This Replacement Torch Adapter Kit is to be used to connect the Thermal Dynamics Plasma RPT Series Cutting Torch to the following equipment:



Documents pareils
Lavatory Faucet. Instruction Manual. Questions?

Paxton. ins Net2 desktop reader USB

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Le No.1 de l économie d énergie pour patinoires.

DOCUMENTATION - FRANCAIS... 2

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Guide d'installation rapide TFM-560X YO.13

Instructions Mozilla Thunderbird Page 1

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

DOCUMENTATION - FRANCAIS... 2

Notice Technique / Technical Manual

Free filter reminders! Sign up online at: santevia.com/filterease. need help? Contact Santevia!

SERVEUR DÉDIÉ DOCUMENTATION

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Grandes tendances et leurs impacts sur l acquisition de produits et services TI.

Folio Case User s Guide

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

Package Contents. System Requirements. Before You Begin

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Fabricant. 2 terminals

Application Form/ Formulaire de demande

Contrôle d'accès Access control. Notice technique / Technical Manual

IPSAS 32 «Service concession arrangements» (SCA) Marie-Pierre Cordier Baudouin Griton, IPSAS Board

Garage Door Monitor Model 829LM

Water Quality Information Management for Atlantic, Ontario, Manitoba, Pacific and Saskatchewan Regions

Gestion des prestations Volontaire

WEB page builder and server for SCADA applications usable from a WEB navigator

Credit Note and Debit Note Information (GST/ HST) Regulations

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

XtremWeb-HEP Interconnecting jobs over DG. Virtualization over DG. Oleg Lodygensky Laboratoire de l Accélérateur Linéaire

Règlement relatif à l examen fait conformément à la Déclaration canadienne des droits. Canadian Bill of Rights Examination Regulations CODIFICATION

Cedric Dumoulin (C) The Java EE 7 Tutorial

Frequently Asked Questions

CLIM/GTP/27/8 ANNEX III/ANNEXE III. Category 1 New indications/ 1 re catégorie Nouvelles indications

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

Practice Direction. Class Proceedings

FCM 2015 ANNUAL CONFERENCE AND TRADE SHOW Terms and Conditions for Delegates and Companions Shaw Convention Centre, Edmonton, AB June 5 8, 2015

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

Once the installation is complete, you can delete the temporary Zip files..

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

86 rue Julie, Ormstown, Quebec J0S 1K0

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Logitech Speaker System Z553 Setup Guide Guide d installation

Ships Elevator Regulations. Règlement sur les ascenseurs de navires CODIFICATION CONSOLIDATION. C.R.C., c C.R.C., ch. 1482

CONVENTION DE STAGE TYPE STANDART TRAINING CONTRACT

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

PRACTICE DIRECTION ON THE LENGTH OF BRIEFS AND MOTIONS ON APPEAL

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

12, Chemin de la Forge L Islet (Québec) G0R 1X0 CANADA

Trim Kit Installation Instruction

22/09/2014 sur la base de 55,03 euros par action

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN 61303:1997

INTERNATIONAL CONSULTANT & SUPPLIERS TO THE WINE & SPIRITS TRADE

APPENDIX 6 BONUS RING FORMAT

Restaurant Application Quick Reference Guide

Information Equipment

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

AVIS DE COURSE. Nom de la compétition : CHALLENGE FINN OUEST TOUR 3 Dates complètes : 14, 15 et 16 mai 2015 Lieu : Saint Pierre Quiberon

Exemple PLS avec SAS

PROJET DE LOI. An Act to Amend the Employment Standards Act. Loi modifiant la Loi sur les normes d emploi

Guide pour l Installation des Disques Durs SATA et Configuration RAID

Bill 69 Projet de loi 69

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Propriétés de la matière. Material properties. Sonde de pression Pressure probe. Ref : Français p 1. English p 3.

