Powermax45 Power Switch Replacement Kit Kit de remplacement de l interrupteur d alimentation du Powermax45

Documents pareils
GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Folio Case User s Guide

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Sécurité relative aux sièges auto et aux rehausseurs

Logitech Speaker System Z553 Setup Guide Guide d installation

Contents Windows

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

R.V. Table Mounting Instructions

Notice Technique / Technical Manual

Lavatory Faucet. Instruction Manual. Questions?

Package Contents. System Requirements. Before You Begin


SERVEUR DÉDIÉ DOCUMENTATION

ENGLISH 4 FRANÇAIS 6 ESPAÑOL 8

Instructions Mozilla Thunderbird Page 1

Contrôle d'accès Access control. Notice technique / Technical Manual

SYSTÈME DE GAINES À SPIRALE ET RACCORDS TOURNANTS

Guide d'installation rapide TFM-560X YO.13

Quick start guide. HTL1170B

Now enhanced with powerful workplace solutions Maintenant amélioré, diet+ vous offre de puissantes solutions novatrices pour le milieu de travail

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

Paxton. ins Net2 desktop reader USB

en SCÈNE RATIONAL Rational Démonstration SDP : automatisation de la chaîne de développement Samira BATAOUCHE sbataouche@fr.ibm.com

Once the installation is complete, you can delete the temporary Zip files..

22/09/2014 sur la base de 55,03 euros par action

Sun StorageTek 2500 Series

POLICY: FREE MILK PROGRAM CODE: CS-4

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Stérilisation / Sterilization

WEB page builder and server for SCADA applications usable from a WEB navigator

GASKET FOR TONER COLLECTION BOTTLE

Table des matières QUINCAILLERIE FONCTIONNEL FUNCTIONAL HARDWARE. Clé H1 Serrure et pêne H2. Serrure à levier H4

Le No.1 de l économie d énergie pour patinoires.

Start Here Point de départ Epson Stylus

DOCUMENTATION - FRANCAIS... 2

Exemple PLS avec SAS

Embases pour raccordement G1/8 - G1/4

ADMINISTRATION DE ADOBE LIVECYCLE MOSAIC 9.5

Trim Kit Installation Instruction

Microsoft Lync de votre bureau à la salle de conférence

Z-Axis Compliance Device Compliance en z

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

GAME CONTENTS CONTENU DU JEU OBJECT OF THE GAME BUT DU JEU

Start Here Point de départ

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

Institut français des sciences et technologies des transports, de l aménagement

Nordion Europe S.A. Incorporation Authorization Order. Décret autorisant la constitution de Nordion Europe S.A. CONSOLIDATION CODIFICATION

PAR_ _09543_EUR DATE: 17/12/2014. Suite à l'avis PAR_ _08654_EUR

Tom Pertsekos. Sécurité applicative Web : gare aux fraudes et aux pirates!

PRESENTATION REMOTE TÉLÉCOMMANDE DE PRÉSENTATION. User Guide Manuel de l utilisateur

Logitech Wireless Performance Combo MX800 Setup Guide Guide d installation

Comfort Duett. TV-kit. USA: English/Français/Español. Comfort Duett

Material Banking Group Percentage Regulations. Règlement fixant le pourcentage (groupe bancaire important) CONSOLIDATION CODIFICATION

DOCUMENTATION MODULE BLOCKCATEGORIESCUSTOM Module crée par Prestacrea - Version : 2.0

Monitor LRD. Table des matières

The impacts of m-payment on financial services Novembre 2011

SunATM 4.0 Release Notes

Multiple issuers. La cotation des actions ROBECO ci-dessous est suspendue sur EURONEXT PARIS dans les conditions suivantes :

PHANTOM. Manuel Avancé. V Révision DJI Innovations. All Rights Reserved. 1

PARIS ROISSY CHARLES DE GAULLE

Gestion des prestations Volontaire

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

MODE D EMPLOI USER MANUAL

lundi 3 août 2009 Choose your language What is Document Connection for Mac? Communautés Numériques L informatique à la portée du Grand Public

Le passé composé. C'est le passé! Tout ça c'est du passé! That's the past! All that's in the past!

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

RAPID Prenez le contrôle sur vos données

INSTITUT MARITIME DE PREVENTION. For improvement in health and security at work. Created in 1992 Under the aegis of State and the ENIM

How to Login to Career Page

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

Micro-ordinateurs, informations, idées, trucs et astuces utiliser le Bureau à distance

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

Le Cloud Computing est-il l ennemi de la Sécurité?

