User Guide. EasyView Digital Light Meter. Model EA31



Documents pareils
USER GUIDE. Video Borescope. Model BR100

User's Manual. Digital Sound Level Meter. Model

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

Lavatory Faucet. Instruction Manual. Questions?

Quick start guide. HTL1170B

J. Nexera Distribution assembly instructions consignes d assemblage instrucciones de ensamblaje

worldwide limited warranty and technical support

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Notice Technique / Technical Manual

Practice Direction. Class Proceedings

PAR RINOX INC BY RINOX INC PROGRAMME D INSTALLATEUR INSTALLER PROGRAM

Paxton. ins Net2 desktop reader USB

Le No.1 de l économie d énergie pour patinoires.

Contrôle d'accès Access control. Notice technique / Technical Manual

Package Contents. System Requirements. Before You Begin

Folio Case User s Guide

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

Fabricant. 2 terminals

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

86 rue Julie, Ormstown, Quebec J0S 1K0

Warning: Failure to follow these warnings could result in property damage, or personal injury.

LG Electronics, Inc. Display Limited Warranty - USA

Trim Kit Installation Instruction

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Monitor LRD. Table des matières

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

POLICY: FREE MILK PROGRAM CODE: CS-4

PRESENTATION REMOTE TÉLÉCOMMANDE DE PRÉSENTATION. User Guide Manuel de l utilisateur

Stainless Steel Solar Wall Light

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

AUTO ER ADAPT ER SPECIAL USE WARNING

SERVEUR DÉDIÉ DOCUMENTATION

KitchenAid Blender_ War_r_anty for_ the 50 United States, the Distr_ict of Columbia, Puer_to Rico, and Canada

Nouveautés printemps 2013

Archived Content. Contenu archivé

Guide d'installation rapide TFM-560X YO.13

WEB page builder and server for SCADA applications usable from a WEB navigator

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

Owner's Manual RSB-1410

Le Cloud Computing est-il l ennemi de la Sécurité?

Please kindly find below a synoptic table showing the various ways of transport from Mahe to La Digue, with a stop over on Praslin:

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

DOCUMENTATION MODULE BLOCKCATEGORIESCUSTOM Module crée par Prestacrea - Version : 2.0

MASTER LOCK PRODUCT LIMITED LIFETIME WARRANTY

How to Login to Career Page

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Quick Installation Guide TEW-AO12O

60 LED ULTRA BRIGHT SOLAR MOTION LIGHT PROJECTEUR SOLAIRE DE 60 DEL ULTRA BRILLANTES À DETECTEUR DE MOUVEMENT

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

Instructions Mozilla Thunderbird Page 1

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

If the corporation is or intends to become a registered charity as defined in the Income Tax Act, a copy of these documents must be sent to:

FCM 2015 ANNUAL CONFERENCE AND TRADE SHOW Terms and Conditions for Delegates and Companions Shaw Convention Centre, Edmonton, AB June 5 8, 2015

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Multiple issuers. La cotation des actions ROBECO ci-dessous est suspendue sur EURONEXT PARIS dans les conditions suivantes :

PAR_ _09543_EUR DATE: 17/12/2014. Suite à l'avis PAR_ _08654_EUR

ENGLISH 4 FRANÇAIS 6 ESPAÑOL 8

12, Chemin de la Forge L Islet (Québec) G0R 1X0 CANADA

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Humidimètre sans contact avec mémoire + Thermomètre IR

PVCHECK Rel /11/12

Gestion des prestations Volontaire

CEST POUR MIEUX PLACER MES PDF

Application Form/ Formulaire de demande

SunATM 4.0 Release Notes

We Generate. You Lead.

QUALITY INNOVATION SERVICE VALUE 2910ACS 2910MC MODEL. Can we help you? THE BUSH BUSINESS FURNITURE difference A157536

DOCUMENTATION - FRANCAIS... 2

OUVRIR UN COMPTE CLIENT PRIVÉ

BILL 203 PROJET DE LOI 203

Principe de TrueCrypt. Créer un volume pour TrueCrypt

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

Z-Axis Compliance Device Compliance en z

Contents Windows

33 inch open & closed storage Rangement à espace fermé et ouvert de 33po (83.7cm) 33 pulgadas almacenaje abierto y cerra

Quick Installation Guide TW100-BRV304

CETTE FOIS CEST DIFFERENT PDF

Guide d installation Deco Drain inc. DD200

Discours du Ministre Tassarajen Pillay Chedumbrum. Ministre des Technologies de l'information et de la Communication (TIC) Worshop on Dot.

