Instruction Sheet

Documents pareils
ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Lavatory Faucet. Instruction Manual. Questions?

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Sécurité relative aux sièges auto et aux rehausseurs

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Folio Case User s Guide

Garage Door Monitor Model 829LM

Paxton. ins Net2 desktop reader USB

R.V. Table Mounting Instructions

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

SYSTÈME JETS D AIR WISH WISH AIR JETS SYSTEM Système de massage à jets d air pour bains en polymère - Air jet massage system for polymer bathtubs

Notice Technique / Technical Manual

Contrôle d'accès Access control. Notice technique / Technical Manual

Embases pour raccordement G1/8 - G1/4

GASKET FOR TONER COLLECTION BOTTLE

Le No.1 de l économie d énergie pour patinoires.

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

DOCUMENTATION - FRANCAIS... 2

Contents Windows

Instructions Mozilla Thunderbird Page 1

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Trim Kit Installation Instruction

Fabricant. 2 terminals

DOCUMENTATION - FRANCAIS... 2

POLICY: FREE MILK PROGRAM CODE: CS-4

LE FORMAT DES RAPPORTS DU PERSONNEL DES COMMISSIONS DE DISTRICT D AMENAGEMENT FORMAT OF DISTRICT PLANNING COMMISSION STAFF REPORTS

Free filter reminders! Sign up online at: santevia.com/filterease. need help? Contact Santevia!

ICY wine cooler manual Notice du distributeur à vin. Model / Modèle : CV2T

Stainless Steel Solar Wall Light

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

Guide d'installation rapide TFM-560X YO.13

MODE D EMPLOI USER MANUAL

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

BILL 203 PROJET DE LOI 203

Table des matières QUINCAILLERIE FONCTIONNEL FUNCTIONAL HARDWARE. Clé H1 Serrure et pêne H2. Serrure à levier H4

Logitech Speaker System Z553 Setup Guide Guide d installation

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

FÉDÉRATION INTERNATIONALE DE NATATION Diving

How to Login to Career Page

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

lundi 3 août 2009 Choose your language What is Document Connection for Mac? Communautés Numériques L informatique à la portée du Grand Public

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

Monitor LRD. Table des matières

AND / ET USER GUIDE UK HARDWIRED CONTROL PANEL UK GUIDE UTILISATEUR CENTRALE D ALARME FILAIRE F

Le passé composé. C'est le passé! Tout ça c'est du passé! That's the past! All that's in the past!

86 rue Julie, Ormstown, Quebec J0S 1K0

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

GRILLE AU GAZ CB-70M & CB-105M GAS CHAR-BROILER

DOCUMENTATION MODULE BLOCKCATEGORIESCUSTOM Module crée par Prestacrea - Version : 2.0

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

Package Contents. System Requirements. Before You Begin

Quick Installation Guide TEW-AO12O

APPENDIX 6 BONUS RING FORMAT

F1 Security Requirement Check List (SRCL)

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

Dishwasher Lave-vaisselle

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Dans une agence de location immobilière...

Nouveautés printemps 2013

AVIS DE COURSE. Nom de la compétition : CHALLENGE FINN OUEST TOUR 3 Dates complètes : 14, 15 et 16 mai 2015 Lieu : Saint Pierre Quiberon

Archived Content. Contenu archivé

User guide Conference phone Konftel 100

FO-FDHB6-1 Central Heat Blower Kit for Onyx, Opel and Delta

33 inch open & closed storage Rangement à espace fermé et ouvert de 33po (83.7cm) 33 pulgadas almacenaje abierto y cerra

Practice Direction. Class Proceedings

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

Discours du Ministre Tassarajen Pillay Chedumbrum. Ministre des Technologies de l'information et de la Communication (TIC) Worshop on Dot.