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Principe de TrueCrypt. Créer un volume pour TrueCrypt

86 rue Julie, Ormstown, Quebec J0S 1K0

LE FORMAT DES RAPPORTS DU PERSONNEL DES COMMISSIONS DE DISTRICT D AMENAGEMENT FORMAT OF DISTRICT PLANNING COMMISSION STAFF REPORTS

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

BLUELINEA ,00 EUR composé de actions de valeur nominale 0,20 EUR Date de création : 17/01/2006

HUAWEI TECHNOLOGIES CO., LTD. channelroad. A better way. Together.

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

VTP. LAN Switching and Wireless Chapitre 4

Garage Door Monitor Model 829LM

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

StruxureWare Power Monitoring Expert v7.2

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

SYSTÈME JETS D AIR WISH WISH AIR JETS SYSTEM Système de massage à jets d air pour bains en polymère - Air jet massage system for polymer bathtubs

Stainless Steel Solar Wall Light

Tutoriel de formation SurveyMonkey

Information Equipment

User guide Conference phone Konftel 100

Transcription:

Powermax45 Power Switch Replacement Kit Kit de remplacement de l interrupteur d alimentation du Powermax45 Field Service Bulletin Bulletin de service sur le terrain 805880 Revision 3 March 2013 Révision 3 Mars 2013

Hypertherm, Inc. Etna Road, P.O. Box 5010 Hanover, NH 03755 USA 603-643-3441 Tel (Main Office) 603-643-5352 Fax (All Departments) info@hypertherm.com (Main Office Email) 800-643-9878 Tel (Technical Service) technical.service@hypertherm.com (Technical Service Email) 800-737-2978 Tel (Customer Service) customer.service@hypertherm.com (Customer Service Email) 866-643-7711 Tel (Return Materials Authorization) 877-371-2876 Fax (Return Materials Authorization) return.materials@hypertherm.com (RMA email) Hypertherm Plasmatechnik GmbH Technologiepark Hanau Rodenbacher Chaussee 6 D-63457 Hanau-Wolfgang, Deutschland 49 6181 58 2100 Tel 49 6181 58 2134 Fax 49 6181 58 2123 (Technical Service) Hypertherm (S) Pte Ltd. 82 Genting Lane Media Centre Annexe Block #A01-01 Singapore 349567, Republic of Singapore 65 6841 2489 Tel 65 6841 2490 Fax 65 6841 2489 (Technical Service) Hypertherm (Shanghai) Trading Co., Ltd. Unit 301, South Building 495 ShangZhong Road Shanghai, 200231 PR China 86-21-60740003 Tel 86-21-60740393 Fax Hypertherm Europe B.V. Vaartveld 9 4704 SE Roosendaal, Nederland 31 165 596907 Tel 31 165 596901 Fax 31 165 596908 Tel (Marketing) 31 165 596900 Tel (Technical Service) 00 800 4973 7843 Tel (Technical Service) Hypertherm Japan Ltd. Level 9, Edobori Center Building 2-1-1 Edobori, Nishi-ku Osaka 550-0002 Japan 81 6 6225 1183 Tel 81 6 6225 1184 Fax Hypertherm Brasil Ltda. Rua Bras Cubas, 231 Jardim Maia Guarulhos, SP - Brasil CEP 07115-030 55 11 2409 2636 Tel 55 11 2408 0462 Fax Hypertherm México, S.A. de C.V. Avenida Toluca No. 444, Anexo 1, Colonia Olivar de los Padres Delegación Álvaro Obregón México, D.F. C.P. 01780 52 55 5681 8109 Tel 52 55 5683 2127 Fax Hypertherm Korea Branch #3904 Centum Leaders Mark B/D, 1514 Woo-dong, Haeundae-gu, Busan Korea, 612-889 82 51 747 0358 Tel 82 51 701 0358 Fax 2013 Hypertherm, Inc. All rights reserved. Tous droits réservés. Powermax and Hypertherm are trademarks of Hypertherm, Inc. and may be registered in the United States and/or other countries. All other trademarks are the property of their respective holders. Hypertherm et Powermax sont des marques d Hypertherm, Inc. qui peuvent être déposées aux États-Unis et/ou dans d autres pays. Toutes les autres marques commerciales sont la propriété de leurs détenteurs respectifs.

