Powermax45 Insulator Replacement Remplacement des isolateurs du Powermax45. Field Service Bulletin Bulletin de service sur le terrain



Documents pareils
Folio Case User s Guide

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Lavatory Faucet. Instruction Manual. Questions?

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Package Contents. System Requirements. Before You Begin

Instructions Mozilla Thunderbird Page 1

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

Contents Windows

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

ENGLISH 4 FRANÇAIS 6 ESPAÑOL 8

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

Contrôle d'accès Access control. Notice technique / Technical Manual

Guide d'installation rapide TFM-560X YO.13

Logitech Speaker System Z553 Setup Guide Guide d installation

Sécurité relative aux sièges auto et aux rehausseurs

R.V. Table Mounting Instructions

PRESENTATION REMOTE TÉLÉCOMMANDE DE PRÉSENTATION. User Guide Manuel de l utilisateur

Notice Technique / Technical Manual

POLICY: FREE MILK PROGRAM CODE: CS-4

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

SYSTÈME JETS D AIR WISH WISH AIR JETS SYSTEM Système de massage à jets d air pour bains en polymère - Air jet massage system for polymer bathtubs

Paxton. ins Net2 desktop reader USB

Sun StorageTek 2500 Series

SERVEUR DÉDIÉ DOCUMENTATION

Now enhanced with powerful workplace solutions Maintenant amélioré, diet+ vous offre de puissantes solutions novatrices pour le milieu de travail

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

WEB page builder and server for SCADA applications usable from a WEB navigator

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

Start Here Point de départ Epson Stylus

Trim Kit Installation Instruction

en SCÈNE RATIONAL Rational Démonstration SDP : automatisation de la chaîne de développement Samira BATAOUCHE sbataouche@fr.ibm.com

PACKZ System Requirements. Version: Version: Copyright 2015, PACKZ Software GmbH. 1

Start Here Point de départ

Quick start guide. HTL1170B

Railway Operating Certificate Regulations. Règlement sur les certificats d exploitation de chemin de fer CODIFICATION CONSOLIDATION

22/09/2014 sur la base de 55,03 euros par action

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

Microsoft Lync de votre bureau à la salle de conférence

Logitech Wireless Performance Combo MX800 Setup Guide Guide d installation

Once the installation is complete, you can delete the temporary Zip files..

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

Credit Note and Debit Note Information (GST/ HST) Regulations

DOCUMENTATION - FRANCAIS... 2

SunATM 4.0 Release Notes

Le No.1 de l économie d énergie pour patinoires.

MODE D EMPLOI USER MANUAL

SYSTÈME DE GAINES À SPIRALE ET RACCORDS TOURNANTS

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

DOCUMENTATION - FRANCAIS... 2

Le Cloud Computing est-il l ennemi de la Sécurité?

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

Material Banking Group Percentage Regulations. Règlement fixant le pourcentage (groupe bancaire important) CONSOLIDATION CODIFICATION

Monitor LRD. Table des matières

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

Deadline(s): Assignment: in week 8 of block C Exam: in week 7 (oral exam) and in the exam week (written exam) of block D

Z-Axis Compliance Device Compliance en z

Gestion des prestations Volontaire

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Air Transportation Tax Order, Décret de 1995 sur la taxe de transport aérien CONSOLIDATION CODIFICATION

Stainless Steel Solar Wall Light

DOCUMENTATION MODULE BLOCKCATEGORIESCUSTOM Module crée par Prestacrea - Version : 2.0

HUAWEI TECHNOLOGIES CO., LTD. channelroad. A better way. Together.

VTP. LAN Switching and Wireless Chapitre 4

Vanilla : Virtual Box

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

Tom Pertsekos. Sécurité applicative Web : gare aux fraudes et aux pirates!

