User s instruction 2 Notice d'utilisation 5

Documents pareils
Notice Technique / Technical Manual

Contrôle d'accès Access control. Notice technique / Technical Manual

Paxton. ins Net2 desktop reader USB

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Guide d'installation rapide TFM-560X YO.13

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

ARP-090G / ARP-090K NOTICE D'EMPLOI INSTRUCTION MANUAL

How to Login to Career Page

Instructions Mozilla Thunderbird Page 1

Once the installation is complete, you can delete the temporary Zip files..

Folio Case User s Guide

AUTO ER ADAPT ER SPECIAL USE WARNING

AMC 120 Amplificateur casque

SERIE TS-770 SYSTEME CONFERENCE

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Logitech Speaker System Z553 Setup Guide Guide d installation

User guide Conference phone Konftel 100

Fabricant. 2 terminals

Master4Light. Caractérisation Optique et Electrique des Sources Lumineuses. Equipement 2-en-1 : source de courant et spectrophotomètre

Gestion des prestations Volontaire

Spécial Catégorie 6 Patch Cords

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

MANUEL MARKETING ET SURVIE PDF

Guide d installation Comment raccorder mon modem?

WEB page builder and server for SCADA applications usable from a WEB navigator

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

CEST POUR MIEUX PLACER MES PDF

DOCUMENTATION - FRANCAIS... 2

Micro-ordinateurs, informations, idées, trucs et astuces utiliser le Bureau à distance

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

Practice Direction. Class Proceedings

Contrôle d accès Access control MOD-TCPIP-AI. Notice technique / Technical Manual

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Package Contents. System Requirements. Before You Begin

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

MANUEL D INSTRUCTION

Monitor LRD. Table des matières

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

USB 598. Quick Start Guide (Windows) Guide de démarrage rapide (Windows) USB Modem. Modem USB.

Boîtier disque dur SATA 3,5 pouces Fonction économie d énergie

DGA. Self Contained Digicode Keypad Digicode avec électronique intégrée INSTALLATION MANUAL MANUEL D INSTALLATION. Group Company

SERVEUR DÉDIÉ DOCUMENTATION

Moteur DC: Comment faire varier sa vitesse?

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

PRESENTATION REMOTE TÉLÉCOMMANDE DE PRÉSENTATION. User Guide Manuel de l utilisateur

fullprotect inside EOLE SPEie RS E-SPEie V-0.6A-RS 1.0 revision Protection environnement Datasheet édition française

DOCUMENTATION - FRANCAIS... 2

Le No.1 de l économie d énergie pour patinoires.

Quick Installation Guide TBW-106UB H/W: V1

Contents Windows

Principe de TrueCrypt. Créer un volume pour TrueCrypt

Institut français des sciences et technologies des transports, de l aménagement

Garage Door Monitor Model 829LM

Get Instant Access to ebook Cest Maintenant PDF at Our Huge Library CEST MAINTENANT PDF. ==> Download: CEST MAINTENANT PDF


F1 Security Requirement Check List (SRCL)

PROJECT POUR LE SYSTÈME DE SURVEILLANCE PAR CAMERA BASÉ SUR TECHNOLOGIE AXIS, PANNEAUX SOLAIRES ET LUMIERE DU LEDS BLOC D APARTEMENT LAURIER.

Quick Installation Guide TEW-P21G

epowerswitch 8XM+ Fiche technique

lundi 3 août 2009 Choose your language What is Document Connection for Mac? Communautés Numériques L informatique à la portée du Grand Public

AVOB sélectionné par Ovum

Restaurant Application Quick Reference Guide

Manuel de l utilitaire Computer Setup (F10) HP Compaq Business Desktops Modèles d220 et d230

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

Description du logiciel Modbus RTU

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

/ / / Système de distribution audio A44/A88 Logiciel PC

Fonctions intégrées. Nouvelles solutions universelles & système de communication

MEMORANDUM POUR UNE DEMANDE DE BOURSE DE RECHERCHE DOCTORALE DE LA FONDATION MARTINE AUBLET

DELL E6500 : Remplacement du disque dur d origine par un disque dur chiffrant

UMG 20CM. UMG 20CM Appareil de surveillance des circuits de distribution avec 20 entrées et RCM. Analyse d harmoniques RCM. Gestion d alarmes.

