1 Réf O33 / d Entrée detection P1 Ajustage Ualt=Uréseau Filtre P2 R713 / R723 Pot TENSION EXTERIEUR SWITCH DEMANDE D'EGALISATION Entrée pot tension Excitateur Régulateur série R200 ALT RESEAU R R 723 Installation et/and maintenance
2 NOTE : LES SCHEMAS DE BRANCHEMENT GENERAUX SONT DONNES A TITRE INDICATIF. POUR LE BRAN- CHEMENT REEL SE REPORTER AUX SCHEMAS FOURNIS AVEC L'ALTERNATEUR. NOTE : THE ELECTRAL CONNECTION DIAGRAM ARE ONLY GIVEN AS AN INDICATION. PLEASE REFER TO THE SPECIFIC DIAGRAMS OF YOUR ALTERNATOR. AVERTISSEMENT : EN VUE DE PREVENIR TOUT PREJUDICE AUSSI BIEN AUX PERSONNES QU'A L'INSTALLATION, LA MISE EN SERVICE DE CET APPAREIL NE DOIT ETRE EFFECTUEE QUE PAR UN PERSONNEL QUA- LIFIE. WARNING : TO PREVENT PERSONNAL INJURY OR EQUIPMENT DAMAGE, ONLY QUALIFIED TECHNICIANS/OPE- RATORS SHOULD INSTALL AND OPERATE THIS DEVICE. ATTENTION : NE PAS UTILISER D'APPAREILS DE MESURE A HAUTE TENSION. UNE MAUVAISE UTILISATION DE CERTAINS APPA- REILS PEUT ENTRAINER LA DESTRUCTION DES SEMI CONDUCTEURS INCLUS DANS LE REGULA- TEUR. CAUTION : MEGGERS AND HIGH POTENTIAL TEST EQUIP- MENT MUST NOT BE USED. INCORRECT USED OF SUCH EQUIPMENT COULD DAMAGE THE SEMICONDUCTORS CONTAINED IN THE REGULATOR. SOMMAIRE CONTENTS Pages 1 - INTRODUCTION Généralités Spécifications PRINCIPE DE FONCTIONNEMENT INSTALLATION Montage Interconnexions MISE EN SERVICE Réglage tension Réglage d'égalisation Mise en service Dépannage SCHEMAS DE BRANCHEMENT... 5 à ENCOMBREMENT ET FIXATIONS Pages 1 - INTRODUCTION General Specifications OPERATION PRINCIPLE INSTALLATION Fitting Interconnections STARTING UP Voltage adjustment Equalization adjustment Starting up Fault finding WIRING DIAGRAMS... 5 to DIMENSIONS
3 1 - INTRODUCTION Généralités Le module 3F R713 ou R723 est utilisé en connexion avec un régulateur série R200 pour égaliser la tension d'un alternateur à celle du réseau avant d'effectuer le couplage avec celui-ci, lorsque l'installation fonctionne automatiquement ou que l'égalisation manuelle de ces tensions n'est pas possible. Ceci permet d'éviter les surintensités provoquées par un couplage sur un réseau présentant une différence de tension avec la machine. Cette différence de tension est en général due aux fluctuations du réseau puisque par principe l'alternateur est régulé, donc à tension constante (au statisme près). Ces fluctuations peuvent sur certains réseaux atteindre +/-10%. REFERENCES DES MODULES 3F Entrée mesure réseau 100/110V 220/380V R713 R Spécifications Entrée mesure réseau : Un +/-15% max, 50Hz ou 60Hz isolée par transformateur interne au circuit. Consommation : < 2VA Précision d'égalisation : +/- 1%de Un Dérive en température : 1% de Un pour Tambiante variant de -20 à 25 C ou de 25 à 70 C Temps de réponse : < 300ms Température de fonctionnement : -20 C à +70 C Température de stockage : -40 C à +85 C Encombrement : hauteur 115mm largeur 115mm longueur 96mm Poids 0,5 Kg (1Lb) Puissance dissipée : < 1W Vibrations maximum : 2 à 10 Hz : déplacement 2mm crête à crête 10 à 100 Hz : vitesse 46 mm/s RMS 100 à 300 Hz : accélération 4g 2 - PRINCIPE DE FONCTIONNEMENT Le module 3F mesure la tension du réseau et, lors de la fermeture d'un contact sec fourni par l'installation pendant la synchronisation, substitue une image de la tension réseau à la consigne du régulateur. ATTENTION : CECI ETANT EFFECTUE PAR L'ENTREE POTENTIOMETRE TENSION EXTERIEUR DU REGULATEUR, IL EST IMPERATIF QUE CELUI-CI SOIT CONFIGURE POUR L'UTILISATION D'UN POTENTIOMETRE EXTERIEUR (STRAP ST2 COUPE). Le potentiomètre de réglage tension en service sera alors celui situé sur le module 3F (P2), et si l'on doit utiliser un potentiomètre tension extérieur, il faudra alors positionner le switch situé sur le module 3F et connecter ce potentiomètre entre les bornes 6 et 7 du connecteur de celui-ci, le blindage étant relié à la borne 8. Dans le cas des installations moyenne tension où l'on utilise des transformateurs abaisseurs entre le réseau et le module 3F, il sera généralement utile de recaler légèrement le potentiomètre égalisation réseau (P1), ceci afin de prendre en compte les différents rapports de transformation. (voir réglages). 1 - INTRODUCTION General The 3F R713 or R723 modules are used in connection with a R200 series regulator for equalizing the voltage of an alternator with that of the network before coupling, when the installation operates automatically or when manual equalization of these voltages is not possible. This prevents excessive current caused by coupling a network to the machine when both are not at the same voltage. This difference in voltage is usually due to fluctuations in the network voltage because the alternator is regulated at a constant voltage (except for cases of voltage droop). On some networks these fluctuations can reach ± 10%. REFERENCES OF 3F MODULES Network sensing input 100/110V 220/400V R713 R Specifications Network measurement input : Un ± 15% maximum, 50 Hz or 60 Hz, insulated by an internal transformer. Consumption : < 2VA Equalization precision : ± 1% of Un Temperature shift : 1% of Un for delta T ambient variing from -20 to 25 C or 25 to 70 C Response time : < 300 ms Operating temperature : -20 C to +70 C Storage temperature : -40 C to +85 C Dimensions : height 100 mm width 115 mm depth 115 mm Weight 0.5 kg (1Lb) Dissipated power : < 1W Maximum Vibrations level : 2 à 10 Hz : displacement 2mm peak-peak 10 à 100 Hz : speed 46 mm/s RMS 100 à 300 Hz : acceleration 4g 2 - OPERATION PRINCIPLE The 3F module measures the voltage of the network and, when the potential free contact supplied by the installation is closed (when synchronizing), it substitutes an image of the network voltage in place of the regulator set voltage. IMPORTANT NOTE : AS THIS IS CARRIED OUT THROUGH THE REMOTE VOLTAGE POTENTIOMETER INPUT, T IS ESSENTIAL THAT THE REGULATOR CONFIGURATION IS SUITABLE FOR THE USE OF A REMOTE POTENTIOMETER (STRAP ST2 OPEN). The voltage potentiometer in service will then be that situated on the module 3F (P2), and if an outside voltage potentiometer must be used the switch on module 3F will have to be set and this potentiometer connected between terminals 6 and 7 of the 3F module connection block, with the shield connected to terminal 8. In the case of medium voltage installations in which dropping transformers are used between the network and the 3F module, it will generally be useful to slightlyreadjust the network equalization potentiometer P1 in order to take into account the various transformer ratios (see paragraph "adjustments"). 3
4 SYNOPTIQUE DES SYNOPTIC DIAGRAM OF Entrée detection P1 Ajustage Ualt=Uréseau Filtre Sensing input P1 Adjustment Ualt=Unetwork Filter P2 SWITCH R713 / R723 Entrée pot tension Régulateur série R200 P2 SWITCH R713 / R72 voltage pot input R200 series regulator Pot TENSION EXTERIEUR Excitateur EXTERNAL VOLTAGE Pot Exciter DEMANDE D'EGALISATION ALT EQUALIZATION REQUEST ALT RESEAU NETWORK 3 - INSTALLATION 3 - INSTALLATION Montage Le module 3F est conçu pour être monté dans n'importe quelle position, toutefois il est nécessaire de veiller à ce que l'air circule librement autour de lui. Il est conçu pour être encliqueté sur rail DIN symétrique REF: PR3 ENTRELEC par exemple ou fixé par ses pattes Interconnections (voir pages 6 et 8) Entrée mesure : 1,2,3 de CN V (R713) ou 0-220V (R723) entre 1 et 2 de CN V (R713) ou 0-380V (R723) entre 1 et 3 de CN3 Entrée commande d'égalisation : 4,5 de CN3 Ce contact doit être libre de tout potentiel et il est recommandé d'utiliser une connexion par fils blindés dont le blindage ne sera relié qu'à la borne 8 de CN3. La demande d'égalisation se fait par la fermeture de ce contact lors de la demande de synchronisation avant couplage. Une LED rouge () signale la fermeture de ce contact. Entrée potentiomètre tension extérieur : 6,7 de CN3 Lorsqu'un potentiomètre de réglage tension à distance doit être utilisé, il doit être connecté en résistance variable, le curseur en 7 et le blindage en 8 de CN3, et le switch du module 3F doit être en position haute. Le prépositionner au maximum de résistance (minimum de tension) pour éviter le risque de déclenchement en surtension. Sortie vers le régulateur série R200 : 4,8,9,10 de CN3 A connecter avec du fil blindé à l'entrée potentiomètre extérieur du régulateur, attention à la polarité, le 10 doit être connecté à la borne 6 du CN2 du régulateur, le 9 au 7 de CN2, le 8 au 5 de CN2, le 4 au 9 de CN2, le blindage n'étant relié qu'à la borne 5 de CN2 et non à la terre. 4 - MISE EN SERVICE Réglage tension alternateur (P2) Ce réglage peut être effectué par action sur le potentiomètre P2 interne au module 3F ( vers le haut) ou par un potentiomètre ou un servo-potentiomètre à distance ( vers le bas) Fitting The 3F module is designed to be fitted in any position, however care should be taken to ensure that air can circulate freely around it. It is designed to be clipped to a symmetrical DIN rail: for ins-tance the EURELEC ref : PR3 or mounting by its brackets Interconnections (see page 7 and 9) Measurement input : 1,2,3 of CN V (R713) or 0-220V (R723) between 1 and 2 of CN V (R713) or 0-400V (R723) between 1 and 3 of CN3 Equalization command input : 4,5 of CN3 Important note : this contact should be free of any potential and shielded cable is recommended the shield will be connected to terminal 8 of CN3. The equalization order is given by closing this contact during the synchronization request before coupling. A red LED () indicates closing of this contact. Outside voltage potentiometer input : 6,7 of CN3 When a remote voltage potentiometer has to be used it should be connected between these terminals as a variable resistor, the cursor connected to 7 of CN3 and the shield to 8 of CN3. The switch of the module 3F should be down. Prepositioning should be at maximum resistance (minimum voltage) to avoid the danger of switching in on overvoltage. Output towards the R200 regulator : 4,8,9,10 of CN3 To be connected with a shielded cable to the connector CN2 of the regulator, take care about polarity, 10 should be connected to terminal 6 of CN2, 9 to 7 of CN2, 8 to 5 of CN2, 4 to 9 of CN2 and shield to 5 of CN2 only. 4 - STARTING UP Alternator voltage P2 adjustment This adjustment can be made by adjusting the 3F module internal potentiometer P2 (when is in up position) or by a remote potentiometer or servo-potentiometer (switch in down position). 4
