Type 3046 Automatic Pilots



Documents pareils
Contrôle d'accès Access control. Notice technique / Technical Manual

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Notice Technique / Technical Manual

Fabricant. 2 terminals

Lavatory Faucet. Instruction Manual. Questions?

R.V. Table Mounting Instructions

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Paxton. ins Net2 desktop reader USB

Stainless Steel Solar Wall Light

APPENDIX 6 BONUS RING FORMAT

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Garage Door Monitor Model 829LM

Le No.1 de l économie d énergie pour patinoires.

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Embases pour raccordement G1/8 - G1/4

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Contrôle d accès Access control MOD-TCPIP-AI. Notice technique / Technical Manual

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Instructions Mozilla Thunderbird Page 1

SYSTÈME JETS D AIR WISH WISH AIR JETS SYSTEM Système de massage à jets d air pour bains en polymère - Air jet massage system for polymer bathtubs

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

Package Contents. System Requirements. Before You Begin

How to Login to Career Page

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

ARP-090G / ARP-090K NOTICE D'EMPLOI INSTRUCTION MANUAL

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

PARIS ROISSY CHARLES DE GAULLE

Guide d'installation rapide TFM-560X YO.13

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

BILL 203 PROJET DE LOI 203

Guide d installation Deco Drain inc. DD200

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

DOCUMENTATION - FRANCAIS... 2

NEW Fin Fan / Air cooled condenser cleaning

Folio Case User s Guide

Contents Windows

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

Water Heaters. Use & Care Manual. Electric Residential. With Installation Instructions for the Installer. Double Element Residential Electric Models

ENGLISH 4 FRANÇAIS 6 ESPAÑOL 8

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

User guide Conference phone Konftel 100

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

Sécurité relative aux sièges auto et aux rehausseurs

THE LAW SOCIETY OF UPPER CANADA BY-LAW 19 [HANDLING OF MONEY AND OTHER PROPERTY] MOTION TO BE MOVED AT THE MEETING OF CONVOCATION ON JANUARY 24, 2002

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Once the installation is complete, you can delete the temporary Zip files..

MODE D EMPLOI USER MANUAL

FCM 2015 ANNUAL CONFERENCE AND TRADE SHOW Terms and Conditions for Delegates and Companions Shaw Convention Centre, Edmonton, AB June 5 8, 2015

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

Quick Installation Guide TEW-AO12O

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

AND / ET USER GUIDE UK HARDWIRED CONTROL PANEL UK GUIDE UTILISATEUR CENTRALE D ALARME FILAIRE F

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

ETABLISSEMENT D ENSEIGNEMENT OU ORGANISME DE FORMATION / UNIVERSITY OR COLLEGE:

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

WEB page builder and server for SCADA applications usable from a WEB navigator

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

SERVEUR DÉDIÉ DOCUMENTATION

Manuel d'utilisation

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

INSTRUCTIONS D INSTALLATION MODÈLE

SM6. fiche adaptation adaptation instructions. résistances chauffantes. heating resistors. distribution MT ensembles préfabriqués à votre service

Free filter reminders! Sign up online at: santevia.com/filterease. need help? Contact Santevia!

Principe de TrueCrypt. Créer un volume pour TrueCrypt

GASKET FOR TONER COLLECTION BOTTLE

If you understand the roles nouns (and their accompanying baggage) play in a sentence...

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

22/09/2014 sur la base de 55,03 euros par action

Product Overview Présentation produits

Gestion des prestations Volontaire

L. Obert, T. Lascar, A. Adam

Utiliser une WebCam. Micro-ordinateurs, informations, idées, trucs et astuces

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

SYSTÈME DE GAINES À SPIRALE ET RACCORDS TOURNANTS

FO-FDHB6-1 Central Heat Blower Kit for Onyx, Opel and Delta

Interest Rate for Customs Purposes Regulations. Règlement sur le taux d intérêt aux fins des douanes CONSOLIDATION CODIFICATION

Bill 69 Projet de loi 69

CEPF FINAL PROJECT COMPLETION REPORT

Bill 204 Projet de loi 204

Spécial Catégorie 6 Patch Cords

IPSAS 32 «Service concession arrangements» (SCA) Marie-Pierre Cordier Baudouin Griton, IPSAS Board

POLICY: FREE MILK PROGRAM CODE: CS-4

Credit Note and Debit Note Information (GST/ HST) Regulations

An Act to Amend the Tobacco Sales Act. Loi modifiant la Loi sur les ventes de tabac CHAPTER 46 CHAPITRE 46

