Clearview Front 545CFV Approved for use with Valor heater model 530 only in insert applications (See 545CFVZC for zero clearance applications)

Documents pareils
Instructions Mozilla Thunderbird Page 1

Folio Case User s Guide

Lavatory Faucet. Instruction Manual. Questions?

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

R.V. Table Mounting Instructions

Warning: Failure to follow these warnings could result in property damage, or personal injury.

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Application Form/ Formulaire de demande

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Guide d installation Deco Drain inc. DD200

Le No.1 de l économie d énergie pour patinoires.

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

GASKET FOR TONER COLLECTION BOTTLE

Monitor LRD. Table des matières

Contents Windows

Paxton. ins Net2 desktop reader USB

APPENDIX 6 BONUS RING FORMAT

Notice Technique / Technical Manual

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Archived Content. Contenu archivé

Stainless Steel Solar Wall Light

Gestion des prestations Volontaire

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

INSTITUT MARITIME DE PREVENTION. For improvement in health and security at work. Created in 1992 Under the aegis of State and the ENIM

F1 Security Requirement Check List (SRCL)

Frequently Asked Questions

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

Le passé composé. C'est le passé! Tout ça c'est du passé! That's the past! All that's in the past!

FÉDÉRATION INTERNATIONALE DE NATATION Diving

Contrôle d'accès Access control. Notice technique / Technical Manual

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

Editing and managing Systems engineering processes at Snecma

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

IPSAS 32 «Service concession arrangements» (SCA) Marie-Pierre Cordier Baudouin Griton, IPSAS Board

Sécurité relative aux sièges auto et aux rehausseurs

en SCÈNE RATIONAL Rational Démonstration SDP : automatisation de la chaîne de développement Samira BATAOUCHE sbataouche@fr.ibm.com

PRINCIPE DE HOTTE SPÉCIALE COMPLÈTE TYPE «RHC» COMPLETE «RHC» TYPE SPECIAL HOOD SYSTEM

MEMORANDUM POUR UNE DEMANDE DE BOURSE DE RECHERCHE DOCTORALE DE LA FONDATION MARTINE AUBLET

Package Contents. System Requirements. Before You Begin

If the corporation is or intends to become a registered charity as defined in the Income Tax Act, a copy of these documents must be sent to:

Once the installation is complete, you can delete the temporary Zip files..

Stratégie DataCenters Société Générale Enjeux, objectifs et rôle d un partenaire comme Data4

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

Guide d'installation rapide TFM-560X YO.13

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Township of Russell: Recreation Master Plan Canton de Russell: Plan directeur de loisirs

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

Laboratory accredited by the French Home Office (official gazette date February 5 th, 1959, modified) Valid five years from August 27 th, 2013

Lesson Plan Physical Descriptions. belle vieille grande petite grosse laide mignonne jolie. beau vieux grand petit gros laid mignon

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Exercices sur SQL server 2000

If you understand the roles nouns (and their accompanying baggage) play in a sentence...

RAPID Prenez le contrôle sur vos données

FCM 2015 ANNUAL CONFERENCE AND TRADE SHOW Terms and Conditions for Delegates and Companions Shaw Convention Centre, Edmonton, AB June 5 8, 2015

accidents and repairs:

How to Login to Career Page

MODE D EMPLOI USER MANUAL

Utiliser une WebCam. Micro-ordinateurs, informations, idées, trucs et astuces

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

lundi 3 août 2009 Choose your language What is Document Connection for Mac? Communautés Numériques L informatique à la portée du Grand Public

Utiliser un proxy sous linux

Cedric Dumoulin (C) The Java EE 7 Tutorial

CLIM/GTP/27/8 ANNEX III/ANNEXE III. Category 1 New indications/ 1 re catégorie Nouvelles indications

22/09/2014 sur la base de 55,03 euros par action

Consultants en coûts - Cost Consultants

Embases pour raccordement G1/8 - G1/4

MEMORANDUM POUR UNE DEMANDE DE BOURSE DE RECHERCHE DOCTORALE DE LA FONDATION MARTINE AUBLET

POLICY: FREE MILK PROGRAM CODE: CS-4

Now enhanced with powerful workplace solutions Maintenant amélioré, diet+ vous offre de puissantes solutions novatrices pour le milieu de travail

DOCUMENTATION - FRANCAIS... 2

Stéphane Lefebvre. CAE s Chief Financial Officer. CAE announces Government of Canada participation in Project Innovate.

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

Installation d'un TSE (Terminal Serveur Edition)

France SMS+ MT Premium Description

Trim Kit Installation Instruction

ÉTUDES MÉDICALES DE PREMIER CYCLE

Maximum Capacity / Capacité maximal: 10 kg/min

Dates and deadlines

1.The pronouns me, te, nous, and vous are object pronouns.