3M HEPA Vacuum 497AJK. User s Guide

BLUELINEA ,00 EUR composé de actions de valeur nominale 0,20 EUR Date de création : 17/01/2006

MONTEGO 3 PERSON CUSHION GARDEN SWING WITH CANOPY ASSEMBLY INSTRUCTIONS ITEM# SC-177-2GS

RÈGLEMENT SUR LES CEINTURES DE SÉCURITÉ ET LES ENSEMBLES DE RETENUE POUR ENFANTS R.R.T.N.-O. 1990, ch. M-35

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

INDIVIDUALS AND LEGAL ENTITIES: If the dividends have not been paid yet, you may be eligible for the simplified procedure.

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

NOM ENTREPRISE. Document : Plan Qualité Spécifique du Projet / Project Specific Quality Plan

Gestion des prestations Volontaire

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

JSIam Introduction talk. Philippe Gradt. Grenoble, March 6th 2015


The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Editing and managing Systems engineering processes at Snecma

STATUS VIS-Av -VIS THE HOST STATE OF A DIPLOMATIC ENVOY TO THE UNITED NATIONS (COMMONWEALTH OF DOMINICA v. SWITZERLAND)

Stratégie DataCenters Société Générale Enjeux, objectifs et rôle d un partenaire comme Data4

ENGLISH 4 FRANÇAIS 6 ESPAÑOL 8

INTERNATIONAL CONSULTANT & SUPPLIERS TO THE WINE & SPIRITS TRADE

THE LAW SOCIETY OF UPPER CANADA BY-LAW 19 [HANDLING OF MONEY AND OTHER PROPERTY] MOTION TO BE MOVED AT THE MEETING OF CONVOCATION ON JANUARY 24, 2002

Le Tour de Bretagne à la Voile est une épreuve de catégorie 3 des RSO. En cas de traduction de cet avis de course, le texte français prévaudra

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

GAME CONTENTS CONTENU DU JEU OBJECT OF THE GAME BUT DU JEU

Propriétés de la matière. Material properties. Sonde de pression Pressure probe. Ref : Français p 1. English p 3.

FCM 2015 ANNUAL CONFERENCE AND TRADE SHOW Terms and Conditions for Delegates and Companions Shaw Convention Centre, Edmonton, AB June 5 8, 2015

À l'approche du festival MUTEK 2015, nous vous contactons pour vous faire part de quelques informations importantes.

Laboratory accredited by the French Home Office (official gazette date February 5 th, 1959, modified) Valid five years from August 27 th, 2013

Transcription:

1.45 mm Instruction 16026908 Sheet Description: LP Gas Conversion Kit Repair Part Number: 649P3 Kit includes: 2206860 Quantity Part number Description 1 -----------------------------------------------40097101 --------------------------------------- Block Open Plug 1 -----------------------------------------------40097301 --------------------------------------- Burner Orifice Spud (1.45 mm) 1 -----------------------------------------------40097004 --------------------------------------- Conversion Plate 1 -----------------------------------------------40096701 --------------------------------------- Valve Converted to L.P. Gas Sticker (English) 1 -----------------------------------------------40096901 --------------------------------------- Valve Converted to L.P. Gas Sticker (French) 1 -----------------------------------------------40096801 --------------------------------------- Valve Converted to L.P. Gas Sticker (Spanish) 2 -----------------------------------------------40096602 --------------------------------------- L.P. Gas Stickers (English) 2 -----------------------------------------------40096606 --------------------------------------- L.P. Gas Stickers (French) 1 -----------------------------------------------40096604 --------------------------------------- L.P. Gas Sticker (Spanish) 1 -----------------------------------------------16026908 --------------------------------------- Instructions Block - Open Plug Burner Orifice Spud! WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority having jurisdiction. The information in these instructions must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit. THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CSA-B149.1 INSTALLATION CODE.! WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: Disconnect electric power to the dryer before servicing. Close equipment shut-off valve to gas dryer before servicing. Never start the dryer with any guards/panels removed. Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. 16026908 2006 Maytag Services Page 1 of 5

