Heavy Duty Meter Model 407026 USER GUIDE



Documents pareils
USER GUIDE. Video Borescope. Model BR100

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Manual. Digital Sound Level Meter. Model

Lavatory Faucet. Instruction Manual. Questions?

Paxton. ins Net2 desktop reader USB

Package Contents. System Requirements. Before You Begin

Notice Technique / Technical Manual

Warning: Failure to follow these warnings could result in property damage, or personal injury.

AUTO ER ADAPT ER SPECIAL USE WARNING

Guide d'installation rapide TFM-560X YO.13

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Le No.1 de l économie d énergie pour patinoires.

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Folio Case User s Guide

Contrôle d'accès Access control. Notice technique / Technical Manual

Quick start guide. HTL1170B

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Instructions Mozilla Thunderbird Page 1

worldwide limited warranty and technical support

PAR RINOX INC BY RINOX INC PROGRAMME D INSTALLATEUR INSTALLER PROGRAM

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Contents Windows

J. Nexera Distribution assembly instructions consignes d assemblage instrucciones de ensamblaje

SERVEUR DÉDIÉ DOCUMENTATION

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Gestion des prestations Volontaire

Garage Door Monitor Model 829LM

LG Electronics, Inc. Display Limited Warranty - USA

Fabricant. 2 terminals

Utiliser une WebCam. Micro-ordinateurs, informations, idées, trucs et astuces

Archived Content. Contenu archivé

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

Quick Setup Guide Guide de configuration rapide. Tablet Device SGPT12 Series Tablette électronique Série SGPT12

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

POLICY: FREE MILK PROGRAM CODE: CS-4

WEB page builder and server for SCADA applications usable from a WEB navigator

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

Le Cloud Computing est-il l ennemi de la Sécurité?

Owner's Manual RSB-1410

Trim Kit Installation Instruction

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

Application Form/ Formulaire de demande

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

Monitor LRD. Table des matières

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

Guide d installation Deco Drain inc. DD200

Quick Installation Guide TEW-AO12O

PVCHECK Rel /11/12

DOCUMENTATION MODULE BLOCKCATEGORIESCUSTOM Module crée par Prestacrea - Version : 2.0

Quick Installation Guide TW100-BRV304

USB 598. Quick Start Guide (Windows) Guide de démarrage rapide (Windows) USB Modem. Modem USB.

DOCUMENTATION - FRANCAIS... 2

ENGLISH 4 FRANÇAIS 6 ESPAÑOL 8

PRESENTATION REMOTE TÉLÉCOMMANDE DE PRÉSENTATION. User Guide Manuel de l utilisateur

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

How to Login to Career Page

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

Logitech Speaker System Z553 Setup Guide Guide d installation

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

Practice Direction. Class Proceedings

Principe de TrueCrypt. Créer un volume pour TrueCrypt

DOCUMENTATION - FRANCAIS... 2

I. COORDONNÉES PERSONNELLES / PERSONAL DATA

Quick Installation Guide TBW-106UB H/W: V1

Electronic Locking User Guide

RAPID Prenez le contrôle sur vos données

Nouveautés printemps 2013

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

Contrôle d accès Access control MOD-TCPIP-AI. Notice technique / Technical Manual

ETABLISSEMENT D ENSEIGNEMENT OU ORGANISME DE FORMATION / UNIVERSITY OR COLLEGE:

86 rue Julie, Ormstown, Quebec J0S 1K0

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

KitchenAid Blender_ War_r_anty for_ the 50 United States, the Distr_ict of Columbia, Puer_to Rico, and Canada

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

OUVRIR UN COMPTE CLIENT PRIVÉ

Once the installation is complete, you can delete the temporary Zip files..

