Powermax65 Powermax85 Powermax105 Powermax125 RS-485 Serial Interface Port Port d interface en série RS-485

Documents pareils
ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Folio Case User s Guide

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Lavatory Faucet. Instruction Manual. Questions?

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Logitech Speaker System Z553 Setup Guide Guide d installation

Instructions Mozilla Thunderbird Page 1

Contents Windows

R.V. Table Mounting Instructions

ENGLISH 4 FRANÇAIS 6 ESPAÑOL 8

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

Notice Technique / Technical Manual

Monitor LRD. Table des matières

Trim Kit Installation Instruction

Package Contents. System Requirements. Before You Begin

Fabricant. 2 terminals

lundi 3 août 2009 Choose your language What is Document Connection for Mac? Communautés Numériques L informatique à la portée du Grand Public

Paxton. ins Net2 desktop reader USB

SYSTÈME JETS D AIR WISH WISH AIR JETS SYSTEM Système de massage à jets d air pour bains en polymère - Air jet massage system for polymer bathtubs

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Le No.1 de l économie d énergie pour patinoires.

Embases pour raccordement G1/8 - G1/4

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

PARIS ROISSY CHARLES DE GAULLE

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

Sécurité relative aux sièges auto et aux rehausseurs

Guide d'installation rapide TFM-560X YO.13

SYSTÈME DE GAINES À SPIRALE ET RACCORDS TOURNANTS

Contrôle d'accès Access control. Notice technique / Technical Manual

DOCUMENTATION - FRANCAIS... 2

Warning: Failure to follow these warnings could result in property damage, or personal injury.

PRESENTATION REMOTE TÉLÉCOMMANDE DE PRÉSENTATION. User Guide Manuel de l utilisateur

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

Logitech Wireless Performance Combo MX800 Setup Guide Guide d installation

How to Login to Career Page

Sun StorageTek 2500 Series

en SCÈNE RATIONAL Rational Démonstration SDP : automatisation de la chaîne de développement Samira BATAOUCHE sbataouche@fr.ibm.com

GASKET FOR TONER COLLECTION BOTTLE

MONTEGO 3 PERSON CUSHION GARDEN SWING WITH CANOPY ASSEMBLY INSTRUCTIONS ITEM# SC-177-2GS

Table des matières QUINCAILLERIE FONCTIONNEL FUNCTIONAL HARDWARE. Clé H1 Serrure et pêne H2. Serrure à levier H4

SERVEUR DÉDIÉ DOCUMENTATION

POLICY: FREE MILK PROGRAM CODE: CS-4

Editing and managing Systems engineering processes at Snecma

WEB page builder and server for SCADA applications usable from a WEB navigator

Propriétés de la matière. Material properties. Sonde de pression Pressure probe. Ref : Français p 1. English p 3.

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

22/09/2014 sur la base de 55,03 euros par action

THE EVOLUTION OF CONTENT CONSUMPTION ON MOBILE AND TABLETS

DOCUMENTATION MODULE BLOCKCATEGORIESCUSTOM Module crée par Prestacrea - Version : 2.0

PAR_ _09543_EUR DATE: 17/12/2014. Suite à l'avis PAR_ _08654_EUR

DOCUMENTATION - FRANCAIS... 2

Start Here Point de départ

Tutoriel de formation SurveyMonkey

Garage Door Monitor Model 829LM

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Once the installation is complete, you can delete the temporary Zip files..

Quick start guide. HTL1170B

Now enhanced with powerful workplace solutions Maintenant amélioré, diet+ vous offre de puissantes solutions novatrices pour le milieu de travail

Z-Axis Compliance Device Compliance en z

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

PACKZ System Requirements. Version: Version: Copyright 2015, PACKZ Software GmbH. 1

Les Portfolios et Moodle Petit inventaire

Spécial Catégorie 6 Patch Cords

Stérilisation / Sterilization

GAME CONTENTS CONTENU DU JEU OBJECT OF THE GAME BUT DU JEU

Vanilla : Virtual Box

Utiliser un proxy sous linux

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

valentin labelstar office Made-to-measure label design. Conception des étiquettes sur mesure. Quality. Tradition. Innovation DRUCKSYSTEME

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Interest Rate for Customs Purposes Regulations. Règlement sur le taux d intérêt aux fins des douanes CONSOLIDATION CODIFICATION

Wobe.