5 4.2 - Réglage d'égalisation (P1) Ce réglage s'effectue une fois pour toutes, à la mise en service, de la façon suivante : - Alternateur à vide et tension réseau présente entre 1-2 ou 1-3 suivant valeur - Fermer le contact entre 4 et 5 du connecteur. - Ajuster P1 pour que la tension machine soit égale à celle du réseau ou que les tensions soient identiques de chaque coté du contacteur de couplage (cas des machines bloc) - Plomber P1. Le réglage est terminé NOTE : Il est possible que pendant l'égalisation on observe un léger battement de la tension machine fonction de la différence de fréquence entre le réseau et la machine. Ce phénomène normal disparaîtra dès que les fréquences seront suffisamment proches. Si cela posait un problème, on peut en diminuer l'amplitude en agissant sur le potentiomètre stabilité du régulateur Mise en service Dans le cas d'un montage en armoire, il est conseillé avant de connecter le module 3F d'avoir déjà fait fonctionner le régulateur seul. Il suffit alors de couper le strap ST2 du régulateur série R200, de connecter le module 3F, de réajuster la tension nominale si nécessaire et de vérifier l'égalisation comme indiqué dans le Dépannage Les seuls problèmes pouvant interférer sur le fonctionnement sont : - Tension réseau incorrecte ou absente lors de la demande d'égalisation - Raccordement incorrect. - Strap ST2 du régulateur non coupé. - Usage d'un potentiomètre à distance et switch du module 3F mal positionné. - Raccordement entre régulateur et module 3F non blindé ou blindage mal raccordé. - Environnement très parasité et fils non blindés sur la commande d'égalisation Equalization adjustment P1 This adjustment is made once and for all on starting up as follows: - Alternator off load and network voltage present between 1 and 2 or 1 and 3, depending on its value - Close the contact between 4 and 5 of the connection block, or strap the terminals - Adjust P1 so that the machine voltage is equal to that of the network, or so that the voltages are the same on both sides of the coupling switch (in the event of machines directly coupled with transformer) - Seal P1. Adjustment is finished. NOTE : During equalization one may observe slight oscillation of the machine voltage as a result of the frequency difference between the network and the machine. This phenomenon is normal and will disappear as soon as the two frequencies are sufficiently close. If it makes problem its amplitude can be reduced by adjusting the stability potentiometer of the regulator Starting up When the unit is mounted in the terminal box it is recommended to operate the regulator alone before connecting the 3F module. It is then only necessary to copen the strap ST2 of the R200 series regulator, to connect the 3F module, to adjust the set voltage if necessary and to check equalization as explained in paragraph Fault finding The only problems which could affect operation are: - Network voltage incorrect or absent during the equalization order - Incorrect connections - ST2 regulator strap not cut - Use of a remote potentiometer with the switch of the 3F module not in up position. - Connection between the regulator and the 3F module not shielded or shield incorrectly connected - High interference environment and wires not shielded on the equalization control. 5 - PRESENTATION ET BRANCHEMENT 5 - WIRING DIAGRAMS RESEAU NETWORK P1 TENSION VOLTAGE P2 MESURE RESEAU R713 R723 0V 0V 100V 220V 110V 380V VERS 6 DE DES VERS 7 DE REGULATEURS VERS 5 DE SERIE R200 VERS 9 DE CN2} VERS POTENTIOMETRE TENSION A DISTANCE NETWORK MEASUREMENT R713 R723 0V 0V 100V 220V 110V 380V TO 6 OF CN2 } TO 7 OF CN2 TO 5 OF CN2 TO 9 OF CN2 TO 1KOHMS 2W REMOTE VOLTAGE POTENTIOMETER OF R200 SERIES REGULATORS A FERMER POUR DEMANDE D'EGALISATION CLOSE FOR EQUALIZATION ORDER 5
6 - Propriété de MLS. Ne pas diffuser sans accord préalable P4 pot GAIN dynamique REGLAGE D'EGALISATION P01 R723 P5 pot STABILITE R222 REGLAGE TENSION INTERIEUR P02 P3 pot TENSION ST2 coupé avec R723 P8 potentiométre LAM SWITCH ST01 EN POSITION POTENTIOMETRE INTERIEUR P2 pot SOUS-VITESSE ST3 P1 pot COS-PHI Sortie sur borne Circuit de mesure I< 5Amp Puissance régulateur I< 15Amp U< 250V Puissance alternateur P6 limit pot Ifield MAX P9 over-voltage pot 1 CN3 10 CN1 CN CABLAGE VU EN ROTATION HORAIRE. EN ROTATION ANTIHORAIRE, LA BORNE 10 DE CN1 DOIT ETRE CONNECTEE A LA PHASE U. SI LE REGULATEUR EST INTERIEUR A LA BOITE A BORNES, VOIR BORNES "RH" OU "RAH" AU BORNIER ALTERNATEUR non connecté Pot tension exterieur optionnel 1K 2W Pot cos Ø exterieur optionnel 4,7K 2W DESEXCITATION OPTIONNELLE MESURE Iexc (optionnel) + E02 E01 contact à fermer en demande d'égalisation avec le réseau E05 E06 } E07 ATTENTION: LES BLINDAGES NE DOIVENT ETRE RELIES QUE DU COTE REGULATEUR 0V 100V RH Transformateur ou E04 E03 0V Un RAH N U1 +C S1 S2 +Exc RESEAU V1 P1 P2 ALTERNATEUR -Exc W1 -C ROT ROT SCHEMA CATALOGUE N A HOR ANTI- HOR UTILISATION BOITE A BORNES HORS FOURNITURE BRANCHEMENT R222 / R723 3F AVEC BOOSTER 6
7 - Ifield MEASURE (optional) + Property of MLS. Do not spread without special agreement EQUALISATION ADJUST R723 P01 P4 pot dynamic GAIN P5 pot STABILITY R222 VOLTAGE ADJUST (IF INTERNAL) P02 ST01 SWITCH SEEN INCASE OF INTERNAL POTENTIOMETER Output on terminal block Sensing wires I< 5Amp 1 CN3 10 P8 potentiometer LAM P3 pot VOLTAGE ST2 open when R723 is used P2 pot UNDER-FREQUENCY P6 pot AVR current limit ST3 P9 pot overvoltage P1 pot COSØ AVR power wires I< 15Amp U< 250V Generator power cables CN1 CN WIRING SEEN IN CASE OF CLOCKWISE ROTATION. IF COUNTER CLOCKWISE, TERMINAL 10 OF CN1 MUST BE CONNECTED TO PHASE U. IF THE AVR IS INSIDE THE GENERATOR, SEE TERMINALS "RH" AND "RAH" ON TERMINAL BLOCK not connected OPTIONAL DESENERGIZING E02 E01 optional external voltage Potentiometer 1K 2W optional external cosø potentiometer 4,7K 2W E05 E06 } E07 CAUTION : THE SHIELDS MUST BE CONNECTED ONLY TO THE AVR close these contacts for network voltage equalization 0V 100V RH Transformer or E04 E03 0V Un RAH N U1 +C NETWORK S1 S2 +Exc V1 P1 P2 -Exc ALTERNATOR W1 -C CATALOG WIRING CW CCW TERMINAL BOX A N UTILIZATION OUT OF SUPPLY R222 / R723 3F WIRING WITH BOOSTER 7
