DC Plug Connector Product Notes

Documents pareils
SunATM 4.0 Release Notes

Solaris Server Intranet Extension 1.0 Licensing Guide

Sun Java SystemWeb Server 7.0 Documentation Center

Sun Blade G2 RAID 0/1 Expansion Module Installation Guide

Solaris 8 Operating Environment Additions to sysidcfg

SunVTS Quick Reference Card

Planning Solstice Backup 6.1 (localisé)

SunScreen SKIP Open Issues and Late-breaking News, Release 1.1.1

Sun Fire V120 and Netra 120 Server

Paxton. ins Net2 desktop reader USB

SunVTS 7.0 Software Quick Reference

Sun Ultra 45 and Ultra 25 Workstations Getting Started Guide

Netra Proxy Cache Server Product Notes. A Sun Microsystems, Inc. Business 901 San Antonio Road Palo Alto,, CA

Sun StorEdge PCI Dual Ultra3 SCSI Host Adapter Release NotesM

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

Guide de démarrage du système modulaire Sun Blade 6000

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Sun StorageTek 2500 Series

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Archived Content. Contenu archivé

What s New. Sun ONE Application Server. Version 7, Enterprise Edition

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

SERVEUR DÉDIÉ DOCUMENTATION

Folio Case User s Guide

Configuring Databases Using Soft Links

Guide d'installation rapide TFM-560X YO.13

Fabricant. 2 terminals

DOCUMENTATION - FRANCAIS... 2

Sun Java Desktop System Management Tools

Package Contents. System Requirements. Before You Begin

DOCUMENTATION - FRANCAIS... 2

en SCÈNE RATIONAL Rational Démonstration SDP : automatisation de la chaîne de développement Samira BATAOUCHE sbataouche@fr.ibm.com

Notice Technique / Technical Manual

Contrôle d'accès Access control. Notice technique / Technical Manual

Sun Small Programmable Object Technology (Sun SPOT) Release Notes Release 3.0. Sun Labs October 2007

Garage Door Monitor Model 829LM

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

Instructions Mozilla Thunderbird Page 1

FÉDÉRATION INTERNATIONALE DE NATATION Diving

Application Form/ Formulaire de demande

How to Login to Career Page

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Gestion des prestations Volontaire

DOCUMENTATION MODULE BLOCKCATEGORIESCUSTOM Module crée par Prestacrea - Version : 2.0

Contents Windows

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Logitech Speaker System Z553 Setup Guide Guide d installation

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

Once the installation is complete, you can delete the temporary Zip files..

Tom Pertsekos. Sécurité applicative Web : gare aux fraudes et aux pirates!

Guide de récupération de Windows Server 2003 R2 pour serveurs Sun x64

INDIVIDUALS AND LEGAL ENTITIES: If the dividends have not been paid yet, you may be eligible for the simplified procedure.

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

Oracle FS Data Protection Manager. Release Notes. Part Number E Oracle FS Data Protection Manager release 3.5.

PARIS ROISSY CHARLES DE GAULLE

WEB page builder and server for SCADA applications usable from a WEB navigator

Subject to the terms of this Agreement, Adobe hereby grants you a nonexclusive,

Utiliser une WebCam. Micro-ordinateurs, informations, idées, trucs et astuces

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

APPENDIX 6 BONUS RING FORMAT

accidents and repairs:

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

OUVRIR UN COMPTE CLIENT PRIVÉ

SCHOLARSHIP ANSTO FRENCH EMBASSY (SAFE) PROGRAM APPLICATION FORM

Institut français des sciences et technologies des transports, de l aménagement

Conférence Bales II - Mauritanie. Patrick Le Nôtre. Directeur de la Stratégie - Secteur Finance Solutions risques et Réglementations

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

User guide Conference phone Konftel 100

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Sun Type 7 Keyboard and Mouse Installation Guide

Le No.1 de l économie d énergie pour patinoires.

ETABLISSEMENT D ENSEIGNEMENT OU ORGANISME DE FORMATION / UNIVERSITY OR COLLEGE:

Nouveautés printemps 2013

Tutoriel de formation SurveyMonkey

Formulaire d inscription (form also available in English) Mission commerciale en Floride. Coordonnées

Grandes tendances et leurs impacts sur l acquisition de produits et services TI.

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Le Cloud Computing est-il l ennemi de la Sécurité?