Powermax45 Power Switch Replacement Kit DANGER! ELECTRIC SHOCK CAN KILL Disconnect electrical power before performing any maintenance. See the Safety and Compliance Manual for more safety precautions. Introduction Purpose This field service bulletin describes the steps necessary to replace the power switch in the Powermax45. Which kit you will need depends on the model of Powermax45 you have. Use kit number 228266 to replace the power switch on a 200 240 V CSA or 230V CE system. Use kit number 228288 to replace the power switch on a 400V CE or 480 V CSA system. Tools and materials needed #2 Phillips screwdriver 228266 Kit contents Part number Description Quantity 005619 Switch: 3P 240VAC 50A Rocker w/tc 1 075721 Machine Screw: M3 X 0.5 X 10-7 PH PAN 2SEM S/Z/TRI BLK 4 228288 Kit contents Part number Description Quantity 005618 Switch: 3P 600VAC 25A 1 075845 Plastite Screw: #8 X 5/8 PHILLIP FLAT BLK ZNC 4 Powermax45 Field Service Bulletin 805880 Revision 3 1

Powermax45 Power Switch Replacement Kit Replace the power switch (200 240 V CSA and 230 V CE) Before beginning this procedure, make sure you have the correct power switch for your system. The replacement kit number for a 200 240 V CSA or 230 V CE power switch is 228266. The procedure below applies to the 200 240 V CSA and the 230 V CE systems. The procedure for the 400 V CE and 480 V CSA systems follows on page 4. 1. Turn OFF the power, disconnect the power cord, and disconnect the gas supply. 2. Use a #2 Phillips screwdriver to remove the 2 screws from the handle on the top of the power supply. Tip the end panels back slightly so that you can get the edges of the handle out from underneath them. Lift the cover off the power supply. Remove the Mylar barrier that protects the power board. CAUTION! Static electricity can damage circuit boards. Use proper precautions when handling printed circuit boards. Store PC boards in anti-static containers. Wear a grounded wrist strap when handling PC boards. 3. Remove the 4 screws attaching the power switch to the power supply. Remove these 4 screws. 4. Gently tilt the rear end panel away from the power supply. 5. Remove the screw that secures the connector for the white (CSA) or blue (CE) power cord wire to the upper side of the power switch. 6. Remove the black (CSA) or brown (CE) power cord wire the same way. 7. Remove the quick disconnect (black wire). 8. Remove the power switch from the power supply by pulling it gently up and out to the side. 9. Remove the 2 screws that secure the black and white wires to the bottom of the power switch. 10. Remove the quick disconnect (red wire). 2 Powermax45 Field Service Bulletin 805880 Revision 3

Powermax45 Power Switch Replacement Kit 11. Install the new power switch in the reverse order of removal, making sure all wires are installed as shown below. Tighten the screws that were supplied with the kit (075721) to 8.1 kg cm (7 inch-pounds). Be sure the I on the switch is up and the O is down. Tighten the wire-mounting screws to 23.0 kg cm (20 in-lb). L Black wire (CSA) Brown wire (CE) Quick disconnect (black wire) Black White Quick disconnect (red wire) N White wire (CSA) Blue wire (CE) Power switch Powermax45 Field Service Bulletin 805880 Revision 3 3

Powermax45 Power Switch Replacement Kit Replace the power switch (400 V CE and 480 V CSA) Before beginning this procedure, make sure you have the correct power switch for your system. The replacement kit number for a 400 V CE or 480 V CSA power switch is 228288. The procedure below applies to the 400 V CE and 480 V CSA systems. 1. Turn OFF the power, disconnect the power cord, and disconnect the gas supply. 2. Use a #2 Phillips screwdriver to remove the 2 screws from the handle on the top of the power supply. Tip the end panels back slightly so that you can get the edges of the handle out from underneath them. Lift the cover off the power supply. Remove the Mylar barrier that protects the power board. CAUTION! Static electricity can damage circuit boards. Use proper precautions when handling printed circuit boards. Store PC boards in anti-static containers. Wear a grounded wrist strap when handling PC boards. 3. Remove the screw holding the rotary switch, then remove the rotary switch and inner plastic grommet. Remove the 4 screws attaching the power switch to the power supply. Remove these 4 screws. Remove the rotary switch screw. I O 4. Gently tilt the rear end panel away from the power supply. 5. Remove the power switch from the power supply by pulling it gently up and out to the side. 6. Loosen the 3 screws that secure the power cord wires to the power switch and gently pull the wires out of the switch. The wires for 400 V CE power cords are brown, black, and gray. The wires for 480 V CSA power cords are black, white, and red. 7. Loosen the 3 screws that secure the 3 white wires to the power switch and gently pull the wires out of the switch. 8. Install the new power switch in the reverse order of removal. Tighten the screws that were supplied with the kit (075845) to 11.5 kg cm (10 inch-pounds). 4 Powermax45 Field Service Bulletin 805880 Revision 3

