Bennett Pump Company



Documents pareils
Lavatory Faucet. Instruction Manual. Questions?

Fabricant. 2 terminals

NEW Fin Fan / Air cooled condenser cleaning

Folio Case User s Guide

Contrôle d'accès Access control. Notice technique / Technical Manual

Instructions Mozilla Thunderbird Page 1

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Paxton. ins Net2 desktop reader USB

Z-Axis Compliance Device Compliance en z

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Package Contents. System Requirements. Before You Begin

GASKET FOR TONER COLLECTION BOTTLE

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

DOCUMENTATION - FRANCAIS... 2

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Guide d'installation rapide TFM-560X YO.13

Notice Technique / Technical Manual

Stérilisation / Sterilization

Warning: Failure to follow these warnings could result in property damage, or personal injury.

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Garage Door Monitor Model 829LM

Embases pour raccordement G1/8 - G1/4

DOCUMENTATION - FRANCAIS... 2

Le No.1 de l économie d énergie pour patinoires.

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

POLICY: FREE MILK PROGRAM CODE: CS-4

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

SYSTÈME JETS D AIR WISH WISH AIR JETS SYSTEM Système de massage à jets d air pour bains en polymère - Air jet massage system for polymer bathtubs

APPENDIX 6 BONUS RING FORMAT

Vannes à boisseau sphérique Ball valves

Guide d installation Deco Drain inc. DD200

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Laboratory accredited by the French Home Office (official gazette date February 5 th, 1959, modified) Valid five years from August 27 th, 2013

How to Login to Career Page

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

R.V. Table Mounting Instructions

Nouveautés printemps 2013

Plans API pour Garnitures Mécaniques

WEB page builder and server for SCADA applications usable from a WEB navigator

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Flottes privatives Une gestion maîtrisée Fleet management The management expert

Maximum Capacity / Capacité maximal: 10 kg/min

Improving the breakdown of the Central Credit Register data by category of enterprises

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

CLASSIFICATION REPORT OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2007

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

BILL 203 PROJET DE LOI 203

Practice Direction. Class Proceedings

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

Exercices sur SQL server 2000

F1 Security Requirement Check List (SRCL)

I-751-FRC. FireLock Clapet Anti-Retour d Alarme AVERTISSEMENT MANUEL D INSTALLATION, DE MAINTENANCE, ET D ESSAIS SÉRIE

Credit Note and Debit Note Information (GST/ HST) Regulations

ADHEFILM : tronçonnage. ADHEFILM : cutting off. ADHECAL : fabrication. ADHECAL : manufacturing.

Quick Installation Guide TEW-AO12O

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Gestion des prestations Volontaire

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

PARIS ROISSY CHARLES DE GAULLE

Table des matières QUINCAILLERIE FONCTIONNEL FUNCTIONAL HARDWARE. Clé H1 Serrure et pêne H2. Serrure à levier H4

Propriétés de la matière. Material properties. Sonde de pression Pressure probe. Ref : Français p 1. English p 3.

INDIVIDUALS AND LEGAL ENTITIES: If the dividends have not been paid yet, you may be eligible for the simplified procedure.

72" STORAGE SHELF OR WORKBENCH ÉTAGERÈ DE RANGEMENT OU ETABLI DE 72 PO

Principe de TrueCrypt. Créer un volume pour TrueCrypt

Once the installation is complete, you can delete the temporary Zip files..

Archived Content. Contenu archivé

Tri RUMBA. Twin RUMBA

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

RAPID Prenez le contrôle sur vos données

Interest Rate for Customs Purposes Regulations. Règlement sur le taux d intérêt aux fins des douanes CONSOLIDATION CODIFICATION

Critères à l attention des fabricants et des fournisseurs de biens ou de services : dispositifs mécaniques pour bingo

Contrôle d accès Access control MOD-TCPIP-AI. Notice technique / Technical Manual

CLASSIFICATION REPORT OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2007

Exemple PLS avec SAS

Stainless Steel Solar Wall Light


SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

Spécial Catégorie 6 Patch Cords

Institut français des sciences et technologies des transports, de l aménagement

An Act to Amend the Tobacco Sales Act. Loi modifiant la Loi sur les ventes de tabac CHAPTER 46 CHAPITRE 46

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

ETABLISSEMENT D ENSEIGNEMENT OU ORGANISME DE FORMATION / UNIVERSITY OR COLLEGE:

PIB : Définition : mesure de l activité économique réalisée à l échelle d une nation sur une période donnée.

de stabilisation financière

Université de XY University of XY. Faculté XY Faculty of XY

Revision of hen1317-5: Technical improvements

Application Form/ Formulaire de demande

Le passé composé. C'est le passé! Tout ça c'est du passé! That's the past! All that's in the past!

