High Temperature InfraRed Thermometer with Laser Pointer

Documents pareils
USER GUIDE. Video Borescope. Model BR100

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Manual. Digital Sound Level Meter. Model

Lavatory Faucet. Instruction Manual. Questions?

Folio Case User s Guide

How to Login to Career Page

Paxton. ins Net2 desktop reader USB

Notice Technique / Technical Manual

Instructions Mozilla Thunderbird Page 1

Quick start guide. HTL1170B

Contrôle d'accès Access control. Notice technique / Technical Manual

PAR RINOX INC BY RINOX INC PROGRAMME D INSTALLATEUR INSTALLER PROGRAM

Fabricant. 2 terminals

IPSAS 32 «Service concession arrangements» (SCA) Marie-Pierre Cordier Baudouin Griton, IPSAS Board

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Le No.1 de l économie d énergie pour patinoires.

Monitor LRD. Table des matières

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Le Cloud Computing est-il l ennemi de la Sécurité?

Package Contents. System Requirements. Before You Begin

POLICY: FREE MILK PROGRAM CODE: CS-4

Warning: Failure to follow these warnings could result in property damage, or personal injury.

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Garage Door Monitor Model 829LM

AUTO ER ADAPT ER SPECIAL USE WARNING

SERVEUR DÉDIÉ DOCUMENTATION

Practice Direction. Class Proceedings

worldwide limited warranty and technical support

Contents Windows

LG Electronics, Inc. Display Limited Warranty - USA

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

WEB page builder and server for SCADA applications usable from a WEB navigator

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

ENGLISH 4 FRANÇAIS 6 ESPAÑOL 8

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

GAME CONTENTS CONTENU DU JEU OBJECT OF THE GAME BUT DU JEU

Trim Kit Installation Instruction

Stratégie DataCenters Société Générale Enjeux, objectifs et rôle d un partenaire comme Data4

Gestion des prestations Volontaire

CLASSIFICATION REPORT OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2007

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

CLASSIFICATION REPORT OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2007

DOCUMENTATION - FRANCAIS... 2

Guide d'installation rapide TFM-560X YO.13

22/09/2014 sur la base de 55,03 euros par action

AUDIT COMMITTEE: TERMS OF REFERENCE

Archived Content. Contenu archivé

Spécial Catégorie 6 Patch Cords

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

J. Nexera Distribution assembly instructions consignes d assemblage instrucciones de ensamblaje

DOCUMENTATION MODULE BLOCKCATEGORIESCUSTOM Module crée par Prestacrea - Version : 2.0

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

Nouveautés printemps 2013

Principe de TrueCrypt. Créer un volume pour TrueCrypt

Swap: Utilisation et risques Approche de gestion pour les consommateurs

Quick Installation Guide TEW-AO12O

DOCUMENTATION - FRANCAIS... 2

Editing and managing Systems engineering processes at Snecma

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

PVCHECK Rel /11/12

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Sécurité relative aux sièges auto et aux rehausseurs

THE LAW SOCIETY OF UPPER CANADA BY-LAW 19 [HANDLING OF MONEY AND OTHER PROPERTY] MOTION TO BE MOVED AT THE MEETING OF CONVOCATION ON JANUARY 24, 2002

86 rue Julie, Ormstown, Quebec J0S 1K0

APPENDIX 6 BONUS RING FORMAT

Utiliser une WebCam. Micro-ordinateurs, informations, idées, trucs et astuces

RAPID Prenez le contrôle sur vos données

PRACTICE DIRECTION ON THE LENGTH OF BRIEFS AND MOTIONS ON APPEAL

RICHEL SERRES DE FRANCE PAR_ _02432_ALT DATE: 03/02/2012

Exercices sur SQL server 2000

CLIM/GTP/27/8 ANNEX III/ANNEXE III. Category 1 New indications/ 1 re catégorie Nouvelles indications