Curve. Innover pour simplifier! Mistral signe les fontaines High Tech à hauteur adaptable. Mistral signs the High Tech coolers with adaptable height

ETABLISSEMENT D ENSEIGNEMENT OU ORGANISME DE FORMATION / UNIVERSITY OR COLLEGE:

CEST POUR MIEUX PLACER MES PDF

Institut français des sciences et technologies des transports, de l aménagement

OBJECT PRONOUNS. French III

Fabricant. 2 terminals

Nouveautés printemps 2013

L. Obert, T. Lascar, A. Adam

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Bourses d excellence pour les masters orientés vers la recherche

Titulaires de marques

Natixis Asset Management Response to the European Commission Green Paper on shadow banking

Transcription:

Clearview Front 545CFV Approved for use with Valor heater model 530 only in insert applications (See 545CFVZC for zero clearance applications)! Installation and Owner s Manual DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. The Clearview Front is intended to install on the Valor Portrait 530 appliance when installed as an insert application. Use the 545CFVZC for zero clearance applications. PORTRAIT Heat Exchanger Cover INSTALLER Leave this manual with the appliance. CONSUMER Retain this manual for future reference. Notes: This kit must be installed or serviced by a qualified installer, service agency or gas supplier. These instructions are to be used in conjunction with the main installation instructions for the above listed heater models. Bridging Baffle 530 Engine Backing Frame Assembly Backing Plate (26 w x 31 h) Optional 583CPB Backing Plate (30 w x 33 h) 4005031-02 2015, Miles Industries Ltd. Clearview Front with Barrier Screen Lower Panel Optional 545TFB Cast Iron Fret Overview (530I, 583CPB and 545TFB sold separately)

Kit Contents 545CFV 1 Backing Frame assembly 1 Backing plate 1 Clearview Front assembly 1 Heat Exchanger Cover 1 Lower Panel 1 Bridging Baffl e 1 Barrier Screen (fi tted) 9 #8 X 1/4 Screws 6 #8 X 3/8 Screws Heat Exchanger Cover Bridging Baffle Backing Frame Assembly Backing Plate Clearview Front with Barrier Screen Dimensions and Clearances 20 (508 mm) Lower Panel Mantel Clearances 6-5/8 dia. Mantel Depth A Mantel Height B 0 6 (0 152 mm) 4 (102 mm) 8 (203 mm) 8 (203 mm) 10 (254 mm) 10 (254 mm) 12 (305 mm) 12 (305 mm) A Mantel 26 (660 mm) 22 (559 mm) 2 (51 mm) sidewall minimum clearance B 3/4 (19 mm) 11-3/8 (289 mm) 4-7/16 (113 mm) 31 (787 mm) 28 (771 mm) Do not put furniture or objects within 36 (914 mm) of front of appliance 21-1/8 (537 mm) 25-1/4 (641 mm) 2

Installation 1. Fit the bridging baffl e under the top panel of the appliance case. Secure as shown with 2 thread forming screws provided. 4. Position and secure the backing plate to the frame assembly using 9 screws provided. Note: As the painting process is automated and the backing plate is symmetrical, ensure the preferred fi nished side is visible to the homeowner. 2. Locate and slide rear backing plate assembly to fi rebox, and secure with 4 screws provided. 5. If using the larger 583CPB closure plate, install it now overtop of the backing plate (see page 5). 6. Locate the heat exchanger cover into place; note shape and orientation to be as shown below. 3. Proceed with the installation of the fi rebox, gas fi tting, venting, fuel bed and so on as per appliance s instructions manual. For mounting closure plate 583CPB refer to page 5 3

7. Hook the Clearview front onto the backing plate. 545TFB Traditional Fret (Optional) Casting Tolerances Due to the nature of cast iron, dimensional consistency may vary from one unit to the next and some variation in surface fi nish and fl atness is to be expected. We have done our best to control and make allowance for this; however some variation is inevitable. Installation The Clearview kit is supplied with a Lower Panel to cover the controls. The 545FTB Traditional Fret replaces the Lower Panel. 1. Remove the lower panel; discard or recycle. 2. Hook the fret to the Clearview front. 8. Position the lower panel into the space underneath the barrier screen and hook into place. 4