FCM 2015 ANNUAL CONFERENCE AND TRADE SHOW Terms and Conditions for Delegates and Companions Shaw Convention Centre, Edmonton, AB June 5 8, 2015

Surveillance de Scripts LUA et de réception d EVENT. avec LoriotPro Extended & Broadcast Edition

Master4Light. Caractérisation Optique et Electrique des Sources Lumineuses. Equipement 2-en-1 : source de courant et spectrophotomètre

Quick Installation Guide TV-IP400 TV-IP400W

Academic Project. B2- Web Development. Resit Project. Version 1.0 Last update: 24/05/2013 Use: Students Author: Samuel CUELLA

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

12, Chemin de la Forge L Islet (Québec) G0R 1X0 CANADA

AND / ET USER GUIDE UK HARDWIRED CONTROL PANEL UK GUIDE UTILISATEUR CENTRALE D ALARME FILAIRE F

Adeunis-RF Softwares. Stand-Alone configuration Manager V2. User guide version V1 FRANCAIS ENGLISH

THE EVOLUTION OF CONTENT CONSUMPTION ON MOBILE AND TABLETS

If the corporation is or intends to become a registered charity as defined in the Income Tax Act, a copy of these documents must be sent to:

Grandes tendances et leurs impacts sur l acquisition de produits et services TI.

«BOREAL 20» MODE D EMPLOI / USER MANUAL REF S.A HENRI DEPAEPE

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

APPENDIX 6 BONUS RING FORMAT

Formulaire d inscription (form also available in English) Mission commerciale en Floride. Coordonnées

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Stratégie DataCenters Société Générale Enjeux, objectifs et rôle d un partenaire comme Data4

Critères à l attention des fabricants et des fournisseurs de biens ou de services : dispositifs mécaniques pour bingo

Transcription:

Heavy Duty Meter Model 407026 USER GUIDE

Introduction Congratulations on your purchase of the Extech Heavy Duty Light Meter. This light meter offers selectable lighting types, data record/recall, relative display mode, and PC interface. This professional meter, with proper care, will provide years of safe reliable service. Specifications General Specifications Circuit Display Measurement ranges Data Hold Lighting Types Sensor Structure Memory Store/Recall Sample rate Zero Adjust Auto Power Off Custom one-chip LSI microprocessor circuit 3-1/2 digit (2000 count) LCD display with contrast adjustment LUX: 0 to 50,000 LUX (3 range); Fc: 0 to 5000 Fc (3 range); Relative mode: 0 to 1999% Freezes displayed reading Sodium, Daylight/Tungsten, Fluorescent and Mercury Cosine/color corrected photo-diode meets C.I.E. Records/Recalls Max/Min/Avg readings 0.4 seconds (approx.) per reading Push-button procedure After approx. 10 minutes Data Output RS-232 PC serial interface (optional software/cable PN 407001) Operating conditions Power Supply Power consumption 32 F to 122 F (0 C to 50 C); <80% RH 9V battery Weight 0.71 lbs. (320 g) Dimensions Approx. 5 ma DC. (approx. 200 hr battery life) Instrument: 7.1 x 2.8 x1.3" (180 x 72 x 32 mm) Sensor: 3.3 x 2.2 x 0.7" (85 x 55 x 17.5 mm) Range Specifications Measurement Range Display Resolution Accuracy LUX 2,000 LUX 0-1,999 LUX 1 LUX ± (4% + 2 digits) 20,000 LUX 1,800-19,990 LUX 10 LUX of full scale 50,000 LUX 18,000-50,000 LUX 100 LUX Foot Candles 200 Fc 0-186.0 Fc 0.1 Fc 2,000 Fc 167-1,860 Fc 1 Fc 5,000 Fc 1,670-5,000 Fc 10 Fc Relative mode 0-1999% 1% Note: The accuracy specification above applies to calibration performed using a precision standard incandescent tungsten light source of 2856 O K with meter on the tungsten setting. 2

Meter Description 1 LCD Display 2 Keypad 5 6 3 Light sensor 4 Battery compartment (rear) 5 Sensor input 6 RS-232 PC Interface jack 1 2 8 7 Protective Holster 8 LCD Contrast Adjust 7 4 3 3

