50033841 LP Gas and 50033842 Natural Gas Conversion Kits



Documents pareils
Lavatory Faucet. Instruction Manual. Questions?

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Contrôle d'accès Access control. Notice technique / Technical Manual

Garage Door Monitor Model 829LM

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Package Contents. System Requirements. Before You Begin

Manuel d utilisation du modèle

R.V. Table Mounting Instructions

Paxton. ins Net2 desktop reader USB

Notice Technique / Technical Manual

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Fabricant. 2 terminals

Le No.1 de l économie d énergie pour patinoires.

Instructions Mozilla Thunderbird Page 1

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

GRILLE AU GAZ CB-70M & CB-105M GAS CHAR-BROILER

Vanne de mélange DirectConnect série AMX300

APPENDIX 6 BONUS RING FORMAT

Folio Case User s Guide

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Guide d'installation rapide TFM-560X YO.13

Nouveautés printemps 2013

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Principe de TrueCrypt. Créer un volume pour TrueCrypt

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

MODE D EMPLOI USER MANUAL

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

Monitor LRD. Table des matières

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

Contents Windows

Embases pour raccordement G1/8 - G1/4

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Stainless Steel Solar Wall Light

Logitech Speaker System Z553 Setup Guide Guide d installation

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

Warning: Failure to follow these warnings could result in property damage, or personal injury.

POLICY: FREE MILK PROGRAM CODE: CS-4

Contrôle d accès Access control MOD-TCPIP-AI. Notice technique / Technical Manual

Free filter reminders! Sign up online at: santevia.com/filterease. need help? Contact Santevia!

Utiliser une WebCam. Micro-ordinateurs, informations, idées, trucs et astuces

How to Login to Career Page

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

Procédures de conversion de gaz Modèles des séries VCS3008, VCS4008, VCS5008

accidents and repairs:

NEW Fin Fan / Air cooled condenser cleaning

Manuel de l utilisateur Dispositif d utilisation hivernale DUH À utiliser uniquement avec le modèle GSWH-1

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

VTP. LAN Switching and Wireless Chapitre 4

PARIS ROISSY CHARLES DE GAULLE

WEB page builder and server for SCADA applications usable from a WEB navigator

Guide de démarrage rapide

AND / ET USER GUIDE UK HARDWIRED CONTROL PANEL UK GUIDE UTILISATEUR CENTRALE D ALARME FILAIRE F

MANUEL D INSTRUCTIONS K-STAR ÉLECTRIQUE Chauffe-piscine/spa électrique

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Maximum Capacity / Capacité maximal: 10 kg/min

lundi 3 août 2009 Choose your language What is Document Connection for Mac? Communautés Numériques L informatique à la portée du Grand Public

SYSTÈME JETS D AIR WISH WISH AIR JETS SYSTEM Système de massage à jets d air pour bains en polymère - Air jet massage system for polymer bathtubs

FCM 2015 ANNUAL CONFERENCE AND TRADE SHOW Terms and Conditions for Delegates and Companions Shaw Convention Centre, Edmonton, AB June 5 8, 2015

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

ARP-090G / ARP-090K NOTICE D'EMPLOI INSTRUCTION MANUAL

Propriétés de la matière. Material properties. Sonde de pression Pressure probe. Ref : Français p 1. English p 3.

Quick Setup Guide Guide de configuration rapide. Tablet Device SGPT12 Series Tablette électronique Série SGPT12

Sécurité relative aux sièges auto et aux rehausseurs

AIDE FINANCIÈRE POUR ATHLÈTES FINANCIAL ASSISTANCE FOR ATHLETES

Credit Note and Debit Note Information (GST/ HST) Regulations

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

Lesson Plan Physical Descriptions. belle vieille grande petite grosse laide mignonne jolie. beau vieux grand petit gros laid mignon

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

THE LAW SOCIETY OF UPPER CANADA BY-LAW 19 [HANDLING OF MONEY AND OTHER PROPERTY] MOTION TO BE MOVED AT THE MEETING OF CONVOCATION ON JANUARY 24, 2002