Powermax45 Power Switch Replacement Kit Note: Be sure to install the wires correctly, for example L1 wire to L1 switch. Tighten the wire-mounting screws to 23.0 kg cm (20 in-lb). Brown (CE) or Black (CSA) L1 Black (CE) or White (CSA) L2 Gray (CE) or Red (CSA) L3 Power switch White (T3) White (T2) White (T1) Powermax45 Field Service Bulletin 805880 Revision 3 5

Powermax45 Power Switch Replacement Kit 6 Powermax45 Field Service Bulletin 805880 Revision 3

Kit de remplacement de l interrupteur d alimentation du Powermax45 DANGER! UN CHOC ÉLECTRIQUE PEUT ÊTRE MORTEL Avant tout entretien, débrancher l alimentation électrique. Se reporter au Manuel de sécurité et de conformité pour des mesures de sécurité supplémentaires. Introduction Objet Ce bulletin de service sur le terrain décrit les étapes nécessaires pour le remplacement de l interrupteur d alimentation du Powermax45. Le kit dont vous avez besoin dépend du modèle Powermax45 que vous possédez. Utiliser le kit numéro 228266 pour remplacer l interrupteur d alimentation d un système 200 240 V CSA ou 230 V CE. Utiliser le kit numéro 228288 pour remplacer l interrupteur d alimentation d un système 400 V CE ou 480 V CSA. Outils et matériel requis Tournevis cruciforme n 2 Contenu du kit 228266 Numéro de référence Description Quantité 005619 Interrupteur : 3P 240 V c.a. 50 A, à bascule, avec TC 1 075721 Vis mécanique : M3 X 0,5 X 10 7 PH 2SEM S/Z/TRI à tête cylindrique, noire 4 Contenu du kit 228288 Numéro de référence Description Quantité 005618 Interrupteur : 3P 600 V c.a. 25 A 1 075845 Vis Plastite : n 8 x 5/8 CRUCIFORME PLATE NOIRE ZINC 4 Powermax45 Bulletin de service sur le terrain 805880 Révision 3 a-1

Kit de remplacement de l interrupteur d alimentation du Powermax45 Remplacement de l interrupteur d alimentation (200 240 V CSA et 230 V CE) Avant de commencer cette procédure, vérifier que l interrupteur d alimentation est bien adapté à votre système. Le numéro du kit de remplacement pour l interrupteur d alimentation 200 240 V CSA ou 230 V est 228266. La procédure ci-dessous s applique aux systèmes 200 240 V CSA et 230 V CE. La procédure pour les systèmes 400 V CE et 480 V CSA suit à la page 4. 1. Couper l alimentation (OFF), débrancher le cordon d alimentation et débrancher l alimentation en gaz. 2. Utiliser un tournevis cruciforme n 2 pour enlever les deux vis de la poignée située sur le dessus de la source de courant. Basculer légèrement les panneaux d extrémité de façon à en extraire les bords de la poignée d en dessous. Retirer le couvercle de la source de courant en le levant. Déposer la barrière Mylar qui protège le circuit imprimé d alimentation. ATTENTION! L électricité statique peut endommager les cartes de circuits imprimés. Les précautions qui s imposent doivent être respectées lors de la manipulation des cartes de circuits imprimés. Les cartes de circuits imprimés doivent être rangées dans des contenants antistatiques. L utilisateur doit porter un bracelet antistatique lors de la manipulation des cartes de circuits imprimés. 3. Retirer les 4 vis fixant l interrupteur d alimentation à la source de courant. Retirer ces quatre vis. 4. Éloigner délicatement le panneau d extrémité arrière de la source de courant. 5. Déposer la vis fixant le câble blanc (CSA) ou bleu (CE) du cordon d alimentation au connecteur sur la partie supérieure de l interrupteur d alimentation. 6. Retirer le câble noir (CSA) ou marron (CE) du cordon d alimentation de la même manière. 7. Retirer le raccord rapide (fil noir). 8. Retirer l interrupteur d alimentation de la source de courant en le tirant délicatement vers le haut et sur le côté. 9. Retirer les deux vis qui fixent les fils noir et blanc au bas de l interrupteur d alimentation. 10. Retirer le raccord rapide (fil rouge). a-2 Powermax45 Bulletin de service sur le terrain 805880 Révision 3