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

Practice Direction. Class Proceedings

Maximum Capacity / Capacité maximal: 10 kg/min

Critères à l attention des fabricants et des fournisseurs de biens ou de services : dispositifs mécaniques pour bingo

Laboratory accredited by the French Home Office (official gazette date February 5 th, 1959, modified) Valid five years from August 27 th, 2013

PROJET DE LOI. An Act to Amend the Employment Standards Act. Loi modifiant la Loi sur les normes d emploi

Editing and managing Systems engineering processes at Snecma

Classes of protection IP 65 / IP66 / IP 67 ATEX zone protection Eex "ia" Eex "ed" Eex "em" ATEX II2 G/D

Application Form/ Formulaire de demande

Transcription:

WHITE-RODGERS Type 046 Automatic Pilots INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION Operator: Save these instructions for future use Automatic pilots are required on gas-fired heating equipment to prevent the flow of gas to the main burner if the pilot flame is not burning or is insufficient to properly ignite the main burner. This pilot has automatic reset (automatic recycling) needing merely relighting or possibly only the resumption of proper gas pressure to put back in operation. If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor, electrician, or someone familiar with basic electricity and wiring. Do not exceed the specification ratings. All wiring must conform to local and national electrical codes and ordinances. This control is a precision instrument, and should be handled carefully. Rough handling or distorting components could cause the control to malfunction. WARNING Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard. These Pilots can be used with either A, B, or E series pilot burners. Pilot Burners are available in 14 port arrangements, Bunsen and Non-linting, and with a wide choice of mounting facilities. Contact Action is SPST snap-action, close-on-rise. These automatic pilots may be used with natural, manufactured, or mixed gases, and with LP gases where means are provided for obtaining a 100% shutoff system. The pilot burner should be equipped with the recommended size orifice fitting. The metal box containing the switch may be conveniently mounted in any position. The cover is easily removed, making the switch terminals readily accessible. CAUTION PRECAUTIONS To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete. Shut off main gas to heating system until installation is complete. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Following installation or replacement, follow appliance manufacturer s recommended installation and/or service instructions to insure proper operation. SPECIFICATIONS Orifice fittings offer three different styles of connections each available for the most used gases. Timing: Contacts close approximately 60 seconds after the pilot is ignited. Contacts open approximately 40 seconds after the flame is extinguished. ATTENTION This product contains mercury. There will not be any exposure to mercury under normal conditions of use. This product may replace a unit which contains mercury. Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury. Wearing nonabsorbent gloves, take up the spilled mercury with sand or other absorbent material and place into a container which can be sealed. If a cell becomes damaged, the unit should be discarded. Mercury must not be discarded in household trash. When this unit or the unit it is replacing is to be discarded, place in a suitable container and return to us. WHITE-RODGERS DIVISION EMERSON ELECTRIC CO. 9797 REAVIS RD., ST. LOUIS, MO. 612-598 (14) 577-100, FAX (14) 577-1517 9999 HWY. 48, MARKHAM, ONT. LP J (905) 475-465, FAX (905) 475-4625 Printed in U.S.A. PART NO. 7-061G Replaces 7-061F 9651

INSTALLATION CAUTION To avoid personal injury and/or property damage, shut off gas and electric to heating system until installation is complete. Uncoil the capillary carefully, making certain that it is not bent sharply at any place. Be particularly careful with that part of the capillary connected to the diaphragm. The thermal element of the automatic pilot may be attached to the pilot burner either before of after the pilot burner is mounted to the main burner. To attach the thermal element to the pilot burner: remove nut and lockwasher, slip thermal element into bracket of pilot burner so that screw on element extends through the hole in bracket. Then fasten with nut and lockwasher. The orifice fitting should then be screwed into the pilot burner and the tubing connected to the orifice fitting. The proper location of an automatic pilot, with respect to the main burner, should be determined by the manufacturer of the burner according to the requirements of the American Gas Association and the local gas utility. 1. The operating temperatures, as taken by thermocouples attached to the surface of the automatic pilot and pilot burner at the points shown below, must not exceed the following: 2. The automatic pilot must be mounted near enough to the main gas burner so it is easily ignited by the pilot ignition flame even when the pilot flame is reduced to the point where it is just sufficient to keep the pilot switch contacts closed.. Proper functioning of the automatic pilot requires that the flame from the main gas burner not touch any part of the automatic pilot. 4. The pilot burner must be positioned so as to receive incoming secondary air and not the products of combustion. 5. Unless protected from strong drafts of secondary air, which tend to carry the flame away from the bulb, the automatic pilot may not be supplied with sufficient heat for proper operation. 6. It is recommended that on installations burning manufactured gas, an approved filter of sufficient capacity be connected into the pilot gas line to prevent formation of gum at the orifice. Bleed Burners are available for vertical or horizontal pilots. 1. Tip of pilot burner, 1200 F. 2. Tip of thermal element, 1400 F.. Orifice fitting, 475 F. 4. Capilllary 500 F. 5. Terminal screw on pilot, 175 F. 2 1 Horizontal Vertical 5 7. Bleed tubes are available for attaching to the bracket of the pilot burner. This tube is for burning the bleed gas from the diaphragm gas valve and from the pressure regulator and should be connected accordingly. 4 WIRING CAUTION To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete. All wiring should be installed in accordance with local and national electrical codes and ordinances. NOTE These typical wiring diagrams show only the terminal identification and wiring hook up. Always refer to wiring instructions provided by equipment manufacturer for system hookup operation. 2