Application Form/ Formulaire de demande

BILL 203 PROJET DE LOI 203

Guide d installation Deco Drain inc. DD200

Instructions d'utilisation

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

DOCUMENTATION - FRANCAIS... 2

Bill 69 Projet de loi 69

Gestion des prestations Volontaire

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

DOCUMENTATION - FRANCAIS... 2

GASKET FOR TONER COLLECTION BOTTLE

FO-FDHB6-1 Central Heat Blower Kit for Onyx, Opel and Delta

Quick Installation Guide TEW-AO12O

FÉDÉRATION INTERNATIONALE DE NATATION Diving

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

ETABLISSEMENT D ENSEIGNEMENT OU ORGANISME DE FORMATION / UNIVERSITY OR COLLEGE:

OWNER S MANUAL 4 US GALLONS (15.1 LITERS) OUTPUT PER DAY WARM MOISTURE HUMIDIFIER 3 US GALLONS (11.3 LITERS) OUTPUT PER DAY WARM MOISTURE HUMIDIFIERS

Le passé composé. C'est le passé! Tout ça c'est du passé! That's the past! All that's in the past!

CARACTÉRISTIQUES GÉNÉRALES MODÈLE A. De fabrication robuste, il est composé d un réservoir en acier doux où en acier inoxydable (stainless steel).

has brought a motion to change the order of Justice, dated. the agreement between you and (name of party bringing this motion), dated.

SERVEUR DÉDIÉ DOCUMENTATION

Tutoriel de formation SurveyMonkey

Critères à l attention des fabricants et des fournisseurs de biens ou de services : dispositifs mécaniques pour bingo

Practice Direction. Class Proceedings

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Transcription:

50033841 LP Gas and 50033842 Natural Gas Conversion Kits FOR VR9205 TWO-STAGE COMBINATION GAS CONTROLS APPLICATION The 50033841 LP Conversion Kit changes the VR9205 two-stage family combination gas controls from regulated natural gas to regulated LP gas. The 50033842 Natural Gas Conversion Kit changes the VR9205 two-stage family combination gas controls from regulated LP gas to regulated natural gas. Kits include two pressure regulator adjustment screws, two springs, two regulator cap screws, and a conversion label. To use this kit, assure gas control is equipped with a two stage pressure regulator. NOTE: Single stage, modulating, and gas-air valves cannot be converted with this kit. WARNING Fire or Explosion Hazard. Can cause property damage, severe injury or death. Follow these warnings exactly: 1. To avoid dangerous accumulation of fuel gas, turn off the gas supply at the appliance service valve before starting installation, and perform Gas Leak Test after installation is complete. 2. Do not force the gas control switch. Use only your hand to turn the gas control switch. Never use any tools. If gas control switch will not operate by hand, then a qualified technician should replace the gas control. Force or attempted repair may result in fire or explosion. INSTALLATION INSTRUCTIONS on LP gas, or a gas control set for LP gas on natural (or manufactured) gas. Follow the appliance manufacturer instructions if available; otherwise, use these instructions as a guide. WARNING Fire or Explosion Hazard. Can cause property damage, severe injury or death. Perform Gas Leak Test every time work is done on a gas system. Install Regulator Conversion Kits 1. Turn off gas supply at the appliance service valve. 2. Remove regulator cap screws and pressure regulator adjusting screws from Hi and Lo Regulator Towers. Refer to Fig. 1. 3. Remove the existing Regulator Springs from towers. 4. Insert the replacement Regulator Springs in both towers. Refer to Fig. 2. 5. Install the new plastic pressure regulator adjustment screws to both towers. Refer to Fig. 2. 6. Turn gas supply to the appliance back on. 7. Adjust the high regulator setting before adjusting the lower setting using a manometer or by clocking the gas meter. Make sure the appliance is on high fire while adjusting the high regulator. See Output Calibration section following. 8. Install new regulator cap screws in both towers. 9. Mount conversion label on the gas control. 10. Leak test the gas valve. See Gas Leak Test section following. WARNING Electrical Shock or Equipment Damage Hazard. Can cause severe injury or death or short equipment circuitry. Disconnect power supply before installation. LOW REGULATOR ADJUSTMENT SCREW UNDER CAP ON/OFF SWITCH Always change the main and pilot burner orifices when converting from natural to LP gas or from LP to natural gas. Carefully follow appliance manufacturer specifications and instructions to assure proper appliance conversion. Gas controls are factory-set for natural (or manufactured) or LP gas. Do not attempt to use a gas control set for natural (or manufactured) gas HIGH REGULATOR ADJUSTMENT SCREW UNDER CAP VENT PORT M29750 Fig. 1. Conversion kit installation regulator. 69-2395EF-01