Exercices sur SQL server 2000

Cedric Dumoulin (C) The Java EE 7 Tutorial

ADMINISTRATION DE ADOBE LIVECYCLE MOSAIC 9.5

Panneau d alimentation de Store Cellulaire

Maximum Capacity / Capacité maximal: 10 kg/min


MANUEL MARKETING ET SURVIE PDF

Comment Accéder à des Bases de Données MySQL avec Windows lorqu'elles sont sur un Serveur Linux

Multiple issuers. La cotation des actions ROBECO ci-dessous est suspendue sur EURONEXT PARIS dans les conditions suivantes :

HUAWEI TECHNOLOGIES CO., LTD. channelroad. A better way. Together.

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Nouveautés printemps 2013

CEST POUR MIEUX PLACER MES PDF

Stainless Steel Solar Wall Light

Insérer des images dans Base

Contrôle électronique pour chambres froides

Start Here Point de départ Epson Stylus

MODE D EMPLOI USER MANUAL

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

L'Offre sera ouverte pendant 18 jours de bourse, à un prix par action de 152,30 EUR. BPCE International et Outre-Mer

Comment Créer une Base de Données Ab Initio

Transcription:

Powermax65 Powermax85 Powermax105 Powermax15 RS-485 Serial Interface Port Port d interface en série RS-485 Field Service Bulletin Bulletin de service sur le terrain 806710 Revision December 013 Révision Décembre 013

RS-485 Serial Interface Port WARNING ELECTRIC SHOCK CAN KILL Disconnect electrical power before performing any maintenance. See the Safety and Compliance Manual included with your system for more safety precautions. Introduction Purpose This Field Service Bulletin describes the procedure for installing an RS-485 serial interface port. Detailed information regarding the pin out of the RS-485 connector can be found in the operator manual. Powermax105/15 systems: Complete instructions for installing this repair kit are included in the Service Manual. To download the Service Manual, go to www.hypertherm.com and click the Downloads library link. Powermax105 Service Manual (807580) Powermax15 Service Manual (808070) Materials and tools Assorted Phillips and TORX screwdrivers Field Service Bulletin 1

RS-485 Serial Interface Port Kit 8539 contents Part number Description Quantity 075418 Screws 075534 Screws 108879* Terminal: Plug 4-1 AWG 5-position 50V 1A screw connector block 1 141109 RS-485 board 1 931 RS-485 wire group (two cables) 1 075541** M4 kepnut 1 * This is the external connector which mates with the power supply RS-485 connector. It is provided as an option for interfacing between the power supply and the customer s CNC. ** Only used on Powermax105/15 systems. 931 (three cables) 141109 108879* 075534 () 075418 () 075541 Field Service Bulletin

RS-485 Serial Interface Port Remove the power supply cover and component barrier 1. Turn OFF the power, disconnect the power cord, and disconnect the gas supply.. Remove the 8 small screws () from the power supply cover. 3. Remove the 8 large screws (1) from the power supply cover. 4. Lift the cover (3) off the power supply. 1 1 3 1 1 1 5. Remove the component barrier from the power-board side of the power supply. The component barrier is flexible and can be bent slightly for removal. Field Service Bulletin 3

RS-485 Serial Interface Port Access the RS-485 connector mounting hole 1. Remove the screw directly above the air inlet fitting, on the rear of the power supply. Screw. Peel the right hand edge of the silkscreen label toward the perforated line in the center of the label. 4 Field Service Bulletin

RS-485 Serial Interface Port 3. Apply pressure to the left half of the label while tearing the right half of the label on the perforated line. Discard the right half of the label. 4. Install the screw removed in step one. Tighten the screw to 17.3 kg cm (15 in-lbs). Screw RS-485 Connector mounting hole Field Service Bulletin 5

RS-485 Serial Interface Port Install the RS-485 serial interface port upgrade kit Caution: Static electricity can damage circuit boards. Use proper precautions when handling printed circuit boards. Store PC boards in anti-static containers. Wear a grounded wrist strap when handling PC boards. 1. Secure the RS-485 board to the plastic mounting posts, located on the center panel directly behind the DSP board, using screws. Tighten the screws to 11.5 kg cm (10 in-lbs). Mounting screws RS-485 Board DSP Board 6 Field Service Bulletin

RS-485 Serial Interface Port. Secure the ring terminal on the ground wire (green with yellow stripe) to the center panel, using the screw from the center panel bracket. Center panel bracket and screw Lower right bushing 3. Firmly push the ground wire connector through the lower right bushing located in the center panel and attach it at the bottom left corner of the RS-485 board. RS-485 Board Ground wire connector 4. Install the long cable by routing the small connector through the RS-485 connector mounting hole in the rear panel. Follow the two existing gray cables and firmly push the small connector through the lower right bushing located in the center panel. 5. Plug the cable connector onto the J1 connector of the RS-485 board. J1 Connector Field Service Bulletin 7