Secure Desktop Solution. Sébastien Marchadier ZENworks Technology Specialist

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

Interest Rate for Customs Purposes Regulations. Règlement sur le taux d intérêt aux fins des douanes CONSOLIDATION CODIFICATION

INSTITUT MARITIME DE PREVENTION. For improvement in health and security at work. Created in 1992 Under the aegis of State and the ENIM

EN UNE PAGE PLAN STRATÉGIQUE

PARIS ROISSY CHARLES DE GAULLE

ADMINISTRATION DE ADOBE LIVECYCLE MOSAIC 9.5

Form of Deeds Relating to Certain Successions of Cree and Naskapi Beneficiaries Regulations

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

Optimisez la gestion de vos projets IT avec PPM dans le cadre d une réorganisation. SAP Forum, May 29, 2013

Exemple PLS avec SAS

METTRE A NIVEAU VOTRE ORDINATEUR

Principe de TrueCrypt. Créer un volume pour TrueCrypt

RAPID Prenez le contrôle sur vos données

USB 598. Quick Start Guide (Windows) Guide de démarrage rapide (Windows) USB Modem. Modem USB.

General Import Permit No. 13 Beef and Veal for Personal Use. Licence générale d importation n O 13 bœuf et veau pour usage personnel CONSOLIDATION

Ships Elevator Regulations. Règlement sur les ascenseurs de navires CODIFICATION CONSOLIDATION. C.R.C., c C.R.C., ch. 1482

Restaurant Application Quick Reference Guide

Quick Installation Guide

La propriété intellectuelle à Hong Kong: ce qu un canadien doit savoir!

Propriétés de la matière. Material properties. Sonde de pression Pressure probe. Ref : Français p 1. English p 3.

Compte-rendu technique complet et détaillé des cookies

Manuel d'utilisation

Mobile Connect. Essai gratuit inclus. Welcome Pack. Mobile Broadband

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

Stérilisation / Sterilization

StruxureWare Power Monitoring Expert v7.2

Transcription:

Powermax45 Insulator Replacement Remplacement des isolateurs du Powermax45 Field Service Bulletin Bulletin de service sur le terrain 806070 Revision 1 April 2013 Révision 1 Avril 2013

Hypertherm, Inc. Etna Road, P.O. Box 5010 Hanover, NH 03755 USA 603-643-3441 Tel (Main Office) 603-643-5352 Fax (All Departments) info@hypertherm.com (Main Office Email) 800-643-9878 Tel (Technical Service) technical.service@hypertherm.com (Technical Service Email) 800-737-2978 Tel (Customer Service) customer.service@hypertherm.com (Customer Service Email) 866-643-7711 Tel (Return Materials Authorization) 877-371-2876 Fax (Return Materials Authorization) return.materials@hypertherm.com (RMA email) Hypertherm Plasmatechnik GmbH Technologiepark Hanau Rodenbacher Chaussee 6 D-63457 Hanau-Wolfgang, Deutschland 49 6181 58 2100 Tel 49 6181 58 2134 Fax 49 6181 58 2123 (Technical Service) Hypertherm (S) Pte Ltd. 82 Genting Lane Media Centre Annexe Block #A01-01 Singapore 349567, Republic of Singapore 65 6841 2489 Tel 65 6841 2490 Fax 65 6841 2489 (Technical Service) Hypertherm (Shanghai) Trading Co., Ltd. Unit 301, South Building 495 ShangZhong Road Shanghai, 200231 PR China 86-21-60740003 Tel 86-21-60740393 Fax Hypertherm Europe B.V. Vaartveld 9 4704 SE Roosendaal, Nederland 31 165 596907 Tel 31 165 596901 Fax 31 165 596908 Tel (Marketing) 31 165 596900 Tel (Technical Service) 00 800 4973 7843 Tel (Technical Service) Hypertherm Japan Ltd. Level 9, Edobori Center Building 2-1-1 Edobori, Nishi-ku Osaka 550-0002 Japan 81 6 6225 1183 Tel 81 6 6225 1184 Fax Hypertherm Brasil Ltda. Rua Bras Cubas, 231 Jardim Maia Guarulhos, SP - Brasil CEP 07115-030 55 11 2409 2636 Tel 55 11 2408 0462 Fax Hypertherm México, S.A. de C.V. Avenida Toluca No. 444, Anexo 1, Colonia Olivar de los Padres Delegación Álvaro Obregón México, D.F. C.P. 01780 52 55 5681 8109 Tel 52 55 5683 2127 Fax Hypertherm Korea Branch #3904 Centum Leaders Mark B/D, 1514 Woo-dong, Haeundae-gu, Busan Korea, 612-889 82 51 747 0358 Tel 82 51 701 0358 Fax 2013 Hypertherm, Inc. All rights reserved. Tous droits réservés. Powermax and Hypertherm are trademarks of Hypertherm, Inc. and may be registered in the United States and/or other countries. All other trademarks are the property of their respective holders. Powermax et Hypertherm sont des marques d Hypertherm, Inc. qui peuvent être déposées aux États-Unis et/ou dans d autres pays. Toutes les autres marques commerciales sont la propriété de leurs détenteurs respectifs.