THERMOSTAT CONNECT TRANSFORMER HERE IF VALVE IS LOW VOLTAGE TO HIGH THIS WIRING DIAGRAM MAY BE USED FOR OR LOW VOLTAGE SILENT KNIGHT VALVES WITH CONDUIT CONNECTOR. IF VOLTAGE, A VOLTAGE THERMOSTAT MUST BE USED. IF LOW VOLTAGE, TRANSFORMER WILL BE USED IN. Diagram for Silent Knight valve with conduit connector SILENT KNIGHT GAS VALVE THERMOSTAT AUX 2 TH TR 1 4 HIGH 24 VAC TRANSFORMER SILENT KNIGHT GAS VALVE Diagram for Silent Knight valve with terminal panel TO ROOM THERMOSTAT (RED-BLACK CONTROL RESISTOR) THERMOSTAT (HEATER SET TO.4) CONTROL THERM TRANS TO 24 VAC UNION NUT TRANSFORMER TRANSFORMER 24 VAC Diagram using diaphragm valve CUSHIONED POWER SOLENOID GAS VALVE Diagram using solenoid valve The following procedure should be closely followed when lighting the Automatic Pilot: 1. Set the room thermostat to the lowest setting on the dial. 2. Make certain that the main gas supply cock and the pilot gas cock have been closed for at least five minutes to permit the combustion chamber to vent itself.. Open the pilot gas cock. LIGHTING THE 4. Light the pilot with a match supported on the end of a wire or stick long enough to avoid putting your arm or hand inside the combustion chamber. 5. After the pilot flame is burning, open the main gas supply cock. 6. The main burner ignites when the room thermostat is set to a temperature above that which exists in the room at that particular instant. As doing this closes the contacts of the thermostat, the circuit is completed to the gas valve. 1. While the main burner is operating, close the pilot gas cock and the main gas cock, shutting off the gas to both the pilot and the main burner. 2. Within 60 seconds, a slight sound should be noted which will indicate that the gas valve supplying the main burner is closed. The thermostat and limit control contacts must be closed during this test. TESTING THE. After a wait of about five minutes, relight the pilot according to the instructions listed under Lighting the Pilot. Within 90 seconds another slight sound will be heard, indicating that the gas valve supplying gas to the main burner is energized. 4. Open the main gas cock once again.