Critères à l attention des fabricants et des fournisseurs de biens ou de services : dispositifs mécaniques pour bingo

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

Cedric Dumoulin (C) The Java EE 7 Tutorial

Lavatory Faucet. Instruction Manual. Questions?

22/09/2014 sur la base de 55,03 euros par action

HUAWEI TECHNOLOGIES CO., LTD. channelroad. A better way. Together.

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

Immeuble indépendant 298 m2 sur 3 niveaux + terrasse 5bis rue de Beauce Paris

Ships Elevator Regulations. Règlement sur les ascenseurs de navires CODIFICATION CONSOLIDATION. C.R.C., c C.R.C., ch. 1482

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

Accompagner nos clients vers.cloud. Nicolas Luneau Business Development Manager Symantec.cloud

Railway Operating Certificate Regulations. Règlement sur les certificats d exploitation de chemin de fer CODIFICATION CONSOLIDATION

FCM 2015 ANNUAL CONFERENCE AND TRADE SHOW Terms and Conditions for Delegates and Companions Shaw Convention Centre, Edmonton, AB June 5 8, 2015

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN 61303:1997

Forthcoming Database

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Transcription:

DC Plug Connector Product Notes Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No. 806-0190-10 January 1999, Revision A Send comments about this document to: docfeedback@sun.com

Copyright 1999 Sun Microsystems, Inc., 901 San Antonio Road Palo Alto, CA 94303 USA. All rights reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party software, including font technology, is copyrighted and licensed from Sun suppliers. Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in the U.S. and other countries, exclusively licensed through X/Open Company, Ltd. Sun, Sun Microsystems, the Sun logo, AnswerBook, Netra, and Solaris are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the U.S. and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements. RESTRICTED RIGHTS: Use, duplication, or disclosure by the U.S. Government is subject to restrictions of FAR 52.227-14(g)(2)(6/87) and FAR 52.227-19(6/87), or DFAR 252.227-7015(b)(6/95) and DFAR 227.7202-3(a). DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON- INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. Copyright 1999 Sun Microsystems, Inc., 901 San Antonio Road Palo Alto, CA 94303 Etats-Unis. Tous droits réservés. Ce produit ou document est protégé par un copyright et distribué avec des licences qui en restreignent l utilisation, la copie, la distribution, et la décompilation. Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans l autorisation préalable et écrite de Sun et de ses bailleurs de licence, s il y en a. Le logiciel détenu par des tiers, et qui comprend la technologie relative aux polices de caractères, est protégé par un copyright et licencié par des fournisseurs de Sun. Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l Université de Californie. UNIX est une marque déposée aux Etats-Unis et dans d autres pays et licenciée exclusivement par X/Open Company, Ltd. Sun, Sun Microsystems, le logo Sun, AnswerBook, Netra, et Solaris sont des marques de fabrique ou des marques déposées, ou marques de service, de Sun Microsystems, Inc. aux Etats-Unis et dans d autres pays. Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc. aux Etats-Unis et dans d autres pays. Les produits portant les marques SPARC sont basés sur une architecture développée par Sun Microsystems, Inc. L interface d utilisation graphique OPEN LOOK et Sun a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun reconnaît les efforts de pionniers de Xerox pour la recherche et le développement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique. Sun détient une licence non exclusive de Xerox sur l interface d utilisation graphique Xerox, cette licence couvrant également les licenciés de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences écrites de Sun. CETTE PUBLICATION EST FOURNIE "EN L ETAT" ET AUCUNE GARANTIE, EXPRESSE OU IMPLICITE, N EST ACCORDEE, Y COMPRIS DES GARANTIES CONCERNANT LA VALEUR MARCHANDE, L APTITUDE DE LA PUBLICATION A REPONDRE A UNE UTILISATION PARTICULIERE, OU LE FAIT QU ELLE NE SOIT PAS CONTREFAISANTE DE PRODUIT DE TIERS. CE DENI DE GARANTIE NE S APPLIQUERAIT PAS, DANS LA MESURE OU IL SERAIT TENU JURIDIQUEMENT NUL ET NON AVENU. Please Recycle