PRESENTATION REMOTE TÉLÉCOMMANDE DE PRÉSENTATION. User Guide Manuel de l utilisateur

Comprendre l impact de l utilisation des réseaux sociaux en entreprise SYNTHESE DES RESULTATS : EUROPE ET FRANCE

FCM 2015 ANNUAL CONFERENCE AND TRADE SHOW Terms and Conditions for Delegates and Companions Shaw Convention Centre, Edmonton, AB June 5 8, 2015

12, Chemin de la Forge L Islet (Québec) G0R 1X0 CANADA

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

Frequently Asked Questions

Owner's Manual RSB-1410

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

accidents and repairs:

Guide d installation Deco Drain inc. DD200

Discours du Ministre Tassarajen Pillay Chedumbrum. Ministre des Technologies de l'information et de la Communication (TIC) Worshop on Dot.

Laboratory accredited by the French Home Office (official gazette date February 5 th, 1959, modified) Valid five years from August 27 th, 2013

PARIS ROISSY CHARLES DE GAULLE

Application Form/ Formulaire de demande

USB 598. Quick Start Guide (Windows) Guide de démarrage rapide (Windows) USB Modem. Modem USB.

Créé par Goldfing & Pblabla Créé le 02/05/ :49:00. Guide pour la déclaration d impôt

Once the installation is complete, you can delete the temporary Zip files..

Contrôle d accès Access control MOD-TCPIP-AI. Notice technique / Technical Manual

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

Transcription:

User s Manual High Temperature InfraRed Thermometer with Laser Pointer MODEL 42540A 6 42540

6 Introduction Congratulations on your purchase of the Model 42540A IR Thermometer. The 42540A is capable of non-contact (infrared) temperature measurements at the touch of a button. The built-in laser pointer increases target accuracy while the backlit LCD and handy push-buttons combine for convenient, ergonomic operation. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Safety Use extreme caution when the laser pointer beam is on Do not point the beam toward anyone's eye or allow the beam to strike the eye from a reflective surface Do not use the laser near explosive gases or in other potentially explosive areas Meter Description 1. Laser pointer beam 2. IR Sensor 3. Measurement Trigger 4. Battery and Switch Compartment 5. LCD Display 6. Push-buttons 7. Handle Grip 8. Temperature Units (ºC/ºF) Switch 9. Test Lock ON/OFF Switch 10. Alarm ON/OFF Switch Note: There is a tripod mount on the bottom of the handle 1 2 5 3 6 42540 4 8 9 10 7 2

Operating Instructions Basic IR Measurements 1. Hold the meter by its handle and point it toward the surface to be measured. 2. Pull and hold the trigger to turn the meter on and begin testing. The temperature reading, the flashing SCAN icon, the emissivity, and the unit of measure will appear. Note: Replace the 9V battery if the display does not switch on. 3. Release the Trigger and the reading will hold for approximately 7 seconds (HOLD will appear on the LCD) after which the meter will automatically shut off. The only exception to this is if the TEST LOCK switch is set to ON. Note: Select the temperature units (ºF/ºC) using the top switch inside the battery compartment Backlight/Laser Pointer 1. While pulling the Trigger, push the backlight/laser button once to turn on the backlight. 2. Press it again to turn on the laser pointer. When the laser is ON the laser icon will appear in the LCD. 3. Press the laser button to turn the backlight off. 4. Pressing it again turns the laser off. Note: Backlight and Laser settings will be retained after the meter powers down. Over-range Indication If the temperature measurement exceeds the specified temperature range, the thermometer will display dashes in place of a temperature reading. 3