Surveillance de Scripts LUA et de réception d EVENT. avec LoriotPro Extended & Broadcast Edition

ONTARIO Court File Number. Form 17E: Trial Management Conference Brief. Date of trial management conference. Name of party filing this brief

I. COORDONNÉES PERSONNELLES / PERSONAL DATA

Stainless Steel Solar Wall Light

Credit Note and Debit Note Information (GST/ HST) Regulations

Unité centrale de commande Watts W24

«BOREAL 20» MODE D EMPLOI / USER MANUAL REF S.A HENRI DEPAEPE

DOCUMENTATION - FRANCAIS... 2

Application Form/ Formulaire de demande

Sécurité relative aux sièges auto et aux rehausseurs

Utiliser une WebCam. Micro-ordinateurs, informations, idées, trucs et astuces

Logitech Wireless Performance Combo MX800 Setup Guide Guide d installation

MODE D EMPLOI USER MANUAL

Lesson Plan Physical Descriptions. belle vieille grande petite grosse laide mignonne jolie. beau vieux grand petit gros laid mignon

Filtres maîtres et distribués ADSL

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

domovea tebis La maison sous contrôle

Bravo! Vous venez d acquérir un routeur large bande à 4 ports Conceptronic C100BRS4H.

Improving the breakdown of the Central Credit Register data by category of enterprises

Transcription:

PFS 6 Master TFR User s instruction 2 Notice d'utilisation 5

User s instruction The PFS 6 Master TFR was designed to give the highest degree of protection against overloads, voltage peaks, electromagnetic interference (EMI) and radio frequency interference (RFI). It is provided with an ingenious "Master/Slave" energy saving function. It protects your computers, peripherals and hi-fi equipment against damage caused by voltage peaks, lightning, network parasites and overloads. It also protects your phone /fax/modem equipment. A reset circuit breaker protects against overloads and blowouts. Insurance terms and conditions See terms and conditions and register on the web site: www.infosec.fr Security Please read all these instructions before installing the PFS 6 Master TFR. It must be installed only inside a protected location in which the temperature and humidity do not exceed the limits defined in the technical characteristics section. Description 6 5 9 4 3 1 2 8 7 NB: Please refer to numbers 1 to 9 in next paragraph. Installation Plug the PFS 6 Master TFR into a connector with earth (2P+E 10 A). Check that the «Protected» and «Power ok» lights are on. Put the switch into the «manual» or «auto» position depending on your choice. 1. Mains switch You can use the switch to select automatic "master/slave" mode or "manual" mode to switch on the six power outlets. In "master/slave" mode, connect the main equipment (for example computer) to the "master" power outlet and the peripheral equipment to the other "slave" connectors ; the on or off state of your main equipment will automatically activate ( slave ON LED is on) or deactivate ( slave ON LED is off) the power supply to the slave power outlets. In manual mode, all power outlets are powered and the slave ON and power OK LEDs are turned on. 2 Hot Line : tel : + 33 (0)2 40 76 15 82 - fax : + 33 (0)2 40 94 29 51 - hotline@infosec.fr - 06 05 08 205 17

WARNING: The internal clock in some hi-fi equipment can be deactivated if the equipment is connected to a "slave" power outlet. 2. Overload protection When the consumption of connected equipment exceeds the authorized value, the temperature switch opens to protect the PFS 6 Master TFR. To put it back into service, reduce the power and reset the circuit breaker. 3. Active surge protection indicator: Protected Green LED Protected turns on : the protection is effective. Green LED Protected is off: the protection is not effective. 4. Electrical power supply indicator: Power OK Green LED Power OK turns on : the PFS 6 Master TFR is powered. Green LED Power OK is off : the PFS 6 Master TFR is not powered. 5. Electrical power supply indicator for "slave" power outlets: Slave ON Red LED Slave ON turns on : slave power outlets are powered. Red LED Slave ON is off : slave power outlets are not powered. 6. "Master" power outlets In master/slave" mode, the master power outlets must be used to connect the main equipment that will control the power supply of equipment connected to the slave power outlets. In "manual" mode, the large spacing between power outlets facilitates the connection of a transformer. 7. "Slave" power outlets Slave power outlets are used to connect peripheral equipment such as a printer, monitor, scanner, modem, removable disks, CD Rom, etc. In "master/slave" mode, these power outlets will only be powered if the main equipment connected to the «master» power outlet is itself powered. 8. Fax and Modem protection The PFS 6 Master TFR is equipped with protection against overvoltages on the telephone /fax/modem line (2 RJ 11-6P4C). Connect the line input to the ''IN'' connector and use the cable supplied to connect the ''OUT'' connector to the telephone /fax /modem. 9. Adjustment of the switching limit (potentiometer) If your computer, when switched on the "master" plug, is in standby function, the slave plugs might remain fed after the switching off of your computer. In that case, when the computer is off, increase little by little the value of the potentiometer until one gets back to the master/slave function. If there is a problem, do not disassemble the PFS 6 Master TFR, there are no reparable parts inside it. Please, call the hot line. Hot Line : tel : + 33 (0)2 40 76 15 82 - fax : + 33 (0)2 40 94 29 51 - hotline@infosec.fr - 06 05 08 205 17 3

