Model R8800. Instruction Manual. Voltage/Current Calibrator. reedinstruments

Documents pareils
PVCHECK Rel /11/12

SERIE TS-770 SYSTEME CONFERENCE

Master4Light. Caractérisation Optique et Electrique des Sources Lumineuses. Equipement 2-en-1 : source de courant et spectrophotomètre

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Logitech Speaker System Z553 Setup Guide Guide d installation

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Guide d'installation rapide TFM-560X YO.13

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Garage Door Monitor Model 829LM

Mesure chimique Conductimétrie. Chemical measurement Conductimetry. Conductimètre CTM Initio. Initio CTM conductimeter. Ref :

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Guide de l utilisateur. Calibreur de Courant / Voltage Modèle A

Paxton. ins Net2 desktop reader USB

Mesure. Multimètre écologique J2. Réf : Français p 1. Version : 0110

Contents Windows

Once the installation is complete, you can delete the temporary Zip files..

Fonctions intégrées. Nouvelles solutions universelles & système de communication

Notice Technique / Technical Manual

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Tutoriel de formation SurveyMonkey

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Lavatory Faucet. Instruction Manual. Questions?

Fabricant. 2 terminals

Exemple PLS avec SAS

Instructions Mozilla Thunderbird Page 1

Contrôle d'accès Access control. Notice technique / Technical Manual

WEB page builder and server for SCADA applications usable from a WEB navigator

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

Le No.1 de l économie d énergie pour patinoires.

ARCHOS Activity Tracker

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

MANUEL D INSTRUCTION

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

DOCUMENTATION - FRANCAIS... 2

DOCUMENTATION - FRANCAIS... 2

AMC 120 Amplificateur casque

Le Cloud Computing est-il l ennemi de la Sécurité?

MODULES ÉLECTRIQUES. - systèmes électriques DC - onduleurs - convertisseurs - interrupteurs statiques. Notre alimentation Votre confiance

PARIS ROISSY CHARLES DE GAULLE

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

How to Login to Career Page

Moteur DC: Comment faire varier sa vitesse?

Exercices sur SQL server 2000

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

Package Contents. System Requirements. Before You Begin

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Natixis Asset Management Response to the European Commission Green Paper on shadow banking

Application Form/ Formulaire de demande

POLICY: FREE MILK PROGRAM CODE: CS-4

Folio Case User s Guide

Archived Content. Contenu archivé

MANUEL MARKETING ET SURVIE PDF

Stainless Steel Solar Wall Light

«39 years of experience» ( )

AUDIT COMMITTEE: TERMS OF REFERENCE

ARP-090G / ARP-090K NOTICE D'EMPLOI INSTRUCTION MANUAL

Spécial Catégorie 6 Patch Cords

MB5 MIMO. Beamforming Test System User Manual

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Devoir Data WareHouse

Z-Axis Compliance Device Compliance en z

ARDUINO DOSSIER RESSOURCE POUR LA CLASSE

RAPID Prenez le contrôle sur vos données

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

Multichronomètre SA10 Présentation générale

ad notam Applications et Solutions

Thermomètre portable Type CTH6500

Embases pour raccordement G1/8 - G1/4

User guide Conference phone Konftel 100

Appointment or Deployment of Alternates Regulations. Règlement sur la nomination ou la mutation de remplaçants CONSOLIDATION CODIFICATION

FĖDĖRATION CROATE D'ESCRIME Trg sportova 11, Zagreb Phone: Fax: crofencing@hi.htnet.hr

GASKET FOR TONER COLLECTION BOTTLE

Surveillance de Scripts LUA et de réception d EVENT. avec LoriotPro Extended & Broadcast Edition

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

Le passé composé. C'est le passé! Tout ça c'est du passé! That's the past! All that's in the past!

fullprotect inside EOLE SPEie RS E-SPEie V-0.6A-RS 1.0 revision Protection environnement Datasheet édition française

Laboratory accredited by the French Home Office (official gazette date February 5 th, 1959, modified) Valid five years from August 27 th, 2013



GAME CONTENTS CONTENU DU JEU OBJECT OF THE GAME BUT DU JEU

If you understand the roles nouns (and their accompanying baggage) play in a sentence...

Manuel d utilisation. Digital Multimètre. Extech 410

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.

CEST POUR MIEUX PLACER MES PDF

Génération de code binaire pour application multimedia : une approche au vol

1-Introduction 2. 2-Installation de JBPM 3. 2-JBPM en action.7

Plan Vert de l industrie touristique montréalaise 21 février 2014

AUTUMN/WINTER PARIS COLLECTION

Lesson Plan Physical Descriptions. belle vieille grande petite grosse laide mignonne jolie. beau vieux grand petit gros laid mignon

Logitech Wireless Performance Combo MX800 Setup Guide Guide d installation

Comment consolider des données

Elégance et raffinement Elegance & sophistication

Discours du Ministre Tassarajen Pillay Chedumbrum. Ministre des Technologies de l'information et de la Communication (TIC) Worshop on Dot.

