vérifier le détecteur 2 fois par ans. Un simple test peut être effectué avec l outil SA200 ou par le DT300 connecté à la borne d essai du détecteur. Un contrôle approfondi peut être réalisé avec un gaz d essai à concentration spécifique. Nous contacter pour plus d information. CARACTERISTIQUES TECHNIQUES Boitier: Polycarbonate, PC, IP67 Alimentation: GSH230 / GSLS230 85 230V AC, 50/60Hz GSH24 / GSLS24 12..24V AC/DC Consommation: 3W Voyants d Indication: Tension/Actif et Indication des 3 niveaux d alarme. Sorties Relais: Contacts libre de potentiel (230V, max 5A) Ambiance de fonctionnement: -40 0 C..+50 0 C Humidité: 0-95% Hr (Sans condensation) Presse étoupes: 4 x M16 à membrane Bornes à vis: < 1,5 mm 2, fusible < 10A REMARQUE! Haute tension sous le couvercle! L'unité ne peut être ouverte que par du personnel autorisé Signal du capteur CO2 plage 0-10000ppm LED A LED B LED C n 1 n 2 n 3 ALARM RESET: ON=AUTO, OFF=MANUELL n 4 not used TEST TERMINAL ALARM A ALARM B ALARM C (-) + 5VDC GV OFFSET IS GSH_GSLS CO2 doc 5

GSH- / GSLS- (CO2) Dimensional Drawings/ Dimensions [mm]: IS GSH_GSLS CO2 doc 6