Installation instructions RICON S 140/60 VS

Documents pareils
FRIULSIDER Via Trieste,1 I San Giovanni al Natisone (UDINE) ITALIE

Vis à béton FBS et FSS

SERRURES EXTRA-PLATES

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

Contrôle et Monitoring

Fabricant. 2 terminals

Table des matières QUINCAILLERIE FONCTIONNEL FUNCTIONAL HARDWARE. Clé H1 Serrure et pêne H2. Serrure à levier H4

Embases pour raccordement G1/8 - G1/4

Stérilisation / Sterilization

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Folio Case User s Guide

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN 61303:1997

Fédération Internationale de Handball. b) Règlement du but

Technique Opératoire. Plaque Fyxis P l aq u e P o u r Arthrodèse MTP du Pre m i e r R ayo n

R.V. Table Mounting Instructions

EQUIPEMENT DU BASSIN / COMMERCIAL POOL ACCESSORIES

ALUMINA CONÇUE POUR PRÉSENTER SANS ÊTRE VUE.

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

Logitech Speaker System Z553 Setup Guide Guide d installation

Et6. Octobre Armatures Manchonnées en Attente Pour l Industrie de la Construction

Guide d installation Deco Drain inc. DD200

GASKET FOR TONER COLLECTION BOTTLE

Optimisez la gestion de vos projets IT avec PPM dans le cadre d une réorganisation. SAP Forum, May 29, 2013

Notice Technique / Technical Manual

Monitor LRD. Table des matières

86 rue Julie, Ormstown, Quebec J0S 1K0

L. Obert, T. Lascar, A. Adam

Microsoft Lync de votre bureau à la salle de conférence

AMC 120 Amplificateur casque

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Vous venez d acquérir un produit de la marque Essentiel b et nous vous en remercions. Nous apportons un soin tout particulier au design, à la

Quick start guide. HTL1170B

Contents Windows

PRINCIPES ET APPLICATIONS

Université de XY University of XY. Faculté XY Faculty of XY

La soudure à l arc. électrique. Jean-Claude Guichard. Groupe Eyrolles, 2006, ISBN :

MANUEL D INSTRUCTIONS. Débitmètres massique et Régulateurs de débit massique MASS-STREAM TM D-6300

Recommandations pour attelages (crochets, anneaux et têtes de flèches)

Le No.1 de l économie d énergie pour patinoires.

SERVEUR DÉDIÉ DOCUMENTATION

L'Offre sera ouverte pendant 18 jours de bourse, à un prix par action de 152,30 EUR. BPCE International et Outre-Mer

CONTEC CO., LTD. Novembre 2010

Installer le patch P-2746 et configurer le Firewall avancé

Introduction. Si dans le kit un produit vous semble endommagé ou non conforme, veuillez faire une photo et nous l envoyer par mail pour vérification.

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

5Visualisation. pièges à. éviter... de données : e-book : Visualisation & Ergonomie. Page 1 / 30. Partagez cet e-book :

PACKZ System Requirements. Version: Version: Copyright 2015, PACKZ Software GmbH. 1

Sommaire Table des matières

ROTOLINE NOTICE DE POSE

Fiche technique Ligne de vie SECURIFIL industrie

Conférence Bales II - Mauritanie. Patrick Le Nôtre. Directeur de la Stratégie - Secteur Finance Solutions risques et Réglementations

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

CATALOGUE DE PRESTATIONS D ACCOMPAGNEMENT METIER DES CENTRES DE CONTACTS

22/09/2014 sur la base de 55,03 euros par action

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Table basse avec tablette encastrée

EVÈNEMENT MOBILITÉ HYDROGÈNE À NANTES PRÉSENTATION DU VÉHICULE KANGOO H2 PAR SYMBIO FCELL

Carport Evolution 1 Voiture Adossant

Sécurité relative aux sièges auto et aux rehausseurs

Contrôle d'accès Access control. Notice technique / Technical Manual

ANDRITZ Atro Vis hydrodynamique

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

SCELLEMENT CHIMIQUE / CHEMICAL MORTAR

Gestion des prestations Volontaire

JABRA DRIVE MANUEL DE L UTILISATEUR

OLP-55 Smart Optical Power Meter Un mesureur de puissance optique évolutif de la gamme Smart

ACS-30-EU-PCM2-x-32A Régulation et surveillance du traçage électrique des bâtiments commerciaux et résidentiels pour divers domaines d application

DRIVE-TECHNOLOGY INKOMA - GROUP. Actionneur pour panneaux solaires - ASN ALBERT

Manuel de montage et d emploi Serrure électrique E 205

La vis pro. Qualité du PROducteur! designed by SWG Germany SWG HSW I ETA-12/0373

Chauffe-eau électrique Chaffoteaux

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Jean-Marc Schaffner Ateliers SCHAFFNER. Laure Delaporte ConstruirAcier. Jérémy Trouart Union des Métalliers

Guide pratique de CSPM, l'outil de suivi des performances du système Version française du Complete System Performance Monitor HOWTO

BATTERIES DE SECOURS POUR CENTRAL D ALARME ET DE MESURE BAT KIT NOTICE D INSTALLATION. BATKIT_MAN01_FR Ver. V1R1

Le Tour de Bretagne à la Voile est une épreuve de catégorie 3 des RSO. En cas de traduction de cet avis de course, le texte français prévaudra

Nouvelle version de Zonecheck, la 3.0, avec tests DNSSEC

Guide d'installation rapide TFM-560X YO.13


Unitecnic 2210 Unitecnic 2210 CS

Dexia Guide d installation de NetWorker Server 25 juin Legato Systems, Inc.