Important Note: For proper operation at elevations above 4500 feet (1370 m) one of the following orifice sizes must be used to ensure complete combustion. These parts are not included in standard kits. See Table below for proper orifice size. Altitude Orifice Size Part Number Feet m Number Inches mm 3000 915 55 0.0520 1.32 40097201 8000 2440 56 0.0465 1.18 40098001 GAS Input 22,500 BTU/HR When converting the dryer gas valve to L.P. gas, be sure the incoming gas supply line is equipped with a pressure regulator (located ahead of the dryer) that will maintain the gas supply to the dryer at 10 ± 1.5 inches (25.4 ± 3.81 cm) water column pressure. Remove pressure tap pipe plug and check gas pressure by connecting a U tube manometer (or similar pressure gauge) to the pressure tap. Manometer 10 + 1.5" (25.4 + 3.81 cm) Equipment shut-off valve within 6' (1.8 m) of dryer. 1/8" NPT pipe plug (for checking inlet gas pressure) Install the No. 649P3 Kit as follows: 1. Disconnect electrical power to the machine. 2. Turn the equipment shut-off valve handle to the closed position (if so equipped). If shut-off valve is not present, turn off dryer gas supply at the appliance. (For models built after JULY 2005) (For models built before JULY 2005) 3(a) Use a plastic putty knife to depress the locking 3. Remove service access panel by removing two clips between the Top Cover and Front Panel. access panel screws. Repeat for both sides, and then lift Top Cover. 3(b) Disconnect wiring from the Door Switch. 3(c) Remove two screws (1 each side) from the back flange of the front panel. Front Panel Access screws Service Access Panel screws Page 2 of 5 2006 Maytag Services 16026908

4. Disconnect igniter wires at quick disconnect blocks. 4 5 Burner Orifice Spud Shut-Off Valve Vent Screw Ignitor Quick Disconnect Block Air Shutter Adjustment Screw Burner Housing Burner Tube 1-3 Air Shutter Hex Head Screw Apply No. 40096701 Valve Converted Sticker Here 1/ 8" Pipe Plug (For checking manifold pressure) 5. Remove hex head screw holding burner tube and igniter in place. 6. Carefully move burner tube toward rear of dryer, far enough to permit removal of burner orifice spud from gas valve. NOTE: Tab on burner tube may have to be removed from slot in burner housing to obtain enough clearance. 7. Turn the burner orifice spud out of gas valve and install No. 40097301 L.P. Burner Orifice Spud (metal stamped 1.45 mm). Torque new burner orifice spud to 30 inch-pounds (3.4 N-m). 8. Reinstall burner tube, tighten hex head screw firmly and reconnect igniter leads. 9. Remove the vent screw, and install No. 40097101 Block-Open Plug. 10. Install No. 40096701 Valve Converted to L.P. Gas Sticker to top side of gas valve, so it covers the gas valve part number. 11. In Canada, early models (with access door) do not need to use the two 40096602 L.P. Gas Stickers. Sign and date each of the two No. 40096602 L.P. Gas Stickers. Install one of the 40096602 L.P. Gas Stickers over the top three lines of the old sticker on rear of cabinet, then place the second sticker over the top three lines of the old sticker located on backside of access door or lower access panel. Apply No. 40096602 L.P. Sticker Here 16026908 2006 Maytag Services Page 3 of 5

12. Apply the No. 40097002 Conversion Plate to the inside of the loading door opening, or over the top of any previously applied conversion plate. Nameplate Apply No. 40097002 conversion plate here 13. Turn the equipment shut-off valve handle to the open position, and connect electrical service. 14. Check gas valve pressure as follows: a. Remove pressure tap pipe plug. b. Connect a U tube manometer (or similar pressure gauge) to the pressure tap. Shut-Off Valve Air Shutter Adjustment Screw Manometer Air Shutter 10 + 1.5" (25.4 + 3.81 cm) 1/ 8" Pipe Plug (For checking manifold pressure) c. Start dryer, pressure should be 10 ± 1.5 inches. d. Stop dryer and remove U tube and reinstall the pressure tap pipe plug.! WARNING To reduce the risk of fire or explosion, check pipe connection for gas leaks by using a soapy solution. DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS! 15. Check the gas line connection for gas leaks with a non-corrosive leak detection fluid. 16. Make sure the dryer conversion has been completed. Recheck the following: Installed correct orifice spud (40097301, 1.45 mm, for standard installation), see Step 7. Installed block-open plug, see Step 9. Gas valve pressure must be 10 ± 1.5 inches (25.4 ± 3.8 cm), see Step 14. Installed four stickers, see Steps 10, 11, and 12. Page 4 of 5 2006 Maytag Services 16026908