Technical specifications GENERAL SPECIFICATIONS 1 protected outlet Master with child-proof safety shutters 5 protected outlets Slave with child-proof safety shutters 10A resettle circuit breaker Durable fire prevention plastic housing Dimensions (hxwxd) (mm) : 255 x 115 x 40 Weight : 700 g Cable length : 1,8 meters French type outlets Conform with the CE standard Lifetime warranty ELECTRICAL SPECIFICATIONS Nominal voltage 200-250 VAC Clamping voltage 800 Volts "Master" power outlet : 575 Watts / 2.5 A Maximum Power "Slave" power outlets : 2300 Watts / 10 A Surge energy rating 918 Joules (H-N, H-G, N-G) Peak current 8/20 µs 36 000 A (12 000 A x 3 lines) Response time < 1 nanosecond EMI/RFI FILTER Frequency range 150 khz ~ 100 MHz Attenuation 40 db LIGHT INDICATORS Green "Protected" Protection device active Green "Power OK" PFS 6 Master TFR outlet powered Red "Slave ON" "Slave" power outlets powered PHONE - FAX - MODEM -xdsl PROTECTION Jacks 2 RJ11 (6P4C) Peak voltage 395 Volts Maximum surge energy 160 Joules ENVIRONMENT Temperature 0 to 40 Celsius Relative humidity 0 to 95 % relative humidity 4 Hot Line : tel : + 33 (0)2 40 76 15 82 - fax : + 33 (0)2 40 94 29 51 - hotline@infosec.fr - 06 05 08 205 17

Notice d'utilisation La PFS 6 Master TFR a été conçue pour offrir le plus haut degré de protection contre les surcharges, les pointes de tension, les perturbations électromagnétiques (EMI) et les interférences de fréquence radio (RFI). Elle dispose d'une astucieuse fonction "Maître/Esclave" qui permet de faire des économies d'énergie. La PFS 6 Master TFR protège vos ordinateurs et périphériques contre les dommages occasionnés par les pics de tension, la foudre, les parasites du réseau et les surcharges. Un disjoncteur ré-armable protège contre les surcharges et courts-circuits. Termes et conditions d assurance Sécurité Voir conditions de garantie et formulaire d enregistrement sur le site web : www.infosec.fr Veuillez lire toutes ces instructions avant d'installer la PFS 6 Master TFR. Elle doit être installée uniquement à l'intérieur dans un endroit protégé où la température et l'humidité n'excèdent pas les limites précisées dans la section des caractéristiques techniques. Description 6 5 9 4 3 1 2 8 7 NB: Merci de vous référer aux numéros 1 à 9 dans le paragraphe suivant. Installation Branchez la PFS 6 Master TFR à une prise avec mise à la terre (2P+T 10A). Vérifiez que les voyants Protected et Power OK soient allumés. Placez l interrupteur en position manual ou auto selon votre choix. 1. Interrupteur marche/arrêt L interrupteur vous permet de sélectionner le mode automatique maître/esclave ou bien le mode manuel» de mise sous tension des 6 prises. En mode maître/esclave, branchez l équipement principal (ordinateur par exemple) sur la prise master et les équipements périphériques sur les autres prises esclaves : l état allumé ou éteint de votre équipement principal activera (voyant slave ON allumé) ou désactivera (voyant slave ON éteint) automatiquement l alimentation des prises esclaves. En mode manuel, toutes les prises sont alimentées et les voyants slave ON et power OK sont allumés. Hot Line : tel : + 33 (0)2 40 76 15 82 - fax : + 33 (0)2 40 94 29 51 - hotline@infosec.fr - 06 05 08 205 17 5