Synoptique. Instructions de service et de montage

Contrôleurs de Débit SIKA

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

A. CARACTERISTIQUES TECHNIQUES.

TUBES ET ACCESSOIRES Serrurier A ailettes Construction Canalisation Spéciaux

Qualité. Quality. Service. Service. Innovation. Innovation produits en inventaire products in stock

2/ Configurer la serrure :

VANNES À PASSAGE DIRECT GATE VALVES

Information Equipment

IPSAS 32 «Service concession arrangements» (SCA) Marie-Pierre Cordier Baudouin Griton, IPSAS Board

CAA/SE N O T I C E D E M O N T A G E E T D U T I L I S A T I O N KIT DE MONTAGE. Clavier lumineux codes DIGICODE

Micro contact à bascule 28

Instructions Mozilla Thunderbird Page 1

Vannes 3 voies avec filetage extérieur, PN 16

Z-Axis Compliance Device Compliance en z

JKW-IP. Mettez votre intercom vidéo en ligne.

AUTOPORTE III Notice de pose

Installation d un patch de mise à jour et d un pack langue dans SugarCRM Open Source 4.5.1

Transcription:

Art.No. K126 1. Routing in main beam Installation instructions 140/ VS Welded collar bolt Routing in main beam 2. Pre drilling centered installation of Secondary beam Main beam ETA10/0189 R 7, 5 Length L 45 Height HN Length L 2 x drillings Ø 5, depth 50 mm 2 x drillings Ø 5, depth 50 mm 3. Screwing: 1. Positioning of using predrilled holes for 2 screws. Drive in screws in secondary beam 7 or 10 CS 8x1 This drawing is the exclusive property of Knapp GmbH. 2. Mount with CSscrews according to the drawing right hand Information: Min. Screwing 7 pcs. > 24kN green mark Max. Screwing 10 pcs. > 36 kn additional Screws red mark Drive in screws in main beam 20 20 7 or 10 CS 8x80 Knapp GmbH. All measures in mm Errors excepted. VERSION 01 06. 02. 2014 Page 1/4

Art.No. K126 Installation instructions 140/ VS Welded collar bolt Routing in main beam ETA10/0189 Routing length in main beam with respect to secondary beam member height H N Secondary beam height H N 1 0 2 3 140x Length L without perpendicular to grain tension reinforcement 155 170 210 Predrill distance t 1 in main and secondary beam with respect to secondary beam member height H N Secondary beam height H N RICON S 140x Predrill distance t 1 for secondary beam This drawing is the exclusive property of Knapp GmbH. Distance t 1 55 70 1 0 2 3 Important information: Please contact a licensed design professional for the design of any connection not listed in the tables. Full thread screws may be used to reinforce potential splitting perpendicular to grain or transverse shear failure. 80 110 header full thread screw with self tapping tip joist Knapp GmbH. All measures in mm Errors excepted. VERSION 01 06. 02. 2014 Page 2/4

Art.No. K126 1. Routing in secondary beam Installation instructions 140/ VS Welded collar bolt Alternative: Routing in secondary beam 2. Pre drilling centered installation of Secondary beam Main beam Post ETA10/0189 40 +40 Height HN Height HN 20 20 2 x drillings Ø 5, depth 50 mm 2 x drillings Ø 5, depth 50 mm This drawing is the exclusive property of Knapp GmbH. 3. Screwing: 1. Positioning of using predrilled holes for 2 screws. 2. Mount with CSscrews according to the drawing right hand Information: Min. Screwing 7 pcs. > 24kN green mark Max. Screwing 10 pcs. > 36 kn additional Screws red mark Drive in screws in secondary beam Drive in screws in main beam or 7 or 10 CS 8x1 7 or 10 CS 8x80 post 40 20 Knapp GmbH. All measures in mm Errors excepted. VERSION 01 06. 02. 2014 Page 3/4

Art.No. K126 Installation instructions 140/ VS Welded collar bolt Alternative: Routing in secondary beam ETA10/0189 full thread screw with self tapping tip HN 2 1 This drawing is the exclusive property of Knapp GmbH. Secondary beam height H N 0 2 340 3 Edge distance t 1 with respect to secondary beam member height H N 140x Distance t 1 10 20 30 Important Information: Please contact a licensed design professional for the design of any connection not listed in the tables. Full thread screws may be used to reinforce potential splitting perpendicular to grain or transverse shear failure. Knapp GmbH. All measures in mm Errors excepted. VERSION 01 06. 02. 2014 Page 4/4

