EC2 Régulateurs électroniques. TCP/IP Ethernet Description Type Part No. single unit



Documents pareils
Série EC3 Contrôleurs de chambre froide

Fabricant. 2 terminals

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Contrôle d'accès Access control. Notice technique / Technical Manual

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Notice Technique / Technical Manual

WEB page builder and server for SCADA applications usable from a WEB navigator

Paxton. ins Net2 desktop reader USB

NEW Fin Fan / Air cooled condenser cleaning

Instructions Mozilla Thunderbird Page 1

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Contrôle d accès Access control MOD-TCPIP-AI. Notice technique / Technical Manual

Garage Door Monitor Model 829LM

Multisplit premium Duo / DC Inverter

Guide d'installation rapide TFM-560X YO.13

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

Contrôle électronique pour chambres froides

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

Master4Light. Caractérisation Optique et Electrique des Sources Lumineuses. Equipement 2-en-1 : source de courant et spectrophotomètre

How to Login to Career Page

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Nouveautés printemps 2013

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

VTP. LAN Switching and Wireless Chapitre 4

APPENDIX 6 BONUS RING FORMAT

DOCUMENTATION - FRANCAIS... 2

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Application Form/ Formulaire de demande

Utiliser une WebCam. Micro-ordinateurs, informations, idées, trucs et astuces

OPTYMA PLUS New Generation

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Vannes à boisseau sphérique Ball valves

USB 598. Quick Start Guide (Windows) Guide de démarrage rapide (Windows) USB Modem. Modem USB.

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Exemple PLS avec SAS

Z-Axis Compliance Device Compliance en z

DOCUMENTATION - FRANCAIS... 2

Exercices sur SQL server 2000

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

Contents Windows

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Package Contents. System Requirements. Before You Begin

RAPID Prenez le contrôle sur vos données

Once the installation is complete, you can delete the temporary Zip files..

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Lavatory Faucet. Instruction Manual. Questions?

Editing and managing Systems engineering processes at Snecma

Fonctions intégrées. Nouvelles solutions universelles & système de communication

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

Folio Case User s Guide

Micro-ordinateurs, informations, idées, trucs et astuces utiliser le Bureau à distance

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

SERVEUR DÉDIÉ DOCUMENTATION

EHDC. Système de refroidissement pour Data Center et armoires de serveur.

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

lundi 3 août 2009 Choose your language What is Document Connection for Mac? Communautés Numériques L informatique à la portée du Grand Public

Adeunis-RF Softwares. Stand-Alone configuration Manager V2. User guide version V1 FRANCAIS ENGLISH

Monitor LRD. Table des matières

Moteur DC: Comment faire varier sa vitesse?

Logitech Speaker System Z553 Setup Guide Guide d installation

Le No.1 de l économie d énergie pour patinoires.

Developing an alternative scenario in a case study for a single country. Mise en œuvre un scénario alternatif pour une étude de cas pour un seul pays

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

affichage en français Nom de l'employeur *: Lions Village of Greater Edmonton Society

Relais d'arrêt d'urgence, protecteurs mobiles

Igloo. Congélateurs Ultra-Froid -45 o C & -86 o C Armoires & Coffres 370 à 830 litres

Data Center Rittal: standard ou sur mesure? Rittal Yverdon IT

Principe de TrueCrypt. Créer un volume pour TrueCrypt

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Laboratory accredited by the French Home Office (official gazette date February 5 th, 1959, modified) Valid five years from August 27 th, 2013

Quatre axes au service de la performance et des mutations Four lines serve the performance and changes

Please kindly find below a synoptic table showing the various ways of transport from Mahe to La Digue, with a stop over on Praslin:

Gestion des prestations Volontaire

Spécial Catégorie 6 Patch Cords

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

FCM 2015 ANNUAL CONFERENCE AND TRADE SHOW Terms and Conditions for Delegates and Companions Shaw Convention Centre, Edmonton, AB June 5 8, 2015

Practice Direction. Class Proceedings

Guide pour l Installation des Disques Durs SATA et Configuration RAID

Innovation in Home Insurance: What Services are to be Developed and for what Trade Network?

sur le réseau de distribution

Institut français des sciences et technologies des transports, de l aménagement

NOTICE INSTALLATION. ARCHANGE Simplex Office N&B/Couleur KONICA MINOLTA BUSINESS SOLUTIONS FRANCE

PVCHECK Rel /11/12

CEPF FINAL PROJECT COMPLETION REPORT

Embases pour raccordement G1/8 - G1/4

Commutateur statique de transfert Liebert La solution incontournable pour vos systèmes d alimentation à haute disponibilité

Fédération Internationale de Handball. b) Règlement du but

Notre mission : garantir la haute disponibilité de vos données et applications critiques.

PROJECT POUR LE SYSTÈME DE SURVEILLANCE PAR CAMERA BASÉ SUR TECHNOLOGIE AXIS, PANNEAUX SOLAIRES ET LUMIERE DU LEDS BLOC D APARTEMENT LAURIER.