WHITE-RODGERS s s TYPE 046 INSTRUCTIONS D INSTALLATION Utilisateur: conservez ces instructions pour vous y référer au besoin SI VOUS NE LISEZ PAS ATTENTIVEMENT CES INSTRUCTIONS AVANT D INSTALLER ET D UTILISER LA COMMANDE, VOUS RISQUEZ DE CAUSER DES BLESSURES ET DES DOMMAGES MATÉRIELS. DESCRIPTION L utilisation de ce type de veilleuse est nécessaire avec les équipements à gaz afin de couper le débit de gaz au brûleur principal si la flamme est éteinte ou si elle ne suffit pas à allumer correctement le brûleur principal. La veilleuse est remise en marche ment lorsque la flamme est rallumée ou lorsque la pression de gaz est revenue à la normale. Si vous n êtes pas certain de la tension du câblage de votre système (soit en millivolts, à basse tension ou à la tension du ), faites inspecter celui-ci par un électricien, un entrepreneur agréé en chauffage et climatisation ou une personne qui a des connaissances de base en électricité et en câblage. Ne dépassez pas les charges nominales. Tout le câblage doit être conforme aux codes et règlements locaux et nationaux qui régissent les installations électriques. Cette commande est un instrument de précision qui doit être manipulé avec soin. Elle peut se détraquer si elle est manipulée de façon négligente ou si des composantes sont déformées. ADVERTISSEMENT N installez pas cet appareil sur des circuits qui dépassent la tension nominale. Une tension trop élevée peut endommager la commande et poser des risques de chocs électriques et d incendie. Ces veilleuses peuvent servir avec les brûleurs de veilleuse des séries A, B et E. Les brûleurs de veilleuse sont disponibles avec 14 dispositions de buses différentes, de type Bunsen ou à filtre, avec diverses options de montage. L action du contact est une action rapide unipolaire à une direction, à fermeture en montée. La veilleuse peut servir avec des systèmes à gaz naturel, manufacturé ou mixte ou encore, lorsque la fermeture complète est assurée, avec des systèmes à gaz de pétrole liquide. Veuillez doter le brûleur de veilleuse d un raccord d entrée du calibre recommandé. Le boîtier métallique qui contient le commutateur peut être installé dans n importe quelle orientation. Le couvercle est facilement amovible, ce qui facilite l accès aux bornes. PRÉCAUTIONS ATTENTION Afin de prévenir les chocs électriques et les dommages matériels, coupez l alimentation du système au panneau de distribution électrique principal pendant toute la durée de l installation. Coupez pendant toute la durée de l installation le gaz qui alimente le système de chauffage. Lorsque vous révisez une commande, étiquetez tous les fils avant de les débrancher. Les erreurs de câblage peuvent entraîner un fonctionnement incorrect et dangereux de l équipement. Pour assurer un fonctionnement adéquat de l équipement après l installation ou le remplacement, veuillez vous référer aux directives d installation ou de révision du fabricant. SPÉCIFICATIONS Les raccords d entrée sont offerts avec trois styles de raccordement disponibles pour les types de gaz les plus communs. Délais : Les contacts sont fermés environ 60 secondes après l allumage de la veilleuse. Les contacts sont ouverts environ 40 secondes après que la flamme se soit éteinte. ATTENTION Cet appareil contient du mercure. Il n y a aucun risque d exposition lorsque l appareil est utilisé normalement. N ouvrez pas les cellules de mercure. Si une cellule est endommagée, ne touchez pas au mercure qui s en échappe. Enfilez des gants étanches et nettoyez le mercure avec du sable ou une autre substance absorbante, puis placez le matériel contaminé dans un contenant qui peut être fermé hermétiquement. Si une cellule est endommagée, l appareil en entier doit être jeté. Ne pas jeter de mercure avec les ordures ménagères. Si vous devez jeter cet appareil ou celui qu il remplace, placez-le dans un contenant convenable et faites-le nous parvenir. WHITE-RODGERS DIVISION EMERSON ELECTRIC CO. 9797 REAVIS RD., ST. LOUIS, MO. 612-598 (14) 577-100, FAX (14) 577-1517 9999 HWY. 48, MARKHAM, ONT. LP J (905) 475-465, FAX (905) 475-4625 Imprimé aux É.-U.A PIÈCE NO 7-061G Remplace 7-061F 9651