8 - Propriété de MLS. Ne pas diffuser sans accord préalable P4 pot GAIN dynamique REGLAGE D'EGALISATION P01 R723 P5 pot STABILITE R222 REGLAGE TENSION INTERIEUR P02 P3 pot TENSION ST2 coupé avec R723 P8 potentiométre LAM SWITCH ST01 EN POSITION POTENTIOMETRE INTERIEUR P2 pot SOUS-VITESSE ST3 P1 pot COS-PHI Sortie sur borne Circuit de mesure I< 5Amp Puissance régulateur I< 15Amp U< 250V Puissance alternateur P6 limit pot Ifield MAX P9 over-voltage pot 1 CN3 10 CN1 CN non connecté DESEXCITATION OPTIONNELLE REPRESENTATION POUR ROTATION HORAIRE. EN ROTATION ANTIHORAIRE, LA BORNE 10 (ou 9 en 220V) DE CN1 DOIT ETRE CONNECTEE A LA PHASE W Pot tension exterieur optionnel 1K 2W Pot cos Ø exterieur optionnel 4,7K 2W MESURE Iexc (optionnel) + E02 E01 contacts à fermer en demande d'égalisation avec le réseau E05 E06 } E07 ATTENTION: LES BLINDAGES NE DOIVENT ETRE RELIES QUE DU COTE REGULATEUR RESEAU E04 E03 S1 S2 U1 +C P1 P2 Bob auxiliaires +Exc V1 ALTERNATEUR TRIPHASE -Exc W1 UTILISATION BOITE A BORNES HOR ANTI- HOR HORS FOURNITURE CW ACW N -C SCHEMA CATALOGUE N A BRANCHEMENT R222/R723 3F AVEC BOOSTER <A49 8
9 - Ifield MEASURE (optional) + Property of MLS. Do not spread without special agreement P4 pot dynamic GAIN EQUALISATION ADJUST R723 P01 P5 pot STABILITY R222 VOLTAGE ADJUST (IF INTERNAL) P02 P3 pot VOLTAGE ST2 open when R723 is used P2 pot UNDER-FREQUENCY ST3 P1 pot COSØ P8 potentiometer LAM ST01 SWITCH SEEN INCASE OF INTERNAL POTENTIOMETER Output on terminal block P6 pot AVR current limit P9 pot overvoltage 1 CN3 10 Sensing wires I< 5Amp CN1 CN AVR power wires I< 15Amp U< 250V Generator power cables not connected OPTIONAL DESENERGIZING WIRING IN CASE OF CLOCKWISE ROTATION IF COUNTER CLOCKWISE TERMINAL 10 OF CN1 MUST BE CONNECTED TO PHASE W E02 E01 optional external voltage Potentiometer 1K 2W optional external cosø potentiometer 4,7K 2W close these contacts for network voltage equalization E05 E06 } E07 CAUTION : THE SHIELDS MUST BE CONNECTED ONLY TO THE AVR E04 E03 S1 S2 U1 +C P1 P2 Auxiliary windings +Exc NETWORK V1 ALTERNATOR -Exc W1 N -C CW ACW TERMINAL BOX CATALOG WIRING A N UTILIZATION OUT OF SUPPLY R222 / R723 3F WIRING WITH BOOSTER >A49 9
10 CN3 6 - ENCOMBREMENTS ET FIXATIONS - En standard, fixation sur rail DIN symétrique Ref : PR3 ENTRELEC (par exemple) - Autres fixation, consulter l'usine MONTAGE SUR RAIL DIN 6 - DIMENSIONS FITTING IN CONTROL PANEL 115mm 96mm 115mm 10
11 Imprimerie MOTEURS LEROY-SOMER RC ANGOULEME B MOTEURS LEROY-SOMER ANGOULÊME CEDEX - FRANCE
Fabricant. 2 terminals
Specifications Fabricant Nominal torque (Nm) 65 Minimal torque (Nm) 0,63 Coil resistance - 20 C (ohms) 20 Rated current DC (A) 1 Rotor inertia (kg.m 2 ) 2.10-3 Weight (kg) 7,20 Heat dissipation continuous
Plus en détail03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000
03/2013 Mod: WOKI-60IP/TR Production code: DTWIC 6000 ENCASTRABLE INDUCTION DROP IN INDUCTION 11/2011 TECHNICAL FEATURES DOCUMENTATION S.A.V. Notice d utilisation : FX00326-A Guide d intervention : ---
Plus en détailContrôle d'accès Access control. Notice technique / Technical Manual
p.1/18 Contrôle d'accès Access control INFX V2-AI Notice technique / Technical Manual p.2/18 Sommaire / Contents Remerciements... 3 Informations et recommandations... 4 Caractéristiques techniques... 5
Plus en détailNotice Technique / Technical Manual
Contrôle d accès Access control Encodeur USB Mifare ENCOD-USB-AI Notice Technique / Technical Manual SOMMAIRE p.2/10 Sommaire Remerciements... 3 Informations et recommandations... 4 Caractéristiques techniques...
Plus en détailPaxton. ins-20605. Net2 desktop reader USB
Paxton ins-20605 Net2 desktop reader USB 1 3 2 4 1 2 Desktop Reader The desktop reader is designed to sit next to the PC. It is used for adding tokens to a Net2 system and also for identifying lost cards.
Plus en détailSA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS
SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS 4 5 6 7 4 5 6 7 1. Telephone Paging Volume Control 1. Contrôle de volume Paging Téléphone 2. Microphone Volume Control 2. Contrôle volume du microphone
Plus en détailInstructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00
Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00 HFFv2 1. OBJET L accroissement de la taille de code sur la version 2.0.00 a nécessité une évolution du mapping de la flash. La conséquence de ce
Plus en détailLe No.1 de l économie d énergie pour patinoires.
Le No.1 de l économie d énergie pour patinoires. Partner of REALice system Economie d énergie et une meilleure qualité de glace La 2ème génération améliorée du système REALice bien connu, est livré en
Plus en détailSoftware and Hardware Datasheet / Fiche technique du logiciel et du matériel
Software and Hardware Datasheet / Fiche technique du logiciel et du matériel 1 System requirements Windows Windows 98, ME, 2000, XP, Vista 32/64, Seven 1 Ghz CPU 512 MB RAM 150 MB free disk space 1 CD
Plus en détailMaster4Light. Caractérisation Optique et Electrique des Sources Lumineuses. Equipement 2-en-1 : source de courant et spectrophotomètre
DSF-M4L-Rev2.0-04/12 Master4Light Equipement 2-en-1 : source de courant et spectrophotomètre Interface graphique logicielle, connexion USB Configuration personnalisable : laboratoire et in-situ http://www.majantys.com
Plus en détailR.V. Table Mounting Instructions
PTSS165 ACCESSORY MOUNTING INSTRUCTIONS Use these instructions in conjunction with your main manual to properly assemble your gas grill. Refer to the main manual for safety, operating, cleaning and maintenance
Plus en détailGarage Door Monitor Model 829LM
Garage Door Monitor Model 829LM To prevent possible SERIOUS INJURY or DEATH from a closing garage door: NEVER permit children to operate or play with door control push buttons or remote control transmitters.