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

Classes of protection IP 65 / IP66 / IP 67 ATEX zone protection Eex "ia" Eex "ed" Eex "em" ATEX II2 G/D

Modules d automatismes simples

AMC 120 Amplificateur casque

Technique de sécurité

BILL 203 PROJET DE LOI 203

Module ATW-C-INV pour commande des unités extérieures d'inverter Fujitsu Airconditioning

Quick Installation Guide TEW-AO12O

Transcription:

La série EC2 est une nouvelle génération de régulateurs électroniques pour la réfrigération. Dans un petit boîtier de format standard industriel, la série comporte 3 versions, tous sont équipés d'une interface de communication LON de Echelon. Option: interface communication TCP/IP Ethernet et serveur. Le programme installé permet d'optimiser la performance du système frigorifique avec de substantiels gains de consommation d'énergie et une mise en service immédiate. Configuration Les versions proposées: EC2-35/37x Series Régulateurs (EXV, press. / temp.) EC2-31/39x Series Régulateurs (EXV, temp. / temp.) EC2-21/29x Series Régulateurs (TXV) EC2-11x Series Régulateurs universels Régulation de la température d air Cycles et durée de dégivrage programmables Fin de dégivrage en fonction d une durée ou d une température. Modes: dégivrage naturel, électrique ou gaz chaud plus contrôle de la ventilation Version EC2-3** permettant la régulation de surchauffe avec une vanne de détente à impulsions (Alco EX2) Régulation auto-adaptative: réglage par l utilisateur non indispensable Limitation supérieure de la température d évaporation (MOT) Support of two network technologies: TCP/IP Ethernet with WebServer functionality allows monitoring and configuration of controllers through a standard WebBrowser (e.g. Internet Explorer or Mozilla Firefox) Interface Echelon LON basé sur le standard de communication LonWorks, permet de configurer l'appareil et la commande à distance via un serveur de supervision. Fonctions pour des temporisations et alarme intégrées Paramètres et fonctions programmables de plusieurs façons: sur clavier, commande à distance infrarouge, sur ordinateur via l'interface LON Protection par mot de passe pour éviter une utilisation non autorisée Certains modèles ont des entrées digitales ALCO CONTROLS EC2 Régulateur électronique Autres caractéristiques Entrées: jusqu'à 5 sondes de températures Sorties:1 pour vanne de détente, 3 pour compresseur, ventilateur, dégivrage, 1 interface LON Dimension standard de découpe 71 x 29 mm Affichage en C ou F Utilisation de sondes NTC précises et économiques Degré de protection IP 65 lorsque monté en façade Options Kit de bornes à visser K02-000, commun a tous les modèles. En option bornes à sertir (série constructeurs) Transformateurs d alimentation 230 / 24 VAC Commande à distance infrarouge EC2-IR** pour le réglage et programmation rapide Selection Table TCP/IP Ethernet Description Type Part No. single unit Part No. Kit* Type LON FTT Part No. single unit Part No. Kit* Temperature/pressure superheat control for EX2 EC2-352 807 772 808 009 EC2-351 807 771 808 008 version for use with a compressor pack system EC2-372 807 688 808 011 EC2-371 807 689 808 010 Temperature/temperature superheat control for EX2 EC2-312 807 682 808 005 EC2-311 807 681 808 004 version for use with a compressor pack system EC2-392 807 692 808 007 EC2-391 807 691 808 006 TXV superheat control EC2-212 807 482 808 001 EC2-211 807 481 808 000 version for use with a compressor pack system EC2-292 807 672 808 003 EC2-291 807 671 808 002 Universal Controller EC2-112 807 472 EC2-111 807 471 EC2 35018_FR_R15.docx 1 / 10 09.08.2011

