User's Manual. Digital Sound Level Meter. Model 407768



Documents pareils
USER GUIDE. Video Borescope. Model BR100

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

Lavatory Faucet. Instruction Manual. Questions?

Paxton. ins Net2 desktop reader USB

Package Contents. System Requirements. Before You Begin

Notice Technique / Technical Manual

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Instructions Mozilla Thunderbird Page 1

worldwide limited warranty and technical support

Guide d'installation rapide TFM-560X YO.13

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Folio Case User s Guide

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Contents Windows

PRESENTATION REMOTE TÉLÉCOMMANDE DE PRÉSENTATION. User Guide Manuel de l utilisateur

Quick start guide. HTL1170B

Le No.1 de l économie d énergie pour patinoires.

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Warning: Failure to follow these warnings could result in property damage, or personal injury.

J. Nexera Distribution assembly instructions consignes d assemblage instrucciones de ensamblaje

Garage Door Monitor Model 829LM

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

PAR RINOX INC BY RINOX INC PROGRAMME D INSTALLATEUR INSTALLER PROGRAM

AUTO ER ADAPT ER SPECIAL USE WARNING

Fabricant. 2 terminals

Practice Direction. Class Proceedings

Contrôle d'accès Access control. Notice technique / Technical Manual

DOCUMENTATION MODULE BLOCKCATEGORIESCUSTOM Module crée par Prestacrea - Version : 2.0

Owner's Manual RSB-1410

WEB page builder and server for SCADA applications usable from a WEB navigator

DOCUMENTATION - FRANCAIS... 2

Mesure chimique Conductimétrie. Chemical measurement Conductimetry. Conductimètre CTM Initio. Initio CTM conductimeter. Ref :

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

How to Login to Career Page

POLICY: FREE MILK PROGRAM CODE: CS-4

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

LG Electronics, Inc. Display Limited Warranty - USA

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

SERVEUR DÉDIÉ DOCUMENTATION

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

DOCUMENTATION - FRANCAIS... 2

SERIE TS-770 SYSTEME CONFERENCE

Principe de TrueCrypt. Créer un volume pour TrueCrypt

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

AUDIT COMMITTEE: TERMS OF REFERENCE

Logitech Speaker System Z553 Setup Guide Guide d installation

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Archived Content. Contenu archivé

Application Form/ Formulaire de demande

USB 598. Quick Start Guide (Windows) Guide de démarrage rapide (Windows) USB Modem. Modem USB.

RAPID Prenez le contrôle sur vos données

Nouveautés printemps 2013

PIB : Définition : mesure de l activité économique réalisée à l échelle d une nation sur une période donnée.

Quick Installation Guide TEW-AO12O

Le Cloud Computing est-il l ennemi de la Sécurité?

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Exercices sur SQL server 2000

Quick Installation Guide TBW-106UB H/W: V1

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

Trim Kit Installation Instruction

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Master4Light. Caractérisation Optique et Electrique des Sources Lumineuses. Equipement 2-en-1 : source de courant et spectrophotomètre

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

Spécial Catégorie 6 Patch Cords

Contrôle d accès Access control MOD-TCPIP-AI. Notice technique / Technical Manual

Guide d installation Deco Drain inc. DD200

Editing and managing Systems engineering processes at Snecma

Instruction Manual. HS-636-4GBBK MP3 Player

Monitor LRD. Table des matières

Once the installation is complete, you can delete the temporary Zip files..