Form of Deeds Relating to Certain Successions of Cree and Naskapi Beneficiaries Regulations

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

DOCUMENTATION - FRANCAIS... 2

BILL 203 PROJET DE LOI 203

Multiple issuers. La cotation des actions ROBECO ci-dessous est suspendue sur EURONEXT PARIS dans les conditions suivantes :

France SMS+ MT Premium Description

Le Tour de Bretagne à la Voile est une épreuve de catégorie 3 des RSO. En cas de traduction de cet avis de course, le texte français prévaudra

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

Stainless Steel Solar Wall Light

ETABLISSEMENT D ENSEIGNEMENT OU ORGANISME DE FORMATION / UNIVERSITY OR COLLEGE:

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

THE LAW SOCIETY OF UPPER CANADA BY-LAW 19 [HANDLING OF MONEY AND OTHER PROPERTY] MOTION TO BE MOVED AT THE MEETING OF CONVOCATION ON JANUARY 24, 2002

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Contents Windows

MONTEGO 3 PERSON CUSHION GARDEN SWING WITH CANOPY ASSEMBLY INSTRUCTIONS ITEM# SC-177-2GS

GASKET FOR TONER COLLECTION BOTTLE

Lesson Plan Physical Descriptions. belle vieille grande petite grosse laide mignonne jolie. beau vieux grand petit gros laid mignon

POLICY: FREE MILK PROGRAM CODE: CS-4

Disclosure on Account Opening by Telephone Request (Trust and Loan Companies) Regulations

R.V. Table Mounting Instructions

ONTARIO Court File Number. Form 17E: Trial Management Conference Brief. Date of trial management conference. Name of party filing this brief

Name Use (Affiliates of Banks or Bank Holding Companies) Regulations

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

LE FORMAT DES RAPPORTS DU PERSONNEL DES COMMISSIONS DE DISTRICT D AMENAGEMENT FORMAT OF DISTRICT PLANNING COMMISSION STAFF REPORTS

Archived Content. Contenu archivé

Le Cloud Computing est-il l ennemi de la Sécurité?

Appointment or Deployment of Alternates Regulations. Règlement sur la nomination ou la mutation de remplaçants CONSOLIDATION CODIFICATION

Transcription:

Manual 0-2763 82 Benning Street, West Lebanon, NH 03784 USA (603) 298-5711 www.thermal-dynamics.com RPT Adapter Kit Catalog # 7-3430 Installation Instructions General Information This Replacement Torch Adapter Kit is to be used to connect the Thermal Dynamics Plasma RPT Series Cutting Torch to the following equipment: HYPERTHERM MAX 40 HF Start, MAX 70, MAX 80 and MAX 100 L-TEC PCS-40 MILLER SPECTRUM 700, 1000, 1250, PLUS POWCON STARCUT Parts Supplied The following parts are included in this kit: Control Connector Wire with Connectors & Spade Lugs - 1 ea Control Connector Wire with Connectors & Fastons - 2 ea Adapter Fitting - 1 ea Pilot Adapter Fitting - 1 ea Insulating Sleeve - 1 ea In-Line Splice - 1 ea Protective Boot - 1 ea Restrictor Pin Kit No. 8-3440 This kit includes parts that are not used in all applications. Read these directions carefully to determine whether all parts are needed. Installation on Power Supplies Without Quick Disconnect Install the Adapter Kit as follows: 1. Turn OFF the power supply. 2. Disconnect the main input power to the power supply. 3. Remove the existing torch from the power supply, removing covers as required. 4. Slide the Protective Boot, included in this kit, over the end of the Negative / Plasma Lead. 5. Place the Adapter Fitting provided into the Power Supply torch power cable fitting (-) and tighten securely. 6. Install the Pilot Adapter Fitting onto the Power Supply pilot connection. 7. Connect the pilot wire (+) from the replacement torch to the Power Supply Pilot Adapter Fitting. Secure the wire with the bolt and washers provided. 1998 Thermal Dynamics Corp., Printed in USA January 16, 2004 / 16 Janvier, 2004 1 Manual/Manuel 0-2763

8. Connect the Negative / Plasma Lead from the replacement torch to the Power Supply. Slide the protective boot over the lead connection. 9. Connect the Control Connector Plug, with two connectors, to the two mating connectors on the replacement torch leads, see. For Mechanized Systems refer to the Torch Control Cable Wiring Diagram Without Quick Disconnect on the last page of this Manual. Torch Lead Assembly Torch Control Connectors Control Connector Wires with Connectors Not Present in all Applications Spade Lugs Pilot Connector Pilot Adapter Fitting Pilot Lead Control Connector (-) Fitting Adapter Fitting Negative/Plasma Lead Art #A-03842 10. Connect the spade lugs of the Control Connector Wires to the Power Supply. 11. Reinstall any covers removed, see WARNING. WARNING Make sure that the Control Connector Plug wires DO NOT contact the Adapter Fitting after all leads are connected. 12. When using this kit to connect a Model SL60 or SL100 torch to any of the listed Miller Spectrum power supplies (ONLY): Install a restrictor pin in any starter cartridge to be used with a Model SL60 or SL100 torch, according to the separate instructions provided with restrictor pin kit No. 8-3440 included in this Adapter Kit. 13. Install the proper torch consumables for the Power Supply amperage. 14. Reconnect input power and turn ON the unit. 15. Set proper gas pressure or flow. 16. Test torch for proper operation. January 16, 2004 / 16 Janvier, 2004 2 Manual/Manuel 0-2763