17. For models built before JULY 2005: Start the dryer and observe the burner flame. Adjust the air shutter to obtain a soft, uniform blue flame. (A lazy, yellow tipped flame indicates lack of air. A harsh, roaring, very blue flame indicates too much air.) Adjust the air shutter as follows: Loosen the air shutter lockscrew. Turn the air shutter to the left to get a luminous yellow tipped flame, then turn it back slowly to the right to obtain a steady soft blue flame. The air shutter should be adjusted to a gap of approximately 5/16 inches (8 mm) to 3/8 inches (9.5 mm). After the air shutter is adjusted for the proper flame, tighten the air shutter lockscrew securely. Be sure and observe at least two complete ignition and burn cycles before reinstalling the access door or lower access panel. Reinstall the access door or lower access panel. For models built after JULY 2005): The dryer cannot be run with the front panel removed. Adjust the air shutter as follows: Loosen the air shutter lockscrew. The air shutter should be adjusted to a gap of approximately 5/16 inches (8 mm) to 3/8 inches (9.5 mm). Tighten the air shutter lockscrew securely. Reinstall the access door or lower access panel.! WARNING For personal safety, access door or lower access panel must be in place during normal operation. 16026908 2006 Maytag Services Page 5 of 5

1.45 mm Feuille 16026908 d instructions Description : Trousse de conversion au GPL Pièce de rechange numéro : 649P3 La trousse inclut : 2206860 Quantité Numéro de pièce Description 1 -----------------------------------------------40097101 --------------------------------------- Bloc Bouchon ouvert 1 -----------------------------------------------40097301 --------------------------------------- Tête d injecteur à filetage extérieur du brûleur (1,45 mm) 1 -----------------------------------------------40097004 --------------------------------------- Plaque de conversion 1 -----------------------------------------------40096701 --------------------------------------- Soupape convertie vers Autocollant de GPL (Anglais) 1 -----------------------------------------------40096901 --------------------------------------- Soupape convertie vers Autocollant de GPL (Français) 1 -----------------------------------------------40096801 --------------------------------------- Soupape convertie vers Autocollant de GPL (Espagnol) 2 -----------------------------------------------40096602 --------------------------------------- Autocollants de GPL (Anglais) 2 -----------------------------------------------40096606 --------------------------------------- Autocollants de GPL (Français) 1 -----------------------------------------------40096604 --------------------------------------- Autocollant de GPL (Espagnol) 1 -----------------------------------------------16026908 --------------------------------------- Instructions Bloc Block Bouchon - Open ouvert Plug Tête Burner d injecteur Orifice à Spud filetage extérieur du brûleur! AVERTISSEMENT WARNING Cette trousse de conversion doit être installée par une agence de service qualifiée, selon les instructions fournies par le fabricant et en respectant les codes et exigences des autorités compétentes. Les informations données dans ces instructions doivent être respectées afin de réduire les risques d incendie ou d explosion ou pour éviter des dommages à la propriété, des blessures ou la mort. L agence de service qualifiée est responsable de l installation adéquate de cette trousse. L installation n est pas correcte et complète tant que le fonctionnement de l appareil converti n'est pas vérifié tel qu il est spécifié dans les instructions du fabricant fournies avec la trousse. EFFECTUER LA CONVERSION SELON LES EXIGENCES DES AUTORITÉS PROVINCIALES COMPÉTENTES ET SELON LES EXIGENCES DES PARTIES CSA-B149.1 DU CODE D INSTALLATION.! AVERTISSEMENT WARNING Afin de réduire les risques de décharge électrique, d incendie, d'explosion, de blessures graves ou de mort : Débrancher l alimentation électrique de la sécheuse, avant d'effectuer l entretien. Fermer le robinet d arrêt de l'équipement vers la sécheuse au gaz avant d'effectuer l'entretien. Ne jamais démarrer la sécheuse si toute protection ou tout panneau a été enlevé. Si des prises de terre sont enlevées pendant l entretien, elles doivent être rebranchées pour assurer la mise à la terre correcte de la sécheuse. 16026908 2006 Maytag Services Page 1 de 5