Operation Meter Power and Automatic Power Off 1. Press the POWER button to turn the meter on. If the display does not switch on, check the 9V battery. 2. Press the POWER button again to turn the meter off. 3. The meter has an automatic power off feature that conserves battery energy. After 10 minutes the meter automatically shuts off. To defeat this feature, press the RECORD button to put the meter in the recording mode. Display ZERO Calibration Please perform a zero calibration before each use. This will ensure the highest accuracy. 1. Place the sensor cover over the light sensor, effectively blocking all light to the sensor. 2. Select the 2,000 LUX range using the RANGE switch. 3. Press the ZERO button. The reading should be zero. 4. Remove the sensor cover from the light sensor and proceed. Selecting the unit of measure Press the LUX/Fc button to select the desired unit of measure. The display icons will reflect the current setting. Selecting a light source Select the type of lighting to be measured by pressing the LIGHT SOURCE button. The display will indicate the lighting type icon (see icon list below). L = Tungsten/Daylight (use this setting when calibrating with a Tungsten lamp) F = Fluorescent S = Sodium C = Mercury Note: For Halogen and Metal Halide light use the Tungsten setting Taking Measurements Hold the light sensor in the area where light is to be collected. The light being measured must encompass the entire surface of the light sensor dome (pin point lighting such as with LED light cannot be measured). The display will indicate the light intensity value in LUX or Foot candles (Fc). Note that since the main display area is limited to a reading of 1999, the right-most digit in the 20,000 LUX and 5,000 Fc ranges appears on the lower LCD line. In the 50,000 LUX range, the last two digits appear on the lower LCD line It may be necessary to adjust the display contrast due to a change in viewing angle or voltage drift. Use the LCD Contrast adjustment located on the right side of the meter to set the preferred contrast. Display Range Selection Take a measurement starting at the highest range and then work down using the RANGE switch. If the display shows dashes along the top of the reading area ( ), the input exceeds the maximum value for the selected range; select a higher range. If the display shows dashes along the bottom of the reading area ( ), the input is too low; select a lower range. 4

Data Hold While measuring, press the HOLD button to freeze the reading. The LCD will display D.H. indicating that the Data Hold function is engaged. Press HOLD again to return to normal operation. Relative % Mode In the RELATIVE mode of operation, the meter displays light level as a comparison to a reference value. The reference value is stored by pressing the % button while the desired light level reference is on the display. When the button is pressed, 100% will be displayed and the % icon will appear. After the % button is pressed, light measurements will be displayed as a percentage of the reference value. For example, if the light level reference is 1000 LUX, a display of 500 LUX will be represented as 50%. Further, a light level of 250 LUX will display as 25%. Use the equation below: Light measurement Display % = --------------------------------------------------------------------------- X 100 Stored reference light measurement Press the % button again to return to normal operation. Maximum (MAX), Minimum (MIN), and Average (AVG) readings The meter can keep track of the highest, lowest, and average readings for later recall. 1. Press the RECORD button to start tracking the MAX, MIN, and AVG readings. The REC display will switch on. 2. When desired, press the RECALL button. 3. The MAX display icon appears next to the REC display icon. The reading shown is the highest reading encountered since the RECORD button was pressed. 4. Press RECALL twice more to view the MIN and AVG readings. 5. Press the RECORD button to return to normal operation. RS-232 PC Interface This meter is equipped with a RS-232 serial data port. For streaming of data to a PC via the RS232 Output jack, the optional 407001-USB kit (RS232 to USB cable and driver CD) along with the 407001 software (available free at ) are required. Battery Replacement When the low battery indicator appears (LBT), replace the battery as soon as possible. Reliable readings can be obtained for several hours after the first appearance of the low battery indication. To replace the battery: 1. Remover the meter's rubber protective holster. 2. The battery compartment is located on the lower back of the meter. Pry the battery compartment cover off using a small coin or screwdriver and remove the battery. 3. Replace the 9V battery and reinstall the cover. 4. Ensure that the battery cover is secured after replacing the battery. 5