The MODE button options The MODE button is used to access the programming functions of the instrument. The selected function is displayed on the bottom line of the LCD. Each parameter is listed below with an explanation for its use. Press the MODE button to step from one parameter to the next. EMS (Emissivity Value) To change the emissivity value, use the UP and DOWN arrows (the range is 0.10 to 1.00). The current emissivity setting is always shown at the top of the LCD display. A setting of 0.95 covers about 90% of all applications and, when in doubt, should be set as such. Emissivity is discussed in a dedicated section of this manual. MAX (Maximum function) In the MAX mode, only the highest reading encountered in the current measurement session is displayed MIN (Minimum function) In the MIN mode, only the lowest reading is displayed DIF (Max minus Min value) In the DIF mode, the MAX less the MIN is displayed. AVG (Average value) In the AVG mode, all of the readings in the current measurement session are averaged and the value is displayed. HAL (High Alarm setting) The temperature that, when exceeded, causes the audible/visual alarm to trip. LAL (Low Alarm setting) The temperature that, when exceeded high to low, causes the audible/visual alarm to trip. High and Low Alarm Feature The Model 42540a has an alarm feature whereas a High Alarm setting and a Low Alarm setting can be programmed by the user. When either Alarm point is reached the meter will alert the user via an audible beep and LCD display icon. Follow the steps below: 1. Press the MODE button until the HAL (High Alarm) parameter is displayed. Use the UP and DOWN arrow keys to set the desired High Alarm temperature setting. 2. Press the MODE button until the LAL (Low Alarm) parameter is displayed. Use the UP and DOWN arrow keys to set the desired Low Alarm temperature setting. 3. When an alarm limit is reached, the audible alarm will sound and the display icon HIGH or LOW will appear on the LCD. 4. Note that if the bottom switch (located in the battery compartment) is set to OFF, the audible alarm will be disabled. 4

Battery Replacement When the battery symbol appears empty or close to empty, replace the meter s 9V battery. The battery compartment is located behind the panel that surrounds the meter s trigger. The panel can be pried open near the trigger and folded down as shown in the diagram. Replace the 9V battery and close the battery compartment cover. IR Measurement Notes 1. The object under test should be larger than the spot (target) size calculated by the field of view diagram (printed on the side of the meter and in this guide). 2. Before measuring, be sure to clean surfaces that are covered with frost, oil, grime, etc. 3. If an object's surface is highly reflective, apply masking tape or flat black paint to the surface before measuring. Allow time for the paint or tape to adjust to the temperature of the surface it is covering. 4. Measurements through transparent surfaces such as glass may not be accurate. 5. Steam, dust, smoke, etc. can obscure measurements. 6. The meter automatically compensates for deviations in ambient temperature. However, it can take up to 30 minutes for the meter to adjust to extremely wide changes. 7. To find a hot spot, aim the meter outside the area of interest then scan across (in an up and down motion) until the hot spot is located. Field of View The meter s field of view is 16:1. For example, if the meter is 16 inches from the target (spot), the diameter of the target must be at least 1 inch. Other distances are shown in the field of view diagram. Note that measurements should normally be made as close as possible to the device under test. The meter can measure from moderate distances but the measurement may be affected by external sources of light. In addition, the spot size may be so large that it encompasses surface areas not intended to be measured. 5

Emissivity and IR Measurement Theory IR Thermometers measure the surface temperature of an object. The thermometer s optics sense emitted, reflected, and transmitted energy. The thermometer s electronics translate the information into a temperature reading which is then displayed on the LCD. The amount of IR energy emitted by an object is proportional to an object's temperature and its ability to emit energy. This ability is known as emissivity and is based upon the material of the object and its surface finish. Emissivity values range from 0.1 for a very reflective object to 1.00 for a flat black finish. For the Model 42540a, the emissivity is adjustable from 0.1 to 1.00. Most organic materials and painted or oxidized surfaces have an emissivity factor of 0.95. When in doubt, set the emissivity to 0.95. Emissivity Factors for Common Materials Material under test Emissivity Material under test Emissivity Asphalt 0.90 to 0.98 Cloth (black) 0.98 Concrete 0.94 Skin (human) 0.98 Cement 0.96 Leather 0.75 to 0.80 Sand 0.90 Charcoal (powder) 0.96 Soil 0.92 to 0.96 Lacquer 0.80 to 0.95 Water 0.92 to 0.96 Lacquer (matt) 0.97 Ice 0.96 to 0.98 Rubber (black) 0.94 Snow 0.83 Plastic 0.85 to 0.95 Glass 0.90 to 0.95 Timber 0.90 Ceramic 0.90 to 0.94 Paper 0.70 to 0.94 Marble 0.94 Chromium Oxides 0.81 Plaster 0.80 to 0.90 Copper Oxides 0.78 Mortar 0.89 to 0.91 Iron Oxides 0.78 to 0.82 Brick 0.93 to 0.96 Textiles 0.90 6