583CPB Closure Plate (optional) Mounting of the 583 does not affect clearances or other specifi cations listed in the heater installation manuals see installation manual supplied with the heater for more information. Dimensions 30 (762 mm) Installation 1. At the point of securing the standard Clearview Backing plate, overlay the 583 Plate on top of the standard one. 2. Secure both plates together to the backing plate support with 9 screws supplied. 33 (838 mm) Material required Material required to install with 545CFV Clearview: Closure plate 583 Reserve set (#8 3/4 Screw 4005264 (9)) Note: Additional parts supplied in 583CPB kit, NOT required when installed with 545CFV. Note: The supplied fi xing screws (9) with 545CFV are too short for both plates, and there s clearance behind the fi rebox, use the longer screws that come with the 583CPB kit. Cleaning! WARNING DO NOT TOUCH THE BARRIER SCREEN, THE CAST FRONT OR THE GLASS WHILE THEY ARE HOT! Let the fireplace cool first before cleaning it.! WARNING FOR YOUR SAFETY, ensure the barrier screen is reinstalled on the fireplace after maintenance. To clean the barrier screen and the front use a soft brush. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer s barrier for this appliance. To clean the fireplace glass window, refer to the owner s manual supplied with the appliance. DO NOT clean the glass with ammonia. Always securely replace the window, the front and the barrier screen before lighting. 5

Repair Parts List # Description Number 10 1 Backing Plate (31 h x 26 w) 4004891AZ 2 Backing Frame Assembly 4004890AZ 3 Bridging Baffl e 4005218BY 4 Clearview Front Assembly 4004894 5 Heat Exchanger Cover 4004904BY 6 Barrier Screen Assembly 4005146 7 Lower Panel 4004899AZ 8 Mounting Bracket assembly (545TFB) 4005079AH 9 Fret Casting Assembly (545TFB) 4000839AH 10 Closure plate 33 h x 30 w (583CPB) 4005198AZ 3 2 5 6 8 1 4 7 9 Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. Designed and Manufactured by / for Miles Industries Ltd. 190 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfireplaces.com 6

LE PREMIER MC FOYER À GAZ RADIANT Devanture Clearview 545CFV Homologuée pour usage avec le foyer Valor 530 seulement installé comme encastrable (Consultez le modèle 545CFVZC pour installations à dégagement zéro)! PORTRAIT Directives d installation DANGER VITRE CHAUDE - RISQUE DE BRÛLURES. NE TOUCHEZ PAS UNE VITRE NON REFROIDIE. NE LAISSEZ JAMAIS UN ENFANT TOUCHER LA VITRE. L écran pare-étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection des enfants et des personnes à risques. INSTALLATEUR Laissez cette notice avec l appareil. CONSOMMATEUR Conservez cette notice pour consultation ultérieure. Notes : Ce kit doit être installé ou réparé par un installateur qualifi é, une agence de service certifi ée ou un fournisseur de gaz. Ces directives doivent être utilisées conjointement avec les directives d installation du foyer Valor indiqué ci-dessus. La Devanture Clearview est conçue pour installer sur le foyer Valor Portrait 530 dans les applications encastrables. Pour les applications à dégagement zéro, utilisez la Devanture Clearview 545CFVZC. Couvercle d échangeur de chaleur Déflecteur Foyer 530 Support de la plaque de finition Plaque de finition (26 L 31 H) Plaque de finition 583CPB facultative (30 L 33 H) Devanture Clearview avec pare-étincelles Panneau du bas Base de fonte 545TFB facultative Concept (530I, 583CPB et 545TFB vendus séparément) 7

Contenu du kit 545CFV 1 Support de plaque de fi nition 1 Plaque de fi nition 1 Devanture Clearview 1 Couvercle d échangeur de chaleur 1 Panneau du bas 1 Bridging Baffl e 1 Pare-étincelles (installé) 9 Vis n o 8 X 1/4 6 Vis n o 8 X 3/8 Couvercle d échangeur de chaleur Déflecteur Support de la plaque de finition Plaque de finition Devanture Clearview avec pare-étincelles Dimensions et Dégagements 20 (508 mm) Panneau du bas Dégagements pour manteau 6-5/8 dia. Profondeur A Hauteur B 0 6 (0 152 mm) 4 (102 mm) 8 (203 mm) 8 (203 mm) 10 (254 mm) 10 (254 mm) 12 (305 mm) 12 (305 mm) A Manteau 26 (660 mm) 22 (559 mm) 2 (51 mm) dégagement minimum d un mur de côté B 3/4 (19 mm) 11-3/8 (289 mm) 4-7/16 (113 mm) 31 (787 mm) 28 (771 mm) Ne placez aucun meuble ou objet à moins de 36 (914 mm) de la façade du foyer 21-1/8 (537 mm) 25-1/4 (641 mm) 8