Installation on Power Supplies With Quick Disconnect Install the Adapter Kit as follows: 1. Turn OFF the power supply. 2. Disconnect the main input power to the power supply. 3. Remove the existing torch from the power supply at the quick disconnect. 4. Disassemble the quick disconnect at the end of the original torch. Set the original torch aside. 5. Install the Adapter Fitting provided on to the quick disconnect power cable fitting (-) and tighten securely. 6. Install the Pilot Adapter Fitting onto the quick disconnect pilot Connection. 7. Connect the pilot wire (+) from the replacement torch to the Pilot Adapter Fitting. Secure with the nut and washer provided, see Note. The Pilot Lead may need to be shortened to allow the quick disconnect to be reassembled. 8. Slide the Protective Boot, included in this kit, over the end of the Negative / Plasma Lead. 9. Slide the Insulating Sleeve, provided, over the Negative / Plasma Lead and inside the Protective Boot. 10. Connect the Negative / Plasma Lead from the replacement torch to the Adapter Fitting installed on the quick disconnect. Slide the Insulating Sleeve over the lead connection, then slide the protective boot over the lead connection. 11. Connect the short Control Connector Wires, with two faston connectors, to the two mating connectors on the replacement torch leads. 12. Connect the fastons of the Control Connector Wires to the mating connectors on the quick disconnect. 13. Reassemble the quick disconnect, see WARNING, and connect to the Power Supply. WARNING Make sure that the Control Connector Plug wires DO NOT contact the Adapter Fitting after all leads are connected. 14. On mechanized systems connect the remote start command to the Power Supply, see. For Mechanized Systems refer to the Torch Control Cable Wiring Diagram with Quick Disconnect on the last page of this manual. 15. When using this kit to connect a Model SL60 or SL100 torch to any of the listed Miller Spectrum power supplies (ONLY): Install a restrictor pin in any starter cartridge to be used with a Model SL60 or SL100 torch, according to the separate instructions provided in restrictor pin kit No. 8-3440 included in this Adapter Kit. 16. Install the proper torch consumables for the Power Supply amperage. 17. Reconnect input power to the Power Supply and turn ON the unit. 18. Set proper gas pressure or flow. 19. Test torch for proper operation. January 16, 2004 / 16 Janvier, 2004 3 Manual/Manuel 0-2763

WARNING Replacing Original Machine Torch with TDC RPT Mechanized Torch Thermal Dynamics RPT mechanized torches have two control wires that are used for Parts-In-Place, PIP, only. Do not connect these PIP connections directly into any start input because when the torch parts are in place, the start signal will always be energized. If the torch parts are not in place but are subsequently installed with the start signal energized, the shield cup will complete the start circuit and the unit will immediately transfer a pilot arc. Torch Control Cable Wiring Diagram For Mechanized Systems Without Quick Disconnect Remote Start Command Parts-In-Place (PIP) Torch Control Connectors Torch Control Cable Control Connector Wires with Connectors Torch Lead Assembly Not Present in all Applications Control Connections (Start Signal) Art # A-03843 Torch Control Cable Wiring Diagram For Mechanized Systems With Quick Disconnect Part of Control Connector Wire with Connector Removed In-Line Splice Remote Start Command Torch Control Cable Part of Control Connector Wire with Connector Parts-In-Place (PIP) Torch Control Wires Control Connections (Start Signal) Quick Disconnect Assembly Existing Power Supply Wires For Start Signal Art # A-02846 Every effort has been made to provide complete and accurate information in this manual. However, the publisher does not assume and hereby disclaims any liability to any party for any loss or damage caused by errors or omissions in this manual, whether such errors result from negligence, accident or any other cause. January 16, 2004 / 16 Janvier, 2004 4 Manual/Manuel 0-2763