Subject to the terms of this Agreement, Adobe hereby grants you a nonexclusive,

RAPID Prenez le contrôle sur vos données

INDIVIDUALS AND LEGAL ENTITIES: If the dividends have not been paid yet, you may be eligible for the simplified procedure.

Grandes tendances et leurs impacts sur l acquisition de produits et services TI.

Guide d'installation rapide TK-803R TK-1603R

PROJET DE LOI. An Act to Amend the Employment Standards Act. Loi modifiant la Loi sur les normes d emploi

THE EVOLUTION OF CONTENT CONSUMPTION ON MOBILE AND TABLETS

I. COORDONNÉES PERSONNELLES / PERSONAL DATA

Get Instant Access to ebook Cest Maintenant PDF at Our Huge Library CEST MAINTENANT PDF. ==> Download: CEST MAINTENANT PDF

AIDE FINANCIÈRE POUR ATHLÈTES FINANCIAL ASSISTANCE FOR ATHLETES

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

MANUEL MARKETING ET SURVIE PDF

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Swap: Utilisation et risques Approche de gestion pour les consommateurs

DOCUMENTATION - FRANCAIS... 2

AND / ET USER GUIDE UK HARDWIRED CONTROL PANEL UK GUIDE UTILISATEUR CENTRALE D ALARME FILAIRE F

LOI SUR LE RÉGIME D ASSURANCE COLLECTIVE DE LA FONCTION PUBLIQUE PUBLIC SERVICE GROUP INSURANCE BENEFIT PLAN ACT

Transcription:

User Guide EasyView Digital Light Meter Model EA31

Introduction Thank you for selecting the Extech EasyView Digital Light Meter which measures the amount of light falling on a surface (illuminance) in Foot-candles or Lux. This device measures up to 20,000 Fc and 20,000 Lux. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit the Extech Instruments website () to check for the latest version of this User Guide. Extech Instruments is an ISO-9001 certified company. Meter Description 1. LCD display 2. Range button 3. Power ON/OFF button 4. lux / fc selection button 5. Data HOLD button 6. MAX/MIN button 7. Photo sensor (lens cover not shown) (Tripod mounts on rear of sensor) Note: Battery compartment is located on the rear of the instrument Spectral Sensitivity 2

Operation Power ON or OFF Press the button to turn power on or off. Units of measure Press the lux / fc button to select the unit of measure. fc or lux will appear in the display. Light sensor 1. The light sensor is attached to the meter with a coiled cable which allows placement of the sensor up to approximately 3 feet from the meter. 2. The light sensor is a silicon photo diode and resides under the white domed lens. 3. To protect the lens from scratches, keep the protective cap on the sensor whenever the unit is not in use. 4. The back of the sensor has a tripod mounting hole. Taking measurements 1. Remove the protective cap from the sensor. 2. Place the sensor in a horizontal position at the measurement location. 3. Read the light level on the display. If the light measurement is out of range an OL indication will appear on the display. If the OL appears, select a higher range by pressing the RANGE button. MX MN Function 1. Press the MX/MN button once to put the meter in MX/MN mode. The meter will now display the highest reading that occurs while the function is enabled. The MAX icon will appear in the display. 2. Press the MX/MN button again to display the lowest reading that occurs while the function is enabled. The MIN icon will appear in the display. 3. Press MX/MN again to toggle between the MAX and MIN readings. 4. To exit the MX MN mode and return to the normal real time display, press and hold the MX/MN button (2 seconds) until the MAX and MIN icons disappear. Data Hold Press the HOLD button to freeze the displayed reading. The 'H' hold icon will appear on the display. Press the HOLD button again to return to normal operation. 3

