Powermax45 Quick Disconnect Replacement (Power Supply) Powermax45 - Remplacement du raccord rapide (source de courant)

Documents pareils
GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Folio Case User s Guide

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Lavatory Faucet. Instruction Manual. Questions?

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

R.V. Table Mounting Instructions

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Package Contents. System Requirements. Before You Begin

Logitech Speaker System Z553 Setup Guide Guide d installation

Instructions Mozilla Thunderbird Page 1

Le No.1 de l économie d énergie pour patinoires.

Contents Windows

Notice Technique / Technical Manual

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

PAR_ _09543_EUR DATE: 17/12/2014. Suite à l'avis PAR_ _08654_EUR

Monitor LRD. Table des matières

CAUTION CATALOGUE DE PIÈCES ILLUSTRÉ BUNN-O-MATIC CORPORATION OF CANADA LTD.

SYSTÈME DE GAINES À SPIRALE ET RACCORDS TOURNANTS

Contrôle d'accès Access control. Notice technique / Technical Manual

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Quick start guide. HTL1170B

GASKET FOR TONER COLLECTION BOTTLE

Table des matières QUINCAILLERIE FONCTIONNEL FUNCTIONAL HARDWARE. Clé H1 Serrure et pêne H2. Serrure à levier H4

Garage Door Monitor Model 829LM

Paxton. ins Net2 desktop reader USB

Sécurité relative aux sièges auto et aux rehausseurs

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices


SERVEUR DÉDIÉ DOCUMENTATION

ENGLISH 4 FRANÇAIS 6 ESPAÑOL 8

Sun StorageTek 2500 Series

ADMINISTRATION DE ADOBE LIVECYCLE MOSAIC 9.5

Now enhanced with powerful workplace solutions Maintenant amélioré, diet+ vous offre de puissantes solutions novatrices pour le milieu de travail

POLICY: FREE MILK PROGRAM CODE: CS-4

Start Here Point de départ

Guide de récupération de Windows Server 2003 R2 pour serveurs Sun x64

Stérilisation / Sterilization

WEB page builder and server for SCADA applications usable from a WEB navigator

en SCÈNE RATIONAL Rational Démonstration SDP : automatisation de la chaîne de développement Samira BATAOUCHE sbataouche@fr.ibm.com

Start Here Point de départ Epson Stylus

22/09/2014 sur la base de 55,03 euros par action

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

INSTITUT MARITIME DE PREVENTION. For improvement in health and security at work. Created in 1992 Under the aegis of State and the ENIM

Fabricant. 2 terminals

Guide de démarrage du système modulaire Sun Blade 6000

BLUELINEA ,00 EUR composé de actions de valeur nominale 0,20 EUR Date de création : 17/01/2006

GAME CONTENTS CONTENU DU JEU OBJECT OF THE GAME BUT DU JEU

HUAWEI TECHNOLOGIES CO., LTD. channelroad. A better way. Together.

Cedric Dumoulin (C) The Java EE 7 Tutorial

Exercices sur SQL server 2000

Tom Pertsekos. Sécurité applicative Web : gare aux fraudes et aux pirates!

Stainless Steel Solar Wall Light

FÉDÉRATION INTERNATIONALE DE NATATION Diving

Installation Guide. Ceramic Oval Handle Trim Kit

lundi 3 août 2009 Choose your language What is Document Connection for Mac? Communautés Numériques L informatique à la portée du Grand Public

PACKZ System Requirements. Version: Version: Copyright 2015, PACKZ Software GmbH. 1

Archived Content. Contenu archivé

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

Procédures de conversion de gaz Modèles des séries VCS3008, VCS4008, VCS5008

Editing and managing Systems engineering processes at Snecma

SparkInData. Place de Marché des applications Spatiales

NEW Fin Fan / Air cooled condenser cleaning

ERserver. Instructions relatives à l installation du cordon d alimentation double 5094, 5294 et iseries. Version 5

THE LAW SOCIETY OF UPPER CANADA BY-LAW 19 [HANDLING OF MONEY AND OTHER PROPERTY] MOTION TO BE MOVED AT THE MEETING OF CONVOCATION ON JANUARY 24, 2002

DOCUMENTATION - FRANCAIS... 2

SAP Runs SAP Reporting Opérationnel & BI avec HANA et SAP Analytics. Pierre Combe, Enterprise Analytics Juin, 2015

Credit Note and Debit Note Information (GST/ HST) Regulations

Optimisez la gestion de vos projets IT avec PPM dans le cadre d une réorganisation. SAP Forum, May 29, 2013

AUDIT COMMITTEE: TERMS OF REFERENCE

The impacts of m-payment on financial services Novembre 2011

SERIE TS-770 SYSTEME CONFERENCE

Panneau d alimentation de Store Cellulaire

Z-Axis Compliance Device Compliance en z

Wobe.