RS-485 Serial Interface Port 6. Fasten the RS-485 connector in the mounting hole of the rear panel, with the red wire on top, using screws. Tighten the screws to 11.5 kg cm (10 in-lbs). Connector mounting screws 7. Install the short cable by pushing the connector with the larger white strain relief cover onto the J connector of the RS-485 board. Push the other connector onto the J7 connector of the DSP board. RS-485 Board J Connector J7 Connector DSP Board 8 Field Service Bulletin

RS-485 Serial Interface Port Replace the component barrier 1. Carefully push in the sides (1) of the component barrier so that the barrier bends out slightly at the top and bottom ().. Slide the sides of the component barrier behind the power supply frame (3). Be careful to get the barrier between the frame and the power wires on the right side of the power board (4). 3. Gently bend the top of the barrier at the perforation so that the top bends over the top of the power supply. 4. Slide the barrier down so that the bottom edge fits inside the power supply frame (5). 4 3 3 1 1 3 3 5 Field Service Bulletin 9

RS-485 Serial Interface Port Replace the power supply cover 1. Place the cover (3) over the power supply. Be careful not to pinch any wires.. Install the 8 small screws () into the power supply cover. Tighten the screws to 17.3 kg cm (15 in-lbs). 3. Install the 8 large screws (1) into the power supply cover. Tighten the screws to 17.3 kg cm (15 in-lbs). 1 1 Front of power supply 3 1 1 1 10 Field Service Bulletin

Port d interface en série RS-485 AVERTISSEMENT UN CHOC ÉLECTRIQUE PEUT ÊTRE MORTEL Débrancher l alimentation électrique avant tout entretien. Se reporter au Manuel de sécurité et de conformité compris avec votre système pour d autres mesures de sécurité. Introduction Objet Le présent bulletin de service sur le terrain décrit la procédure d installation d un port d interface en série RS-485. Consulter le manuel de l opérateur pour de plus amples renseignements concernant le contact du connecteur RS-485. Systèmes Powermax105/15 : Les instructions complètes pour l installation de ce kit de réparation sont incluses dans le Manuel de service. Pour télécharger le Manuel de service, se rendre sur www.hypertherm.com et cliquer sur le lien «Bibliothèque des téléchargements». Manuel de service du Powermax105 (807580) Manuel de service du Powermax15 (808070) Matériel et outils requis Tournevis Phillips et TORX divers Bulletin de service sur le terrain a-1

Port d interface en série RS-485 Contenu du kit 8539 Numéro de Description Quantité référence 075418 Vis 075534 Vis 108879* Borne : Fiche 4-1 AWG, bloc connecteur à visser de 50 V, 1 A à cinq positions 1 141109 Circuit RS-485 1 931 Groupe de fils RS-485 (deux câbles) 1 075541** Écrou hexagonal M4 1 * Ceci est le connecteur externe correspondant au connecteur RS-485 de la source de courant. Il s agit d une alternative d interface entre la source de courant et la CNC du client. ** Utilisé uniquement sur les systèmes Powermax105/15. 931 (trois câbles) 141109 108879* 075534 () 075418 () 075541 a- Bulletin de service sur le terrain

Port d interface en série RS-485 Retrait du couvercle de la source de courant et de la barrière de composant 1. Couper l alimentation (OFF), débrancher le cordon d alimentation et débrancher l alimentation en gaz.. Déposer les 8 petites vis () du couvercle de la source de courant. 3. Déposer les 8 grandes vis (1) du couvercle de la source de courant. 4. Retirer le couvercle (3) de la source de courant. 1 1 3 1 1 1 5. Retirer la barrière du côté du panneau d alimentation de la source de courant. Cette barrière est flexible et peut être pliée légèrement pour être enlevée. Bulletin de service sur le terrain a-3

Port d interface en série RS-485 Accès à l orifice de montage du connecteur RS-485 1. Retirer la vis directement au-dessus du raccord de l entrée d air à l arrière de la source de courant. Vis. Décoller le coin droit de l étiquette sérigraphiée jusqu à la ligne perforée au centre de celle-ci. a-4 Bulletin de service sur le terrain

Port d interface en série RS-485 3. Appliquer une pression sur la moitié gauche de l étiquette tout en déchirant le coté droit le long de la ligne perforée. Jeter la moitié droite de l étiquette. 4. Revisser la vis déposée à la première étape. Serrer la vis à un couple de 17,3 kg cm. Vis Orifice de montage pour le connecteur RS 485 Bulletin de service sur le terrain a-5

