FO-V3 Rectangular Gravity Vent Kit

Documents pareils
Lavatory Faucet. Instruction Manual. Questions?

Folio Case User s Guide

Instructions Mozilla Thunderbird Page 1

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Sécurité relative aux sièges auto et aux rehausseurs

Guide d'installation rapide TFM-560X YO.13

FO-FDHB6-1 Central Heat Blower Kit for Onyx, Opel and Delta

DOCUMENTATION - FRANCAIS... 2

R.V. Table Mounting Instructions

Guide d installation Deco Drain inc. DD200

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

PARIS ROISSY CHARLES DE GAULLE

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

Embases pour raccordement G1/8 - G1/4

Notice Technique / Technical Manual

POLICY: FREE MILK PROGRAM CODE: CS-4

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

GAME CONTENTS CONTENU DU JEU OBJECT OF THE GAME BUT DU JEU

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Contrôle d'accès Access control. Notice technique / Technical Manual

SYSTÈME JETS D AIR WISH WISH AIR JETS SYSTEM Système de massage à jets d air pour bains en polymère - Air jet massage system for polymer bathtubs

DOCUMENTATION - FRANCAIS... 2

Le No.1 de l économie d énergie pour patinoires.

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Fabricant. 2 terminals

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

Contents Windows

WEB page builder and server for SCADA applications usable from a WEB navigator

Paxton. ins Net2 desktop reader USB

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

DOCUMENTATION MODULE BLOCKCATEGORIESCUSTOM Module crée par Prestacrea - Version : 2.0

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

Application Form/ Formulaire de demande

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

Tammy: Something exceptional happened today. I met somebody legendary. Tex: Qui as-tu rencontré? Tex: Who did you meet?

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Garage Door Monitor Model 829LM

APPENDIX 6 BONUS RING FORMAT

Gestion des prestations Volontaire

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

AUDIT COMMITTEE: TERMS OF REFERENCE

ONTARIO Court File Number. Form 17E: Trial Management Conference Brief. Date of trial management conference. Name of party filing this brief

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

Le passé composé. C'est le passé! Tout ça c'est du passé! That's the past! All that's in the past!

France SMS+ MT Premium Description

How to Login to Career Page

lundi 3 août 2009 Choose your language What is Document Connection for Mac? Communautés Numériques L informatique à la portée du Grand Public

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

Package Contents. System Requirements. Before You Begin

ENGLISH 4 FRANÇAIS 6 ESPAÑOL 8

FÉDÉRATION INTERNATIONALE DE NATATION Diving

PRINCIPE DE HOTTE SPÉCIALE COMPLÈTE TYPE «RHC» COMPLETE «RHC» TYPE SPECIAL HOOD SYSTEM

If you understand the roles nouns (and their accompanying baggage) play in a sentence...

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

If the corporation is or intends to become a registered charity as defined in the Income Tax Act, a copy of these documents must be sent to:

Once the installation is complete, you can delete the temporary Zip files..

Judge Group: P Title: Quel est meilleur: le compost ou le fertilisant chimique? Student(s): Emma O'Shea Grade: 6

Free filter reminders! Sign up online at: santevia.com/filterease. need help? Contact Santevia!

Principe de TrueCrypt. Créer un volume pour TrueCrypt

BILL 203 PROJET DE LOI 203

PRACTICE DIRECTION ON THE LENGTH OF BRIEFS AND MOTIONS ON APPEAL

Archived Content. Contenu archivé

JSIam Introduction talk. Philippe Gradt. Grenoble, March 6th 2015

Editing and managing Systems engineering processes at Snecma

Stainless Steel Solar Wall Light

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

Nouveautés printemps 2013

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

Start Here Point de départ Epson Stylus

Practice Direction. Class Proceedings

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

VTP. LAN Switching and Wireless Chapitre 4

MONTEGO 3 PERSON CUSHION GARDEN SWING WITH CANOPY ASSEMBLY INSTRUCTIONS ITEM# SC-177-2GS

Grandes tendances et leurs impacts sur l acquisition de produits et services TI.

Exercices sur SQL server 2000

Dans une agence de location immobilière...

22/09/2014 sur la base de 55,03 euros par action

OBJECT PRONOUNS. French III

Micro-ordinateurs, informations, idées, trucs et astuces utiliser le Bureau à distance

Institut français des sciences et technologies des transports, de l aménagement

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

FCM 2015 ANNUAL CONFERENCE AND TRADE SHOW Terms and Conditions for Delegates and Companions Shaw Convention Centre, Edmonton, AB June 5 8, 2015

SERVEUR DÉDIÉ DOCUMENTATION

APPROBATION DES PROCEDURES DE VOL A VUE ET DE VOL AUX INSTRUMENTS

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Dis où ces gens vont d après les images / Tell where these people are going based on the pictures.