50033841 LP GAS AND 50033842 NATURAL GAS CONVERSION KITS STARTUP ON/OFF Switch Settings a. OFF: Prevents main gas flow. b. ON: Permits gas to flow through the control body to the main burner under control of the ignition system. Turn On System Slide the on-off switch to the ON position. Turn On Main Burner Follow appliance manufacturer instructions or turn thermostat up to call for heat. Output Calibration OUTLET PRESSURE TAP Fig. 2. Gas conversion kit. Fig. 3. Gas conversion kit: outlet. Fig. 4. Gas conversion kit: inlet. M29754 M29751 TERMINALS INLET PRESSURE TAP M29752 IMPORTANT 1. Do not exceed input rating stamped on appliance nameplate or manufacturer's recommended burner orifice pressure for size orifice(s) used. Make certain primary air supply to main burner is properly adjusted for complete combustion. Follow appliance manufacturer instructions. 2. IF CHECKING GAS INPUT BY CLOCKING GAS METER: Make certain there is no gas flow through the meter other than to the appliance being checked. Other appliances must remain off with the pilots extinguished (or deduct their consumption from the meter reading). Convert flow rate to Btuh as described in form 70-2602, Gas Controls Handbook, and compare to Btuh input rating on appliance nameplate. 3. IF CHECKING GAS INPUT WITH MANOME- TER: Make sure the gas control is in the OFF position before removing outlet pressure tap plug to connect manometer (pressure gauge). Also move the gas control switch back to the OFF position when removing the gauge and replacing the plug. Before removing inlet pressure tap plug, shut off gas supply at the manual valve in the gas piping to the appliance or, for LP, at the tank. Also shut off gas supply before disconnecting manometer and replacing plug. Repeat Gas Leak Test at plug with main burner operating. NOTE: Check the inlet pressure before adjusting the pressure regulator. Two-stage VR9205 requires that you check and adjust both high and low pressure regulator settings. Two-stage appliances operating sequences vary. Consult the appliance manufacturer instructions for the specific operating sequence and regulator adjustment procedure for the appliance in which the control was installed. 1. Consult the appliance manufacturer's instruction to obtain the high and low fire regulator pressure settings. 2. Install the springs and regulator adjustment screws as per the conversion instruction above. 3. Set appliance to operate on high fire. 4. With main burner operating on high fire, calibrate the high fire regulator setting using the meter clocking method or using a manometer connected to the outlet pressure tap on the control. See Fig. 3. 69-2395EF 01 2