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN 61303:1997

Spécial Catégorie 6 Patch Cords


Coffrets de table Accessoires

PARIS ROISSY CHARLES DE GAULLE

Logitech Wireless Performance Combo MX800 Setup Guide Guide d installation

Multiple issuers. La cotation des actions ROBECO ci-dessous est suspendue sur EURONEXT PARIS dans les conditions suivantes :

Exemple PLS avec SAS

STATUS VIS-Av -VIS THE HOST STATE OF A DIPLOMATIC ENVOY TO THE UNITED NATIONS (COMMONWEALTH OF DOMINICA v. SWITZERLAND)

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

CONTEC CO., LTD. Novembre 2010

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

86 rue Julie, Ormstown, Quebec J0S 1K0

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

PHANTOM. Manuel Avancé. V Révision DJI Innovations. All Rights Reserved. 1

Utiliser un proxy sous linux

PRESENTATION REMOTE TÉLÉCOMMANDE DE PRÉSENTATION. User Guide Manuel de l utilisateur

Information Equipment

MONTEGO 3 PERSON CUSHION GARDEN SWING WITH CANOPY ASSEMBLY INSTRUCTIONS ITEM# SC-177-2GS

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

Transcription:

Powermax45 Quick Disconnect Replacement (Power Supply) Powermax45 - Remplacement du raccord rapide (source de courant) Field Service Bulletin Bulletin de service sur le terrain 805910 Revision 0 December, 2008 Révision 0 Décembre, 2008

POWERMAX45 QUICK DISCONNECT REPLACEMENT (POWER SUPPLY) DANGER ELECTRIC SHOCK CAN KILL Disconnect electrical power before performing any maintenance. See Section 1 of the Operator Manual for more safety precautions. Introduction Purpose This field service bulletin describes the steps necessary to replace the Quick Disconnect on the Powermax45 power supply. Tools and materials needed #2 Phillips screwdriver 1/2 (or adjustable) wrench Flat-blade screwdriver 228282 Kit contents Part number Description Quantity 075646 Locknut: 5/16-24 Nylon locking insert 1 075693 Plastite Screw: #6 X 1/2 4 104370 Fitting: Quick-disconnect torch gas/power receptacle 1 229175 Receptacle Subassembly: PMX45 Power Supply Quick Disc. 1 Field Service Bulletin 1

POWERMAX45 QUICK DISCONNECT REPLACEMENT (POWER SUPPLY) Remove the quick disconnect (power supply) 1. Turn OFF the power, disconnect the power cord, and disconnect the gas supply. 2. Remove the 2 screws from the handle on the top of the power supply. Remove the handle and then lift the cover off the power supply. Remove the Nomex barrier that protects the power board.] Caution: Static electricity can damage circuit boards. Use proper precautions when handling printed circuit boards. Store PC boards in anti-static containers. Wear a grounded wrist strap when handling PC boards. 3. Detach the front panel by unscrewing the two screws that attach it to the power supply (one screw at the top and one screw underneath the power supply). 4. Detach the gas line connector. Use a flat-blade screwdriver to push the orange connector cap away from the nut. 5. Remove the nut and discard it. 6. Slide the black transformer wire connector off of the brass fitting. 7. Slide the brass fitting out through the front panel. Discard the brass fitting. Wire routing grommet (upper) Front panel screw Black transformer wire connector Brass fitting (hidden) Gas line connector Nut Front panel screw 2 Field Service Bulletin

POWERMAX45 QUICK DISCONNECT REPLACEMENT (POWER SUPPLY) 8. Disconnect the J10 wire connector (Orange/White/Blue/Violet/Yellow wires) from the power board and slide it through the wire routing grommet (upper). 9. Unscrew the J17 wire connector (Red) from the power board and slide it through the wire routing grommet (lower) and through the protective fiberglass sleeving. 10. Remove the 4 screws that attach the quick disconnect receptacle to the front panel and remove the quick disconnect receptacle. Discard the quick disconnect receptacle. 11. Install the new quick disconnect receptacle and all removed parts in the reverse order of removal, using the new brass fitting and nut that came with the kit. NOTE: Torque the nut to a value of 40 in-lbs. J10 connector (hidden) J17 connector TP 19 W 192 VDC TP 18 R 192 VDC + - + - TP 17 B Wire routing grommet (lower) Field Service Bulletin 3