THE EVOLUTION OF CONTENT CONSUMPTION ON MOBILE AND TABLETS

If the corporation is or intends to become a registered charity as defined in the Income Tax Act, a copy of these documents must be sent to:

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

DOCUMENTATION - FRANCAIS... 2

Gestion des prestations Volontaire

KitchenAid Blender_ War_r_anty for_ the 50 United States, the Distr_ict of Columbia, Puer_to Rico, and Canada

PROJET DE LOI. An Act to Amend the Employment Standards Act. Loi modifiant la Loi sur les normes d emploi

Quick Setup Guide Guide de configuration rapide. Tablet Device SGPT12 Series Tablette électronique Série SGPT12

PARIS ROISSY CHARLES DE GAULLE

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

Academic Project. B2- Web Development. Resit Project. Version 1.0 Last update: 24/05/2013 Use: Students Author: Samuel CUELLA

AND / ET USER GUIDE UK HARDWIRED CONTROL PANEL UK GUIDE UTILISATEUR CENTRALE D ALARME FILAIRE F

Quick Installation Guide TV-IP400 TV-IP400W

APPENDIX 6 BONUS RING FORMAT

Quick Installation Guide TW100-BRV304

PVCHECK Rel /11/12

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

ENGLISH 4 FRANÇAIS 6 ESPAÑOL 8

Discours du Ministre Tassarajen Pillay Chedumbrum. Ministre des Technologies de l'information et de la Communication (TIC) Worshop on Dot.

Stratégie DataCenters Société Générale Enjeux, objectifs et rôle d un partenaire comme Data4

Frequently Asked Questions

Guide d'installation rapide TK-803R TK-1603R

PRACTICE DIRECTION ON THE LENGTH OF BRIEFS AND MOTIONS ON APPEAL

Transcription:

User's Manual Digital Sound Level Meter Model 407768

Introduction Congratulations on your purchase of the Extech 407768 Sound Level Meter. This Auto Range Sound Level Meter meets ANSI and IEC Type II accuracy standards. Professional features include programmable Frequency Weighting and Time Response, Min/Max Memory, Max Hold, Analog output, and RS-232 PC Interface. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Specifications Display Frequency bandwidth Microphone Output terminals Measurement ranges Frequency weighting 5 Digit LCD with overload, low battery and multifunction indication 31.5 Hz to 8 KHz 0.5 Electret Condensor Microphone Optically isolated RS-232 port and AC output Auto Range: 30 to 130dB Manual Ranges: 30 to 80dB, 50 to 100dB, 80 to 130dB A and C (Programmable) Applicable standards ANSI S1.4:1983 Type 2, / IEC 61672 Class 2, Resolution Maximum/Minimum record Data Hold Max Hold Response time AC Analog output Power 0.1dB Highest and lowest readings are stored for later recall Displayed reading is held when HOLD key is pressed Highest reading displayed only Fast: 125ms / Slow:1s (Programmable) 0.5VAC rms full scale (600 output impedance) 9V Battery; Consumption: 6mADC approx. Operating temperature 32 to 122 o F (0 to 50 o C) Operating humidity Less than 80% RH Dimensions / Weight 10.6 x 2.7 x 1.1" / 0.63 lbs. (268 x 68 x 29mm / 285g) Meter Description 1. Microphone 2. LCD Display 3. Power, Hold, and Min/Max buttons 4. Max, Weighting, Response Time, & Range buttons 5. AC output jack 6. Calibration potentiometer 7. RS-232 PC interface jack 8. Battery compartment, tilt stand, and tripod mount on rear 1 2 3 4 5 6 7 8 2