50033841 LP GAS AND 50033842 NATURAL GAS CONVERSION KITS a. Adjust the high pressure regulator to match the appliance rating. b. See Table 1 for the adjustment range of the gas valve. The appliance requirements should be within this range. c. Using a screwdriver, turn the Hi adjustment screw clockwise to increase or counterclockwise to decrease the gas pressure to the burner. 5. After high pressure has been calibrated, calibrate the low pressure regulator using the same measurement method. Two-stage appliance operating sequences vary. Consult the appliance manufacturer instructions for the specific operating sequence which the control is installed and for instructions on how to prevent the control from moving to high stage while calibrating the low pressure regulator setting. 6. With main burner operating on low fire, calibrate the low fire regulator setting using the meter clocking method or using a manometer connected to the outlet pressure tap on the control. See Fig. 3. a. Adjust the low pressure regulator to match the appliance rating. b. See Table 1 for the adjustment range of the gas valve. The appliance requirements should be within this range. c. Using a screwdriver, turn the Lo adjustment screw clockwise to increase or counterclockwise to decrease the gas pressure to the burner. 7. Once high and low pressure regulator settings have been calibrated and verified, install the new pressure regulator adjustment caps. 8. If the desired outlet pressure or flow rate cannot be achieved by adjusting the gas control, check the gas control inlet pressure using a manometer at the inlet pressure tap of the gas control. See Fig. 4. If the inlet pressure is in the nominal range (see Table 1), replace the gas control. Otherwise, take the necessary steps to provide proper gas pressure to the control. 9. Replace pressure tap plugs. 10. Mount conversion label on the gas control. 11. Leak test the gas valve. See Gas Leak Test section following. Table 1. Pressure Regulator Specification Pressures (in. wc). Model Type Two- Stage Type of Gas Nominal Inlet Pressure Range Factory Set Nominal Outlet Pressure NAT 5.0-7.0 1.7 Low 3.5 High LP 12.0-14.0 4.9 Low 10.0 High Adjustment Range 0.6-3.0 Low 3.0-5.0 High 2.5-7.0 Low 8.0-11.0 High Perform Gas Leak Test WARNING Fire or Explosion Hazard. Can cause property damage, severe injury or death. Perform Gas Leak Test every time work is done on a gas system. IMPORTANT Do not spray soap and water solution on the gas control. Do not use an excessive amount of soap and water solution to perform the gas leak test. These can damage the control. Gas Leak Test 1. Paint pipe connections upstream of the gas control with rich soap and water solution. Bubbles indicate a gas leak. 2. If a leak is detected, tighten the pipe connections. 3. Light the main burner. Stand clear of the main burner while lighting to prevent injury caused from hidden leaks that could cause flashback in the appliance vestibule. 4. With the main burner in operation, paint the pipe joints (including bushings) and the control inlet and outlet with rich soap and water solution. 5. If another leak is detected, turn the gas control to off, tighten the joints and pipe connections. 6. Replace the part if a leak cannot be stopped. CHECKOUT 1. Make certain the primary air supply to the main burner is properly adjusted for complete combustion at the final pressure regulator setting. The main burner must light reliably under all conditions. 2. Place the system in operation and observe through at least one complete cycle to assure all controls are operating properly. a. Carefully check the main burner lightoff. Make sure that the main burner lights smoothly and that all ports remain lighted. b. Check the full rate (high) manifold pressure listed on the appliance nameplate for high pressure. The gas control full rate outlet pressure should match this rating. c. Check the low rate (low) manifold pressure listed on the appliance nameplate for low pressure. The gas control low rate outlet pressure should match the rating. 3. If manometer (pressure gauge) method is used, reinstall pressure tap plugs and perform Gas Leak Test at inlet and outlet pressure tap plugs. See Fig. 3 and 4. 4. Make certain the conversion label is applied to the gas control, heating appliance, and any other controls to show conversion to a new type of gas. 3 69-2395EF 01

50033841 LP GAS AND 50033842 NATURAL GAS CONVERSION KITS Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Toronto, Ontario M1V 4Z9 customer.honeywell.com U.S. Registered Trademark 2010 Honeywell International Inc. 69-2395EF 01 M.S. 05-10 Printed in U.S.A.