Sécurité relative aux sièges auto et aux rehausseurs

Notice d emploi Sonomètre PCE-353

Transcription:

Model R8800 Voltage/Current Calibrator Instruction Manual reedinstruments www com

Table of Contents Features... 3 Specifications...3-4 Operating Instructions...5-6 Current Source... 5 Current Measurement... 5 Two-Wire Loop Power and Current Measurement... 6 DC mv Source... 6 Battery Replacement... 6 For service on this or any other REED product or information on other REED products, contact REED Instruments at info@reedinstruments.com www com 2

Features Provides the quality and accuracy of a handheld calibrator Able to power or measure a two-wire current loop Provides a precise current and DC mv source Calibrates and measures process signals Measures Current signals Adjustable 0-24mA current source Adjustable -199.9mV to +199.9mV DCV source Drives loads up to 500 ohms Specifications Display: LCD, max display counts 1999 Sampling Time: Operating Temperature: Operating Humidity: Power Supply: Dimensions: Weight: Approx. 0.4 second 0 to 50 C (32 to 122 F) < 70% RH DC9V 150 x 70 x 40 mm 232g (including battery) www com 3

Electrical Specifications Specifications are tested under the environment RF Field Strength less than 3V/M & frequency less than the 30 MHz only. Current Source Range Display Resolution Accuracy 0-19.99mA 0.01mA ± (0.25%FS+1d) 0-24mA 0.1mA ± (0.5%FS+1d) Output 0 to 24mA current for loads up to 500 ohms. Output > 20mA current for loads up to 400 ohms. FS: Full Scale Current Measurement Range Display Resolution Accuracy 0-19.99mA 0.01mA ±(0.25%FS+1d) 0-24mA 0.1mA ±(0.5%FS+1d) FS: Full Scale Two-Wire Loop Power and Current Measurement Range Display Resolution Accuracy 0-19.99mA 0.01mA ±(0.25%FS+1d) 0-24mA 0.1mA ±(0.5%FS+1d) Provides power DC 12V ±2V to the loop and measures current. FS: Full Scale DC mv Source Range Display Resolution Accuracy -199.9mV to +199.9mV 0.1mV ±(0.25%FS+1d) Output measured load impedance should >1K ohms. FS: Full Scale www com 4

Operating Instructions Current Source 1. Insert the black test lead banana plug into the negative (COM) jack and the red test lead banana plug into the positive (mv-ma) jack. 2. Set the function switch to the "ma source" position. 3. Press the "0~19.9mA" button for a 0.01mA display resolution (max display is 19.99mA); press the "0~24mA" button for a 0.1mA display resolution. 4. Adjust the "CAL ADJUST" knob to match the current output display value. Current Measurement 1. Insert the black test lead banana plug into the negative (COM) jack and the red test lead banana plug into the positive (mv-ma) jack. 2. Set the function switch to the "ma measure" position. 3. Press the "0~19.9mA" button for a 0.01mA display resolution (max display is 19.99mA); press the "0~24mA" button for a 0.1mA display resolution. 4. Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current. 5. Touch the black test probe tip to the negative side of the circuit, and touch the red test probe tip to the positive side of the circuit. Read the current value in the display. www com 5

Two-Wire Loop Power and Current Measurement 1. Insert the black test lead banana plug into the negative (COM) jack and the red test lead banana plug into the positive (mv-ma) jack. 2. Set the function switch to the "Power/mA measure" position. 3. Press the "0~19.9mA" button for a 0.01mA display resolution (max display is 19.99mA); press the "0~24mA" button for a 0.1mA display resolution. 4. Open up the circuit that is going to be measured and connect the red test probe and the black test probe securely in series with the load in which the current is to be measured. DC mv Source 1. Insert the black test lead banana plug into the negative (COM) jack and the red test lead banana plug into the positive (mv-ma) jack. 2. Set the function switch to the "mv source" position. 3. Adjust the "CAL ADJUST" to generate voltage (mv) to match the output display value. Battery Replacement When the batteries become exhausted or drop below the operating voltage, "BAT" will appear in the left-hand side of the LCD display. 1. Disconnect the test leads from the meter. 2. Open the battery door by loosening the screw using a Phillips head screwdriver. 3. Insert the battery into battery holder, observing the correct polarity. 4. Put the battery door back in place. Secure with the two screws. www com 6

Modèle R8800 Calibrateur de courant / tension Manuel d utilisation reedinstruments www com

Table des Matières Caractéristiques... 3 Spécifications...3-4 Mode d emploi...5-6 Source de courant... 5 Mesure de courant... 5 Alimentation avec boucle deux fils et mesure de courant... 6 Source de tension mv en courant continu... 6 Remplacement de la pile... 6 Pour service ou information sur ce produit ou tout autre produit REED, communiquez avec REED Instruments à l adresse info@reedinstruments.com www com 2