Reference Foot candles Lux Typical Light Levels >10000 >107600 Sunlight 1000 to 10000 10760 to 107600 Operating Table 100 to 1000 1076 to 10760 Assembly (fine) Football stadium Emergency room Drafting table 10 to 100 107 to 1076 Overcast day Assembly (general) Classroom Casual reading Shipping area Stairwell Auditorium 1 to 10 10.7 to 107 ATM machine Storage room Building entrance Parking lot 0 to 1 0 to 10.7 Highway Full moon Foot-candle / Lux conversion 1 lux =.09290 foot-candles 1 foot-candle = 10.764 lux 4

Maintenance Cleaning and storage 1. The white plastic sensor dome should be cleaned with a damp cloth when necessary. 2. Store the meter in an area with moderate temperature and humidity (refer to the operating and storage range in the specifications chart earlier in this manual). Battery Replacement When the battery voltage is low the BT symbol will appear on the display. Replace the six (6) 1.5 AAA batteries by removing the rear (center) battery compartment screw and accessing the battery compartment. Observe polarity when placing the batteries in the compartment. Ensure that the compartment cover is securely fastened when finished. Please dispose of batteries responsibly. Specifications Lux 20.00 200.0 2000 Ranges Resolution Accuracy 0.01 0.1 1 ± (3% Reading + 0.5% Full Scale) 20.00kLux 0.01 if > 10,000 lux ±( 4% Reading + 0.5%Full Scale) Foot candles 20.00 200 2000, 20.00kfc 0.01 0.1 1 0.01 ± (3% Reading + 0.5% Full Scale) if > 1,000 fc ±( 4% Reading + 0.5%Full Scale) 5

General Specifications Display 3-1/2 digit, 2000 count LCD Over range indication LCD displays OL Spectral response CIE photopic (CIE human eye response curve), Cosine corrected Spectral accuracy CIE V function (f 1 6%) Measurement Repeatability ±2% Calibration Calibrated to a standard incandescent lamp at color temperature 2856ºK Temperature coefficient ±0.1% per o C Sampling rate 2.5 times per second Photo detector Silicon photo-diode and spectral response filter Operating conditions Temperature: 32 to 104 o F (0 to 40 o C); Humidity: < 80% RH Storage conditions Temperature: 14 to 140 o F (-10 to 50 o C); Humidity: < 80% RH Dimensions 5.91 x 2.8 x 1.4" (150 x 72 x 35mm) Weight Approx. 11.3 oz. (320g) with battery Photo Detector Dimensions 3.62 x 2.36 x 1.14 (92 x 60 x 29mm) Detector cable length 3 (91cm) approximately Low battery indication BT appears on the LCD Power supply 6 AAA cells; Battery life approx 400 hours 6

Warranty FLIR Systems, Inc. warrants this Extech Instruments brand device to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department for authorization. Visit the website for contact information. A Return Authorization (RA) number must be issued before any product is returned. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. FLIR Systems, Inc. specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. FLIR s total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration, Repair, and Customer Care Services FLIR Systems, Inc. offers repair and calibration services for the Extech Instruments products we sell. NIST certification for most products is also provided. Call the Customer Service Department for information on calibration services available for this product. Annual calibrations should be performed to verify meter performance and accuracy. Technical support and general customer service is also provided, refer to the contact information provided below. Support Lines: U.S. (877) 439 8324; International: +1 (603) 324 7800 Technical Support: Option 3; E mail: support@extech.com Repair & Returns: Option 4; E mail: repair@extech.com Product specifications are subject to change without notice Please visit our website for the most up to date information FLIR Commercial Systems, Inc., 9 Townsend West, Nashua, NH 03063 USA ISO 9001 Certified Copyright 2013 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form 7

