Powermax65/85 Machine Interface Cable with Voltage Divider Board Câble d interface de machine avec panneau diviseur de tension des Powermax65/85

Documents pareils
Folio Case User s Guide

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Lavatory Faucet. Instruction Manual. Questions?

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

R.V. Table Mounting Instructions

Contents Windows

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

Notice Technique / Technical Manual

Logitech Speaker System Z553 Setup Guide Guide d installation

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

Package Contents. System Requirements. Before You Begin

Instructions Mozilla Thunderbird Page 1

SYSTÈME JETS D AIR WISH WISH AIR JETS SYSTEM Système de massage à jets d air pour bains en polymère - Air jet massage system for polymer bathtubs

ENGLISH 4 FRANÇAIS 6 ESPAÑOL 8

Paxton. ins Net2 desktop reader USB

Guide d'installation rapide TFM-560X YO.13

Contrôle d'accès Access control. Notice technique / Technical Manual

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

Fabricant. 2 terminals

Panneau d alimentation de Store Cellulaire

PARIS ROISSY CHARLES DE GAULLE

Garage Door Monitor Model 829LM

DOCUMENTATION - FRANCAIS... 2

Stainless Steel Solar Wall Light

Le No.1 de l économie d énergie pour patinoires.

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Now enhanced with powerful workplace solutions Maintenant amélioré, diet+ vous offre de puissantes solutions novatrices pour le milieu de travail

AUTO ER ADAPT ER SPECIAL USE WARNING

How to Login to Career Page

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Z-Axis Compliance Device Compliance en z

Guide de démarrage du système modulaire Sun Blade 6000

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

Sécurité relative aux sièges auto et aux rehausseurs

MONTEGO 3 PERSON CUSHION GARDEN SWING WITH CANOPY ASSEMBLY INSTRUCTIONS ITEM# SC-177-2GS

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

Trim Kit Installation Instruction

PRESENTATION REMOTE TÉLÉCOMMANDE DE PRÉSENTATION. User Guide Manuel de l utilisateur

Loi sur l aide financière à la Banque Commerciale du Canada. Canadian Commercial Bank Financial Assistance Act CODIFICATION CONSOLIDATION

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Logitech Wireless Performance Combo MX800 Setup Guide Guide d installation

Editing and managing Systems engineering processes at Snecma

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Start Here Point de départ

VTP. LAN Switching and Wireless Chapitre 4

NEW Fin Fan / Air cooled condenser cleaning

INSTRUCTIONS D INSTALLATION MODÈLE

Guide d installation Deco Drain inc. DD200

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

Stérilisation / Sterilization

PRINCIPE DE HOTTE SPÉCIALE COMPLÈTE TYPE «RHC» COMPLETE «RHC» TYPE SPECIAL HOOD SYSTEM

DOCUMENTATION - FRANCAIS... 2

Credit Note and Debit Note Information (GST/ HST) Regulations

Utiliser une WebCam. Micro-ordinateurs, informations, idées, trucs et astuces

Start Here Point de départ Epson Stylus

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

Embases pour raccordement G1/8 - G1/4

Laboratory accredited by the French Home Office (official gazette date February 5 th, 1959, modified) Valid five years from August 27 th, 2013

Ships Elevator Regulations. Règlement sur les ascenseurs de navires CODIFICATION CONSOLIDATION. C.R.C., c C.R.C., ch. 1482

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

GAME CONTENTS CONTENU DU JEU OBJECT OF THE GAME BUT DU JEU

SunATM 4.0 Release Notes

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

en SCÈNE RATIONAL Rational Démonstration SDP : automatisation de la chaîne de développement Samira BATAOUCHE sbataouche@fr.ibm.com

Quick start guide. HTL1170B

RAPID Prenez le contrôle sur vos données

Once the installation is complete, you can delete the temporary Zip files..