Frequently Asked Questions

Règlement relatif à l examen fait conformément à la Déclaration canadienne des droits. Canadian Bill of Rights Examination Regulations CODIFICATION

MASSEY COLLEGE & UNIVERSITY OF TORONTO

I>~I.J 4j1.bJ1UlJ ~..;W:i 1U

À noter, s il vous plaît : Ne pas utiliser de l alcool à friction. Il contient un hydratant et n est pas convenable pour nettoyer des cloisons.

Transcription:

FO-V3 Rectangular Gravity Vent Kit The gravity vent kit uses natural convection to distribute the heat generated by the fireplace to the same floor and/or floors above the fireplace. The maximum duct length allowed is 15 feet from the top of the fireplace to the outlet. The current kit provides 5 feet of insulated flexible duct. You must order additional insulated flexible duct (FO-DUCT5) if you want to extend your run up to 15 feet in total. Two gravity vent kits are necessary if you want to run two gravity vents. WARNING: NO SUBSTITUTION OF ANY OF THESE PARTS IS ALLOWED. STEEL STUDS AND CEMENT BOARD ARE REQUIRED FOR INSTALLATION OF THIS GRAVITY VENT KIT. ENSURE YOU HAVE PROPER MATERIALS BEFORE STARTING. CLEARANCES MUST BE MAINTAINED FOR YOUR SAFETY. THE GRAVITY VENT RUN MUST NEVER RUN IN A DOWNWARD DIRECTION OR HEAT MAY BE TRAPPED IN THE GRAVITY VENT SYSTEM. DO NOT BLOCK AIR FLOW IN FRONT OF THE DECORATIVE GRILL. YOU MUST ALLOW FREE AIR MOVEMENT. INSTALLATION 1. Plan the gravity vent run first. There is no maximum number of bends in a run, but the run must never go in a downward direction as this will trap heat in the gravity vent system. Figure 2 and Figure 3 indicate the minimum clearances and framing dimensions. Passing through a combustible ceiling requires a minimum 14" x 14" opening. Be aware that you will need to install a firestop at the ceiling each time the insulated flexible duct goes through a floor. 2. On the top of the fireplace, remove the outer cover on either the left, right or both sides of the flue outlet. On some models, the hole on the left has a cut-out ring, do not remove it, it will make the hole bigger than necessary. On some models, the opening under the cover may be bigger than the gravity vent starter. Use the gravity vent starter to cut through the insulation by turning it back and forth while pushing down against the insulation. It is important that the insulation be cut as tight as possible to the gravity vent starter. Remove the cut insulation. Then remove the cover plate underneath (it is taped in place). You may have to lift the insulation to find and cut the tape, then just slide the cover out of the way. Do not forget to replace the insulation if necessary. 3. Bend down the three tabs appropriate for your fireplace model (see Figure 1) on the gravity vent starter to 90 then install it on the fireplace It should be pushed all the way down through the insulation until it rests on the three tabs. It should come out below the insulation in the fireplace. Use three of the self-tapping screws provided to attach it to the top of the fireplace. Page 1

4. Attach the round end of the insulated flexible duct to the gravity vent starter on the fireplace. Ensure the insulated flexible duct completely covers the gravity vent starter protruding above the top of the fireplace. Using three of the self-tapping screws with three flat washers provided, screw through the insulated flexible duct to attach it to the gravity vent starter. 5. Extend the insulated flexible duct as desired. You may need some plumber's strapping to support the duct if it runs close to horizontally (always keep a slight slope upwards). To extend the duct beyond the 5' provided, additional 5' lengths can be ordered with the part code FO-DUCT5. 6. Using steel studs, mount the outlet duct. Refer to Figure 2 and Figure 3 for framing requirements. 7. Attach the decorative grill adapter (pre-installed in the duct) to the steel stud header. 8. Install a second steel stud to frame the grill adapter on top and bottom as shown. 9. When ready, cover the wall with cement board. The outlet grill adapter has a ½ lip for the cement board to butt against. 10. Screw the decorative grill to the wall with the black screws provided. Page 2