Logitech Speaker System Z553 Setup Guide Guide d installation

PRACTICE DIRECTION ON THE LENGTH OF BRIEFS AND MOTIONS ON APPEAL

Curve. Innover pour simplifier! Mistral signe les fontaines High Tech à hauteur adaptable. Mistral signs the High Tech coolers with adaptable height

Free filter reminders! Sign up online at: santevia.com/filterease. need help? Contact Santevia!

Editing and managing Systems engineering processes at Snecma

Frequently Asked Questions

Transcription:

Bennett Pump Company T-75 Hydraulic Pumping Units Operation, Service & Parts Manual Only Trained Personnel May Work on This Equipment For more information, please contact: Jim Biesecker, Component Sales 1218 E. Pontaluna Road Spring Lake, Michigan USA Tel: 800-235-7618 (USA) Tel: 231-798-1310 (International) Tel: 800-423-6638 (Tech Support - USA) Tel: 231-799-6262 (Sales) Fax: 231-799-6200 Email: techhelp@bennettpump.com Email: sales@bennettpump.com Email: jbiesecker@bennettpump.com Read this Book For new books, visit out web page at: www.bennettpump.com For Part Pricing, please visit the parts pricing section under the Literature Tab on our website. 107072 Rev D 02/21/11 Bennett 1218 E. Pontaluna Road, Spring Lake, MI 49456 USA 800-235-7618 ~ Outside USA 231-798-1310 sales@bennettpump.com ~ www.bennettpump.com

2 107072 Rev D 02/21/11

Table of Contents Introduction 4 Specification Sheet 5 Technical Specifications 6 Pump Curve U.S. Market 7 Pump Curve European Market 8 Overall Dimensions 9 Theory of Operations 11 Hydraulic Schematics & Principle 13 How to Correct Problems on Pumping Units 15 Parts List 18 Appendices A. European Approval 22 B. European Approval 25 C. Dimensions and Mounting 29 D. Installation Piping for Type 75 Pump Dispenser 31 3 107072 Rev D 02/21/11

Introduction The Type 75 pumping unit is the standard product produced by Bennett Pump Company. It is used in many countries and has proven its ability to work properly even in the toughest conditions. It is a compact, lightweight unit built with the following functions: Filtering Pumping Air elimination By-Pass (adjustable as an option) Outlet Control Valve The same unit is used to achieve the two standard flows of 13 gpm (3m 3 /h) or 22 gpm (5m 3 /h). This feature is achieved by: U.S. Market 60Hz power: Using two sizes of pump chamber initially assembled into the housing. The 13 gpm pump requires a 250 Watt 1/3 hp motor, the 22 gpm pump uses a 560 Watt 3/4 hp motor. Europeon Market 50Hz power: Running the 22 gpm pump at different speeds, just by changing the pump pulley This unit uses a rotary vane pump with carbon blades that produces very good suction (power) even when the pump is dry (at start). The rotor is supported at each end by self lubricated insert bearings that are field replaceable. Air elimination is achieved within extreme standards through a patented fully static device using a vortex effect. Filtration is achieved with three different filter means (10 micron cloth filter, 35 micron pleated paper filter and 70 micron Nylon strainer), according to the conditions of use. The T-75 Pumping Unit is fully compatible with the SB-100 Meter. For further information, please contact the Bennett Technical Service Department at 1-800-423-6638. 4 107072 Rev D 02/21/11

Specification Sheet Standard Fuels (up to 15% alcohol) or Alcohol Fuels (E85 typical) Standard Flow (13 GPM) or High Flow (22 GPM) Ultra High (50 psi), High Pressure (45 psi), Normal Pressure (35 psi) or Low Pressure (25 psi) By-Pass Valve Spring (nominal pressures w/adjustable bypass screwed in) Adjustable or Non-Adjustable By-Pass Valve Settings Low Pressure (4.3 psi) or Standard Pressure (6 psi) Control Valve Spring Meter Outlet Flange or Tube Style Outlet W/Tube outlet - offer a Motor Mount Option on Atmospheric Cover 100 or 70 Micron Metal Strainer Basket or 35 Micron Paper Element Filter with or without Fabric Integral Inlet check valve 5 107072 Rev D 02/21/11