Powermax45 Insulator Replacement DANGER! ELECTRIC SHOCK CAN KILL Disconnect electrical power before performing any maintenance. See the Safety and Compliance Manual for more safety precautions. Introduction Purpose This field service bulletin describes the steps necessary to replace the insulators in the Powermax45. Tools and materials needed #2 Phillips screwdriver 228279 Kit contents Part number Description Quantity 002535 Insulator: PMX45 Mylar 1 002536 Insulator: PMX45 Nomex (power switch) 1 002538 Insulator: PMX45 Nomex 0.010 PFC 1 Powermax45 Field Service Bulletin 806070 Revision 1 1

Powermax45 Insulator Replacement Replace the insulators 1. Turn OFF the power, disconnect the power cord, and disconnect the gas supply. 2. Use a #2 Phillips screwdriver to remove the 2 screws from the handle on the top of the power supply. Tip the end panels back slightly so that you can get the edges of the handle out from underneath them. Lift the cover off the power supply. CAUTION! Static electricity can damage circuit boards. Use proper precautions when handling printed circuit boards. Store PC boards in anti-static containers. Wear a grounded wrist strap when handling PC boards. 3. Remove the Mylar insulator that protects the power board. 4. Remove the Nomex insulator that covers the power switch. Mylar insulator Nomex insulator (power switch) Track 5. Remove the Nomex insulator that surrounds the inductor near the machine torch interface. 6. Fold all 3 insulators along their perforated edges so the insulators resemble the illustrations. 2 Powermax45 Field Service Bulletin 806070 Revision 1

Powermax45 Insulator Replacement 7. Install the new Nomex insulator (power switch) as shown in the previous figure. If necessary, remove the 4 screws that attach the power switch to help you manipulate the insulator into position around the power switch. (Refer to the figure on page 4.) 8. Install the new Nomex insulator (inductor) as shown in the following figure. 9. Install the new Mylar insulator as shown in the figure on page 2. Slide the insulator into place with the bottom edge behind the track the power supply cover rests in. The notches on each edge of the insulator should align with the ribs on the inside of the end panels. Inductor Tuck this end behind the inductor. Tuck this end under the inductor/magnetics base. 10. Being careful not to pinch any wires, slide the cover back onto the power supply. Make sure the bottom edges are in the tracks. Position the handle over the holes in the top of the cover, then use the 2 screws removed earlier to secure the cover. 11. Reconnect the gas supply and the electrical power. Powermax45 Field Service Bulletin 806070 Revision 1 3

Powermax45 Insulator Replacement If you need to remove the power switch screws 230 V CE/CSA Rear end panel Remove these 4 screws. 400 V CE / 480 V CSA Remove these 4 screws. Remove the rotary switch screw. I Rear end panel O 4 Powermax45 Field Service Bulletin 806070 Revision 1