Kit de remplacement de l interrupteur d alimentation du Powermax45 11. Installer le nouvel interrupteur d alimentation dans l ordre inverse du retrait, en s assurant que tous les fils sont fixés contre le montre la figure ci-dessous. Serrer les vis fournies avec le kit (075721) avec un couple de 8,1 kg cm. S assurer que le «I» de l interrupteur est en haut, et le «O» en bas. Serrer les vis de fixation des fils à un couple de 23,0 kg cm. Fil noir (CSA) Fil marron (CE) Raccord rapide (fil noir) N Fil blanc (CSA) Fil bleu (CE) Noir Blanc Raccord rapide (fil rouge) Interrupteur d alimentation Powermax45 Bulletin de service sur le terrain 805880 Révision 3 a-3

Kit de remplacement de l interrupteur d alimentation du Powermax45 Remplacement de l interrupteur d alimentation (400 V CE et 480 V CSA) Avant de commencer cette procédure, vérifier que l interrupteur d alimentation est bien adapté à votre système. Le numéro du kit de remplacement pour l interrupteur d alimentation 400 V CE ou 480 V CSA est 228288. La procédure ci-dessous s applique aux systèmes 400 V CE et 480 V CSA. 1. Couper l alimentation (OFF), débrancher le cordon d alimentation et débrancher l alimentation en gaz. 2. Utiliser un tournevis cruciforme n 2 pour enlever les deux vis de la poignée située sur le dessus de la source de courant. Basculer légèrement les panneaux d extrémité de façon à en extraire les bords de la poignée d en dessous. Retirer le couvercle de la source de courant en le levant. Déposer la barrière Mylar qui protège le circuit imprimé d alimentation. ATTENTION! L électricité statique peut endommager les cartes de circuits imprimés. Les précautions qui s imposent doivent être respectées lors de la manipulation des cartes de circuits imprimés. Les cartes de circuits imprimés doivent être rangées dans des contenants antistatiques. L utilisateur doit porter un bracelet antistatique lors de la manipulation des cartes de circuits imprimés. 3. Retirer la vis qui maintient l interrupteur rotatif, puis retirer ce dernier, ainsi que l œillet intérieur en plastique. Déposer les quatre vis fixant l interrupteur d alimentation à la source de courant. Retirer ces quatre vis. Retirer la vis de l interrupteur rotatif. I O 4. Éloigner délicatement le panneau d extrémité arrière de la source de courant. 5. Retirer l interrupteur d alimentation de la source de courant en le tirant délicatement vers le haut et sur le côté. 6. Desserrer les trois vis fixant les fils du cordon d alimentation à l interrupteur d alimentation, puis tirer doucement les fils hors de l interrupteur. Les fils pour les cordons d alimentation 400 V CE sont marron, noir et gris. Les fils pour les cordons d alimentation 480 V CSA sont noir, blanc et rouge. 7. Desserrer les trois vis qui fixent les trois fils blancs à l interrupteur d alimentation, puis tirer doucement les fils hors de l interrupteur. 8. Installer le nouvel interrupteur d alimentation dans l ordre inverse de son démontage. Serrer les vis fournies avec le kit (075845) à un couple de 11,5 kg cm. a-4 Powermax45 Bulletin de service sur le terrain 805880 Révision 3

Kit de remplacement de l interrupteur d alimentation du Powermax45 Note : S assurer de fixer les fils correctement, par exemple le fil L1 sur le connecteur L1 de l interrupteur. Serrer les vis de fixation des fils à un couple de 23,0 kg cm. Marron (CE) ou noir (CSA) L1 Noir (CE) ou blanc (CSA) L2 Gris (CE) ou rouge (CSA) L3 Interrupteur d alimentation Blanc (T3) Blanc (T2) Blanc (T1) Powermax45 Bulletin de service sur le terrain 805880 Révision 3 a-5

Kit de remplacement de l interrupteur d alimentation du Powermax45 a-6 Powermax45 Bulletin de service sur le terrain 805880 Révision 3