SERVEUR DÉDIÉ DOCUMENTATION

SERIE TS-770 SYSTEME CONFERENCE

Bill 204 Projet de loi 204

22/09/2014 sur la base de 55,03 euros par action

Monitor LRD. Table des matières

SYSTÈME DE GAINES À SPIRALE ET RACCORDS TOURNANTS

APPENDIX 6 BONUS RING FORMAT

Lesson Plan Physical Descriptions. belle vieille grande petite grosse laide mignonne jolie. beau vieux grand petit gros laid mignon

Spécial Catégorie 6 Patch Cords

Multiple issuers. La cotation des actions ROBECO ci-dessous est suspendue sur EURONEXT PARIS dans les conditions suivantes :

AUDIT COMMITTEE: TERMS OF REFERENCE

WEB page builder and server for SCADA applications usable from a WEB navigator

Guide de récupération de Windows Server 2003 R2 pour serveurs Sun x64

Cedric Dumoulin (C) The Java EE 7 Tutorial

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

Sun Java SystemWeb Server 7.0 Documentation Center

Material Banking Group Percentage Regulations. Règlement fixant le pourcentage (groupe bancaire important) CONSOLIDATION CODIFICATION


The impacts of m-payment on financial services Novembre 2011

Order Binding Certain Agents of Her Majesty for the Purposes of Part 1 of the Personal Information Protection and Electronic Documents Act

Igloo. Congélateurs Ultra-Froid -45 o C & -86 o C Armoires & Coffres 370 à 830 litres

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

Règlement relatif à l examen fait conformément à la Déclaration canadienne des droits. Canadian Bill of Rights Examination Regulations CODIFICATION

L. Obert, T. Lascar, A. Adam

GASKET FOR TONER COLLECTION BOTTLE

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

CLASSIFICATION REPORT OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2007

Transcription:

Powermax65/85 Machine Interface Cable with Voltage Divider Board Câble d interface de machine avec panneau diviseur de tension des Powermax65/85 Field Service Bulletin Bulletin de service sur le terrain 806980 Revision February 05 Révision Février 05

Machine Interface Cable with Voltage Divider Board WARNING ELECTRIC SHOCK CAN KILL Disconnect electrical power before performing any maintenance. See the Safety and Compliance Manual included with your system for more safety precautions. Introduction Purpose This Field Service Bulletin describes the procedure for installing an internal CPC machine interface port, cable, and voltage divider board. Materials and tools Blade screwdriver Assorted Phillips and TORX screwdrivers Kit 8697 contents Part number Description Quantity 075534 PLASTITE #6 X 5/6 pan head screw 4 3036 Powermax65/85 Machine interface cable with voltage divider Field Service Bulletin

Machine Interface Cable with Voltage Divider Board About the Powermax65/85 voltage divider The Powermax65 and Powermax85 power supplies are designed to use an optional, five-position voltage divider. The internal voltage divider provides a scaled down arc voltage of 0:,.:, 30:, 40:, and 50: (maximum output of 8 V). A receptacle on the rear of the power supply provides access to the scaled down arc voltage and signals for arc transfer and plasma start. Note: The factory presets the voltage divider to 50:. To change the voltage divider to a different setting, refer to the instructions later in this Field Service Bulletin. CAUTION: The internal voltage divider provides a maximum of 8 V under open circuit conditions. This is an impedance-protected functional extra low voltage (ELV) output to prevent shock, energy, and fire under normal conditions at the machine interface receptacle and under single fault conditions with the machine interface wiring. The voltage divider is not fault tolerant and ELV outputs do not comply with safety extra low voltage (SELV) requirements for direct connection to computer products. Field Service Bulletin

Machine Interface Cable with Voltage Divider Board Remove the power supply cover and Mylar barrier. Turn OFF the power, disconnect the power cord, and disconnect the gas supply.. Remove the 8 small screws () from the power supply cover. 3. Remove the 8 large screws () from the power supply cover. 4. Lift the cover (3) off the power supply. 3 5. Remove the component barrier from the power-board side of the power supply. The barrier is flexible and can be bent slightly for removal. Field Service Bulletin 3

Machine Interface Cable with Voltage Divider Board Install the voltage divider board with CPC port and cables. Secure the voltage divider board to the right of the power supply fan with two screws (075534). Top grommet Screws (075534) Bottom grommet. Remove the round plastic plug that covers the CPC opening in the rear panel. Plastic CPC plug on rear panel of power supply 4 Field Service Bulletin

Machine Interface Cable with Voltage Divider Board 3. Route the CPC port and attached cables above the fan housing and over to the CPC port opening on the rear panel of the power supply. 4. Insert the CPC port into the CPC port opening from inside the power supply. Be sure to position the port with the green/yellow ground wire at the bottom of the port. CPC port opening CPC port Screw (075534) Green/yellow ground wire Screw (075534) Screw to secure ground wire to gas filter housing 5. Secure the port with two screws (075534). Two screws are sufficient when inserted in opposite corners of the CPC port. 6. Attach the green/yellow ground wire to the gas filter housing using the screw at the right-front corner of the housing. Note: This screw also connects another ground wire to the gas filter housing the ground wire in the power supply that connects at its other end to the center panel. Field Service Bulletin 5