Garantie FLIR Systems, Inc. garantit que cet appareil Extech Instruments est exempt de défauts matériaux et de fabrication pendant un an à partir de la date d envoi (une garantie limitée de six mois s applique aux capteurs et aux câbles). Si le renvoi de l appareil pour réparation devient nécessaire durant ou après la période de garantie, contactez le service client pour autorisation. Pour obtenir les coordonnées, visitez le site Web suivant :. Un numéro d autorisation de retour (AR) doit être délivré avant tout retour de produit. L expéditeur prend à sa charge les frais d expédition, le fret, l assurance et l emballage correct de l appareil afin de prévenir toute détérioration durant le transport. Cette garantie ne s applique pas aux dommages imputables à l utilisateur, tels que l usage impropre ou abusif, un mauvais câblage, une utilisation non conforme aux spécifications, un entretien ou une réparation incorrecte, ou toute modification non autorisée. FLIR Systems, Inc. déclinera spécifiquement toute garantie ou qualité marchande ou aptitude à l emploi prévu, et ne sera en aucun cas tenu responsable pour tout dommage conséquent, direct, indirect ou accidentel. La responsabilité totale de FLIR est limitée à la réparation ou au remplacement du produit. La garantie définie ci dessus est inclusive et aucune autre garantie, écrite ou orale, n est exprimée ou implicite. Calibrage, réparation et services après vente FLIR Systems, Inc. offre des services de calibrage et de réparation pour les produits Extech Instruments que nous commercialisons. Nous fournissons également une certification NIST pour la plupart des produits. Contactez notre service client pour toute information sur les services de calibrage disponibles pour ce produit. Un calibrage doit être effectué chaque année pour vérifier les performances et la précision du mètre. Nous offrons également une assistance technique et un service à la clientèle. Veuillez vous reporter aux coordonnées fournies ci dessous. Lignes d assistance: États Unis (877) 439 8324; international: +1 (603) 324 7800 Service d assistance technique : Option 3 ; E mail : support@extech.com Réparations et retours : Option 4 ; E mail : repair@extech.com Les spécifications produit sont sujettes à modifications sans préavis. Pour les toutes dernières informations, veuillez visiter notre site Web. FLIR Commercial Systems, Inc., 9 Townsend West, Nashua, NH 03063 USA Certifié ISO 9001 Copyright 2013 FLIR Systems, Inc. Tous droits réservés, y compris la reproduction partielle ou totale sous quelque forme que ce soit. 8

Garantía FLIR Systems, Inc., garantiza este dispositivo marca Extech Instruments para estar libre de defectos en partes o mano de obra durante un año a partir de la fecha de embarque (se aplica una garantía limitada de seis meses para cables y sensores). Si fuera necesario regresar el instrumento para servicio durante o después del periodo de garantía, llame al Departamento de Servicio a Clientes para obtener autorización. Visite para Información de contacto. Se debe expedir un número de Autorización de Devolución (AD) antes de regresar cualquier producto. El remitente es responsable de los gastos de embarque, flete, seguro y empaque apropiado para prevenir daños en tránsito. Esta garantía no se aplica a defectos resultantes de las acciones del usuario como el mal uso, alambrado equivocado, operación fuera de las especificaciones, mantenimiento o reparación inadecuada o modificación no autorizada. FLIR Systems, Inc., rechaza específicamente cualesquier garantías implícitas o factibilidad de comercialización o idoneidad para cualquier propósito determinado y no será responsable por cualesquier daños directos, indirectos, incidentales o consecuentes. La responsabilidad total de FLIR está limitada a la reparación o reemplazo del producto. La garantía precedente es inclusiva y no hay otra garantía ya sea escrita u oral, expresa o implícita. Servicios de calibración, reparación y atención a clientes FLIR Systems, Inc., ofrece servicios de reparación y calibración para los productos que vendemos de Extech Instruments. Además ofrecemos certificación NIST para la mayoría de los productos. Llame al Departamento de Servicio al Cliente para solicitar información de calibración para este producto. Para verificar el funcionamiento y precisión se debe realizar la calibración anual. Además se provee Soporte Técnico y servicios generales al cliente, consulte la información de contacto en seguida. Líneas de soporte: EE.UU. (877) 439 8324; Internacional: +1 (603) 324 7800 Soporte Técnico Opción 3; correo electrónico: support@extech.com Reparación / Devoluciones: Opción 4; correo electrónico: repair@extech.com Las especificaciones del producto están sujetas a cambios sin aviso Por favor visite nuestra página en Internet para la información más actualizada FLIR Commercial Systems, Inc., 9 Townsend West, Nashua, NH 03063 USA Certificado ISO 9001 Copyright 2013 FLIR Systems, Inc. Reservados todos los derechos, incluyendo el derecho de reproducción total o parcial en cualquier medio 9