POWERMAX45 QUICK DISCONNECT REPLACEMENT (POWER SUPPLY) 4 Field Service Bulletin

POWERMAX45 - REMPLACEMENT DU RACCORD RAPIDE (SOURCE DE COURANT) DANGER UN CHOC ÉLECTRIQUE PEUT ÊTRE MORTEL Toujours couper l alimentation électrique avant de procéder à toute opération d entretien. Voir la Section 1 du Manuel de l opérateur où l on donne davantage de mesures de sécurité. Introduction Objet Ce bulletin de service sur le terrain décrit les étapes nécessaires pour remplacer le raccord rapide sur la source de courant Powermax45. Outils et matériaux nécessaires Tournevis Phillips N o 2 Clé 1/2 po (ou clé à molette) Tournevis à pointe plate Nécessaire 228282 Numéro de référence Description Quantité 075646 Écrou de blocage : Insert de blocage en nylon 5/16-24 1 075693 Vis Plastite : N o 6 x 1/2 4 104370 Raccord : Raccord rapide prise gaz/alimentation torche 1 229175 Sous-ensemble prise : Raccord rapide de la source de courant PMX45. 1 Bulletin de service sur le terrain a-1

POWERMAX45 - REMPLACEMENT DU RACCORD RAPIDE (SOURCE DE COURANT) Déposer le raccord rapide (source de courant) 1. Couper l alimentation (OFF), débrancher le cordon d alimentation et débrancher le gaz d alimentation. 2. Desserrer les 2 vis de la poignée à la partie supérieure de la source de courant. Déposer la poignée puis soulever le capot pour le sortir de la source de courant. Déposer la barrière Nomex qui protège le CI d alimentation. Attention : L électricité statique peut endommager les circuits imprimés. Prendre les précautions qui s appliquent quand on manipule des circuits imprimés. Entreposer les circuits imprimés dans des contenants antistatiques. Porter un bracelet antistatique quand on manipule des CI de commande. 3. Détacher le panneau avant en desserrant les deux vis qui le fixent à la source de courant (une vis sur le dessus et une vis au-dessous de la source de courant). 4. Détacher le connecteur de la conduite de gaz. Utiliser un tournevis à pointe plate pour écarter le capuchon du connecteur orange de l écrou. 5. Enlever l écrou et le mettre au rebut. 6. Faire glisser le connecteur du fil noir du transformateur pour le sortir du raccord en laiton. 7. Faire glisser le raccord en laiton par le panneau avant. Mettre le raccord en laiton au rebut. Passe-fil (supérieur) Vis du panneau avant Connecteur du fil noir du transformateur Raccord en laiton (caché) Connecteur de la conduite de gaz Écrou Vis du panneau avant a-2 Bulletin de service sur le terrain

POWERMAX45 - REMPLACEMENT DU RACCORD RAPIDE (SOURCE DE COURANT) 8. Déconnecter le connecteur des fils de J10 (fils orange/blanc/bleu/violet/jaune) du CI d alimentation et le faire glisser dans le passe-fil (supérieur). 9. Dévisser le connecteur du fil J17 (rouge) du CI d alimentation et le faire glisser dans le passe-fil (inférieur) et dans la gaine de protection en fibre de verre. 10. Dévisser les 4 vis qui fixent la prise du raccord rapide au panneau avant et enlever la prise du raccord rapide. Mettre au rebut la prise du raccord rapide. 11. Monter une prise de raccord rapide neuve et toutes les pièces déposées dans l ordre inverse de dépose en utilisant un raccord en laiton neuf et la vis fournie dans le kit. NOTE : Serrer l écrou à 40 po-lb. Connecteur J10 (caché) Connecteur J17 TP 19 W 192 VDC TP 18 R 192 VDC + - + - TP 17 B Passe-fil (inférieur) Bulletin de service sur le terrain a-3

POWERMAX45 - REMPLACEMENT DU RACCORD RAPIDE (SOURCE DE COURANT) a-4 Bulletin de service sur le terrain

2008 Hypertherm, Inc. All Rights Reserved Tous droits réservés Hypertherm and Powermax are trademarks of Hypertherm, Inc. and may be registered in the United States and/or other countries. Hypertherm et Powermax sont des marque de commerce d Hypertherm, Inc. et peut être déposée aux États-Unis et/ou dans d autres pays. Hypertherm, Inc. Hanover, NH 03755 USA 603-643-3441 Tel Hypertherm (S) Pte Ltd. 417847, Republic of Singapore 65 6 841 2489 Tel Hypertherm (Shanghai) Trading Co., Ltd. PR China 200052 86-21 5258 3330 /1 Tel Hypertherm Europe B.V. 4704 SE Roosendaal, Nederland 31 165 596907 Tel HYPERTHERM BRASIL LTDA. Guarulhos, SP - Brasil 55 11 2409 2636 Tel www.hypertherm.com