Sound Level Meter Operation Meter Power 1. The meter is powered by a 9V battery. The battery compartment is located on the rear of the meter and the compartment cover is secured by one Phillips screw. When the battery icon appears on the top left corner of the meter's display, replace the battery. 2. Press the POWER button to turn the meter on. Note that the Meter is equipped with an Auto Power Off feature that shuts the meter off after 10 minutes. To defeat Auto Power Off, put the meter in Record mode by pressing the REC MAX/MIN button. 3. Press the POWER button to turn the meter off. Default Configuration 1. The meter's default configuration is as follows: Auto Range, 'A' Frequency Weighting, and 'FAST' Response Time 2. The lower portion of the LCD will reflect the meter's configuration, i.e., 'A', 'Fast', 'Auto'. Measurement Considerations 1. Use a windscreen (not included) to cover the microphone in windy conditions. 2. Calibrate the meter often, especially if the meter has been idle for a long period of time. 3. Do not store/operate the meter in areas of high temperature or humidity. 4. Keep the meter and the microphone dry. 5. Avoid severe vibration when using the meter. 6. Remove the battery when the meter will be stored for long periods of time. Frequency Weighting Change the Frequency Weighting by pressing the 'A/C' button. The 'A' or 'C' icon will display on the lower left-hand area of the LCD. Note: With A weighting selected, the meter responds like the human ear (boosting and cutting the noise amplitude over the frequency spectrum - see Appendix). A weighting is used for environmental measurements, OSHA regulatory testing, law enforcement, and workplace design. Select C weighting for flat response measurements (no boost or cut). C weighting is suitable for the sound level analysis of machines, engines, etc. Most OSHA related testing is performed using 'A' Weighting and SLOW Response Time settings. Response Time Change the Response Time by pressing the 'FAST/SLOW' button. The 'FAST' or 'SLOW' icon will display on the lower left-hand area of the LCD. Note: Select FAST to capture noise peaks and noises that occur very quickly. Select the SLOW Mode to monitor a sound source that has a reasonably consistent noise level or to average quickly changing levels. Selection of Fast or Slow is determined by the application and any directives or standards related to that application. Auto/Manual Range Press the RANGE button to scroll through the following ranges: Auto, 30-80dB, 50-100dB, and 80-130dB. The display will reflect the range for each button press. 3

Calibration The Sound Level meter should be calibrated before each use; an external sound level meter calibrator is required. Set the meter to the Manual range (50-100dB), FAST response and A weighting before starting. 1. Place the external calibrator over the Sound Level Meter's microphone and turn the Calibrator on. 2. The meter should read close to, or exactly, the calibrator's db output level. Typical Calibrator output levels are 94dB and 114dB. 3. If the meter is within ± 0.2 db of the calibrator s output, no adjustment is necessary. 4. Adjust the calibration pot in the output/calibration compartment if necessary to bring the meter display in line with the calibrator output signal. Taking Measurements 1. Hold the meter in hand, place it on a desktop (using the rear tilt stand), or mount it on a tripod using the tripod mount on the rear of the meter. 2. Point the microphone toward the source of noise/sound to be measured. 3. Read the measurement, in db units, on the LCD display. Data Hold 1. Press the HOLD button to freeze the displayed reading. The LCD will display the icon HOLD when Data Hold is engaged. 2. Press the HOLD button to de-activate this feature. The HOLD icon will extinguish. 3. Note that Data Hold is not available while the meter is in the Max/Min Record mode. Max Hold 1. Press the MAX HOLD button to activate this feature. The LCD will display PH when Max Hold is engaged. 2. The meter will now display only the highest reading. Each time a higher reading is encountered the display will update. 3. Press the MAX HOLD button again to de-activate this feature. The PH icon will extinguish. 4. Note that Max Hold is not available while the meter is in the Max/Min Record mode. Max/Min Data Recording The Max/Min feature stores the maximum reading and minimum reading while the user takes measurements. The Max and the Min readings can later be recalled. 1. Press the REC MAX/MIN button to activate this feature. The LCD will display the icon REC and the meter will begin monitoring the highest (Max) and lowest (Min) readings. 2. After measurements are made, press the REC button again to view the Max reading. The MAX icon will appear on the LCD along with the highest reading. 3. Press the REC to view the minimum (MIN) reading. The 'MIN' display icon will appear on the LCD along with the lowest reading. 4. To exit this mode, press and hold the REC button until the REC indicator extinguishes. 5. To clear a Max or Min reading, press the HOLD key while viewing either the MAX or MIN value. Note that exiting the Record mode also clears the MAX and MIN values. 4