DC Plug Connector Product Notes Four plug connectors are provided to form input cables for connecting to DC sources with a 20-amp breaker for each source (two plug connectors for input cables and two spare plug connectors). Following are the instructions for assembling the DC input power cables using the DC plug connectors. DC Source Site Requirements TABLE 1 DC Power Requirements 1 Electrical Element Voltage Max. Operating current Max. Input Surge current Requirement -48 VDC 11 amps 22 amps peaks 1. The DC power supply range is -40 VDC to -75 VDC, 13 amps max. operating current. Electrically isolated from any AC source Reliably connected to earth (that is, the battery room positive bus is connected to the grounding electrode) Capable of providing up to 600 watts of continuous power per feed pair Note The DC version of the Netra st system must be installed in a restricted access location. Per the intent of the National Electrical Code, a restricted access location is an area intended for qualified or trained personnel only, and has access controlled by some sort of locking mechanism, such as a key lock or an access card system. 1

Overcurrent Protection Requirements Overcurrent protection devices must be provided as part of each equipment rack. Circuit breakers must be located between the DC power source and the Netra st system (two 20-amp double-pole fast trip DC-rated circuit breakers for each power supply). Note Overcurrent protection devices must meet applicable national and local electrical safety codes and be approved for the intended application. DC Supply and Ground Conductor The requirements are: Suitable conductor material: copper only Power supply connections through the input connector: 12 AWG (between the Netra st and the circuit breaker) 1. There are three conductors: -48V -48V Return Ground connection to the power supply System ground conductor: 8 AWG (to be connected to the system chassis) Cable insulation rating: minimum of 75 C, low smoke fume (LSF), flame retardant Cable type to be one of the following: UL style 1028 or other UL 1581(VW-1) compliant equivalent IEEE 383 compliant IEEE 1202-1991 compliant Branch circuit cable insulation color: per applicable national electrical codes Grounding cable insulation color: green/yellow Required Connection Materials DC branch circuits: Four POWER-COMBICON plug connectors with screw flanges from Phoenix Contact are supplied in the ship kit with each system for proper connection to the -48V DC power source (two plug connectors for input cables and two spare plug connectors). 1. The input connectors are provided with every Netra st system; however, the input conductors are not provided with the system. 2 DC Plug Connector Product Notes January 1999

Feed Through Header on the DC Power Supply FIGURE 1 shows the feed through header on the DC power supply on the Netra st system. RTN (-48V) (Ground) (-48V Return) FIGURE 1 Feed Through Header on the DC Power Supply To Assemble the DC Input Power Cable 1. Turn off power to the DC power source through the circuit breakers. Caution Do not proceed with these instructions until you have turned off the power to the DC power source through the circuit breakers. 2. Get two DC plug connectors from the ship kit (FIGURE 2). Top of connector To -48V pin To Ground pin To -48V Return pin FIGURE 2 DC Plug Connector DC Plug Connector Product Notes 3

3. Locate the three wires coming from the DC power source that will be used in the connection to the Netra st system: -48V Ground -48V Return 4. Strip.27 inches of insulation from each of the wires coming from the DC power source (FIGURE 3). Do not strip more than.27 inches from each wire. Doing so will leave uninsulated wire exposed from the DC plug after the assembly is complete. 0.27 FIGURE 3 Striping the Insulation from the Cable 5. Feed the exposed section of each wire into the appropriate hole in the DC plug connector (FIGURE 4). To -48V pin Black (from -48V source) Three captive screws at bottom of connector Green/yellow (from earth ground) Red (from -48V Return source) To Ground pin To -48V Return pin FIGURE 4 Assembling the DC Power Cable 6. Use a screwdriver to tighten the three captive screws at the bottom of the DC plug connector to secure each wire in place (FIGURE 5). The tightening torque must be 5-7 lb-in. 4 DC Plug Connector Product Notes January 1999

Red (from -48V Return source) Green/yellow (from earth ground) To -48V Return pin To Ground pin To -48V pin Black (from -48V source) FIGURE 5 Tightening the Captive Screws at Bottom of DC Connector 7. Repeat Step 3 through Step 6 to create a second DC input power cable using the second power connector. Note that you will want to have the first set of wires connected to DC power source A and the second set of wires connected to DC power source B. What s Next The DC input power cables for your Netra st system are now completely assembled. FIGURE 6 shows how the DC input power cable will be connected to the DC feed through header on your Netra st system. (-48V DC) (Ground) RTN (-48V Return) FIGURE 6 Black (to -48V pin) Green/yellow (to ground pin) Red (to RTN pin) Connecting the DC Power Cable to the DC Feed Through Header Follow the instructions in the Netra st A1000 and Netra st D1000 Installation and Maintenance Manual for the full installation instructions for your Netra st system. DC Plug Connector Product Notes 5

6 DC Plug Connector Product Notes January 1999