FO-V3 Trousse d'évent par gravité rectangulaire La trousse d'évent par gravité utilise la convection naturelle pour distribuer la chaleur générée par le foyer sur le même étage ou à des étages supérieurs. La longueur maximale permise des conduits est de 15 pieds du dessus du foyer jusqu'à la sortie du conduit. La trousse actuelle fournit 5 pieds de tuyau isolé flexible. Vous devez commander du tuyau isolé flexible supplémentaire (FO-DUCT5) pour allonger le conduit jusqu'à un maximum de 15 pieds. Deux trousses sont nécessaires si vous désirez deux évents par gravité. MISE EN GARDE : IL EST DÉFENDU DE SUBSTITUER L'UNE OU L'AUTRE DES COMPOSANTES DE CETTE TROUSSE. UNE OSSATURE D'ACIER ET UN PANNEAU DE CIMENT EST REQUIS POUR L'INSTALLATION DE CETTE TROUSSE. ASSUREZ-VOUS D'AVOIR LES MATÉRIAUX REQUIS AVANT DE COMMENCER. LE PARCOURS DU SYSTÈME D ÉVENT PAR GRAVITÉ NE DOIT JAMAIS ÊTRE ORIENTÉ VERS LE BAS CAR CELA POURRAIT PERMETTRE D'EMPRISONER LA CHALEUR À L'INTÉRIEUR DU SYSTÈME D'ÉVENT PAR GRAVITÉ. NE BLOQUEZ PAS LA CIRCULATION D AIR DEVANT LA GRILLE DÉCORATIVE. VOUS DEVEZ PERMETTRE À L AIR DE CIRCULER LIBREMENT. INSTALLATION 1. Prenez le temps de planifier le parcours du conduit d'évent par gravité. Il n'existe aucune limite quant au nombre maximal de coudes sur le parcours du système d'évent par gravité, mais celui-ci ne doit jamais être orienté vers le bas car la chaleur y demeurerait emprisonnée. Les Figure 2 et Figure 3 illustrent les dimensions d'encadrement et les dégagements minimaux. Pour traverser un plafond fabriqué de matériaux combustibles, une ouverture minimale de 14"x14" doit être utilisée. Soyez avisé que vous devrez installer un coupe-feu au plafond chaque fois que le tuyau isolé flexible traverse un plancher. 2. Sur le dessus du foyer, retirez le couvercle extérieur gauche, droit ou les deux selon l'installation désirée. Sur certains modèles, le trou de gauche a un anneau prédécoupé, n'enlevez pas cet anneau, le trou sera alors plus grand que nécessaire. Sur certains modèles, l'ouverture sous le couvercle est plus grande que l'amorce d'évent. Utilisez l'amorce d'évent pour couper à travers l'isolant, il suffit de tourner l'amorce vers la gauche et la droite en un mouvement de va-et-vient tout en appliquant de la force vers le bas. Il est important que l'isolant soit coupé le plus proche possible de l'amorce d'évent. Retirez du trou l'isolant coupé, puis retirez la plaque sous l'isolant (retenue par du ruban adhésif). Vous devrez probablement soulever l'isolant pour trouver et couper le ruban adhésif et pousser la plaque à l'écart. N'oubliez pas de replacer l'isolant à sa place, si nécessaire. Page 3

3. Repliez les trois pattes spécifiques à votre modèle de foyer (voir la Figure 1) à l'horizontale sur l'amorce d'évent puis insérez l'amorce d'évent dans le trou sur le foyer. L'amorce d'évent devrait être poussée au maximum à travers la laine afin d'être appuyée sur les trois pattes et devrait dépasser sous l'isolant dans le foyer. En utilisant trois des vis auto-taraudeuses fournies, vissez l'amorce d'évent sur le dessus du foyer. 4. Installez le conduit flexible isolé sur l'amorce d'évent sur le foyer. Le conduit flexible isolé doit complètement couvrir la partie de l'amorce de sortie qui dépasse au-dessus du foyer. Utilisez trois des vis autotaraudeuses avec trois rondelles plates fournies pour visser à travers le conduit flexible isolé afin de le fixer à l'amorce d'évent. 5. Allongez le conduit flexible isolé tel que désiré. Vous pourriez avoir besoin de sangles de plomberie pour soutenir le conduit s'il est acheminé presqu'à l'horizontale (toujours conserver une légère pente vers le haut). Si vous avez besoin de plus des 5' fournis, des longueurs additionnelles de 5' peuvent être commandées en utilisant le code FO-DUCT5. 6. En utilisant de l'ossature en acier, fixez le conduit de sortie. Référez-vous aux Figure 2 et Figure 3 pour les exigences au niveau de l'encadrement. 7. Fixez l'adaptateur de grille (déjà installé dans le conduit) à la pièce horizontale en acier. 8. Installez une deuxième pièce horizontale en ossature d'acier de façon à encadrer au-dessus et en dessous l'adaptateur de grille tel que montré. 9. Une fois prêt, couvrez le mur avec un panneau de ciment. L'adaptateur de grille a une lèvre de ½" afin de servir de butée au panneau de ciment. 10. Vissez la grille décorative au mur avec les vis noires fournies. Page 4

Delta Fusion, Cameleon2, Pearl/Perle, Figure 1 Gravity vent starter Amorce d'évent par gravité Figure 2 General Installation Installation générale Figure 3 Clearances Dégagements Page 5