Caractéristiques Assure la qualité et la précision d un calibrateur portable Capable d alimenter ou de mesurer une boucle de courant deux fils Pourvoit un courant précis et une source de tension mv en courant continu Étalonne et mesure les signaux de processus Mesure les signaux de courant Source de courant réglable de 0 à 24 ma Source Vc.c. réglable de -199.9 mv à +199.9 mv Active des charges jusqu à 500 ohms Spécifications Affichage: Temps d échantillonnage: Temp. de fonctionnement: Humidité de fonctionnement: Alimentation: Dimensions: Poids: ACL, max. de 1999 comptes Environ 0,4 seconde 0 à 50 C (32 à 122 F) < 70 % HR 9 V c.c. 150 x 70 x 40 mm 232 g (pile comprise) www com 3

Spécifications électriques Les spécifications ont été mises à l essai conformément à la norme environnementale sur l intensité du champ de radiofréquences, lesquelles sont inférieures à 3 V/M et la fréquence inférieure à 30 MHz seulement. Source de courant Gamme Résolution d affichage Précision 0-19.99mA 0.01mA ± (0.25%p.e.+1chi) 0-24mA 0.1mA ± (0.5%p.e.+1chi) Courant de sortie de 0 à 24 ma pour des charges jusqu à 500 ohms. Courant de sortie > 20 ma pour des charges jusqu à 400 ohms. "p.e": de la pleine échelle. Mesure de courant Gamme Résolution d affichage Précision 0-19.99mA 0.01mA ±(0.25%FS+1chi) 0-24mA 0.1mA ±(0.5%FS+1chi) "p.e": de la pleine échelle Alimentation avec boucle deux fils et mesure de courant Gamme Résolution d affichage Précision 0-19.99mA 0.01mA ±(0.25%FS+1chi) 0-24mA 0.1mA ±(0.5%FS+1chi) Pourvoit une alimentation c.c. de 12 V ± 2 V à la boucle et mesure le courant. "p.e": de la pleine échelle. Source de tension mv en courant continu Gamme Résolution d affichage Précision -199.9mV to +199.9mV 0.1mV ±(0.25%FS+1chi) L impédance de charge mesurée à la sortie devrait être > 1000 ohms. "p.e": de la pleine échelle. www com 4

Mode d emploi Source de courant 1. Insérez la fiche banane du fil d essai noir dans la prise négative (COM) et la fiche banane du fil d essai rouge dans la prise positive (mv-ma). 2. Réglez le sélecteur de fonctions à la position "ma source". 3. Appuyez sur le bouton "0~19.9 ma" pour une résolution d affichage de 0.01 ma (l affichage maximal est de 19.99 ma); appuyez sur le bouton "0~24 ma" pour une résolution d affichage de 0.1 ma. 4. Ajustez le bouton "CAL ADJUST" pour correspondre à la valeur d affichage du courant de sortie. Mesure de courant 1. Insérez la fiche banane du fil d essai noir dans la prise négative (COM) et la fiche banane du fil d essai rouge dans la prise positive (mv-ma). 2. Réglez le sélecteur de fonctions à la position "ma measure". 3. Appuyez sur le bouton "0~19.9 ma" pour une résolution d affichage de 0.01 ma (l affichage maximal est de 19.99 ma); appuyez sur le bouton "0~24 ma" pour une résolution d affichage de 0.1 ma. 4. Coupez l alimentation électrique du circuit à l essai, puis ouvrez le circuit au point là où vous désirez mesurer le courant. 5. Touchez la pointe de la sonde d essai noire sur le côté négatif du circuit, et touchez la pointe de la sonde d essai rouge sur le côté positif du circuit. Lisez la valeur de courant sur l écran. www com 5

Alimentation avec boucle deux fils et mesure de courant 1. Insérez la fiche banane du fil d essai noir dans la prise négative (COM) et la fiche banane du fil d essai rouge dans la prise positive (mv-ma). 2. Réglez le sélecteur de fonctions à la position "Power/mA measure". 3. Appuyez sur le bouton "0~19.9 ma" pour une résolution d affichage de 0.01 ma (l affichage maximal est de 19.99 ma); appuyez sur le bouton "0~24 ma" pour une résolution d affichage de 0.1 ma. 4. Ouvrez le circuit qui va être mesuré et raccordez la sonde d essai rouge et la sonde d essai noire de façon sécuritaire en série avec la charge dans laquelle on désire mesurer le courant. Source de tension mv en courant continu 1. Insérez la fiche banane du fil d essai noir dans la prise négative (COM) et la fiche banane du fil d essai rouge dans la prise positive (mv-ma). 2. Réglez le sélecteur de fonctions à la position "mv source". 3. Ajustez le bouton "CAL ADJUST" pour générer la tension (mv) pour correspondre à la valeur d affichage de sortie. Remplacement de la pile Lorsque la capacité des piles est épuisée ou tombe en dessous de la tension de fonctionnement, le mot "BAT" apparaîtra sur la partie gauche de l affichage ACL. La pile devrait être remplacée. 1. Débranchez les fils d essai du compteur. 2. Ouvrez la porte du compartiment de la pile en dévissant les vis à l aide d un tournevis à tête cylindrique cruciforme. 3. Insérez la pile dans le compartiment en respectant les polarités. 4. Remettez en place la porte du compartiment. Fixez-la solidement avec les deux vis. www com 6