Specifications Infrared Thermometer Specifications Range / Resolution -58 to 1400 o F (-50 to 760 o C) 0.1 o C/F over entire range Accuracy (of reading) ± 2% of reading or 4 o F (2 o C) whichever is greater < 932 o F (500 o C) ± (2.5% of reading + 5 o ) > 932 o F (500 o C) Note: Accuracy is specified for the following ambient temperature range: 64 to 82 F (18 to 28 C) Emissivity Adjustable from 0.1 to 1.00 (0.95 default value) Field of View D/S = Approx. 16:1 ratio (D = distance, S = spot) Laser power Less than 1mW Spectral response 6 to 14 m (wavelength) General Specifications Display Display rate 4½ digit backlit LCD display with function indicators 1 second approx. Operating Temperature 32 F to 122 F (0 C to 50 C) Operating Humidity Power Supply Automatic Power Off Safety compliance Weight Dimensions Max. 80% RH. 9V battery Approx. 6 seconds after the trigger is released CE 10.2 oz. / 290g 3.9 x 2.2 x 9.0 (100 x 56 x 230mm) 7

Warranty (3 years) FLIR Systems, Inc. warrants this Extech Instruments brand device to be free of defects in parts and workmanship for three years from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department for authorization. Visit the website for contact information. A Return Authorization (RA) number must be issued before any product is returned. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. FLIR Systems, Inc. specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. FLIR s total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration, Repair, and Customer Care Services FLIR Systems, Inc. offers repair and calibration services for the Extech Instruments products we sell. NIST certification for most products is also provided. Call the Customer Service Department for information on calibration services available for this product. Annual calibrations should be performed to verify meter performance and accuracy. Technical support and general customer service is also provided, refer to the contact information provided below. Support Lines: U.S. (877) 439 8324; International: +1 (603) 324 7800 Technical Support: Option 3; E mail: support@extech.com Repair & Returns: Option 4; E mail: repair@extech.com Product specifications are subject to change without notice Please visit our website for the most up to date information FLIR Commercial Systems, Inc., 9 Townsend West, Nashua, NH 03063 USA ISO 9001 Certified Copyright 2013 2016 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form 8

