INSTALLATION INSTRUCTIONS 1x4 Troffer Retrofit Kit VR44-MU-295-xyy-1400A VR44-MU-295-xyy-1050A VR44-MU-295-xyy-0700A VR44-MU-195-xyy-0700A

Documents pareils
ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Paxton. ins Net2 desktop reader USB

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Lavatory Faucet. Instruction Manual. Questions?

Contrôle d'accès Access control. Notice technique / Technical Manual

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Notice Technique / Technical Manual

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

Guide d'installation rapide TFM-560X YO.13

SYSTÈME JETS D AIR WISH WISH AIR JETS SYSTEM Système de massage à jets d air pour bains en polymère - Air jet massage system for polymer bathtubs

Instructions Mozilla Thunderbird Page 1

Contents Windows

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Archived Content. Contenu archivé

Warning: Failure to follow these warnings could result in property damage, or personal injury.

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Folio Case User s Guide

Package Contents. System Requirements. Before You Begin

WEB page builder and server for SCADA applications usable from a WEB navigator

Le No.1 de l économie d énergie pour patinoires.

R.V. Table Mounting Instructions

Stainless Steel Solar Wall Light

Fabricant. 2 terminals

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

BILL 203 PROJET DE LOI 203

User guide Conference phone Konftel 100

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

If the corporation is or intends to become a registered charity as defined in the Income Tax Act, a copy of these documents must be sent to:

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Contrôle d accès Access control MOD-TCPIP-AI. Notice technique / Technical Manual

GASKET FOR TONER COLLECTION BOTTLE

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

LE FORMAT DES RAPPORTS DU PERSONNEL DES COMMISSIONS DE DISTRICT D AMENAGEMENT FORMAT OF DISTRICT PLANNING COMMISSION STAFF REPORTS

FOURTH SESSION : "MRP & CRP"

INDIVIDUALS AND LEGAL ENTITIES: If the dividends have not been paid yet, you may be eligible for the simplified procedure.

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

DOCUMENTATION - FRANCAIS... 2

Ocs Inventory et GLPI s appuie sur un serveur LAMP. Je vais donc commencer par installer les paquets nécessaires.

Gestion des prestations Volontaire

86 rue Julie, Ormstown, Quebec J0S 1K0

Monitor LRD. Table des matières

Logitech Speaker System Z553 Setup Guide Guide d installation

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

22/09/2014 sur la base de 55,03 euros par action

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Once the installation is complete, you can delete the temporary Zip files..

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

MODE D EMPLOI USER MANUAL

FCM 2015 ANNUAL CONFERENCE AND TRADE SHOW Terms and Conditions for Delegates and Companions Shaw Convention Centre, Edmonton, AB June 5 8, 2015

Spécial Catégorie 6 Patch Cords

Below are the answers to question(s) submitted in regards to the above noted RFP as of August 5 th, 2014

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

PRACTICE DIRECTION ON THE LENGTH OF BRIEFS AND MOTIONS ON APPEAL

DOCUMENTATION - FRANCAIS... 2

Practice Direction. Class Proceedings

How to Login to Career Page

Utiliser une WebCam. Micro-ordinateurs, informations, idées, trucs et astuces

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

SERVEUR DÉDIÉ DOCUMENTATION

Sécurité relative aux sièges auto et aux rehausseurs

UNIVERSITY OF MALTA FACULTY OF ARTS. French as Main Area in an ordinary Bachelor s Degree

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

SYSTÈME DE GAINES À SPIRALE ET RACCORDS TOURNANTS

Principe de TrueCrypt. Créer un volume pour TrueCrypt

Lesson Plan Physical Descriptions. belle vieille grande petite grosse laide mignonne jolie. beau vieux grand petit gros laid mignon

Le Tour de Bretagne à la Voile est une épreuve de catégorie 3 des RSO. En cas de traduction de cet avis de course, le texte français prévaudra

Embases pour raccordement G1/8 - G1/4

APPENDIX 6 BONUS RING FORMAT

Application Form/ Formulaire de demande

INTERNATIONAL CONSULTANT & SUPPLIERS TO THE WINE & SPIRITS TRADE

Free filter reminders! Sign up online at: santevia.com/filterease. need help? Contact Santevia!

Exercices sur SQL server 2000

Water Quality Information Management for Atlantic, Ontario, Manitoba, Pacific and Saskatchewan Regions

Scénarios économiques en assurance

Grandes tendances et leurs impacts sur l acquisition de produits et services TI.

Quick Installation Guide TEW-AO12O

CHANGE GUIDE France- Monaco- Guyana- Martinique- Guadeloupe- Reunion- Mayotte

RICHEL SERRES DE FRANCE PAR_ _02432_ALT DATE: 03/02/2012

ETABLISSEMENT D ENSEIGNEMENT OU ORGANISME DE FORMATION / UNIVERSITY OR COLLEGE:

PVCHECK Rel /11/12

POLICY: FREE MILK PROGRAM CODE: CS-4

Discours du Ministre Tassarajen Pillay Chedumbrum. Ministre des Technologies de l'information et de la Communication (TIC) Worshop on Dot.