Analog Output The AC analog output transmits 0.5V AC rms full scale. The output impedance is 600 maximum. The mono 3.5mm mini-jack is located in the output/calibration compartment on the right side of the instrument. Use a phono plug (3.5mm mono) to connect to the output jack. PC Interface The optically isolated RS-232 PC Interface port is located in the output/calibration compartment situated on the lower right side of the meter. The supplied Data Acquisition Software package includes Windows TM 95 / 98 / NT / 2000 / XP compatible software and a meter-to-pc interface cable. Instructions for use can be found on the included software CD. Important Note on the Automatic Power OFF feature The 407768 Sound Level Meter has an AUTO POWER OFF feature that turns the meter off after approximately 10 minutes. This feature must be disabled before starting a datalogging session to avoid having the meter automatically shut off in the middle of a session. Disable it by pressing the REC MAX/MIN button to activate the Record mode. While the meter is in the Record mode, the AUTO POWER OFF feature is disabled. Battery Replacement The 9V battery that powers the Sound Level Meter is housed in the rear battery compartment. When the battery icon appears on the top left corner of the meter's LCD, it is time to replace the battery. 1. Open the battery compartment by first removing the Phillips screw and then sliding the compartment cover down and off. 2. Replace the 9V battery, slide the cover on, and replace the screw. 5

Warranty FLIR Systems, Inc. warrants this Extech Instruments brand device to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department for authorization. Visit the website for contact information. A Return Authorization (RA) number must be issued before any product is returned. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. FLIR Systems, Inc. specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. FLIR s total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration, Repair, and Customer Care Services FLIR Systems, Inc. offers repair and calibration services for the Extech Instruments products we sell. NIST certification for most products is also provided. Call the Customer Service Department for information on calibration services available for this product. Annual calibrations should be performed to verify meter performance and accuracy. Technical support and general customer service is also provided, refer to the contact information provided below. Support Lines: U.S. (877) 439 8324; International: +1 (603) 324 7800 Technical Support: Option 3; E mail: support@extech.com Repair & Returns: Option 4; E mail: repair@extech.com Product specifications are subject to change without notice Please visit our website for the most up to date information FLIR Commercial Systems, Inc., 9 Townsend West, Nashua, NH 03063 USA ISO 9001 Certified Copyright 2013 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form 6

Garantie FLIR Systems, Inc. garantit que cet appareil Extech Instruments est exempt de défauts matériaux et de fabrication pendant un an à partir de la date d envoi (une garantie limitée de six mois s applique aux capteurs et aux câbles). Si le renvoi de l appareil pour réparation devient nécessaire durant ou après la période de garantie, contactez le service client pour autorisation. Pour obtenir les coordonnées, visitez le site Web suivant :. Un numéro d autorisation de retour (AR) doit être délivré avant tout retour de produit. L expéditeur prend à sa charge les frais d expédition, le fret, l assurance et l emballage correct de l appareil afin de prévenir toute détérioration durant le transport. Cette garantie ne s applique pas aux dommages imputables à l utilisateur, tels que l usage impropre ou abusif, un mauvais câblage, une utilisation non conforme aux spécifications, un entretien ou une réparation incorrecte, ou toute modification non autorisée. FLIR Systems, Inc. déclinera spécifiquement toute garantie ou qualité marchande ou aptitude à l emploi prévu, et ne sera en aucun cas tenu responsable pour tout dommage conséquent, direct, indirect ou accidentel. La responsabilité totale de FLIR est limitée à la réparation ou au remplacement du produit. La garantie définie ci dessus est inclusive et aucune autre garantie, écrite ou orale, n est exprimée ou implicite. Calibrage, réparation et services après vente FLIR Systems, Inc. offre des services de calibrage et de réparation pour les produits Extech Instruments que nous commercialisons. Nous fournissons également une certification NIST pour la plupart des produits. Contactez notre service client pour toute information sur les services de calibrage disponibles pour ce produit. Un calibrage doit être effectué chaque année pour vérifier les performances et la précision du mètre. Nous offrons également une assistance technique et un service à la clientèle. Veuillez vous reporter aux coordonnées fournies ci dessous. Lignes d assistance: États Unis (877) 439 8324; international: +1 (603) 324 7800 Service d assistance technique : Option 3 ; E mail : support@extech.com Réparations et retours : Option 4 ; E mail : repair@extech.com Les spécifications produit sont sujettes à modifications sans préavis. Pour les toutes dernières informations, veuillez visiter notre site Web. FLIR Commercial Systems, Inc., 9 Townsend West, Nashua, NH 03063 USA Certifié ISO 9001 Copyright 2013 FLIR Systems, Inc. Tous droits réservés, y compris la reproduction partielle ou totale sous quelque forme que ce soit. 7