Machine Interface Cable with Voltage Divider Board Loosen the front panel of the power supply To provide easy access for connecting the interface cables to the power board:. Remove the metal strap from the top of the power supply by lifting the strap straight up. The strap holds the two end panels together.. Carefully place the power supply onto the fan side to access the bottom screws. 3. Remove the two screws that hold the front panel to the bottom of the power supply. 4. Using a blade screwdriver, carefully pry the front panel off the bottom of the power supply. 5. Position the power supply upright. 6. Carefully pull the front panel away from the body of the power supply. The front panel is still attached to the power supply body and can only move a short distance. 6 Field Service Bulletin

Machine Interface Cable with Voltage Divider Board Route and attach the cables to the power board. Route the large cable (from the CPC port) through the top grommet above the voltage divider board and down the side of the power board to the connector (J for both CSA and CE).. Push the cable connector onto the power board connector (J for both CSA and CE). Be sure to align the red wire in the cable connector with RED that is printed on the power board. 3. Route the small cable (from the right side of the voltage divider board) through the bottom grommet above the voltage divider board and down the side of the power board to the connector (J3 for CSA, J33 for CE) 4. Push the cable connector onto the power board connector (J3 for CSA, J33 for CE). Be sure to align the red wire in the cable connector with RED that is printed on the power board. Large cable RED J Small cable RED J3 (CSA) J33 (CE) Field Service Bulletin 7

Machine Interface Cable with Voltage Divider Board Set the five-position voltage divider on the Powermax65/85 The factory presets the voltage divider to 50:. To change the voltage divider to a different setting:. Locate the voltage divider DIP switches on the voltage divider board. The figure below shows the default setting (50:) with the number 4 switch up.. Set the DIP switches to one of the following settings. 0:.: 30: 40: 50: Secure the front panel to the power supply. Carefully place the power supply onto the fan side.. Carefully push the bottom of the front panel onto the bottom of the power supply. Be sure not to pinch any wires between the front panel and the heat sink on the power supply. 3. Secure the front panel to the bottom of the power supply with the two screws. 4. Position the power supply upright. 5. Replace the metal strap on top of the power supply by pushing the strap straight down. The four pins in the strap snap into the front and rear panels. 8 Field Service Bulletin

Machine Interface Cable with Voltage Divider Board Replace the component barrier. Carefully push in the sides () of the component barrier so that the barrier bends out slightly at the top and bottom ().. Slide the sides of the barrier behind the power supply frame (3). Be careful to get the barrier between the frame and the power wires on the right side of the power board (4). 3. Gently bend the top of the barrier at the perforation so that the top bends over the top of the power supply. 4. Slide the barrier down so that the bottom edge fits inside the power supply frame (5). 4 3 3 3 3 5 Field Service Bulletin 9

Machine Interface Cable with Voltage Divider Board Replace the power supply cover. Place the cover (3) over the power supply. Be careful not to pinch any wires.. Install the 8 small screws () into the power supply cover. Tighten the screws to 5 in lbs (7.3 kg cm). 3. Install the 8 large screws () into the power supply cover. Tighten the screws to 5 in lbs (7.3 kg cm). Front of power supply 3 0 Field Service Bulletin

Câble d interface de machine avec panneau diviseur de tension AVERTISSEMENT LES CHOCS ÉLECTRIQUES PEUVENT ÊTRE FATALS Débrancher l alimentation électrique avant tout entretien. Se reporter au Manuel de sécurité et de conformité compris avec votre système pour d autres précautions de sécurité. Introduction Objet Le présent bulletin de service sur le terrain décrit la procédure d installation d un port d interface de machine CPC, de son câble ainsi que du panneau diviseur de tension. Matériel et outils requis Tournevis plat Tournevis Phillips et TORX assortis Contenu de la trousse 8697 Numéro de référence Description Quantité 075534 Vis à tête cylindrique bombée PLASTITE N 6 x 5/6 4 3036 Câble d interface de machine avec panneau diviseur de tension du Powermax65/85 Bulletin de service sur le terrain