INSTALLATION ADVERTISSEMENT Afin de prévenir les blessures et les dommages matériels, coupez le gaz et l électricité qui alimentent le système de chauffage jusqu à ce que l installation soit terminée. Déroulez soigneusement le tube capillaire en vous assurant qu il n est plié en aucun endroit. Faites particulièrement attention lorsque vous manipulez la partie du capillaire qui est raccordée sur la membrane. Le capteur thermique de la commande peut être fixé au brûleur de veilleuse soit avant, soit après que la veilleuse ait été installée sur le brûleur principal. Pour monter le capteur thermique sur le brûleur de veilleuse, retirez d abord l écrou et la rondelle de blocage, puis glissez le capteur dans le support du brûleur de veilleuse en passant la vis du capteur dans le trou du support. Fixez le capteur à l aide de l écrou et de la rondelle de blocage. Vissez ensuite le raccord d entrée dans le brûleur de veilleuse, puis raccordez le tube au raccord. L emplacement idéal d une veilleuse par rapport au brûleur principal doit être déterminé par le fabricant du brûleur, conformément aux exigences de l AGA, du CGA et du distributeur de gaz local. 1. Les températures d exploitation, mesurées par des thermocouples fixés à la surface de la veilleuse et du brûleur de veilleuse aux endroits indiqués en l illustration, ne doivent pas dépasser les valeurs suivantes : 1. Au bout du brûleur de veilleuse : 650 C (1 200 F). 2. Au bout du capteur thermique : 760 C (1 400 F).. Sur le raccord d entrée : 245 C (475 F). 4. Sur le capillaire : 260 C (500 F). 5. Vis de la borne du pilote : 80 C (175 F). 2 1 2. La veilleuse doit être installée assez près du brûleur à gaz principal pour assurer que celui-ci soit allumé par la flamme de la veilleuse même lorsque cette flamme a été réduite au point où elle suffit tout juste à maintenir fermés les contacts du commutateur de veilleuse.. Pour que la veilleuse fonctionne correctement, la flamme du brûleur principal ne doit en toucher aucune composante. 4. Le brûleur de veilleuse doit être orienté de façon à brûler de l air secondaire et non des produits de combustion. 5. Si elle n est pas protégée des puissants courants d air secondaire, qui ont tendance à éloigner la flamme de la cuvette, la veilleuse risque de ne pas être chauffée suffisamment pour fonctionner adéquatement. 6. Dans le cas d installations qui brûlent du gaz manufacturé, il est recommandé de raccorder à la conduite de gaz de veilleuse un filtre homologué et de capacité suffisante afin de prévenir la formation de gomme à l entrée. 7. Des tubes de purge sont disponibles qui peuvent être montés sur le support du brûleur de veilleuse. Ces tubes servent à brûler les gaz de purge du robinet de gaz à membrane et du régulateur de pression et ils doivent être raccordés en conséquence. Des brûleurs de gaz de purge sont disponibles pour les veilleuses horizontales et verticales 5 Horizontal Vertical CÂBLAGE 4 ATTENTION Afin de prévenir les chocs électriques et les dommages matériels, coupez l alimentation du système au panneau de distribution électrique principal pendant toute la durée de l installation. Tout le câblage doit être conforme aux codes et règlements locaux et nationaux qui régissent les installations électriques. NOTE Ces schémas de câblage ne représentent que l identification des bornes et le branchement des fils. Toujours consulter les directives de câblage fournies par le fabricant du matériel pour réaliser l opération de branchement du systéme. 2

Thermostat Raccorder le transformateur ici si le robinet est à basse tension Limiteur à maximum Thermostat Limiteur à maximum Ce schéma de câblage peut servir pour les robinets «Silent Knight» à basse tension ou à tension du qui sont dotés d un raccordement de conduite. Si le robinet est à la tension du, le thermostat doit aussi l être. Si le robinet est à basse tension, un transformateur doit être installé sur le circuit. Schéma pour un robinet «Silent Knight» avec raccordement de conduite Robinet à gaz «Silent Knight» AUX 2 TH TR 1 4 Robinet à gaz «Silent Knight» Transformateur 24 V c.a. Schéma pour un robinet «Silent Knight» avec bornier Thermostat d ambiance (Résistance rouge et noire) Limiteur Thermostat (élément chauffant réglé à 0,4) Limiteur THERM TRANS Transformateur 24 V c.a. Écrou-union Transformateur 24 V c.a. Schéma pour robinet à membrane Robinet à gaz à solénoïde Schéma pour robinet à gaz à solénoïde Pour allumer la veilleuse, suivez exactement la démarche suivante : 1. Réglez le thermostat d ambiance au point de consigne le plus bas. 2. Assurez-vous que le robinet à gaz principal et le robinet à gaz de la veilleuse ont été fermés depuis au moins cinq minutes afin de laisser aérer la chambre de combustion.. Ouvrez le robinet d alimentation de gaz de la veilleuse. ALLUMAGE DE LA VEILLEUSE 4. Allumez la veilleuse en vous servant d une allumette fixée au bout d un fil de fer ou d une tige de longueur suffisante pour vous éviter d insérer le bras ou la main dans la chambre de combustion. 5. Une fois que la veilleuse est allumée, ouvrez le robinet principal d alimentation de gaz. 6. Lorsque le point de consigne du thermostat est supérieur à la température de la pièce, les contacts du thermostat sont fermés, ce qui ferme le circuit du robinet à gaz et allume le brûleur principal. 1. Alors que le brûleur principal est en marche, fermez le robinet de la veilleuse et le robinet principal, coupant ainsi le gaz qui alimente la veilleuse et le brûleur principal. 2. Après moins de 60 secondes, vous devriez entendre un léger bruit qui représente la fermeture du robinet à gaz qui alimente le brûleur principal. Lors des vérifications, les contacts du thermostat et des limiteurs doivent être fermés. VÉRIFICATION DE LA VEILLEUSE. Attendez environ cinq minutes, puis rallumez la veilleuse conformément aux directives de la section «Allumage de la veilleuse». Après moins de 90 secondes, vous devriez encore une fois entendre un léger bruit qui signifie que le brûleur principal a été mis sous tension. 4. Ouvrez ensuite le robinet principal.