Manuel 0-2763 82 Benning Street, West Lebanon, NH 03784 USA (603) 298-5711 www.thermal-dynamics.com Kit D Adapteur De RPT Catalogue # 7-3430 Instructions D Installation Informations Générales Ce kit d adapteur de torche de rechange doit être employé pour connecter la torche de découpage de série du plasma RPT de Thermal Dynamics à l équipement suivant: HYPERTHERM MAX 40 Début d à haute fréquence, MAX 70, MAX 80 et MAX 100 L-TEC PCS-40 MILLER SPECTRUM 700, 1000, 1250, PLUS POWCON STARCUT Pièces Fournies Le kit inclut: Fil de connecteur de contrôle avec des connecteurs et des ergots de bêche Fil de connecteur de contrôle avec les connecteurs et le Fastons - 2 ea Raccord d adapteur Raccord d adapteur -pilote Douille isolante Épissure d In-Line Cache protectrice Kit No. 8-3440 de goupille de restricteur Ce kit inclut les pièces qui ne sont pas employées dans des applications d all. Lu ces directions soigneusement pour déterminer si les pièces d all sont nécessaires. Installation sur des Alimentations d énergie sans Quick Disconnect Installez le kit d adapteur par procédé suivant: 1. Spire OUTRE de l alimentation d énergie. 2. Débranchement la puissance d entrée principale à l alimentation d énergie. 3. Enlevez la torche existante de l alimentation d énergie, enlevant des couvertures comme requises. 4. Glissière la cache protectrice, incluse dans ce kit, au-dessus de la fin du fil négatif / plasma. 5. La place le raccord d adapteur fourni dans le raccord de cable électrique de torche d alimentation d énergie (-) et serrent solidement. 6. Installez le raccord d adapteur -pilote sur le raccordement de pilote d alimentation d énergie. 7. Connectez le fil pilote (+) de la torche de rechange au raccord d adapteur -pilote d alimentation d énergie. Bloqué le fil avec le boulon et les rondelles fournis. 8. Connectez le fil négatif / plasma de la torche de rechange à l alimentation d énergie. Glissière la cache protectrice au-dessus du raccordement de fil. January 16, 2004 / 16 Janvier, 2004 5 Manual/Manuel 0-2763

9. Connectez la fiche de connecteur de contrôle, à deux connecteurs, aux deux connecteurs joignants sur les fils de torche de rechange, voyez la. Pour les systèmes mécanisés référez-vous au diagramme de câblage de câble de commande de torche avec le Quick Disconnect à la dernière page de ce manuel. Fiche De Connecteur De Contrôle avec Des Connecteurs Connecteurs De Contrôle De Torche Assemblée De Fil De Torche Ergots De Bêche Pas Present dans Toutes les Applications Au Connecteur De Pilote D'Alimentation D'Énergie Raccord D'Adapteur-Pilote Fil Pilote Au Connecteur De Contrôle D'Alimentation D'Énergie Au Raccord D'Alimentation D'Énergie (-) Raccord D'Adapteur Fil De Négatif / Plasma Art #A-03842F 10. Connectez les ergots de bêche des fils de connecteur de contrôle à l alimentation d énergie. 11. Réinstallez toutes les couvertures enlevées, voyez l AVERTISSEMENT. AVERTISSEMENT Assurez-vous que les fils de fiche de connecteur de contrôle PAS contact le raccord d adapteur après que des fils d all soient connectés. 12. En utilisant ce kit pour relier une torche de modèle SL60 ou SL100 à quelles des alimentations d'énergie énumérées de Miller Spectrum (SEULEMENT): Installez une goupille de restricteur dans n importe quelle cartouche de démarreur à employer avec une torche SL60 ou SL100 de modèle, selon les instructions séparés fournis dans le No de kit de goupille de restricteur. 8-3440 inclus dans ce kit d adapteur 13 Installez les consommables appropriés de torche pour l amperage d alimentation d énergie. 14. Raccordez la puissance et la spire d entrée SUR l unité. 15. Pression ou flux approprié de gaz d ensemble. 16. Torche de test pour le fonctionnement approprié. January 16, 2004 / 16 Janvier, 2004 6 Manual/Manuel 0-2763