Plus en détailHow to Login to Career Page
How to Login to Career Page BASF Canada July 2013 To view this instruction manual in French, please scroll down to page 16 1 Job Postings How to Login/Create your Profile/Sign Up for Job Posting Notifications
Plus en détailFolio Case User s Guide
Fujitsu America, Inc. Folio Case User s Guide I N S T R U C T I O N S This Folio Case is a stylish, lightweight case for protecting your Tablet PC. Elastic Strap Pen Holder Card Holders/ Easel Stops Figure
Plus en détailCheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION
CANADA CONSOLIDATION CODIFICATION Cheque Holding Policy Disclosure (Banks) Regulations Règlement sur la communication de la politique de retenue de chèques (banques) SOR/2002-39 DORS/2002-39 Current to
Plus en détailZ-Axis Compliance Device Compliance en z
Compensation for different vertical positions Collision recognition in Z-direction Protection of parts and work pieces Monitoring of the insertion forces during assembly operations Monitoring of the picking
Plus en détailMoteur DC: Comment faire varier sa vitesse?
Moteur DC: Comment faire varier sa vitesse? Zone d'utilisation Moteur à excitation shunt Influence I e Petite perturbation : e.g. augmentation vitesse À partir de P : couple moteur P'' < couple résistant
Plus en détailWINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU
MANUAL / MANUEL VIDEO WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU ASSEMBLY INSTRUCTIONS GUIDE D ASSEMBLAGE NAVIGLOO 14-18½ ft/pi FISHING BOAT! RUNABOUT! PONTOON BOAT! SAILBOAT (SAILBOAT
Plus en détailTABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION
1 12 rue Denis Papin 37300 JOUE LES TOURS Tel: 02.47.68.34.00 Fax: 02.47.68.35.48 www.herve consultants.net contacts@herve consultants.net TABLE DES MATIERES A Objet...1 B Les équipements et pré-requis...2
Plus en détailThank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.
Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed. Note: This manual describes the appearance of the USB Stick, as well as the
Plus en détail3615 SELFIE. http://graffitiresearchlab.fr HOW-TO / GUIDE D'UTILISATION
3615 SELFIE http://graffitiresearchlab.fr HOW-TO / GUIDE D'UTILISATION Hardware : Minitel Computer DIN FM545 45 connector (http://www.gotronic.fr/art-fiche-din-fm545-4747.htm) Cable Arduino compatible
Plus en détailSYSTÈME DE GAINES À SPIRALE ET RACCORDS TOURNANTS
SYSTÈME DE GAINES À SPIRALE ET RACCORDS TOURNANTS SPIRAL PVC CONDUIT SYSTEMS AND REVOLVING FITTINGS Gaines a Spirale Matufless...page 190 Matufless spiral PVC conduit Raccords Tournants Matufless...page
Plus en détailInstructions Mozilla Thunderbird Page 1
Instructions Mozilla Thunderbird Page 1 Instructions Mozilla Thunderbird Ce manuel est écrit pour les utilisateurs qui font déjà configurer un compte de courrier électronique dans Mozilla Thunderbird et
Plus en détailLogitech Speaker System Z553 Setup Guide Guide d installation
Logitech Speaker System Z553 Setup Guide Guide d installation Logitech Speaker System Z553 English................. 3 Français................ 10 www.logitech.com/support...19 2 Package contents Logitech
Plus en détailAMC 120 Amplificateur casque
AMC 20 Amplificateur casque Manuel Utilisateur FRANCAIS 2 Rami AMC 20 SOMMAIRE Description... Utilisation... Synoptique... Face avant... Face arrière.... Câblage...... Caractéristiques... Informations...
Plus en détailContents Windows 8.1... 2
Workaround: Installation of IRIS Devices on Windows 8 Contents Windows 8.1... 2 English Français Windows 8... 13 English Français Windows 8.1 1. English Before installing an I.R.I.S. Device, we need to
Plus en détailVMT Mod : Ventilation modulée pour le tertiaire
Notice de Montage VMT Mod : Ventilation modulée pour le tertiaire VC 100876 - D920_a - RCS 956 506 828 - Imprimé en France/Printed in France VMT Mod est un système de ventilation intelligent à destination
Plus en détailMesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : 703 262. Français p 1.
Mesure chimique Chemical measurement Français p 1 English p 3 Sonde de température Pt 1000 Inox Pt 1000 stainless steel Version : 6010 Mesure chimique Sonde de température Pt 1000 Inox 1 Description La
Plus en détailGIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+
GIGABIT PCI DESKTOP ADAPTER Quick Installation Guide+ Guide d installation+ Check Your Package Contents Quick Installation Guide Gigabit Ethernet PCI Adapter CD with Manual and Drivers DO NOT insert the
Plus en détailContrôle d accès Access control MOD-TCPIP-AI. Notice technique / Technical Manual
Contrôle d accès Access control MOD-TCPIP-AI Notice technique / Technical Manual Notice technique Mod-TCPIP-AI 9 septembre 2008 v.1.0 p.2/16 Sommaire / Contents Sommaire / Contents...2 Remerciements...3
Plus en détailWarning: Failure to follow these warnings could result in property damage, or personal injury.
Western Steel & Tube 1 Storage Locker Extended Storage Locker Storage Cabinet Assembly And Use Instructions Warning: Failure to follow these warnings could result in property damage, or personal injury.
Plus en détailAUDIT COMMITTEE: TERMS OF REFERENCE
AUDIT COMMITTEE: TERMS OF REFERENCE PURPOSE The Audit Committee (the Committee), assists the Board of Trustees to fulfill its oversight responsibilities to the Crown, as shareholder, for the following
Plus en détailStainless Steel Solar Wall Light
V 2.9 Stainless Steel Solar Wall Light User Manual Please read and understand all instructions before use.retain this manual for future reference. V 2.9 Stainless Steel Solar Wall Light SPECIFICATIONS
Plus en détailSERIE TS-770 SYSTEME CONFERENCE
SERIE TS-770 SYSTEME CONFERENCE Le système de conférence à fils de TOA installation, utilisation et extension faciles, Avec la participation à distance via IP ou téléphone. Système de conférence compact,
Plus en détailACS-30-EU-PCM2-x-32A Régulation et surveillance du traçage électrique des bâtiments commerciaux et résidentiels pour divers domaines d application
ACS-0-EU-PCM-x-A Régulation et surveillance du traçage électrique des bâtiments commerciaux et résidentiels pour divers domaines d application Module de régulation et de distribution de l alimentation
Plus en détailThe new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.