Typical Light Levels Lux Foot Candles Factories 20-75 2-7 Emergency Stairs, Warehouse Lux Foot Candles Home 100-150 10-15 Washing 75-150 7-15 Exit/Entrance Passages 150-200 15-20 Recreational Activities 150-300 15-30 Packing Work 200-300 20-30 Drawing Room, Table 300-750 30-75 Visual Work: Production Line 300-500 30-50 Makeup 750-1,500 75-150 Typesetting: Inspection Work 500-1,500 50-150 Reading, Study 1,500-3,000 150-300 Electronic Assembly, Drafting 1,000-2,000 100-200 Sewing Office Restaurant 75-100 7-10 Indoor Emergency Stairs 75-150 7-15 Corridor Stairs 100-200 10-20 Corridor Stairs 150-300 15-30 Entrance, Wash Room 200-750 20-75 Conference, Reception Room 300-750 30-75 Cooking\Dinning Room 750-1,500 75-150 Clerical Work 750-1,500 75-150 Show Window 1,500-2,000 150-2000 Typing, Drafting Store Hospital 75-150 7-15 Indoors 30-75 3-7 Emergency Stairs 150-200 15-20 Corridor/Stairs 75-100 7-10 Stairs 200-300 20-30 Reception 100-150 10-15 Sick Room, Warehouse 300-500 30-50 Display Stand 150-200 15-20 Waiting Room 500-750 50-75 Elevator 200-750 20-75 Medical Exam Room 750-1,500 75-150 Show Window, Packing Table 750-1,500 75-150 Operating Room 1,500-3,000 150-300 Storefront, Show Window 5,000-10,000 Common Conversion Factors Illuminance (Visible Flux Density) 1 lm/m 2 = 1 lux (lx) 10-4 lm/cm 2 500-1000 Eye Inspection 10-4 phot (ph) 9.290 x 10-2 lm/ft 2 9.290 x 10-2 foot-candles Luminance (Visible Flux Density per Solid Angle) 1 lm/m 2 /sr = 1 candela/m 2 Luminous Intensity (Visible Flux per Solid Angle) 1 lm/sr = 1 candella Luminous Flux ( Visible Flux) 1 lumen (lm) = 1.464 x 10-3 watts @ 555 nm 6

Warranty FLIR Systems, Inc. warrants this Extech Instruments brand device to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department for authorization. Visit the website for contact information. A Return Authorization (RA) number must be issued before any product is returned. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. FLIR Systems, Inc. specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. FLIR s total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration, Repair, and Customer Care Services FLIR Systems, Inc. offers repair and calibration services for the Extech Instruments products we sell. NIST certification for most products is also provided. Call the Customer Service Department for information on calibration services available for this product. Annual calibrations should be performed to verify meter performance and accuracy. Technical support and general customer service is also provided, refer to the contact information provided below. Support Lines: U.S. (877) 439 8324; International: +1 (603) 324 7800 Technical Support: Option 3; E mail: support@extech.com Repair & Returns: Option 4; E mail: repair@extech.com Product specifications are subject to change without notice Please visit our website for the most up to date information FLIR Commercial Systems, Inc., 9 Townsend West, Nashua, NH 03063 USA Copyright 2014 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form 7