Garantía FLIR Systems, Inc., garantiza este dispositivo marca Extech Instruments para estar libre de defectos en partes o mano de obra durante un año a partir de la fecha de embarque (se aplica una garantía limitada de seis meses para cables y sensores). Si fuera necesario regresar el instrumento para servicio durante o después del periodo de garantía, llame al Departamento de Servicio a Clientes para obtener autorización. Visite para Información de contacto. Se debe expedir un número de Autorización de Devolución (AD) antes de regresar cualquier producto. El remitente es responsable de los gastos de embarque, flete, seguro y empaque apropiado para prevenir daños en tránsito. Esta garantía no se aplica a defectos resultantes de las acciones del usuario como el mal uso, alambrado equivocado, operación fuera de las especificaciones, mantenimiento o reparación inadecuada o modificación no autorizada. FLIR Systems, Inc., rechaza específicamente cualesquier garantías implícitas o factibilidad de comercialización o idoneidad para cualquier propósito determinado y no será responsable por cualesquier daños directos, indirectos, incidentales o consecuentes. La responsabilidad total de FLIR está limitada a la reparación o reemplazo del producto. La garantía precedente es inclusiva y no hay otra garantía ya sea escrita u oral, expresa o implícita. Servicios de calibración, reparación y atención a clientes FLIR Systems, Inc., ofrece servicios de reparación y calibración para los productos que vendemos de Extech Instruments. Además ofrecemos certificación NIST para la mayoría de los productos. Llame al Departamento de Servicio al Cliente para solicitar información de calibración para este producto. Para verificar el funcionamiento y precisión se debe realizar la calibración anual. Además se provee Soporte Técnico y servicios generales al cliente, consulte la información de contacto en seguida. Líneas de soporte: EE.UU. (877) 439 8324; Internacional: +1 (603) 324 7800 Soporte Técnico Opción 3; correo electrónico: support@extech.com Reparación / Devoluciones: Opción 4; correo electrónico: repair@extech.com Las especificaciones del producto están sujetas a cambios sin aviso Por favor visite nuestra página en Internet para la información más actualizada FLIR Commercial Systems, Inc., 9 Townsend West, Nashua, NH 03063 USA Certificado ISO 9001 Copyright 2013 FLIR Systems, Inc. Reservados todos los derechos, incluyendo el derecho de reproducción total o parcial en cualquier medio 8

Appendix Typical 'A' Weighted db levels 50 HP Siren (100') 130 140 Jet take-off (200') 120 Riveting machine 110 100 Chain saw Subway (20') 90 Boiler room Pneumatic drill (50') Vacuum cleaner (10') Large store 70 80 60 Freight train (100') Speech (1') Large Office Small office 50 Residence Residential area (night) Whisper (5') 30 40 20 Sound studio 10 Threshold of hearing 0 Frequency Weighting Graph Frequency Weighting db (relative) 5 0-5 -10-15 -20-25 -30-35 -40-45 10 100 1000 10000 Frequency (Hz) 'A' Weighting 'C' Weighting 9