Installation 1. Placez le défl ecteur sous la paroi de la caisse du foyer. Fixez-le avec deux vis autotaraudeuse fournies. 4. Placez la plaque de fi nition contre le support et fi xez-la avec neuf vis fournies. Note : Comme la peinture est appliquée à la plaque de fi nition de façon automatisée et que la plaque est symétrique. Installez la plaque du côté préféré par le consommateur. 2. Alignez et glissez le support de plaque de fi nition sur la caisse du foyer. Fixez-le à l aide de quatre vis fournies. 5. Si vous utilisez la Plaque de fi nition plus large 583CPB, installez-la par-dessus la plaque fournie avec le kit voir page 11. 6. Placez le couvercle d échangeur de chaleur tel qu indiqué ci-dessous. Notez sa forme et son orientation. 3. Continuez l installation du foyer, le raccordement au gaz, le montage du système d évacuation, l installation des panneaux et lit d alimentation et ainsi de suite selon les directives d installation fournies avec le foyer. Pour l installation de la Plaque de finition 583CPB, consultez la page 11 9

7. Accrochez la devanture Clearview à la plaque de fi nition. Base de fonte traditionnelle 545TFB (facultative) Variations de la fonte De par leur nature, deux articles de fonte fabriqués du même moule peuvent montrer de légères variations dans leurs dimensions et leur fi nition. Nous faisons tout ce qui est possible pour limiter ces variations qui ne peuvent cependant pas être éliminées. Installation La Devanture Clearview est fournie avec le panneau du bas qui couvre les commandes au bas de l appareil. La Base de fonte traditionnelle 545TFB remplace le panneau du bas. 1. Enlevez le panneau du bas; jetez-le ou recyclez-le. 2. Accrochez la base de fonte à la devanture. 8. Accrochez le panneau du bas sous le pareétincelles à la base de la devanture. 10

Plaque de finition 583CPB (facultative) L installation de la Plaque de fi nition 583CPB n affecte pas les dégagements ou autres spécifi cations indiquées dans le guide d installation fourni avec le foyer. Dimensions 2. Fixez les deux plaques de fi nition ensemble au support installé sur la caisse du foyer à l aide des 9 vis fournies avec la grande plaque. 30 (762 mm) 33 (838 mm) Note : Les neuf vis fournies avec le kit 545CFV sont trop courtes pour fi xer les deux plaques ensemble au foyer. S il y a de l espace derrière la caisse de l appareil, utilisez les plus longues fournies avec la grande plaque de fi nition 583CPB. Matériel requis Pièces requises pour l installation avec la Devanture Clearview 545CFV : Plaque de fi nition 583 9 Vis n o 8 3/4, pièce n o 4005264 Note : Les pièces additionnelles fournies avec la Plaque de fi nition 583CPB ne sont PAS utilisées lors de l installation avec le 545CFV. Installation 1. Au moment d installer la plaque de fi nition dans l installation de la Devanture Clearview, ajoutez la plaque de fi nition plus grande 583 par-dessus celle du 545. Entretien! AVERTISSEMENT NE TOUCHEZ PAS LE PARE-ÉTINCELLES, LA DEVANTURE OU LA FENÊTRE LORSQU ILS SONT CHAUDS! Laissez le foyer refroidir avant de le nettoyer.! AVERTISSEMENT POUR RAISONS DE SÉCURITÉ, assurez-vous que le pare-étincelles soit réinstallé sur le foyer après l entretien. Pour nettoyer le pare-étincelles et les surfaces matte noire en fonte, utilisez une brosse souple. Si le pare-étincelles est endommagé, il doit être remplacé par le pare-étincelles conçu par le manufacturier pour cet appareil. Pour nettoyer la vitre de la fenêtre du foyer, consultez le guide du consommateur fourni avec le foyer. NE PAS nettoyer la vitre avec un produit à base d ammoniaque. Toujours remettre la fenêtre, la devanture et le pare-étincelles en place et les fixer solidement avant d allumer le foyer. 11

Liste de pièces # Description N o de pièce 10 1 Plaque de fi nition (31 H sur 26 L) 4004891AZ 2 Support de montage de plaque de fi nition 4004890AZ 3 Défl ecteur 4005218BY 4 Devanture Clearview 4004894 5 Couvercle d échangeur de chaleur 4004904BY 6 Pare-étincelles 4005146 7 Panneau du bas 4004899AZ 8 Support de montage (545TFB) 4005079AH 9 Base de fonte (545TFB) 4000839AH 10 Plaque de fi nition 583CPB (33 H sur 30 L) 4005198AZ 3 2 5 6 8 1 4 7 9 Parce que nous favorisons une politique de développement continu, certains détails de la présente publication peuvent varier. Conçu(e) et fabriqué(e) par / pour Miles Industries Ltd. 190 2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tél. 604-984-3496 Téléc. 604-984-0246 www.foyervalor.com 12