General information 120426_CCD_EN_FR Dear Partner, The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you. To assist navigation
Plus en détailcalls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial
calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne Online Applications Tutorial 1/4 Pour postuler aux Appels d Offres de l ENP, vous devez aller sur la plateforme : calls.parisneuroscience.fr.
Plus en détailAMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32
THAT the proposed clause 6(1), as set out in Clause 6(1) of the Bill, be replaced with the following: Trustee to respond promptly 6(1) A trustee shall respond to a request as promptly as required in the
Plus en détailMODULES ÉLECTRIQUES. - systèmes électriques DC - onduleurs - convertisseurs - interrupteurs statiques. Notre alimentation Votre confiance
MODULES ÉLECTRIQUES - systèmes électriques DC - onduleurs - convertisseurs - interrupteurs statiques Notre alimentation Votre confiance Système Power 1UDC+ Jusqu à 38 redresseurs et un contrôleur, 1266A
Plus en détailApplication Form/ Formulaire de demande
Application Form/ Formulaire de demande Ecosystem Approaches to Health: Summer Workshop and Field school Approches écosystémiques de la santé: Atelier intensif et stage d été Please submit your application
Plus en détailRelais d'arrêt d'urgence, protecteurs mobiles
PNOZ Relais jusqu'en d'arrêt 11 catégorie d'urgence, 4, EN 954-1 protecteurs mobiles Bloc logique de sécurité pour la surveillance de poussoirs d'arrêt d'urgence et de protecteurs mobiles Homologations
Plus en détailEditing and managing Systems engineering processes at Snecma
Editing and managing Systems engineering processes at Snecma Atego workshop 2014-04-03 Ce document et les informations qu il contient sont la propriété de Ils ne doivent pas être copiés ni communiqués
Plus en détailFonctions intégrées. Nouvelles solutions universelles & système de communication
Fonctions intégrées Nouvelles solutions universelles & système de communication avec les nouvelles solutions universelles Hazemeyer... avancez d une génération thanks to the new flexible solutions by Hazemeyer...
Plus en détailASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat
ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat SKU 2728089 INSTRUCTIONAL MANUAL MANUEL D'INSTRUCTIONS 270/2707 COMPONENT LIST LISTE DES
Plus en détailASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré
ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré SKU 2711592 INSTRUCTIONAL MANUAL MANUEL D'INSTRUCTIONS 270/2707 COMPONENT LIST LISTE
Plus en détailINSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks
INSTRUMENTS DE MESURE SOFTWARE SOFTWARE Logiciel de supervision des réseaux locaux et/ou distants Management software for remote and/or local monitoring networks MIDAs EVO 4 niveaux de fonctionnalités
Plus en détailCompléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :
FOIRE AUX QUESTIONS COMMENT ADHÉRER? Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante : 275, boul des Braves Bureau 310 Terrebonne (Qc) J6W 3H6 La
Plus en détailStratégie DataCenters Société Générale Enjeux, objectifs et rôle d un partenaire comme Data4
Stratégie DataCenters Société Générale Enjeux, objectifs et rôle d un partenaire comme Data4 Stéphane MARCHINI Responsable Global des services DataCenters Espace Grande Arche Paris La Défense SG figures
Plus en détailPVCHECK Rel. 2.02 09/11/12
Metel: HV000PVC Pag 1 of 5 Multifunction instrument for safety, functionality and performance verifications on a PV plant The multifunction instrument PVCHECK performs prompt and safe electrical checks
Plus en détailDOCUMENTATION - FRANCAIS... 2
DOCUMENTATION MODULE SHOPDECORATION MODULE PRESTASHOP CREE PAR PRESTACREA INDEX : DOCUMENTATION - FRANCAIS... 2 INSTALLATION... 2 Installation automatique... 2 Installation manuelle... 2 Résolution des
Plus en détailLE FORMAT DES RAPPORTS DU PERSONNEL DES COMMISSIONS DE DISTRICT D AMENAGEMENT FORMAT OF DISTRICT PLANNING COMMISSION STAFF REPORTS
FORMAT OF DISTRICT PLANNING COMMISSION STAFF REPORTS LE FORMAT DES RAPPORTS DU PERSONNEL DES COMMISSIONS DE DISTRICT D AMENAGEMENT A Guideline on the Format of District Planning Commission Staff Reports
Plus en détailNEW Fin Fan / Air cooled condenser cleaning
Air cooled Condensers ( ACC ) Cleaning Air Cooled heat exchangers ( Finfan) Cleaning Cleaning Services Permanente installation NEW Fin Fan / Air cooled condenser cleaning New and revolutionnary high pressure
Plus en détailCHARGEURS AUTOMATIQUES DE BATTERIE AUTOMATIC BATTERY CHARGERS
CHARGEURS AUTOMATIQUES DE BATTERIE AUTOMATIC BATTERY CHARGERS CN.D 10-24 N4 md CPN.D 20-24 N4 Capoté/Covered CE.D 05-24 N4 mm Série BRAVO (CE.D-CN.D-CPN.D/E) (CMV agrée VÉRITAS) BRAVO (CE.D-CN.D-CPN.D/E)
Plus en détailTechnique de sécurité
Technique de sécurité SAFEMASTER PRO Système de sécurité configurable Module d'entrée /-sortie UG 696.0 0668 Les avantages du SAFEMASTER PRO Pour applications sécuritaires jusqu à PLe, Catégorie, et SIL
Plus en détailSystème ASC unitaire triphasé. PowerScale 10 50 kva Maximisez votre disponibilité avec PowerScale
Système ASC unitaire triphasé 10 50 kva Maximisez votre disponibilité avec Protection de première qualité est un système ASC triphasé de taille moyenne qui offre une protection électrique remarquable pour
Plus en détailNatixis Asset Management Response to the European Commission Green Paper on shadow banking
European Commission DG MARKT Unit 02 Rue de Spa, 2 1049 Brussels Belgium markt-consultation-shadow-banking@ec.europa.eu 14 th June 2012 Natixis Asset Management Response to the European Commission Green
Plus en détailAPPENDIX 6 BONUS RING FORMAT
#4 EN FRANÇAIS CI-DESSOUS Preamble and Justification This motion is being presented to the membership as an alternative format for clubs to use to encourage increased entries, both in areas where the exhibitor
Plus en détailGestion des prestations Volontaire
Gestion des prestations Volontaire Qu estce que l Income Management (Gestion des prestations)? La gestion des prestations est un moyen de vous aider à gérer votre argent pour couvrir vos nécessités et
Plus en détailThank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.
Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed. Note: This manual describes the appearance of the USB Stick, as well as the
Plus en détailsur le réseau de distribution
EDF-R&D Département MIRE et Département EFESE 1, avenue du Général de Gaulle 92141 Clamart Impact qualité du site photovoltaïque "Association Soleil Marguerite" sur le réseau de distribution Responsable
Plus en détailMANUEL MARKETING ET SURVIE PDF
MANUEL MARKETING ET SURVIE PDF ==> Download: MANUEL MARKETING ET SURVIE PDF MANUEL MARKETING ET SURVIE PDF - Are you searching for Manuel Marketing Et Survie Books? Now, you will be happy that at this
Plus en détailRèglement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation
THE CONSUMER PROTECTION ACT (C.C.S.M. c. C200) Call Centres Telemarketing Sales Regulation LOI SUR LA PROTECTION DU CONSOMMATEUR (c. C200 de la C.P.L.M.) Règlement sur le télémarketing et les centres d'appel
Plus en détailMonitor LRD. Table des matières
Folio :1/6 Table des matières 1.Installation du logiciel... 3 2.Utilisation du logiciel... 3 2.1.Description de la fenêtre de commande... 3 2.1.1.Réglage des paramètres de communication... 4 2.1.2.Boutons
Plus en détailGAME CONTENTS CONTENU DU JEU OBJECT OF THE GAME BUT DU JEU
GAME CONTENTS 3 wooden animals: an elephant, a Polar bear and an African lion 1 Playing Board with two tree stumps, one red and one blue 1 Command Board double sided for two game levels (Green for normal
Plus en détailRéférences pour la commande
avec fonction de détection de défaillance G3PC Détecte les dysfonctionnements des relais statiques utilisés pour la régulation de température des éléments chauffants et émet simultanément des signaux d'alarme.
Plus en détail7200S FRA. Contacteur Statique. Manuel Utilisateur. Contrôle 2 phases
7200S Contacteur Statique FRA Contrôle 2 phases Manuel Utilisateur Chapitre 2 2. INSTALLATI Sommaire Page 2.1. Sécurité lors de l installation...............................2-2 2.2. Montage.................................................2-3
Plus en détailOnce the installation is complete, you can delete the temporary Zip files..
Sommaire Installation... 2 After the download... 2 From a CD... 2 Access codes... 2 DirectX Compatibility... 2 Using the program... 2 Structure... 4 Lier une structure à une autre... 4 Personnaliser une
Plus en détailARCHOS Activity Tracker
ARCHOS Activity Tracker «Archos Connected Self» Application Connecté pour votre confort L'ARCHOS Activity Tracker synchronise automatiquement votre activité quotidienne à votre smartphone ou votre tablette
Plus en détailComfort Duett. TV-kit. www.comfortaudio.com. USA: English/Français/Español. Comfort Duett
Comfort Duett TV-kit USA: English/Français/Español www.comfortaudio.com Comfort Duett 1 English The television kit makes it possible to amplify the sound from the TV via the charger unit. As soon as Comfort
Plus en détailTHE LAW SOCIETY OF UPPER CANADA BY-LAW 19 [HANDLING OF MONEY AND OTHER PROPERTY] MOTION TO BE MOVED AT THE MEETING OF CONVOCATION ON JANUARY 24, 2002
2-aes THE LAW SOCIETY OF UPPER CANADA BY-LAW 19 [HANDLING OF MONEY AND OTHER PROPERTY] MOTION TO BE MOVED AT THE MEETING OF CONVOCATION ON JANUARY 24, 2002 MOVED BY SECONDED BY THAT By-Law 19 [Handling
Plus en détailDOCUMENTATION - FRANCAIS... 2
DOCUMENTATION MODULE CATEGORIESTOPMENU MODULE CREE PAR PRESTACREA INDEX : DOCUMENTATION - FRANCAIS... 2 INSTALLATION... 2 CONFIGURATION... 2 LICENCE ET COPYRIGHT... 3 SUPPORT TECHNIQUE ET MISES A JOUR...
Plus en détailRELAIS STATIQUE. Tension commutée
RELAIS STATIQUE Nouveau Relais Statique Monophasé de forme compacte et économique Coût réduit pour une construction modulaire Modèles disponibles de 15 à 45 A Modèles de faible encombrement, avec une épaisseur
Plus en détailAPPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder
Page 1 APPENDIX 2 Provisions to be included in the contract between the Provider and the Obligations and rights of the Applicant / Holder Holder 1. The Applicant or Licensee acknowledges that it has read
Plus en détailDOCUMENTATION MODULE BLOCKCATEGORIESCUSTOM Module crée par Prestacrea - Version : 2.0
DOCUMENTATION MODULE BLOCKCATEGORIESCUSTOM Module crée par Prestacrea - Version : 2.0 INDEX : DOCUMENTATION - FRANCAIS... 2 1. INSTALLATION... 2 2. CONFIGURATION... 2 3. LICENCE ET COPYRIGHT... 3 4. MISES
Plus en détailRelais statiques SOLITRON MIDI, Commutation analogique, Multi Fonctions RJ1P
Relais statiques SOLITRON MIDI, Commutation analogique, Multi Fonctions RJ1P Relais statique CA Multi fonctions - 5 sélections de modes de fonctionnement: angle de phase, trains d ondes distribuées et
Plus en détailTM238LDA24DR 230VAC - RELAYS OUTPUTS -
Fiche produit Caractéristiques TM238LDA24DR 230VAC - RELAYS OUTPUTS - Complémentaires Logique d'entrée numérique Nombre de points communs Alimentation électrique du capteur Tension état 1 garanti Courant
Plus en détailQuick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.
Rational ClearCase or ClearCase MultiSite Version 7.0.1 Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite. Product Overview IBM Rational
Plus en détailQuick Installation Guide TEW-AO12O
Quick Installation Guide TEW-AO12O Table of of Contents Contents Français... 1 1. Avant de commencer... 1 2. Installation du matériel... 2 3. Montage... 4 Troubleshooting... 6 Version 10.04.2007 1. Avant
Plus en détailMode d emploi ALTO MONITOR PROCESSEUR D ÉCOUTE. www.altoproaudio.com Version 1.0 Juillet 2003 Français
Mode d emploi ALTO MONITOR PROCESSEUR D ÉCOUTE www.altoproaudio.com Version 1.0 Juillet 2003 Français SOMMAIRE 1. INTRODUCTION................................................................... 4 2. FONCTIONNALITÉS................................................................