ATTENTION : L horloge interne de certains appareils hi-fi peut se désactiver s ils sont connectés à une prise esclave. 2. Protection de surcharge Lorsque la consommation des appareils raccordés dépasse la valeur autorisée, le disjoncteur s'ouvre pour protéger la PFS 6 Master TFR. Pour remettre en service, réduisez la puissance branchée et appuyez sur le bouton reset". 3. Voyant de protection de surtension : Protected Voyant vert Protected allumé : la protection est efficace. Voyant Protected éteint : la protection est hors-service. 4. Voyant d alimentation électrique : Power OK Voyant Power OK vert allumé : la PFS 6 Master TFR est alimentée. Voyant Power OK éteint : la PFS 6 Master TFR n est pas alimentée. 5. Voyant d alimentation électrique pour prises esclaves : Slave ON Voyant rouge Slave ON allumé : les prises esclaves : sont alimentées. Voyant Slave ON éteint : les prises esclaves : ne sont pas alimentées. 6. Prise Maître En mode Maître/Esclave elle doit être utilisée pour brancher l équipement principal qui conditionnera l alimentation des équipements connectés sur les prises esclaves. En mode manual, son positionnement espacé permet le branchement d un transformateur. 7. Prises Esclaves Elles sont utilisées pour le raccordement des appareils périphériques tels que imprimante, moniteur, scanner, modem, disques amovibles, CD Rom, etc. En mode maître/esclave, elles ne sont alimentées que si l équipement principal connecté sur la prise master est lui-même sous tension. 8. Protection Fax et Modem La PFS 6 Master TFR est équipée d'une protection contre les surtensions pour ligne téléphone/fax/ modem (2 RJ 11 6P4C). Branchez l'arrivée de la ligne sur la prise ''IN'' et utilisez le câble fourni pour la liaison de la prise ''OUT'' au téléphone/fax/modem. 9. Réglage fonction veille en mode master/slave Si votre ordinateur connecté sur la prise ''Master'' dispose d une fonction veille, il se peut que les prises esclaves restent alimentées après l arrêt de votre ordinateur. Dans ce cas, lorsque l ordinateur est éteint augmenter petit à petit la valeur du potentiomètre jusqu à la restitution de la fonction maître/esclave. En cas de problème, ne démontez pas la PFS 6 Master TFR, il n'y a pas pièce à l'intérieur qui puisse être réparée. Merci de contacter le Service Après Vente (Hot Line). 6 Hot Line : tel : + 33 (0)2 40 76 15 82 - fax : + 33 (0)2 40 94 29 51 - hotline@infosec.fr - 06 05 08 205 17

Spécifications techniques SPECIFICATIONS GENERALES 1 prise protégée Master avec sécurité enfant 5 prises protégées Esclaves avec sécurité enfant Disjoncteur réenclenchable 10 Ampères Boîtier plastique ininflammable Fixation murale possible Dimensions (hxlxp) (mm) : 255 x 115 x 40 Poids : 700 g Longueur du câble : 1,8 mètres Conformité à la norme CE SPECIFICATIONS ELECTRIQUES Tension nominale 200-250 VAC Tension d écrêtage 800 Volts Prise "Master" : 575 Watts / 2.5 A Puissance maximum Prises "Slave" : 2300 Watts / 10 A Ecoulement entre pôles 918 Joules (P-N, P-T, N-T) Ecoulement 8/20 µs 36 000 A (12 000 A x 3 lignes) Temps de réponse < 1 nanoseconde FILTRE EMI/RFI Plage de fréquence 150 khz ~ 100 MHz Atténuation jusqu à 40 db TEMOINS LUMINEUX "Protected" vert Dispositif de protection actif "Power OK" vert PFS 6 Master TFR alimentée "Slave ON" rouge Prises "esclaves" alimentées PROTECTION TELEPHONE - FAX - MODEM -xdsl Prises 2 RJ11 (6P4C) Tension d'écrêtage 395 Volts Ecoulement maximum 160 Joules ENVIRONNEMENT Température 0 to 40 Celsius Humidité 0 to 95 % Hot Line : tel : + 33 (0)2 40 76 15 82 - fax : + 33 (0)2 40 94 29 51 - hotline@infosec.fr - 06 05 08 205 17 7