Remarque importante : Pour obtenir un fonctionnement adéquat à plus de 1370 m (4500 pi), utiliser une des tailles d orifice suivantes afin d assurer une combustion complète. Ces pièces ne sont pas incluses dans les trousses standard. Voir le tableau ci-dessous pour connaître les tailles d orifice qui conviennent. Altitude Taille d orifice Numéro de pièce Pieds m Numéro Pouces mm 3000 915 55 0,0520 1,32 40097201 8000 2440 56 0,0465 1,18 40098001 Entrée de GAZ 22 500 BTU/H Lors de la conversion d'une soupape à gaz pour sécheuse vers le GPL, s assurer que l'alimentation de la conduite de gaz est équipée d'un régulateur de pression (situé à l avant la sécheuse) qui maintiendra l alimentation de colonne de pression d'eau de 25,4 cm ±3,81 cm (10 ±1,5 po) vers la sécheuse. Enlever le bouchon du tuyau du robinet de pression et vérifier la pression du gaz en connectant un manomètre avec tube en «U» (ou autre manomètre semblable) au robinet de pression. 25,4 ±3,81 cm (10 ±1,5 po) Installer la trousse n o 649P3 comme suit : 1. Débrancher l alimentation électrique de la machine. 2. Tourner la poignée du robinet d'arrêt à la position fermée (le cas échéant). Si aucun robinet d arrêt n est présent, couper l alimentation en gaz au niveau de l appareil. (Seulement pour les modèles (Seulement pour les modèles construits après JUILLET 2005) construits avant JUILLET 2005) 3(a). Utiliser un couteau à mastic en plastique pour 3. Enlever le panneau d'accès de service en enfoncer les attaches de verrouillage entre le dévissant les deux vis du panneau d accès. dessus et le panneau avant. 3(b). Débrancher le câblage du contacteur de porte. 3(c). Enlever les deux vis (1 de chaque côté) du rebord arrière du panneau avant. Vis d accès Front Panel du panneau Access avant screws Service Vis du panneau Access d accès Panel screws de service Page 2 de 5 2006 Maytag Services 16026908

4. Débrancher les fils de l allumeur électrique au niveau des blocs de débranchement rapide. 5. Enlever les vis à tête hexagonale qui maintiennent le tube du brûleur et de l'allumeur électrique. 6. Déplacer avec précaution le tube du brûleur vers l'arrière de la sécheuse, à une distance suffisante pour pouvoir enlever de la soupape à gaz la tête d injecteur à filetage extérieur du brûleur. REMARQUE : L onglet du tube du brûleur pourrait avoir été enlevé de la fente de l enveloppe du brûleur pour obtenir un dégagement suffisant. 7. Dévisser la tête d injecteur à filetage extérieur du brûleur de la soupape de gaz et installer la tête d injecteur à filetage extérieur du brûleur n o 40097301 PL (métal marqué à 1,45 mm). Serrer la nouvelle tête d injecteur à filetage extérieur à 3,4 Nm (30 po/lb). 8. Réinstaller le tube du brûleur, serrer fermement la vis à tête hexagonale et rebrancher les fils de l allumeur électrique. 9. Enlever les vis de l évent et installer le bloc - bouchon ouvert n o 40097101. 10. Apposer l autocollant n o 40096701 «Soupape convertie au GPL» sur le côté supérieur de la soupape de gaz, de manière à recouvrir son numéro de série. 11. Au Canada, les premiers modèles (avec porte d accès) n ont pas besoin des deux autocollants pour le gaz 40096602 GPL. Signer et dater chaque autocollant pour le gaz n o 40096602 GPL. Installer un des autocollants pour le gaz 40096602 GPL par-dessus les trois lignes supérieures de l'ancien autocollant, situé à l'arrière de l'armoire, et placer le deuxième autocollant par-dessus les trois lignes supérieures de l'ancien autocollant situé à l'arrière de la porte d'accès ou du panneau d'accès inférieur. Appliquer l autocollant n o 40096602 GPL ici 16026908 2006 Maytag Services Page 3 de 5