Technical Specifications U.S. Market Maximum Flow (gpm) 13 22 Noise Level (db) 68 72 Bypass Pressure (psi) 25 25 Motor Power (hp) 1/3 3/4 Minimum Dry Suction (in. Hg) 10 12 Minimum Wet Suction (in. Hg) 21 21 Air Elimination According to OIML, CEE 77.313 Regulation Micron Filter (µ) 10,35,70 according to conditions of use Pump Curve See Figure 1 See Figure 2 Technical Specifications European Market Maximum Flow (m 3 /h) 3 5 Minimum Flow (m 3 /h) 0.3 0.5 Noise Level (db) 68 72 Bypass Pressure (b) 1.8 (Adjustable 1.2-2.5) 2.0 (Adjustable 1.2-2.5) Motor Power (Kw).37.55 Minimum Dry Suction (mb Hg) 450 Minimum Wet Suction (mb Hg) 700 Air Elimination According to OIML, CEE 77.313 Regulation Micron Filter (µ) 10,35,70 according to conditions of use Pump Curve See Figure 3 Approval Documents (See Appendices Ministère de I Industrie et du Commerce - FRANCE #85.0.01.462.2.3 (July 1, 1985) #87.0.04.462.2.3 (Dec. 31, 1987) 6 107072 Rev D 02/21/11

Pump Curves U.S. Market 30 25 Pump Speed 700 rpm Pump Pressure (psi) 20 15 10 5 Test Conditions: 1. Tested on Stoddard Solvent * 30 SSU Viscosity * 0.78 Specific Gravity 2. 12 inches Hg operating vacuum 3. Fixed bypass cover 0 0 2 4 6 8 10 12 14 16 Flow Rate (gpm) T-75 Pump (1/3 hp) Performance U.S. Market Figure 1 35 30 Pump Speed 700 rpm 25 Pump Pressure (psi) 20 15 10 Test Conditions: 1. Tested on Stoddard Solvent * 30 SSU Viscosity * 0.78 Specific Gravity 2. 12 inches Hg operating vacuum 3. Fixed bypass cover 5 0 0 5 10 15 20 25 Flow Rate (gpm) T-75 Pump (3/4 hp) Performance U.S. Market Figure 2 7 107072 Rev D 02/21/11

Pump Curves European Market 2.5 2 Note: Adjustable bypass can vary pump pressures from posted curve values by +/- 20 % from 0 to 80% of fast flow Pump Speed 700 rpm 0.55 Kw motor Pump Pressure (bars) 1.5 1 0.5 Test Conditions: 1. Tested on Stoddard Solvent * 30 SSU Viscosity * 0.78 Specific Gravity 2. 400 mb Hg operating vacuum Pump Speed 450 rpm 0.37 Kw motor 0 0 10 20 30 40 50 60 70 80 90 Flow Rate (lpm) T-75 Pump Performance European Market Page 15 Figure 3 8 107072 Rev D 02/21/11

Overall Dimensions T75 with Meter Outlet Top View 2.69 Back View Side View Front View 0: 1.63 0:[40mm] Bottom View 9 107072 Rev D 02/21/11

Overall Dimensions T75 with Tube Outlet Top View 2.69 Back View Side View Front View 0: 1.63 0:[40mm] Bottom View 10 107072 Rev D 02/21/11