Guide pour l Installation des Disques Durs SATA et Configuration RAID

Laboratory accredited by the French Home Office (official gazette date February 5 th, 1959, modified) Valid five years from August 27 th, 2013

Manuel d'utilisation

Summary / Sommaire. 1 Install DRIVER SR2 USB01 Windows seven 64 bits / Installation du DRIVER SR2 USB01 Windows seven 64 bits 2

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

MASSEY COLLEGE & UNIVERSITY OF TORONTO

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

Innovation in Home Insurance: What Services are to be Developed and for what Trade Network?

INSTRUCTIONS. Comment compléter le formulaire. How to complete this form. Instructions

Transcription:

INSTALLATION INSTRUCTIONS 1x4 Troffer Retrofit Kit VR44-MU-295-xyy-1400A VR44-MU-295-xyy-1050A VR44-MU-295-xyy-0700A VR44-MU-195-xyy-0700A Installation Instructions subject to change without notice. Page 1 of 7

2. 6. 7. 0 INSTALLATION WARNINGS "THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND HAZARDS INVOLVED. WARNING - Risk of fire or electric shock. LED Retrofit kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. WARNING - Risk of fire or electric shock. Install this kit only in the luminaires that has the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire. WARNING - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. WARNING Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components." "CAUTION RISK OF FIRE. CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR." THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY THE AUTHORITIES HAVING JURISDICTION. 8. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. 2. 6. 7. 8. 0 AVERTISSEMENTS D'INSTALLATION CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D'INSTALLATION PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS. AVERTISSEMENT - Risque d incendie ou de choc électrique. L installation de ce nécessaire de modernisation exige une personne familière avec la construction et le fonctionnement du système électrique du luminaire et des risques associés. Toute personne qui n est pas qualifiée ne doit faire aucune tentative d installation et doit contacter une personne qualifiée. AVERTISSEMENT - Risque d incendie ou de choc électrique. N installer ce nécessaire que dans les luminaires don't les caractéristiques de construction et les dimensions sont conforme à celles illustrées dans les photos et/ou les dessins et dont la puissance d entrée nominale du nécessaire de modernisation ne dépasse pas celle du luminaire. AVERTISSEMENT - Afin de prévenir l endommagement ou l abrasion des câbles, éviter tout contact entre ces derniers et le bord d un objet tranchant tel qu une tôle. AVERTISSEMENT -Risk d'incendie ou de choc électrique. Le câblage du luminaire et les pièces électriques peuvent être endommagés lors du forage pour l'installation d'un kit de reconditionnement LED. Vérifiez le câblage et les composants inclus. " ATTENTION RISQUE D'INCENDIE, CONSULTER UN ÉLECTRICIEN QUALIFIÉ POUR VOUS ASSURER QUE LES CONDUCTEURS DE LA DÉRIVATION SONT ADÉQUATS. LE NÉCESSAIRE DE MODERNISATION EST ACCEPTÉ À TITRE DE COMPOSANT D UN LUMINAIRE LORSQUE LA PERTINENCE DE LA COMBINAISON DOIT ËTRE DÉTERMINÉE PAR PAR LES AUTORITÉS COMPÉTENTES. Ne faites pas ou ne modifiez aucun trou ouvert dans une enceinte de câblage ou de composants électriques pendant l'installation du kit Installation Instructions subject to change without notice. Page 2 of 7

2.0 ORIGINAL LUMINAIRE DIMENSIONS Original Luminaire (Lithonia: GT8 1 X4 ) Minimum Luminaire Dimensions Dimensions are inches (centimeters) 4-1/2 (14cm) 12 (30.5cm) 4-1/2 (14cm) 48 (128cm) Remove all the original luminaire parts, hardware, lamp, and ballast in order to begin the retrofit. Original luminaire diffuser and original ground wire will need to be kept for this retrofit. This Kit can be retrofitted into any luminaire with a similar length/height width greater than or equal to the Minimum Luminaire Dimensions described above. 0 RETROFIT KIT COMPONENTS Retrofit kit components will be provided as listed below: LED Modules LED Diffuser Lens LED Diffuser End Caps LED Driver LED Harness (Optional) (Optional) Mounting Hardware WARNING: Risk of fire and electrical shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components. Avertissement: Risque d' incendie et d'électrocution. câblage des luminaires et pièces électriques peuvent être endommagés lors du forage pour l'installation du kit de conversion à DEL. Vérifier le câblage et les composants ci-joint Retrofit Warning Label Input Voltage: 120-AC (50/60Hz) Ph:(323) 599-5001 Input Current: x. xxxa @120VAC DATE CODE www.fulham.com Suitable for Dry or Damp Locations Name Plate Label 0 RECOMMENDED TOOLS (Not Included) Power Drill W/ Philips Bit Installation Instructions subject to change without notice. Page 3 of 7