12. Apposer la plaque de conversion n o 40097002 à l intérieur de l ouverture de la porte de chargement, ou pardessus toute plaque de conversion apposée précédemment. Plaque-marque Appliquer la plaque de conversion n o 40097002 ici 13. Tourner la poignée du robinet d'arrêt à la position ouverte et brancher l alimentation électrique. 14. Vérifier comme suit la pression de la soupape de gaz : a. Enlever le bouchon du tuyau du robinet de pression. b. Raccorder un manomètre à tube en «U» (ou une jauge similaire) au robinet de pression. Robinet d arrêt Vis de réglage du registre Manomètre Registre 25,4 ±3,81 cm (10 ±1,5 po) Bouchon pour tuyau de 1/8 po (pour la vérification de la pression du collecteur) c. Démarrer la sécheuse, la pression devrait être de 10 ±1,5 po. d. Arrêter la sécheuse, enlever le tube en «U» et réinstaller le bouchon du tuyau du robinet de pression.! AVERTISSEMENT WARNING Afin de réduire les risques d'incendie ou d'explosion, utiliser une solution savonneuse pour vérifier que le raccord du tuyau ne présente aucune fuite de gaz. NE PAS UTILISER UNE FLAMME NUE POUR VÉRIFIER LA PRÉSENCE DE FUITES DE GAZ! 15. Utiliser un fluide non corrosif de détection de fuite pour vérifier que les raccords de conduite de gaz ne présentent pas de fuites. 16. S assurer que la conversion de la sécheuse est bien terminée. Vérifier encore une fois ce qui suit : Installation de la bonne tête d injecteur à filetage extérieur (40097301, 1,45 mm, pour installation standard), voir l étape 7. Installation du bloc - bouchon ouvert, voir l'étape 9. La pression de la soupape de gaz doit être de 25,4 ±3,81 cm (10 ±1,5 po), voir l étape 14. Installation des quatre autocollants, voir les étapes 10, 11 et 12. Page 4 de 5 2006 Maytag Services 16026908

17 Seulement pour les modèles construits avant JUILLET 2005: Démarrer la sécheuse et observer la flamme du brûleur. Ajuster le registre pour obtenir une flamme douce et uniforme. (Une flamme molle aux embouts jaunes indique un manque d'air. Une flamme rude et rugissante, très bleue, indique un surplus d'air.) Ajuster le registre comme suit: Desserrer la vis de calage du registre. Fermer le registre sur la gauche pour obtenir une flamme lumineuse au bout jaune, puis tourner pour obtenir une flamme bleue et stable. Après avoir réglé le registre pour obtenir la flamme voulue, bien resserrer la vis de calage du registre. Effectuer et observer au moins deux cycle complets d'allumage et de brûlage avant de réinstaller la porte d'accès ou le panneau d'accès inférieur. Réinstaller la porte d accès ou le panneau d accès inférieur. Seulement pour les modèles construits après JUILLET 2005: La sécheuse ne peut fonctionner lorsque son panneau avant est enlevé. Ajuster le registre comme suit: Desserrer la vis de calage du registre. Le registre doit être ajusté pour un écart d environ 12,5 mm (1/2 po). Bien resserrer la vis de calage du registre. Réinstaller la porte d accès ou le panneau d accès inférieur.! AVERTISSEMENT WARNING Pour des raisons de sécurité personnelle, la porte d accès ou le panneau d accès inférieur doivent être en place lors d une utilisation normale. 16026908 2006 Maytag Services Page 5 de 5