Theory of Operation Detailed Description Figure 7 11 107072 Rev D 02/21/11

Theory of Operation The pump assembly has the following main components: (See Figure 7 for numbers in parenthesis.) a body (1) of cast aluminum The inlet is designed to accept a triangular inlet flange with a 3-hole bolt pattern. a cover (2) outlet flanged for direct meter mounting tubular outlet for remote meter mounting (as shown on page 6) a filter (3) in the horizontal position. The filter cover includes a pipe plug to drain the pump. An optional inlet checkvalve (19) is available to hold product in the suction line when the pump is turned off. This is an environmentally friendly device that maintains a vacuum in the line preventing fuel from leaking through a loose joint into the ground. a rotating pump (4) with radial carbon blades Throwout rings (5) maintain contact of the blades to the stator. The stator (6) is made of cast iron and is tightly fitted in the pump body. The rotor (7) is made of cast iron with a chrome plated shaft. Self lubricated bearings (21) prevent seizure when tank is pumped dry. The cover (8), also of cast iron, encapsulates the rotor and the stator. an air elimination assembly (9), a patented fully static device, uses a vortex effect. The insert (10) starts spinning the fluid. The foam and the air pass through the tube (11) and evacuated through the orifice (12). a drain line eliminator (13) or atmospheric chamber of 1.2 gallon (4.5 liter) capacity. The float valve assembly (14) provides for the recovery of liquid from the chamber, while air is evacuated through the vent tube (15). A non return float (20) seals the atmospheric chamber when the pump is turned off to prevent flooding and spilling out onto the driveway. a bypass valve (16) limiting the maximum working pressure. its cover includes a device to adjust the bypass pressure (optional in USA) a control valve assembly (17) assures that all downstream hydraulic components are filled with liquid. This valve has a relief valve (18) to relieve excess pressure. NOTE: A diaphragm operated preset valve is available as an option. 12 107072 Rev D 02/21/11

Hydraulic Schematics & Principle Figure 8 Figure 9 13 107072 Rev D 02/21/11

(See Figure 8 for numbers in parenthesis.) Hydraulic Schematics & Principle The product is drawn from the underground storage tank through the strainer screen of filter (1). The rotary van pumping unit (2) pressurizes the fluid. Product enters the centrifugal air separator assembly (3). Any air present is forced out the air tube along with a small amount of liquid into the atmospheric chamber (4). Product collected in the atmospheric chamber is returned to the pump intake across the non return float when the liquid level in the chamber lifts the float and valve assembly from its seat (5). Any air is then vented to the atmosphere through the vent tube. Air free product leaving the air separator opens the control valve (6) and is pumped to the meter. The control valve includes a built-in relief valve (7) which relieves excess pressure caused by hot weather expansion. Product passes through the meter where it is accurately measured, then through the hose and nozzle into the vehicle being fueled. Whenever the nozzle is not fully opened, some liquid is relieved into the pump intake through the bypass valve (8). 14 107072 Rev D 02/21/11

How to Correct Problems on Pumping Units Problem Cause Action 1. The motor starts but the pump does not deliver fuel. a. The fuel supply is below the suction stub in the storage tank. b. The vent pipe is plugged in the storage tank. c. The strainer screen or filter assembly has an obstruction. d. The bypass valve is not seating properly due to wear or obstruction. a. Fill the storage tank. b. Clean the vent pipe. c. Remove obstructions from the screen or filter assembly. d. Check the valve for an obstruction causing the valve to stay open, and/or replace the bypass valve. e. The v-belt is loose or broken. e. Adjust or replace the v-belt. f. There is an obstruction in the atmospheric float valve. g. The pump is out of prime. All fuel drained out of suction line due o fault line check or foot valve. f. Clean the float and valve area. Check for swelling and binding in the linkage. g. Check for a faulty foot valve in the storage tank or a faulty check valve in the suction line. h. The suction line is leaking. h. Start the pump and open the nozzle. If bursts of air are felt while holding a finger on the vent tube, the suction line is damaged. Repair or replace. i. The intake line, foot valve, angle check valve, or vertical check valve have an obstruction. j. The suction stub in the storage tank is on the bottom of the tank. k. The control valve has an obstruction. i. Connect a vacuum gauge to the 1/4 plug on the filter cover. Turn the pump on and open the nozzle. A reading of 15 or more inches of mercury with no flow indicates a complete blockage in the suction line. Clean the line or replace. j. Make sure there is a three inch clearance. k. Clean the control valve. It must slide freely in the valve cavity. l. The nozzle is not working. l. Replace the nozzle. m. *Two pumps are connected to one storage tank with one suction line. There is a faulty check valve in one of the supply lines. *Not recommended. m. Disconnect the vent tube on the idle pump. Install a short copper tube. Place the end of the copper tube in a container of liquid. If the liquid is drawn out of the container when the opposite pump is operated with an open nozzle, the line check valve is faulty. Replace the check valve. 15 107072 Rev D 02/21/11