Nécessaires de conversion au GPL 50033841 et au gaz naturel 50033842 POUR LES RÉGULATEURS À GAZ COMBINÉS À DEUX ÉTAGES VR9205 NOTICE D'INSTALLATION APPLICATION Le nécessaire de conversion 50033841 GPL permet de convertir les régulateurs combinés à deux étages de la gamme VR9205 fonctionnant au gaz naturel en régulateurs fonctionnant au GPL. Le nécessaire de conversion 50033842 permet de convertir les régulateurs combinés à deux étages de la gamme VR9205 fonctionnant au GPL en régulateurs fonctionnant au gaz naturel. Ces nécessaires incluent deux vis de réglage de régulateur de pression, deux ressorts, deux vis d'assemblage de régulateur et un autocollant de conversion. Pour utiliser ce nécessaire, s'assurer que le régulateur à gaz est équipé d'un régulateur de pression à deux étages. REMARQUE : Les vannes à gaz-air, à modulation et à étage unique ne peuvent pas être converties à l'aide de ce nécessaire. AVERTISSEMENT Risque d'incendie ou d'explosion. Peut causer des dégâts et des blessures graves, voire mortelles. Respecter ces avertissements avec précision : 1. Pour éviter une accumulation dangereuse de gaz combustible, couper l'alimentation en gaz au niveau de la vanne de service de l'appareil avant de commencer l'installation et effectuer le test de fuite de gaz une fois l'installation terminée 2. Ne pas forcer sur l'interrupteur du régulateur à gaz. Utiliser uniquement la main pour tourner l'interrupteur du régulateur à gaz. Ne jamais utiliser d'outils. Si l'interrupteur ne peut pas être actionné manuellement, un technicien qualifié doit remplacer le régulateur. Une tentative de réparation ou une utilisation forcée peuvent entraîner un incendie ou une explosion. AVERTISSEMENT Risque de choc électrique ou de dégât matériel. Peut causer des blessures graves, voire mortelles, ou un court-circuit de l'équipement. Débrancher l'alimentation avant l'installation. Toujours modifier l'orifice principal et l'orifice de la veilleuse lors de la conversion de gaz naturel à GPL ou vice-versa. Suivre avec soin les spécifications et les instructions du fabricant de l'appareil pour garantir une conversion adéquate de l'appareil. Les régulateurs à gaz sont réglés en usine pour le gaz naturel (ou fabriqué) ou le GPL. Ne pas tenter d'utiliser un régulateur à gaz réglé pour le gaz naturel (ou fabriqué) sur du GPL ou viceversa. Suivre les instructions du fabricant de l'appareil le cas échéant, ou bien lire ces instructions pour s'en servir de guide. AVERTISSEMENT Risque d'incendie ou d'explosion. Peut causer des dégâts et des blessures graves, voire mortelles. Effectuer le test de fuite de gaz à chaque fois que des travaux sont effectués sur un système à gaz. Installation des nécessaires de conversion du régulateur 1. Couper l'alimentation en gaz au niveau de la vanne de service de l'appareil. 2. Retirer les vis d'assemblage du régulateur et les vis de réglage du régulateur de pression des tours de régulation haute et basse. Voir la Fig. 1. 3. Retirer les ressorts de régulateur existants des tours. 4. Insérer les ressorts de régulateur de rechange sur les deux tours. Voir la Fig. 2. 5. Installer les vis de réglage du régulateur de pression en plastique neuves sur les deux tours. Voir la Fig. 2. 6. Ouvrir de nouveau l'alimentation en gaz vers l'appareil. 7. Effectuer le réglage du régulateur de pression haute avant de régler celui de la pression basse en utilisant un manomètre ou en chronométrant le compteur à gaz. S'assurer que l'appareil est sur 69-2395EF-01

NÉCESSAIRES DE CONVERSION AU GPL 50033841 ET AU GAZ NATUREL 50033842 haute combustion avant de régler le régulateur haute pression. Consulter la section Étalonnage de la sortie plus loin dans ce manuel. 8. Installer les vis d'assemblage du régulateur neuves sur les deux tours. 9. Appliquer l'étiquette de conversion sur le régulateur à gaz. 10. Effectuer un test de fuite de gaz sur le régulateur. Voir la section Test de fuite de gaz suivante. PRISE DE PRESSION DE SORTIE VIS DE RÉGLAGE DU RÉGULATEUR BASSE PRESSION SOUS LE CAPUCHON INTERRUPTEUR MARCHE/ARRÊT MF29751 Fig. 3. Nécessaire de conversion de gaz : sortie. VIS DE RÉGLAGE ORIFICE DE VENTILATION DU RÉGULATEUR HAUTE PRESSION SOUS LE CAPUCHON MF29750 Fig. 1. Régulateur d'installation du nécessaire de conversion. BORNES PRISE DE PRESSION D ENTRÉE MF29752 Fig. 4. Nécessaire de conversion de gaz : entrée. MISE EN SERVICE M29754 Fig. 2. Nécessaire de conversion de gaz. Réglage de l'interrupteur Marche/Arrêt a. ARRÊT : Permet d'arrêter le débit de gaz principal. b. MARCHE : Permet le débit de gaz par le corps du régulateur vers le brûleur principal avec régulation par le système d'allumage. Mise en marche du système Glisser l'interrupteur marche-arrêt sur MARCHE. Allumage du brûleur principal Suivre les instructions du fabricant de l'appareil ou allumer le thermostat pour créer l'appel de chaleur. 69-2395EF 01 2