Garantie FLIR Systems, Inc. garantit que cet appareil Extech Instruments est exempt de défauts matériaux et de fabrication pendant un an à partir de la date d envoi (une garantie limitée de six mois s applique aux capteurs et aux câbles). Si le renvoi de l appareil pour réparation devient nécessaire durant ou après la période de garantie, contactez le service client pour autorisation. Pour obtenir les coordonnées, visitez le site Web suivant :. Un numéro d autorisation de retour (AR) doit être délivré avant tout retour de produit. L expéditeur prend à sa charge les frais d expédition, le fret, l assurance et l emballage correct de l appareil afin de prévenir toute détérioration durant le transport. Cette garantie ne s applique pas aux dommages imputables à l utilisateur, tels que l usage impropre ou abusif, un mauvais câblage, une utilisation non conforme aux spécifications, un entretien ou une réparation incorrecte, ou toute modification non autorisée. FLIR Systems, Inc. déclinera spécifiquement toute garantie ou qualité marchande ou aptitude à l emploi prévu, et ne sera en aucun cas tenu responsable pour tout dommage conséquent, direct, indirect ou accidentel. La responsabilité totale de FLIR est limitée à la réparation ou au remplacement du produit. La garantie définie ci dessus est inclusive et aucune autre garantie, écrite ou orale, n est exprimée ou implicite. Calibrage, réparation et services après vente FLIR Systems, Inc. offre des services de calibrage et de réparation pour les produits Extech Instruments que nous commercialisons. Nous fournissons également une certification NIST pour la plupart des produits. Contactez notre service client pour toute information sur les services de calibrage disponibles pour ce produit. Un calibrage doit être effectué chaque année pour vérifier les performances et la précision du mètre. Nous offrons également une assistance technique et un service à la clientèle. Veuillez vous reporter aux coordonnées fournies ci dessous. Lignes d assistance: États Unis (877) 439 8324; international: +1 (603) 324 7800 Service d assistance technique : Option 3 ; E mail : support@extech.com Réparations et retours : Option 4 ; E mail : repair@extech.com Les spécifications produit sont sujettes à modifications sans préavis. Pour les toutes dernières informations, veuillez visiter notre site Web. FLIR Commercial Systems, Inc., 9 Townsend West, Nashua, NH 03063 USA Copyright 2014 FLIR Systems, Inc. Tous droits réservés, y compris la reproduction partielle ou totale sous quelque forme que ce soit. 8

Garantía FLIR Systems, Inc., garantiza este dispositivo marca Extech Instruments para estar libre de defectos en partes o mano de obra durante un año a partir de la fecha de embarque (se aplica una garantía limitada de seis meses para cables y sensores). Si fuera necesario regresar el instrumento para servicio durante o después del periodo de garantía, llame al Departamento de Servicio a Clientes para obtener autorización. Visite para Información de contacto. Se debe expedir un número de Autorización de Devolución (AD) antes de regresar cualquier producto. El remitente es responsable de los gastos de embarque, flete, seguro y empaque apropiado para prevenir daños en tránsito. Esta garantía no se aplica a defectos resultantes de las acciones del usuario como el mal uso, alambrado equivocado, operación fuera de las especificaciones, mantenimiento o reparación inadecuada o modificación no autorizada. FLIR Systems, Inc., rechaza específicamente cualesquier garantías implícitas o factibilidad de comercialización o idoneidad para cualquier propósito determinado y no será responsable por cualesquier daños directos, indirectos, incidentales o consecuentes. La responsabilidad total de FLIR está limitada a la reparación o reemplazo del producto. La garantía precedente es inclusiva y no hay otra garantía ya sea escrita u oral, expresa o implícita. Servicios de calibración, reparación y atención a clientes FLIR Systems, Inc., ofrece servicios de reparación y calibración para los productos que vendemos de Extech Instruments. Además ofrecemos certificación NIST para la mayoría de los productos. Llame al Departamento de Servicio al Cliente para solicitar información de calibración para este producto. Para verificar el funcionamiento y precisión se debe realizar la calibración anual. Además se provee Soporte Técnico y servicios generales al cliente, consulte la información de contacto en seguida. Líneas de soporte: EE.UU. (877) 439 8324; Internacional: +1 (603) 324 7800 Soporte Técnico Opción 3; correo electrónico: support@extech.com Reparación / Devoluciones: Opción 4; correo electrónico: repair@extech.com Las especificaciones del producto están sujetas a cambios sin aviso Por favor visite nuestra página en Internet para la información más actualizada FLIR Commercial Systems, Inc., 9 Townsend West, Nashua, NH 03063 USA Certificado ISO 9001 Copyright 2014 FLIR Systems, Inc. Reservados todos los derechos, incluyendo el derecho de reproducción total o parcial en cualquier medio 9