How to Correct Problems on Pumping Units Problem Cause Action 2. The pump runs, but delivery is slow. a. The fuel supply level is low. a. Fill the storage tank. b. The storage tank vent pipe is b. Clean the vent pipe. partially obstructed. c. The strainer screen is partially plugged. d. The pump bypass valve is not seated properly. c. Remove obstructions from the screen or filter assembly. d. Remove and clean the strainer screen. e. The v-belt is loose. e. Adjust the v-belt. f. The motor voltage is too low. f. Check the power supply voltage. Check for too many pieces of equipment on one electrical line. g. A blade or blades in the pump are worn or broken. h. An automatic nozzle has been installed. g. Check the blades and replace if necessary. h. Delivery speed will be reduced by 10-25%. If maximum speed is desired, replace with a manual nozzle. i. The motor is defective. i. Inspect the motor for loose connections. If no loose connections are found, the motor is defective. Repair or replace. j. There is a slow leak in the suction line. k. The suction line is obstructed or the foot valve, angle or vertical check valve is partially stuck and will not open fully. l. The pump control valve is partially stuck and will not open fully. m. The nozzle check valve is sticking. n. The hose is defective (flattened). j. Start the pump and open the nozzle. If bursts of air are felt while holding a finger on the vent tube, the suction line is damaged. Repair or replace. k. Connect a vacuum gauge to the 1/4 plug on the filter cover. Turn the pump on and open the nozzle. A reading of 11 to 13 inches of mercury indicates a partial obstruction in the suction line. Clean or replace the suction line components. l. Remove the valve and clean thoroughly. m. Clean or replace the nozzle check valve. n. Replace the hose. 16 107072 Rev D 02/21/11

Problem Cause Action 3. Inaccurate Delivery. a. Control valve stuck open. a. Remove 4-bolt control valve cover and free control valve. b. Vent tube from air eliminator to atmosphere plugged. b. Clear any obstructions. 4. Fuel Runs out Vent Tube When Pump is Operating. How to Correct Problems on Pumping Units 5. The computer jumps when the pump is turned on. a. Float valve stuck in a closed position. b. Flooded suction chamber. Directional flow valve missing. a. Control valve not seated properly. b. Expansion relief Dill valve in control valve stuck open. a. Clean the float and valve area. Check for swelling and binding in the linkage. b. Storage tank level must be lower than pumping unit. Make sure 2 or more pumps are not using same suction line. a. Remove valve cover & inspect for dirt or nicks in O- ring. b. Remove and inspect for foreign matter. Pull spring loaded seat for better view. Reinstall. 17 107072 Rev D 02/21/11

Parts List 18 107072 Rev D 02/21/11

Type 75 Pumping Unit 19 107072 Rev D 02/21/11

Type 75 Pumping Unit Parts List Item Part Number Description Comment 1 A479902 Bolt M8-1.25 X 25 mm (Use N840502 for Seal Wire Bolt) 2 N152902 Meter Inlet Adaptor With Tap 105588 Meter Inlet Adaptor High Alcohol 3 N162801 Gasket, Meter Inlet Adaptor 4 111874 Housing, Air Valve Float Assembly 5 108737 Gasket 9 108734 Float 10 111537 Retainer Ring 11 110211 ID Tag 12 N152801 Cover, Atmospheric Chamber Meter Mount Style 105787 Cover, Atmospheric Chamber Meter Mount Style - High Alcohol 13 N347901 Cover, Atmospheric Chamber Pipe Outlet with Motor Mount Ears 103055 Cover, Atmospheric Chamber Pipe Outlet with Motor Mount Ears - High Alcohol 108945 Cover, Atmospheric Chamber GPU 109582 Cover, Atmospheric Chamber GPU - High Alcohol 17 N162901 Gasket - Atmospheric Cover 18 A480101 Bolt - Round Head M6-0.7 X 20 mm 19 N888301 Non-Reversing Float 20 111788 O-Ring #O17 Also used with High Alcohol 21 109892 Atmospheric Float Assembly 22 N162901 Gasket - Atmospheric Cover 23 113078 One Piece Air Separator Body 113079 One Piece Air Separator Body High Alcohol 24 N162501 Gasket, Inlet Separator 25 N162601 Gasket, Outlet Separator 26 N190201 Insert - Air Separator Inlet 27 108727 Tube - Air Separator 28 108730 Piston OIML Only 29 108725 Spring 30 108728 End Cap 31 N225301 Tube - Air Separator 32 109668 Screw - Air Test Valve 33 109666 Adaptor - Air Test Valve 34 110430 Pipe Plug 1/4-18NPT 35 N154801 Cover, Control Valve 103053 Cover, Control Valve High Alcohol 36 N162301 Gasket 37 E008001 Spring Standard Delivery Pump 12 GPM J325201 Spring Heavy Duty Delivery Pump 22 GPM 38 113022 Control Valve Assembly Aluminum Body Version with Hard Coat 39 A321901 Pressure Relief Valve 40 111790 O-Ring #210 Also used with High Alcohol 41 N150602 Pump Body 103052 Pump Body High Alcohol N150603 Pump Body Side Inlet Version 109735 Pump Body Side Inlet High Alcohol 42 N160301 Filter Insert 43 100070 Strainer Standard Production A311901 Filter Paper Filter 35 Micron Strainer Special - Used with Sack N347301 Cloth Sack 10 Micron 20 107072 Rev D 02/21/11