Remplacement des isolateurs du Powermax45 DANGER! UN CHOC ÉLECTRIQUE PEUT ÊTRE MORTEL Avant tout entretien, débrancher l alimentation électrique. Se reporter au Manuel de sécurité et de conformité pour des mesures de sécurité supplémentaires. Introduction Objet Ce bulletin de service sur le terrain décrit les étapes nécessaires pour le remplacement des isolateurs du Powermax45. Outils et matériel requis Tournevis cruciforme n 2 Contenu du kit 228279 Numéro de référence Description Quantité 002535 Isolateur : Mylar PMX45 1 002536 Isolateur : Nomex PMX45 (interrupteur d alimentation) 1 002538 Isolateur : Nomex 0.010 PFC PMX45 1 Powermax45 Bulletin de service sur le terrain 806070 Révision 1 a-1

Remplacement des isolateurs du Powermax45 Remplacement des isolateurs 1. Couper l alimentation (OFF), débrancher le cordon d alimentation et débrancher l alimentation en gaz. 2. Utiliser un tournevis cruciforme n 2 pour déposer les deux vis de la poignée située sur le dessus de la source de courant. Basculer légèrement les panneaux d extrémité de façon à en extraire les bords de la poignée d en dessous. Retirer le couvercle de la source de courant en le levant. ATTENTION! L électricité statique peut endommager les cartes de circuits imprimés. Les précautions qui s imposent doivent être respectées lors de la manipulation des cartes de circuits imprimés. Les cartes de circuits imprimés doivent être rangées dans des contenants antistatiques. L utilisateur doit porter un bracelet antistatique lors de la manipulation des cartes de circuits imprimés. 3. Déposer l isolateur Mylar qui protège le circuit imprimé d alimentation. 4. Retirer l isolateur Nomex qui recouvre l interrupteur d alimentation. Isolateur Mylar Isolateur Nomex (interrupteur d alimentation) Rail 5. Déposer l isolateur Nomex qui entoure la bobine d induction près de l interface de la torche machine. 6. Plier les trois isolateurs le long de leurs bords perforés afin qu ils soient comme sur les illustrations. a-2 Powermax45 Bulletin de service sur le terrain 806070 Révision 1

Remplacement des isolateurs du Powermax45 7. Installer le nouvel isolateur Nomex (interrupteur d alimentation) comme illustré sur la figure précédente. Si nécessaire, déposer les quatre vis fixant l interrupteur d alimentation afin de vous faciliter la manipulation de l isolateur en position près de l interrupteur d alimentation. (Se reporter au schéma page 4.) 8. Installer le nouvel isolateur Nomex (bobine d induction) comme illustré sur la figure ci-dessous. 9. Installer le nouvel isolateur Mylar comme illustré sur la figure page 2. Glisser l isolateur en place, le bas derrière le rail sur lequel le couvercle de la source de courant repose. Les encoches de chaque bord de l isolateur doivent s aligner sur les encoches situées à l intérieur des panneaux d extrémité. Bobine d induction Rentrer cette extrémité derrière la bobine d induction. Rentrer cette extrémité sous le socle de la bobine d induction/des composants magnétiques. 10. En prenant soin de ne pas pincer les fils, faire coulisser le couvercle sur la source de courant pour le remettre en place. S assurer que les bords inférieurs sont dans les rails. Positionner la poignée sur les orifices de la partie supérieure du couvercle, puis utiliser les deux vis retirées auparavant pour fixer le couvercle. 11. Reconnecter l alimentation électrique et l alimentation en gaz. Powermax45 Bulletin de service sur le terrain 806070 Révision 1 a-3

Remplacement des isolateurs du Powermax45 Si vous devez déposer les vis de l interrupteur d alimentation 230 V CE/CSA Panneau d extrémité arrière Retirer ces quatre vis. 400 V CE/480 V CSA Retirer ces quatre vis. Retirer la vis de l interrupteur rotatif. O I Panneau d extrémité arrière a-4 Powermax45 Bulletin de service sur le terrain 806070 Révision 1