Installation sur des Alimentations d énergie avec le Quick Disconnect Installez le kit d adapteur par procédé suivant: Le fil pilote peut devoir se raccourcir pour permettre au rapide d'être rassemblé. 1. Spire OUTRE de l alimentation d énergie. 2. Débranchement la puissance d entrée principale à l alimentation d énergie. 3. Enlevez la torche existante de l alimentation d énergie au quick disconnect. 4. Démontez le quick disconnect à l extrémité de la torche originale. Ensemble la torche originale de côté. 5. Installez le raccord d adapteur fourni en circuit au raccord rapide de cable électrique (-) et serrez solidement. 6. Installez le raccord d adapteur -pilote sur le raccordement pilote rapide. 7. Connectez le fil pilote (+) de la torche de rechange au raccord d adapteur -pilote. Bloqué avec l écrou et la rondelle fournis, voir la note. Le fil pilote peut devoir se raccourcir pour permettre au rapide d'être rassemblé. 8. Glissière la cache protectrice, incluse dans ce kit, au-dessus de la fin du fil négatif / plasma. 9. Glissière la douille isolante, si, au-dessus de fil et de l intérieur négatifs / plasma la cache protectrice. 10. Connectez le fil négatif / plasma de la torche de rechange au raccord d adapteur installée sur le quick disconnect. Glissière la douille isolante au-dessus du raccordement de fil, puis glissière la cache protectrice audessus du raccordement de fil. 11. Connectez les fils courts de connecteur de contrôle, à deux connecteurs de faston, aux deux connecteurs joignants sur les fils de torche de rechange. 12. Connectez les fastons des fils de connecteur de contrôle aux connecteurs joignants sur le quick disconnect. 13. Rassemblez le quick disconnect, voyez l AVERTISSEMENT, et connectez à l alimentation d énergie. AVERTISSEMENT Assurez-vous que les fils de fiche de connecteur de contrôle PAS contact le raccord d adapteur après que des fils d all soient connectés. 14. Sur les systèmes mécanisés connectez la commande éloignée de début à l alimentation d énergie, voient la. Pour les systèmes mécanisés référez-vous au diagramme de câblage de câble de commande de torche avec le Quick Disconnect à la dernière page de ce manuel. 15. En utilisant ce kit pour relier une torche de modèle SL60 ou SL100 à quelles des alimentations d'énergie énumérées de Miller Spectrum (SEULEMENT): Installez une goupille de restricteur dans n importe quelle cartouche de démarreur à employer avec une torche SL60 ou SL100 de modèle, selon les instructions séparés fournis dans le No. 8-3440 de kit de goupille de restricteur inclus dans ce kit d adapteur 16. Installez les consommables appropriés de torche pour l amperage d alimentation d énergie. 17 Raccordez la puissance d entrée à l alimentation d énergie et la spire SUR l unité. January 16, 2004 / 16 Janvier, 2004 7 Manual/Manuel 0-2763

18. Pression ou flux approprié de gaz d ensemble. 19. Torche de test pour le fonctionnement approprié. AVERTISSEMENT Remplacement de la torche originale de machine par la torche mécanisée par RPT de TDC Les torches mécanisées par RPT de Thermal Dynamics ont deux fils de contrôle qui sont employés pour Parts-In- Place, PIP, seulement. Ne connectez ces raccordements de PIP directement dans aucune puissance d entrée de début parce que quand les pièces de torche sont en place, les always de volonté de signal de début activent. Si les pièces de torche ne sont pas en place mais sont plus tard installées avec le signal de début activé, la tasse de bouclier complet le circuit de début et l unité immédiatement transfert un arc pilote Diagramme De câblage De Câble De Commande De Torche Pour Les Systèmes Mécanisés Sans Quick Disconnect Commande Éloignée De Début Parts-In-Place (PIP) Connecteurs De Contrôle De Torche Câble De Commande De Torche Fils De Connecteur De Contrôle avec Des Connecteurs Assemblée De Fil De Torche Pas Presente dans Toutes les Applications Au Connecteur De Contrôle D'Alimentation D'Énergie (Signal De Début) Art # A-03843F Diagramme De câblage De Câble De Commande De Torche Pour Les Systèmes Mécanisés Avec Rapide Une Partie De Fil De Connecteur De Contrôle Le Connecteur Étant Coupé Épissure In-Line Commande Éloignée De Début Câble De Commande De Torche Une Partie De Fil De Connecteur De Contrôle avec Le Connecteur Parts-In-Place (PIP) Fils De Contrôle De Torche Au Connecteur De Contrôle D'Alimentation D'Énergie (Signal De Début) Assemblée Débranchement Rapide Fils Existants D'Alimentation D'Énergie Pour Le Signal De Début Art # A-02846F Tout effort a été fait de fournir des informations complètes et précises en ce manuel. Cependant, l éditeur n assume pas et ne dément par ceci aucune responsabilité à aucun usager pour aucune perte ou à dommages provoqués par des errors ou omissions en ce manuel, si un tel résultat d errors de la négligence, accident ou tout autre cause January 16, 2004 / 16 Janvier, 2004 8 Manual/Manuel 0-2763