Câble d interface de machine avec panneau diviseur de tension À propos du diviseur de tension du Powermax65/85 Les sources de courant des Powermax65 et Powermax85 sont conçues pour utiliser un diviseur de tension cinq positions facultatif. Le diviseur de tension interne offre une tension d arc réduite de 0:,.:, 30:, 40: et 50: (sortie maximale de 8 V). Une prise située à l arrière de la source de courant permet d accéder à la tension d arc réduite et aux signaux pour le transfert d arc et le démarrage plasma. Remarque : le diviseur est préréglé en usine à 50:. Pour modifier le réglage, consulter les instructions plus loin dans le présent bulletin de service sur le terrain. ATTENTION : le diviseur de tension interne fournit un maximum de 8 V dans des conditions de circuit ouvert. Il s agit d une tension de sortie fonctionnelle très basse protégée par l impédance (ELV) qui permet d éviter les risques d électrocution, les problèmes d énergie et les risques d incendie dans des conditions normales sur la prise d interface de la machine et d éviter tous ces risques en cas d une seule défaillance sur le câblage d interface de la machine. Le diviseur de tension n est pas tolérant aux pannes et les sorties ELV ne répondent pas aux exigences de sécurité de basse tension (SELV) pour le raccordement direct du matériel informatique. Bulletin de service sur le terrain

Câble d interface de machine avec panneau diviseur de tension Retrait du couvercle de la source de courant et de la barrière de composant. Couper l alimentation (OFF), débrancher le cordon d alimentation et débrancher l alimentation en gaz.. Déposer les 8 petites vis () du couvercle de la source de courant. 3. Déposer les 8 grandes vis () du couvercle de la source de courant. 4. Retirer le couvercle (3) de la source de courant. 3 5. Retirer la barrière de composant du côté du panneau d alimentation de la source de courant. Cette barrière est flexible et peut être pliée légèrement pour être enlevée. Bulletin de service sur le terrain 3

Câble d interface de machine avec panneau diviseur de tension Installation du panneau diviseur de tension avec port CPC et câbles. Fixer le panneau diviseur de tension à la droite du ventilateur de la source de courant à l aide de deux vis (075534). Passe-fil supérieur Vis (075534) Passe-fil inférieur. Retirer la fiche de plastique ronde qui couvre l ouverture CPC du panneau arrière. Prise en plastique CPC sur le panneau arrière de la source de courant 4 Bulletin de service sur le terrain

Câble d interface de machine avec panneau diviseur de tension 3. Acheminer le port CPC et les câbles au-dessus du logement du ventilateur jusqu à l ouverture du port CPC sur le panneau arrière de la source de courant. 4. Insérer le port CPC dans l ouverture du port CPC de l intérieur de la source de courant. S assurer de placer le port avec le fil vert/jaune au bas du port. Ouverture du port CPC Port CPC Vis (075534) Fil de terre vert/jaune Vis (075534) Visser pour fixer le fil de terre au boîtier du filtre à gaz. 5. Fixer le port à l aide de deux vis (075534). Deux vis suffisent si elles sont insérées à des coins opposés du port CPC. 6. Fixer le fil de terre vert/jaune au boîtier du filtre du gaz en utilisant la vis de l angle avant droit du boîtier. Note: Cette vis raccorde également un autre fil de terre au boîtier du filtre à gaz (le fil de terre de la source de courant qui se connecte de l autre côté au panneau central). Bulletin de service sur le terrain 5

Câble d interface de machine avec panneau diviseur de tension Dégagement du panneau avant de la source de courant Pour offrir un accès facile afin d assurer le branchement des câbles d interface au panneau d alimentation :. Déposer la tresse métallique du dessus de la source de courant en soulevant directement la tresse vers le haut. Cette tresse tient les deux panneaux d extrémité ensemble.. Placer soigneusement la source de courant sur le côté ventilateur pour accéder aux vis inférieures. 3. Retirer les deux vis qui fixent le panneau avant au bas de la source de courant. 4. Au moyen du tournevis plat, retirer délicatement le panneau avant au bas de la source de courant. 5. Placer la source de courant à la verticale. 6. Retirer soigneusement le panneau avant du corps de la source de courant. Le panneau avant reste fixé au corps de la source de courant et ne peut être déplacé que sur une courte distance. 6 Bulletin de service sur le terrain