Type 75 Pumping Unit Parts List Item Part Number Description Comment 44 N905001 Filter Spring 45 N162201 Gasket 46 N154701 Filter Cover 103054 Filter Cover High Alcohol 47 N154901 Bypass Cover Non-Adjustable 105585 Bypass Cover High Alcohol 48 N162401 Gasket 49 N481201 Bypass Valve Standard - Silver Spring Low Pressure N481202 Bypass Valve Standard - Green Spring Medium Pressure N481203 Bypass Valve Standard - Copper Spring High Pressure 50 111791 O-Ring #229 Also used with High Alcohol 51 A620801 Cap Nut 52 A620901 Seal Ring 53 N873001 Disc 54 N872801 Adaptor Not Sold Separately - See Item #60 55 A620101 Retaining Ring 56 N872901 Check Valve Body 57 N873201 Spring 58 N873101 Washer 59 N872701 Shaft 60 N873301 Check Valve Assembly With out Ring KR044102 Check Valve Assembly Includes Item #50 & Item #60 61 N308301 Cap 62 N308201 Adjustment Screw 63 A507901 Washer 64 N308101 Cover - Adjustable Bypass 65 A479903 Screw M8-1.25 X 20 mm 66 A000301 Lock Washer 67 A028101 Flat Washer 68 N106901 Pulley - Single Groove 100040 Pulley - Dual Groove 69 N155901 Clamping Ring 70 N162701 Gasket 71 J682702 Rotor Cover Assembly 72 A480001 Flat Head Screw 73 H352101 Shaft Seal Retainer 74 A323702 Shaft Seal (with insertion tool) 109711 Shaft Seal Kit - Includes #74 & 75 with install plug 75 A247014 Square Seal 76 N103801 Rotor Cover 77 N650401 Throw Out Ring Standard Delivery Pump N238101 Throw Out Ring Heavy Duty Pump 78 A199501 Woodruff Key 79 A263101 Retaining Ring 80 N238301 Rotor & Shaft Assembly Standard 6 Blade Rotor *KR0420xx *Rotor Replacement Kit Includes #70, 74, 75, (2) 77, 80, (6) 81 xx= 01 Std Delivery 02 Heavy Duty 81 110704 Rotor Blade 82 N156401 Stator Standard Delivery Pump N159501 Stator Heavy Duty Pump KR036604 Gasket Set for Pumping Unit Complete Set of Gaskets, Seals, and O-Rings for P/U 21 107072 Rev D 02/21/11