Réf. K126 1. Fraiser la poutre principale 2. Percer Poutre secondaire Notice de montage 140/ VS Pièce d'accroche soudée Encastrement sur la poutre principale Poutre principale ETA10/0189 Longueur L Hauteur HN Longueur L R 7, 5 45 Ce dessin est la propriété de Knapp GmbH. 3. Visser 1. Visser la ferrure sur les autres perçages de position 2. Visser le reste des vis suivant le schéma (cf. dessins à droite) Information 7 vis = min. > 24 kn marquages vert 10 vis = max. > 36 kn marquages rouge (4 vis supplémentaires) 2 perçages de position Ø 5 mm sur bois de bout, profondeur 50 mm Fixation sur la poutre principale 2 perçages de position Ø 5 mm sur bois de fil, profondeur 50 mm Fixation sur la poutre secondaire 7 ou 10 vis SK 8x1 20 20 7 ou 10vis SK 8x80 Knapp GmbH. Toutes dimensions en mm sauf erreurs, fautes d'impression ou modifications techniques. VERSION 06. 02. 2014 Page 1/4

Réf. K126 Longueur de fraisage L sur la poutre principale Notice de montage 140/ VS Pièce d'accroche soudée Encastrement sur la poutre principale Longueur de fraisage L sur la poutre principale sans vissage de renfort traversant, en relation avec ETA10/0189 Ce dessin est la propriété de Knapp GmbH. la hauteur de poutre secondaire H N Hauteur de poutre secondaire H N 1 0 2 3 Hauteur de poutre secondaire H N 1 0 2 3 140x Longueur L sans renfort 155 170 210 Position des perçages sur la poutre principale et secondaire Position de perçages t 1 sur la poutre principale et secondaire en relation avec la hauteur de poutre secondaire H N RICON S 140x Position de perçage t 1 sur la poutre secondaire Distance t 1 55 70 80 110 Remarque importante: Faire contrôler par un B.E. compétant dans le cas où la hauteur de la poutre secondaire et plus faible qu'indiqué cidessus. Une section plus faible peut être renforcée par des vis de renfort traversantes (EN 199511, NAD et DIN 1052,11.4.3)! Poutre principale Vis à filetage total avec pointe autoforeuse Pour le renfort tranchant des poutres secondaires Poutre secondaire Knapp GmbH. Toutes dimensions en mm sauf erreurs, fautes d'impression ou modifications techniques. VERSION 06. 02. 2014 Page 2/4

Réf. K126 1. Fraiser la poutre secondaire 2. Percer Poutre secondaire Notice de montage 140/ VS Pièce d'accroche soudée Variante: Encastrement sur la poutre secondaire Poutre principale Poteau ETA10/0189 40 +40 Hauteur HN Hauteur HN 20 20 2 perçages de position Ø 5 mm sur bois de bout, profondeur 50 mm 2 perçages de position Ø 5 mm sur bois de fil, profondeur 50 mm Ce dessin est la propriété de Knapp GmbH. 3. Visser 1. Visser la ferrure sur les autres perçages de position 2. Visser le reste des vis suivant le schéma (cf. dessins à droite) Information 7 vis = min. > 24 kn marquages vert 10 vis = max. > 36 kn marquages rouge (4 vis supplémentaires) Fixation sur la poutre secondaire Fixation sur la poutre principale ou le poteau 7 ou 10 vis SK 8x80 7 ou 10 vis SK 8x1 40 20 7 ou 10 vis SK 8x80 Knapp GmbH. Toutes dimensions en mm sauf erreurs, fautes d'impression ou modifications techniques. VERSION 06. 02. 2014 Page 3/4

Réf. K126 Notice de montage 140/ VS Pièce d'accroche soudée Variante: Encastrement sur la poutre secondaire ETA10/0189 Vis à filetage total avec pointe autoforeuse Pour le renfort tranchant des poutres secondaires HN 2 1 Ce dessin est la propriété de Knapp GmbH. Distance du bord en relation avec la hauteur de la poutre secondaire HN et de la taille de Hauteur de poutre secondaire H N 0 2 340 3 Distance du bord t 1 en relation avec la hauteur de la poutre secondaire H N 140x Distance t 1 10 20 30 Remarque importante: Faire contrôler par un B.E. compétant dans le cas où la hauteur de la poutre secondaire et plus faible qu'indiqué cidessus. Une section plus faible peut être renforcée par des vis de renfort traversantes (EN 199511, NAD et DIN 1052,11.4.3)! Knapp GmbH. Toutes dimensions en mm sauf erreurs, fautes d'impression ou modifications techniques. VERSION 06. 02. 2014 Page 4/4