Port d interface en série RS-485 Installation de l ensemble de pièces de mise à niveau du port d interface en série RS-485 Attention : L électricité statique peut endommager les cartes de circuits imprimés. Les précautions qui s imposent doivent être respectées lors de la manipulation des cartes de circuits imprimés. Les cartes de circuits imprimés doivent être stockées dans des contenants antistatiques. L utilisateur doit porter un bracelet antistatique lors de la manipulation des cartes de circuits imprimés. 1. À l aide de vis, fixer solidement le circuit RS-485 aux bornes de montage en plastique situées au centre du panneau, directement derrière le circuit imprimé du processeur de signal numérique. Serrer les vis à un couple de 11,5 kg cm. Vis de montage Circuit RS-485 Circuit imprimé du processeur de signal numérique a-6 Bulletin de service sur le terrain

Port d interface en série RS-485. Fixer la cosse ronde sur le câble de terre (vert avec lignes jaunes) au panneau central, en utilisant la vis du support du panneau central. Support et vis du panneau central Bague inférieure droite 3. Enfoncer fermement le connecteur du câble de terre dans la bague inférieure droite du panneau central et le fixer au coin inférieur gauche du panneau RS-485. Circuit RS-485 Connecteur du câble de terre 4. Installer le long câble en enfilant le petit connecteur dans l orifice de montage du connecteur RS-485 situé dans le panneau arrière. Suivre le parcours des deux câbles gris existants et enfoncer fermement le petit connecteur dans la bague inférieure droite du panneau central. 5. Brancher le connecteur du câble dans le connecteur J1 du circuit RS-485. Connecteur J1 Bulletin de service sur le terrain a-7

Port d interface en série RS-485 6. À l aide des vis, attacher le connecteur RS-485 dans l orifice de montage du panneau arrière avec le fil rouge sur le dessus. Serrer les vis à un couple de 11,5 kg cm. Vis de montage du connecteur 7. Installer le câble court en enfonçant le connecteur avec le grand couvercle blanc du serre-câble sur le connecteur J du circuit RS-485. Enfoncer l autre connecteur dans le connecteur J7 du circuit imprimé du processeur de signal numérique. Circuit RS-485 Connecteur J Connecteur J7 DS Circuit imprimé du processeur de signal numérique a-8 Bulletin de service sur le terrain

Port d interface en série RS-485 Replacer la barrière de composant 1. Enfoncer soigneusement les côtés (1) de la barrière de composant de façon à ce qu elle fléchisse légèrement à ses parties supérieure et inférieure ().. Glisser les côtés de la barrière de composant derrière le cadre de la source de courant (3). Faire attention de bien placer la barrière entre le cadre et les fils d alimentation du côté droit du circuit imprimé (4). 3. Plier délicatement le haut de la barrière au niveau de la perforation, de façon à ce que le haut se replie au-dessus de la partie supérieure de la source de courant. 4. Glisser la barrière vers le bas de façon à ce que le rebord inférieur entre dans le cadre de la source de courant (5). 4 3 3 1 1 3 3 5 Bulletin de service sur le terrain a-9

Port d interface en série RS-485 Remise en place du couvercle de la source de courant 1. Placer le couvercle (3) sur la source de courant. S assurer de ne pincer aucun fil.. Insérer les 8 petites vis () dans le couvercle de la source de courant. Serrer les vis à un couple de 17,3 kg cm. 3. Insérer les 8 grosses vis (1) dans le couvercle de la source de courant. Serrer les vis à un couple de 17,3 kg cm. 1 1 Avant de la source de courant 3 1 1 1 a-10 Bulletin de service sur le terrain

013 Hypertherm Inc. All Rights Reserved Tous droits réservés Hypertherm and Powermax are trademarks of Hypertherm Inc. and may be registered in the United States and/or other countries. Hypertherm et Powermax sont des marques d Hypertherm Inc. qui peuvent être déposées aux États-Unis et/ou dans d autres pays. Hypertherm, Inc. Hanover, NH 03755 USA 603-643-3441 Tel Hypertherm Europe B.V. 4704 SE Roosendaal, Nederland 31 165 596907 Tel Hypertherm (Shanghai) Trading Co., Ltd. PR China 0031 86-1-60740003 Tel Hypertherm (S) Pte Ltd. Singapore 349567 65 6 841 489 Tel Hypertherm (India) Thermal Cutting Pvt. Ltd. Chennai, Tamil Nadu 91 0 44 834 5361 Tel Hypertherm Brasil Ltda. Guarulhos, SP - Brasil 55 11 409 636 Tel Hypertherm México, S.A. de C.V. México, D.F. 5 55 5681 8109 Tel Hypertherm Korea Branch Korea, 61-889 8 51 747 0358 Tel www.hypertherm.com