Appendix A BULLETIN OFFICIEL DES INSTRUMENTS DE MESURE CERTIFICAT D'APPROBATION C.E.E. DE MODELES n 87.0.04.462.2.3 du 31 décembre 1987 modifiant le certificat C.E.E. n 85.0.01.462.2.3 du fer juillet 1985 (f) Groupes de pompage el de dégazage SATAM modèles EPZ 75/3 et EPZ 75/5 Le présent certificat est établi en application de la directive 71/316/CEE du 26 juillet 1971, modifiée par la directive 83/575/CEE du 26 octobre 1983, relative aux dispositions communes aux instruments de mesurage et aux méthodes de contrôle métrologique, de la directive 71/319/CEE du 5 juillet 1971, relative aux coupleurs de liquides autres que l eau el de la directive 77/313/CEE du 5 avril 1977, modifiée par la directive 82/625/CEE du l'er juillet 1982, relative aux ensembles de mesurage de liquides autres que l eau. Du décret n 73-788 du 4 août 1973, modifié par le décret n 84-1107 du 6 décembre 1984, portant application des prescriptions de la Communauté économique européenne relatives aux dispositions communes aux instruments de mesurage et aux méthodes de contrôle métrologique et du décret n 73-791 du 4 août 1973 relatif a l'application des prescriptions de la Communauté économique européenne au contrôle des compteurs volumétriques de liquides autres que l eau et de leurs dispositifs complémentaires. Fabricant: SATAM Industries, 63, Avenue du General. Leclerc, B.P. 100. 93123 La Courneuve. Paris, France. Objet: Le présent certificat CEE modifie le certificat CEE n 85.1.01.462.2.3 du l'er juillet 1985 (1). Caractéristiques: Les groupes de pompage et de dégazage SATAM, modèles EPZ 75/3 et EPZ 75/5, faisant l objet du présent certificat CEE différent des modèles approuvés par le certificat CEE précité par: Le remplacement sure le couvercle des groupes de pompage et de dégazage d un clapet tare par un orifice protège par une bride rivetée : cet orifice assure l'évacuation des vapeurs et des gaz de la cuve de purge dans le cas ou le tube de mise a l'atmosphère est obstrue. La modification du groupe de pompage du modèle EPZ 75/3 : il est identique a celui du modèle EPZ 75/5 mais la vitesse de rotation de l axe des palettes dans la chambre d aspiration est réduite. La pression maximale de fonctionnement, identique pour les deux modèles, est égale à 2 bar. Les autres caractéristiques, les indications complémentaires, le signe d approbation CEE, le principe de fonctionnement et le plan de scellement ne sont pas modifies. Les ensembles de mesurage routiers approuves antérieurement avec un groupe de pompage et de dégazage SATAM, modèle EPZ 75/3 ou EPZ 75/5, objet du certificat CEE n 85.1.01.462.2.3 précité peuvent être équipes d un groupe de pompage et de dégazage objet du présent certificat. (1) Revue de Métrologie, juillet 1985, page 509. Revue de Métrologie, t. 65, n 12, décembre 1987 1403 22 107072 Rev D 02/21/11

Appendix A Signe d approbation de modèle: F85 Dépôt de modèles: 01.462 BULLETIN OFFICIEL DES INSTRUMENTS DE MESURE Les plans et schémas ont été déposés au siège de la direction régionale de l industrie et de la recherche d Ile-de-France et à la sous direction de la métrologie. Validité du présent certificat CEE: Le présent certificat CEE est valable jusqu en juillet 1995. Annexe: Dessin n 4858. Pour le ministre et par délégation: Par empêchement du directeur général de l industrie: L Ingénieur général des Mines, A.C. Lacoste. 1404 Revue de Métrologie, t. 65, n 12, décembre 1987 23 107072 Rev D 02/21/11

Appendix A BULLETIN OFFICIEL DES INSTRUMENTS DE MESURE Groupes de pompage et de dégazage SATAM EPZ 75/3 et EPZ 75/5 Vue en coupe du couvercle N 4858 tube do mise a l atmosphère rivets bride couvercle sortie vers le mesureur orifice cuve de purge Revue de Métrologie, t. 65, n 12, décembre 1987 1405 24 107072 Rev D 02/21/11

Appendix B BULLETIN DES INSTRUMENTS DE MESURE JUILLET 1985 CERTIFICAT D'APPROBATION C.E.E. DE MODELES n 85.0.01.462.2.3 du fer juillet 1985 Groupes de pompage el de dégazage SATAM modèles EPZ 75/3 et EPZ 75/5 (Précision commerciale) Le présent certificat est établi en application de la directive 71/316/CEE du 26 juillet 1971, relative aux dispositions communes aux instruments de mesurage et aux méthodes de contrôle métrologique, de la directive 71/319/CEE du 26 juillet 1971, relative aux coupleurs de liquides autres que l eau Du décret n 73-788 du 4 août 1973 portant application des prescriptions de la CEE relatives aux dispositions communes aux instruments de mesurage et aux méthodes de contrôle métrologique du décret n 73-791 du 4 août 1973 relatif à l'application des prescriptions de la CEE au contrôle des compteurs volumétriques de liquides autres que l eau et de leurs dispositifs complémentaires et de l arrêté du8 novembre 1973 relatif aux modales d application de certaines dispositions du décret n 73-788 du 4 août 1973, de l arrêté du 20 novembre 1973 portant application du décret n 73-791 di 4 aout 1973 et de l arrêté du 19 juin 1978 relatif à l'application des prescriptions de la CEE au contrôle des ensembles de mesurage à computeur columetrique destines à determines le volume des liquides outres que l eau. Fabricant: SATAM Industries, 63, Avenue du General. Leclerc, B.P. 100. 93123 La Courneuve. Paris, France. Caractéristiques: Les groupes de pompage et de dégazage SATAM, modèles EPZ 75/3 et EPZ 75/5, sont destines au mesurage de l essence, do supercarburant et du gazole. Ils sont composes des éléments suivants: Un filtre avec couvercle amovible. Une pompe rotative a six palettes radiales. Un séparateur de gaz statique a effet VORTEX. Une cuve de purge. Un clapet de bipasse. Un clapet anti-retour. Un orifice de refoulement vers le mesureur. Ces deux modèles différent par la cylindrée do la chambre d aspiration de la pompe. En outre, le modèle EPZ 75/7 comporte une bague de guidage des palettes. 25 107072 Rev D 02/21/11