0 RETROFIT KIT DESCRIPTION A B C D E WARNING: Risk of fire and electrical shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components. Avertissement: Risque d' incendie et d'électrocution. câblage des luminaires et pièces électriques peuvent être endommagés lors du forage pour l'installation du kit de conversion à DEL. Vérifier le câblage et les composants ci-joint F G H Ph:(323) 599-5001 www.fulham.com Input Voltage: 120-AC (50/60Hz) Input Current: x. xxxa @120VAC Suitable for Dry or Damp Locations DATE CODE ITEM DESCRIPTION QTY A. LED Modules *2 B. LED Driver 1 C. LED Harness: TLC-HN02 1 D. 6-20 X 3/8 Pan Head Self Drilling Screws *14 E. Retrofit Warning Label 1 F. LED Module Lens: TLE-OPT-120-013 (Optional) *2 G. LED Module Lens End Cap: TLE-OPT-120-020 (Optional) *4 H. Name Place Label 1 *Note: Item quantity will vary based on retrofit kit model purchased. Please refer to retrofit kit spec sheet for more details. Installation Instructions subject to change without notice. Page 4 of 7

6.0 ORIGINAL LUMINAIRE DISASSEMBLY Start by removing the Lens from the luminaire. See Picture # Picture #1 2. Remove the lamps and the ballast/driver channel cover from the luminaire. See Picture #2. Remove the original ballast and lamp sockets from the luminaire. See Picture # Picture #2 The original ground wire and ballast/driver channel cover will need to be kept for this retrofit. Luminaire should look like Picture #3 in order to begin the retrofit. Picture #3 Installation Instructions subject to change without notice. Page 5 of 7

7.0 RETROFIT KIT ASSEMBLY Start by Placing the LED Modules (A) onto the luminaire as shown on Figure Note: If kit includes LED Module Lens (F) install the LED Module Lens (F) before placing the LED Module onto the Luminaire. 2. Secure the LED Modules to the luminaire Figure 1 using the provided 6-20 x3/8 Pan Head Self Drilling Screws (D). See Figure LED module with lens installed Affix the Retrofit Warning Label (E) in the area where it can be visible during the LED Driver installation. See Figure 2. Place the LED Driver (B) on the location shown on Figure 2. Secure the LED Driver (B) to the luminaire using the original screw. If the original screw is not available, use provided 6-20 x 3/8 Pan Head Self Drilling Screws (D). See Figure 2. Figure 2 WARNING: Risk of fire and electrical shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components. Avertissement: Risque d' incendie et d'électrocution. câblage des luminaires et pièces électriques peuvent être endommagés lors du forage pour l'installation du kit de conversion à DEL. Vérifier le câblage et les composants ci-joint 6. Wire the LED driver output wires to LED module input connectors using the provided LED Harness (C). See Figure 7. Wire the LED driver input wires to the power source. See Figure 3 and refer to the Connecting Power To The Retrofit Kit section of Page 7 for appropriate wiring instructions. Figure 3 Installation Instructions subject to change without notice. Page 6 of 7

Ph:(323) 599-5001 www.fulham.com Ph:(323) 599-5001 www.fulham.com Input Voltage: 120-AC (50/60Hz) Input Current: x. xxxa @120VAC Suitable for Dry or Damp Locations Input Voltage: 120-AC (50/60Hz) Input Current: x. xxxa @120VAC Suitable for Dry or Damp Locations DATE CODE DATE CODE 7.0 RETROFIT KIT ASSEMBLY 8. Place the provided Name Plate Label (H) on the luminaire in a readily visible location to anyone attempting to service the luminaire. See Figure 4-A. 9. Replace the ballast/driver channel cover and Figure 4 - A luminaire lens. See Figure 4-A and Figure Note: if kit included Module Lens then the completed retrofit should look like Figure 4- B and Figure Figure 4 - B 10. Completed retrofit should look like Figure Figure 5 1) Connecting Power to the Retrofit Kit: Connect the green wire (Ground) from the luminaire to the Ground that is being fed by the power source. Connect these two wires by using a wire connector with a minimum 18AWG rating. 2) 3) Connect the white wire (Neutral) from the LED Driver to the Neutral being fed by the power source. Connect these two wires by using a wire connector with a minimum 18AWG rating. Connect the black wire (Line) from LED Driver to the Line being fed by the power source. Connect these two wires by using a wire connector with a minimum 18AWG rating. 8.0 WARRANTY Please refer to LinearHO kit spec sheet for warranty information Installation Instructions subject to change without notice. Page 7 of 7