NÉCESSAIRES DE CONVERSION AU GPL 50033841 ET AU GAZ NATUREL 50033842 Étalonnage de la sortie IMPORTANT 1. Ne pas dépasser la valeur nominale de l'entrée estampillée sur la plaque signalétique de l'appareil ou la pression de l'orifice du brûleur recommandée par le fabricant pour la taille du ou des orifices utilisés. S'assurer que l'alimentation en air principale vers le brûleur principal est bien réglée pour assurer une combustion totale. Suivre les instructions du fabricant de l'appareil. 2. POUR UNE VÉRIFICATION DE L'ENTRÉE DE GAZ EN CHRONOMÉTRANT LE COMPTEUR À GAZ : S'assurer qu'il n'y a pas de débit de gaz par le compteur autre que celui de l'appareil en cours de vérification. Les autres appareils et veilleuses doivent être éteints (ou déduire leur consommation du relevé du compteur). Convertir le débit en Btuh comme décrit dans le formulaire 70-2602, manuel des régulateurs à gaz, et comparer la valeur d'entrée nominale en Btuh à la plaque signalétique de l'appareil. 3. POUR UNE VÉRIFICATION DE L'ENTRÉE DE GAZ AVEC UN MANOMÈTRE : S'assurer que le régulateur à gaz est sur ARRÊT avant de retirer le bouchon de la prise de pression de sortie pour connecter le manomètre (jauge de pression). Remettre également l'interrupteur du régulateur sur ARRÊT lors du retrait de la jauge et de la réinstallation du bouchon. Avant de retirer le bouchon de la prise de pression d'entrée, couper l'alimentation en gaz au niveau de la vanne manuelle dans la tuyauterie de gaz de l'appareil ou du réservoir si du GPL est utilisé. Couper aussi l'alimentation en gaz avant de débrancher le manomètre et de réinstaller le bouchon. Recommencer le test de fuite de gaz au niveau du bouchon avec le brûleur principal en fonctionnement. REMARQUE : Vérifier la pression d'entrée avant de régler le régulateur de pression. Le modèle à deux étages VR9205 nécessite que les réglages haute pression et basse pression du régulateur soient vérifiés et ajustés. Les séquences de fonctionnement des appareils à deux étages varient. Consulter les instructions du fabricant de l'appareil pour la séquence de fonctionnement spécifique et la procédure de réglage du régulateur relatives à l'appareil dans lequel le régulateur est installé. 1. Consulter les instructions du fabricant de l'appareil pour obtenir les réglages de pression du régulateur à basse combustion et à haute combustion. 2. Installer les ressorts et les vis de réglage du régulateur conformément aux instructions de conversion ci-dessus. 3. Régler l'appareil sur combustion élevée. 4. Lorsque le brûleur principal fonctionne sur combustion élevée, effectuer l'étalonnage du régulateur en chronométrant le compteur à gaz ou en utilisant un manomètre connecté à la prise de pression du sortie du régulateur. Voir la Fig. 3. a. Régler le régulateur haute pression en fonction de la pression nominale de l'appareil. b. Voir le Tableau 1 pour la plage de réglage de la vanne à gaz. Les spécifications de l'appareil doivent se trouver dans cette plage. c. Avec un tournevis, tourner la vis de réglage Haut (Hi) dans le sens des aiguilles d'une montre pour augmenter la pression de gaz vers le brûleur ou dans le sens contraire pour la réduire. 5. Après l'étalonnage haute pression, étalonner le régulateur basse pression en utilisant la même méthode de mesure. Les séquences de fonctionnement des appareils à deux étages varient. Consulter les instructions du fabricant de l'appareil pour la séquence de fonctionnement spécifique relative à l'appareil dans lequel le régulateur est installé, ainsi que pour les instructions permettant d'éviter que le régulateur ne passe à l'étage supérieur lors de la vérification du réglage basse pression du régulateur. 6. Lorsque le brûleur principal fonctionne sur combustion basse, effectuer l'étalonnage du régulateur en chronométrant le compteur à gaz ou en connectant un manomètre à la prise de pression du sortie du régulateur. Voir la Fig. 3. a. Régler le régulateur basse pression en fonction de la pression nominale de l'appareil. b. Voir le Tableau 1 pour la plage de réglage de la vanne à gaz. Les spécifications de l'appareil doivent se trouver dans cette plage. c. Avec un tournevis, tourner la vis de réglage interne de pression basse (LO) dans le sens des aiguilles d'une montre pour l'augmenter ou dans le sens contraire des aiguilles d'une montre pour réduire la pression de gaz au brûleur. 7. Une fois les réglages haute et basse pression étalonnés et vérifiés, installer les capuchons de réglage neufs. 8. Si la pression de sortie ou le débit désirés ne peuvent pas être obtenus en réglant le régulateur à gaz, vérifier la pression d'entrée du régulateur à l'aide d'un manomètre au niveau de la prise de pression d'entrée sur le régulateur à gaz. Voir la Fig. 4. Si la pression d'entrée est dans la plage nominale (voir le Tableau 1), replacer le régulateur à gaz. Autrement, effectuer les étapes nécessaires pour assurer une pression adéquate. 9. Replacer les bouchons des prises de pression. 10. Appliquer l'étiquette de conversion sur le régulateur à gaz. 11. Effectuer un test de fuite sur le régulateur. Voir la section Test de fuite de gaz suivante. Tableau 1. Spécifications des pressions du régulateur de pression (po c.e.). Modèle Deux étages Type de gaz Plage de pression d'entrée nominale Pression de sortie nominale réglée en usine NAT. 5,0-7,0 1,7 Basse 3,5 Haute GPL 12,0-14,0 4,9 Basse 10,0 Haute Plage de réglage 0,6-3,0 Basse 3,0-5,0 Haute 2,5-7,0 Basse 8,0-11,0 Haute 3 69-2395EF 01