Garantie (3 years) FLIR Systems, Inc. garantit que cet appareil Extech Instruments est exempt de défauts matériaux et de fabrication pendant Trois ans à partir de la date d envoi (une garantie limitée de six mois s applique aux capteurs et aux câbles). Si le renvoi de l appareil pour réparation devient nécessaire durant ou après la période de garantie, contactez le service client pour autorisation. Pour obtenir les coordonnées, visitez le site Web suivant :. Un numéro d autorisation de retour (AR) doit être délivré avant tout retour de produit. L expéditeur prend à sa charge les frais d expédition, le fret, l assurance et l emballage correct de l appareil afin de prévenir toute détérioration durant le transport. Cette garantie ne s applique pas aux dommages imputables à l utilisateur, tels que l usage impropre ou abusif, un mauvais câblage, une utilisation non conforme aux spécifications, un entretien ou une réparation incorrecte, ou toute modification non autorisée. FLIR Systems, Inc. déclinera spécifiquement toute garantie ou qualité marchande ou aptitude à l emploi prévu, et ne sera en aucun cas tenu responsable pour tout dommage conséquent, direct, indirect ou accidentel. La responsabilité totale de FLIR est limitée à la réparation ou au remplacement du produit. La garantie définie ci dessus est inclusive et aucune autre garantie, écrite ou orale, n est exprimée ou implicite. Calibrage, réparation et services après vente FLIR Systems, Inc. offre des services de calibrage et de réparation pour les produits Extech Instruments que nous commercialisons. Nous fournissons également une certification NIST pour la plupart des produits. Contactez notre service client pour toute information sur les services de calibrage disponibles pour ce produit. Un calibrage doit être effectué chaque année pour vérifier les performances et la précision du mètre. Nous offrons également une assistance technique et un service à la clientèle. Veuillez vous reporter aux coordonnées fournies ci dessous. Lignes d assistance: États Unis (877) 439 8324 International: +1 (603) 324 7800 Service d assistance technique : Option 3 ; E mail : support@extech.com Réparations et retours : Option 4 ; E mail : repair@extech.com Les spécifications produit sont sujettes à modifications sans préavis. Pour les toutes dernières informations, veuillez visiter notre site Web. FLIR Commercial Systems, Inc., 9 Townsend West, Nashua, NH 03063 USA Certifié ISO 9001 Copyright 2013 2016 FLIR Systems, Inc. Tous droits réservés, y compris la reproduction partielle ou totale sous quelque forme que ce soit. 9

Garantía (3 years) FLIR Systems, Inc. garantiza este "Extech Instruments" como dispositivo de estar libre de defectos en partes o mano de obra durante tres años a partir de la fecha de embarque (se aplica una garantía limitada de seis meses para cables y sensores). Si fuera necesario regresar el instrumento para servicio durante o después del periodo de garantía, llame al Departamento de Servicio a Clientes para obtener autorización. Visite para Información de contacto. Se debe expedir un número de Autorización de Devolución (AD) antes de regresar cualquier producto. El remitente es responsable de los gastos de embarque, flete, seguro y empaque apropiado para prevenir daños en tránsito. Esta garantía no se aplica a defectos resultantes de las acciones del usuario como el mal uso, alambrado equivocado, operación fuera de las especificaciones, mantenimiento o reparación inadecuada o modificación no autorizada. FLIR Systems, Inc., rechaza específicamente cualesquier garantías implícitas o factibilidad de comercialización o idoneidad para cualquier propósito determinado y no será responsable por cualesquier daños directos, indirectos, incidentales o consecuentes. La responsabilidad total de FLIR está limitada a la reparación o reemplazo del producto. La garantía precedente es inclusiva y no hay otra garantía ya sea escrita u oral, expresa o implícita. Servicios de calibración, reparación y atención a clientes FLIR Systems, Inc., ofrece servicios de reparación y calibración para los productos que vendemos de Extech Instruments. Además ofrecemos certificación NIST para la mayoría de los productos. Llame al Departamento de Servicio al Cliente para solicitar información de calibración para este producto. Para verificar el funcionamiento y precisión se debe realizar la calibración anual. Además se provee Soporte Técnico y servicios generales al cliente, consulte la información de contacto en seguida. Líneas de soporte: EE.UU. (877) 439 8324 Internacional: +1 (603) 324 7800 Soporte Técnico Opción 3; correo electrónico: support@extech.com Reparación / Devoluciones: Opción 4; correo electrónico: repair@extech.com Las especificaciones del producto están sujetas a cambios sin aviso Por favor visite nuestra página en Internet para la información más actualizada FLIR Commercial Systems, Inc., 9 Townsend West, Nashua, NH 03063 USA Certificado ISO 9001 Copyright 2013 2016 FLIR Systems, Inc. Reservados todos los derechos, incluyendo el derecho de reproducción total o parcial en cualquier medio 10