Plus en détailARP-090G / ARP-090K NOTICE D'EMPLOI INSTRUCTION MANUAL
2 7 NOTICE D'EMPLOI INSTRUCTION MANUAL ARP-090G / ARP-090K Lire attentivement la notice avant d utiliser l appareil Before operating this product, please read user manual completely FRANCAIS EMPLACEMENT
Plus en détailPackage Contents. System Requirements. Before You Begin
Package Contents DWA-125 Wireless 150 USB Adapter CD-ROM (contains software, drivers, and manual) Cradle If any of the above items are missing, please contact your reseller. System Requirements A computer
Plus en détailWEB page builder and server for SCADA applications usable from a WEB navigator
Générateur de pages WEB et serveur pour supervision accessible à partir d un navigateur WEB WEB page builder and server for SCADA applications usable from a WEB navigator opyright 2007 IRAI Manual Manuel
Plus en détailFirst Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION
CANADA CONSOLIDATION CODIFICATION First Nations Assessment Inspection Regulations Règlement sur l inspection aux fins d évaluation foncière des premières nations SOR/2007-242 DORS/2007-242 Current to September
Plus en détailIgloo. Congélateurs Ultra-Froid -45 o C & -86 o C Armoires & Coffres 370 à 830 litres
Igloo Congélateurs Ultra-Froid -45 o C & -86 o C Armoires & Coffres 370 à 830 litres Igloo Plus d échantillons, moins d encombrement L espace dans un laboratoire est précieux. C o n t r a i r e m e n t
Plus en détailfullprotect inside EOLE SPEie RS E-SPEie 0.5-12-5V-0.6A-RS 1.0 revision Protection environnement Datasheet édition française
Protection environnement Datasheet édition française 1.0 revision R-D-CO-D-27112011-1.0-C fullprotect inside SPEi Protection environnement interne SPEe Protection environnement externe SPEc Contrôle de
Plus en détailExercices sur SQL server 2000
Exercices sur SQL server 2000 La diagramme de classe : Exercices sur SQL server 2000 Le modèle relationnel correspondant : 1 Créer les tables Clic-droit on Tables et choisir «New Table» Créer la table
Plus en détailStérilisation / Sterilization
CONTENEURS Ecoster ecoster CONTAINERS Stérilisation / Sterilization Les conteneurs Ecoster aluminium sont prévus pour contenir des instruments et/ou des tissus pendant toute la durée de la stérilisation
Plus en détailPrincipe de TrueCrypt. Créer un volume pour TrueCrypt
Sommaire : Principe de TrueCrypt...1 Créer un volume pour TrueCrypt...1 Premier montage...6 Réglages...8 Save Currently Mounted Volumes as Favorite...8 Settings > Preferences...9 TrueCrypt Traveller pour
Plus en détailGuide d'installation rapide TFM-560X YO.13
Guide d'installation rapide TFM-560X YO.13 Table of Contents Français 1 1. Avant de commencer 1 2. Procéder à l'installation 2 Troubleshooting 6 Version 06.08.2011 16. Select Install the software automatically
Plus en détailONTARIO Court File Number. Form 17E: Trial Management Conference Brief. Date of trial management conference. Name of party filing this brief
ONTARIO Court File Number at (Name of court) Court office address Form 17E: Trial Management Conference Brief Name of party filing this brief Date of trial management conference Applicant(s) Full legal
Plus en détailINVESTMENT REGULATIONS R-090-2001 In force October 1, 2001. RÈGLEMENT SUR LES INVESTISSEMENTS R-090-2001 En vigueur le 1 er octobre 2001
FINANCIAL ADMINISTRATION ACT INVESTMENT REGULATIONS R-090-2001 In force October 1, 2001 LOI SUR LA GESTION DES FINANCES PUBLIQUES RÈGLEMENT SUR LES INVESTISSEMENTS R-090-2001 En vigueur le 1 er octobre
Plus en détailInstitut français des sciences et technologies des transports, de l aménagement
Institut français des sciences et technologies des transports, de l aménagement et des réseaux Session 3 Big Data and IT in Transport: Applications, Implications, Limitations Jacques Ehrlich/IFSTTAR h/ifsttar
Plus en détailExemple PLS avec SAS
Exemple PLS avec SAS This example, from Umetrics (1995), demonstrates different ways to examine a PLS model. The data come from the field of drug discovery. New drugs are developed from chemicals that
Plus en détailArchived Content. Contenu archivé
ARCHIVED - Archiving Content ARCHIVÉE - Contenu archivé Archived Content Contenu archivé Information identified as archived is provided for reference, research or recordkeeping purposes. It is not subject
Plus en détailThis is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems
NORME INTERNATIONALE INTERNATIONAL STAN DARD CEI IEC 870-3 Première édition First edition 1989-03 Matériels et systèmes de téléconduite Troisième partie: Interfaces (caractéristiques électriques) Telecontrol
Plus en détailARDUINO DOSSIER RESSOURCE POUR LA CLASSE
ARDUINO DOSSIER RESSOURCE POUR LA CLASSE Sommaire 1. Présentation 2. Exemple d apprentissage 3. Lexique de termes anglais 4. Reconnaître les composants 5. Rendre Arduino autonome 6. Les signaux d entrée
Plus en détailETABLISSEMENT D ENSEIGNEMENT OU ORGANISME DE FORMATION / UNIVERSITY OR COLLEGE:
8. Tripartite internship agreement La présente convention a pour objet de définir les conditions dans lesquelles le stagiaire ci-après nommé sera accueilli dans l entreprise. This contract defines the
Plus en détailLogitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation
Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation English.......................................... 3 Français.........................................
Plus en détailAND / ET USER GUIDE UK HARDWIRED CONTROL PANEL UK GUIDE UTILISATEUR CENTRALE D ALARME FILAIRE F 496572 1
AND / ET UK USER GUIDE HARDWIRED CONTROL PANEL UK F GUIDE UTILISATEUR CENTRALE D ALARME FILAIRE 496572 1 English UK Operator Controls and Displays On both control panel and remote keypad the LEDs display
Plus en détailModules d automatismes simples
Modules d automatismes simples Solutions pour automatiser Modules d'automatismes Enfin, vraiment simple! Un concentré de solution Pour vos petites applications d'automatismes millenium gère : Temporisations
Plus en détail