NÉCESSAIRES DE CONVERSION AU GPL 50033841 ET AU GAZ NATUREL 50033842 Test de fuite de gaz AVERTISSEMENT Risque d'incendie ou d'explosion. Peut causer des dégâts et des blessures graves, voire mortelles. Effectuer le test de fuite de gaz à chaque fois que des travaux sont effectués sur un système à gaz. IMPORTANT Ne pas pulvériser de solution savonneuse sur le régulateur à gaz. Ne pas utiliser une quantité excessive de solution savonneuse pour effectuer le test de fuite de gaz. Ceci pourrait endommager le régulateur. Test de fuite de gaz 1. Badigeonner les raccords de tuyauterie en amont du régulateur à gaz avec une solution savonneuse épaisse. Les bulles indiquent une fuite de gaz. 2. Si une fuite est détectée, serrer les raccords de tuyauterie. 3. Allumer le brûleur principal. S'éloigner du brûleur principal lors de l'allumage pour éviter les blessures causées par des fuites cachées qui pourraient causer un retour de flamme dans le vestibule de l'appareil. 4. Avec le brûleur principal allumé, badigeonner les joints du tuyau (y compris les douilles) et l'entrée et la sortie du régulateur avec une solution savonneuse épaisse. 5. Si une autre fuite est détectée, éteindre le régulateur à gaz et serrer les joints et les raccords du tuyau. 6. Remplacer la pièce si la fuite ne peut pas être réparée. VÉRIFICATION 1. S'assurer que l'alimentation en air principale vers le brûleur principal est bien réglée pour assurer une combustion complète au réglage de pression final. Le brûleur principal doit s'allumer fiablement dans toutes les conditions. 2. Activer le système et observer au moins un cycle complet pour s'assurer que tous les régulateurs fonctionnent correctement. a. Vérifier avec soin l'allumage du brûleur principal. S'assurer que le brûleur principal s'allume en douceur et que tous les orifices restent allumés. b. Vérifier la pression du collecteur plein débit (haute pression) indiquée sur la plaque signalétique de l'appareil pour la haute pression. La pression de sortie plein débit du régulateur à gaz doit correspondre à cette valeur. c. Vérifier la pression du collecteur bas débit (basse pression) indiquée sur la plaque signalétique de l'appareil pour la pression basse. La pression de sortie bas débit du régulateur à gaz doit correspondre à cette valeur. 3. Si un manomètre (jauge de pression) est utilisé, réinstaller les bouchons de prises de pression et effectuer le test de fuite de gaz au niveau des bouchons des prises de pression d'entrée et de sortie. Voir les Fig. 3 et 4. 4. S'assurer que l'étiquette de conversion est appliquée sur le régulateur à gaz, l'appareil de chauffage et tout autre dispositif pour indiquer la conversion au nouveau type de gaz. Solutions de régulation et d automatisation Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35, Dynamic Drive Toronto (Ontario) M1V 4Z9 customer.honeywell.com Marque de commerce déposée aux É.U. 2010 Honeywell International Inc. Tous droits réservés 69-2395EF 01 M.S. 05-10 Imprimé aux États-Unis