Appendix B BULLETIN DES INSTRUMENTS DE MESURE JUILLET 1985 Leurs caractéristiques métrologiques sont les suivantes: Modèle EPZ 75/3 EPZ 75/5 Débit maximal 3 m 3 /h 5 m 3 /h Pression maximale de fonctionnement 1.7 bar 2 bar Pression minimale de fonctionnement 0.6 bar 0.6 bar Indication complémentaire: Lorsque le groupe de pompage et de dégazage SATAM, modèle EPZ 75/5 est incorporé dans un ensemble de mesurage routier destiné au mesurage de gazole, un indicateur de gaz doit être dispose en amont du flexible de l ensemble. Signe d approbation de modèle: F85 Dépôt de modèles: 01.462 Les plans et schémas ont été déposés au service de la métrologie. Validité du présent certificat CEE: Jusqu au ler juillet 1995. Annexe: Notice descriptive. Dessins n 4490-1 et 2 Pour le ministre et par délégation: Par empêchement du Directeur de la qualité et de la sécurité industrielles: Le Chef du service de la Métrologie, P, Bertran. 510 B-2 26 107072 Rev D 02/21/11

Appendix B BULLETIN DES INSTRUMENTS DE MESURE JUILLET 1985 Groupe pompe dégazeur SATAM EPZ 75/3 N o 4490-1 9 6 4 3 7 5 Section AA exit mousse 18 12 22 8 Liquide 10 11 Liquide dégaze 21 19 20 23 entrance 15 17 16 27 107072 Rev D 02/21/11

Appendix B BULLETIN DES INSTRUMENTS DE MESURE JUILLET 1985 Groupe pompe dégazeur SATAM EPZ 75/5 N o 4490-1 4490-2 9 24 6 4 3 7 5 Section AA exit mousse 18 12 22 8 Liquide 10 11 Liquide dégaze 21 19 20 23 entrance 15 17 16 28 107072 Rev D 02/21/11

Appendix C Inlet & Mounting Dimensions Figure 5 - Meter Flange Outlet Option 29 107072 Rev D 02/21/11

Appendix C Inlet & Mounting Dimensions Figure 6 - Tubular Outlet/Motor Mount Option 30 107072 Rev D 02/21/11

Appendix D Installation Piping for Type 75 Pump Dispenser To obtain maximum flow rates on a self-contained pump, follow these guidelines: 1. The total length of horizontal piping between the pump and tank must be no longer than 60 feet. 2. Piping specifications: a. Use new 1-1/2 galvanized or approved non-metallic pipe for 10-15 GPM pumps. Use new 2 galvanized or approved non-metallic pipe for 20-24 GPM pumps. b. All horizontal piping must be buried a MINIMUM of 18 below the finishing grade. c. The pipe from the tank must slope up to the pump (approximately 1-1/2 to 2 per 10 feet). The pipe MUST be straight. The pipe must be supported continuously to prevent sagging. d. All piping must hold a 50 PSI pressure test for 10 minutes. e. To absorb ground movement from settling of the tank, front heaving of the ground pump or pump island settling, a swing joint must be used in the supply line at the tank and directly underneath the dispenser. Three additional directional changes using elbows are permitted. f. Only one pumping unit is permitted for each underground pipe. Do not use a tee to connect two pumps off one line. 3. Static lift on self contained units must not exceed 10 feet (vertical distance between product level in the storage tank and the center of the pumping unit). 31 107072 Rev D 02/21/11

32 107072 Rev D 02/21/11 Bennett 1218 E. Pontaluna Road, Spring Lake, MI 49456 USA 800-235-7618 ~ Outside USA 231-798-1310 sales@bennettpump.com ~ www.bennettpump.com