Câble d interface de machine avec panneau diviseur de tension Acheminement et fixation des câbles au panneau d alimentation. Acheminer le gros câble (du port CPC) dans le passe-fil supérieur, au-dessus du diviseur de tension puis le long du côté du panneau d alimentation jusqu au connecteur (J pour les modèles CSA et CE).. Insérer le connecteur du câble dans le connecteur du panneau d alimentation (J pour les modèles CSA et CE). S assurer d aligner le fil rouge du connecteur du câble avec l inscription «RED» se trouvant sur le panneau d alimentation. 3. Acheminer le petit câble (du côté droit du panneau diviseur de tension) dans le passe-fil inférieur, au-dessus du panneau diviseur de tension puis le long du côté du panneau d alimentation jusqu au connecteur (J3 pour les modèles CSA, J33 pour les modèles CE). 4. Insérer le connecteur du câble dans le connecteur du panneau d alimentation (J3 pour les modèles CSA, J33 pour les modèles CE). S assurer d aligner le fil rouge du connecteur du câble avec l inscription «RED» se trouvant sur le panneau d alimentation. Gros câble RED J Petit câble RED J3 (CSA) J33 (CE) Bulletin de service sur le terrain 7

Câble d interface de machine avec panneau diviseur de tension Réglage du diviseur de tension cinq positions du Powermax65/85 Le diviseur de tension est préréglé en usine à 50:. Pour modifier le réglage :. Situer les commutateurs DIP du diviseur de tension, placés sur son panneau. La figure ci-dessous illustre le réglage par défaut (50:), le commutateur 4 réglé vers le haut.. Régler les commutateurs DIP à l un des paramètres suivants. 0:.: 30: 40: 50: Fixation du panneau avant à la source de courant. Placer soigneusement la source de courant sur le côté ventilateur.. Insérer soigneusement le bas du panneau avant dans le bas de la source de courant. S assurer de ne pas pincer de fils entre le panneau avant et le dissipateur thermique de la source de courant. 3. Fixer le panneau avant au bas de la source de courant à l aide des deux vis. 4. Placer la source de courant à la verticale. 5. Remettre en place la tresse métallique sur le dessus de la source de courant en l enfonçant vers le bas. Les quatre broches de la tresse s enclencheront en place dans les panneaux avant et arrière. 8 Bulletin de service sur le terrain

Câble d interface de machine avec panneau diviseur de tension Remplacement de la barrière de composant. Enfoncer soigneusement les côtés () de la barrière de composant de façon à ce qu elle fléchisse légèrement à ses parties supérieure et inférieure ().. Glisser les côtés de la barrière derrière le cadre de la source de courant (3). Faire attention de bien placer la barrière entre le cadre et les fils d alimentation du côté droit du circuit imprimé (4). 3. Plier délicatement le haut de la barrière au niveau de la perforation, de façon à ce que le haut se replie au-dessus de la partie supérieure de la source de courant. 4. Glisser la barrière vers le bas de façon à ce que le rebord inférieur entre dans le cadre de la source de courant (5). 4 3 3 3 3 5 Bulletin de service sur le terrain 9

Câble d interface de machine avec panneau diviseur de tension Remise en place du couvercle de la source de courant. Placer le couvercle (3) sur la source de courant. S assurer de ne pincer aucun fil.. Insérer les 8 petites vis () dans le couvercle de la source de courant. Serrer les vis à un couple de 7,3 kg cm. 3. Insérer les 8 grandes vis () dans le couvercle de la source de courant. Serrer les vis à un couple de 7,3 kg cm. Devant de la source de courant 3 0 Bulletin de service sur le terrain

05 Hypertherm Inc. All Rights Reserved Tous droits réservés Hypertherm and Powermax are trademarks of Hypertherm Inc. and may be registered in the United States and/or other countries. Hypertherm et Powermax sont des marques de commerce d Hypertherm Inc. qui peuvent être déposées aux États-Unis et/ou dans d autres pays. Hypertherm Inc. Hanover, NH 03755 USA 603-643-344 Tel Hypertherm Europe B.V. 4704 SE Roosendaal, Nederland 3 65 596907 Tel Hypertherm (Shanghai) Trading Co., Ltd. PR China 0005 86-558 3330 / Tel Hypertherm (S) Pte Ltd. Singapore 349567 65 6 84 489 Tel Hypertherm (India) Thermal Cutting Pvt. Ltd. Chennai, Tamil Nadu 9 0 44 834 536 Tel Hypertherm Brasil Ltda. Guarulhos, SP - Brasil 55 409 636 Tel Hypertherm México, S.A. de C.V. México, D.F. 5 55 568 809 Tel www.hypertherm.com