Introduction Cette nouvelle génération EC2 offre plusieurs avantages par rapport à la génération précédente. L'appareil peut être installé entièrement par l'avant du panneau et fixation uniquement par 2 vis sur la face avant. Une clef allen est fournie pour les vis. Avec la version précédente il fallait accéder à l'arrière du panneau pour passer l'étrier de fixation. Bornes électriques débrochages. Ceci permet un câblage du bornier chez le constructeur de vitrine alors que le régulateur sera installé ultérieurement. Plusieurs versions pour des applications multiples: Les versions EC2-1xx sont universels et peuvent être utilisés pour des applications particulières. Ils peuvent êtres utiles lorsque qu'il y a des unités auxiliaires tels que des équipements de cuisines ou vitrines intégrés nécessitant une surveillance de températures à distance. Il est possible de travailler avec 3 températures ainsi qu'avec 2 entrées digitales. Ces entrées peuvent être paramétrées en liaison avec les sorties digitales via LON en utilisant un logiciel de configuration tel que ANL 220. La commande marche / arrêt de l'éclairage des vitrines réfrigérées est un exemple de fonction qui peut être gérée l'une de ces entrées/sorties digitales. Les versions EC2-2xx pour vitrines réfrigérées gèrent la température, les cycles de dégivrage et la commande d'une vanne liquide pour un circuit avec détendeur classique.ils comportent 2 entrées digitales additionnelles qui peuvent êtres associés à 2 sorties digitales comme décrit ci avant (une sortie Triac en 24 V AC est disponible). Les versions EC2-3xx pour vitrines réfrigérées remplacent les modèles précédents EC2-000 & EC2-001, ils gèrent la température, les cycles de dégivrage et commande une vanne de détente à impulsions tel que le modèle EX2 qui permets d'optimiser la puissance de l'évaporateur. Le débit de fluide dans l'évaporateur est régulé par la vanne de détente à impulsions modèle EX2 d'alco CONTROLS. Les paramètres pour la régulation de la surchauffe sont les températures d'entrée (saturée) et de sortie (surchauffée) à l'évaporateur en tenant compte éventuellement du glissement de température pour certains fluides. La surchauffe peut être régulée suivant 2 modes: - " mode fixe ", elle est maintenue à une valeur déterminée - " mode adaptatif, elle est ajustée de façon automatique entre 3 à 10 K suivant la condition de fonctionnement. Nous recommandons d'utiliser les sondes gainées type ECN-Pxx (voir tableau page 3) sur l'entrée et sortie de l'évaporateur. Elles ont un temps de réponse rapide et procurent une bonne stabilité pour une régulation économique. Comme les autres régulateurs électroniques, ces versions comportent les fonctions de dégivrage, marche compresseur, ventilateur et alarmes. Le régulateur EC2 peut déclencher un dégivrage automatiquement si les conditions le nécessitent "dégivrage sur demande" en établissant une relation entre la température de sortie d'air et celle du fluide saturée. Le dégivrage peut s'effectuer aussi d'une façon traditionnelle à intervalles de temps choisis par l'utilisateur, trois modes sont possibles: dégivrage naturel, électrique ou par gaz chaud. La fin du dégivrage est contrôlée par une sonde de dégivrage ou par la sonde de sortie d'air. Un temps maximum de dégivrage est également programmable. Pendant le dégivrage, le ventilateur de l'évaporateur peut être position arrêt, de même il peut être arrêté lorsque la consigne de température est atteinte. Ceci est particulièrement utile pour les chambres froides. Tous ces modèles peuvent être reliés par le réseau au Serveur Alco type AMS permettant le réglage, surveillance et gestion des alarmes à distance. Fonctions de sécurité: différentes fonctions de sécurité peuvent être utilisées pour protéger le compresseur tels que: - limite supérieure de la température d'évaporation (MOT), temporisation au démarrage, temps minimum entre deux démarrages, temps minimum d'arrêt, temps minimum de marche. Sécurité en cas de défaut de signal de sonde d'air: un mode sécurité permet de continuer la production de froid évitant la dégradation des produits surgelés ou réfrigérés. Les EC2-3xx sont pourvus d'un algorithme maîtrisant le débit de fluide au travers de la vanne EX2, en cas de problème la vanne va recevoir l'ordre de se fermer pour éviter de noyer le compresseur de liquide. Cinq LEDs de signalisation indiquent l'état du compresseur, du ventilateur, du dégivrage, des alarmes et autres paramètres de maintenance. Le clignotement des LEDs indique la présence d'un défaut. Ces types de défaut peuvent être signalés: sonde coupée ou en court circuit, température d'air en dehors de la plage, surchauffe supérieure à 15 K en mode MOT, autres défauts de composant. La programmation des régulateurs EC2 peut être faite de plusieurs façons: à distance via le Serveur AMS si l'interface est utilisée, sur place avec la télécommande à infrarouge ou directement sur le clavier du régulateur sans autre artifice. La supervision et la programmation à distance se fait via l'interface Echelon LON, il est proposé 2 protocoles d'interfaces: FTT10 ou RS485 Des sondes de température d'un coût modéré sont proposées avec plusieurs longueurs de câble pour palier aux besoins spécifiques de l'installation. Les sondes gainées ECN-Pxx pour tube sont utilisées pour le contrôle de la surchauffe, les sondes pour air type ECN-Sxx sont utilisées pour la régulation de l'ambiance, pour la fonction (optionnelle) fin de dégivrage par température, il faut installer une sonde d'ailette type ECN-F60. Pour plus de détails, voir le tableau de sélection. Fiabilité éprouvée: grâce à la technique des cartes avec composants électroniques en surface et à des contrôles intensifs sur chaque appareil en production, le régulateur EC2 réponds à un excellent niveau de qualité. Application The functions of the EC2 Series Display Case Controllers are described in the functional diagrams below: EC2-35x 7 6 9 8 4 3 5 Network With coil out temperature (2) and evaporating pressure (1) the superheat is calculated to define the opening of the Electrical 1 2 EC2 35018_FR_R15.docx 2 / 10 09.08.2011

Control Valve (6). Superheat can be set to a fixed value or an adaptive mode may be used. Air-in temperature sensor (3) and air-out temperature sensor (4) are part of the temperature control loop. The defrost heater (9) can be activated locally by fixed timing intervals or remotely through the communications port. For defrost end termination the fin temperature sensor (5) or the air-out temperature sensor (4) can be used. Fan (8) and compressor (7) are controlled as well. In case of power loss the Electrical Control Valve closes to avoid flooding of the compressor. A separate liquid line solenoid valve is not required. EC2-31x In the EC2-31x Controllers superheat is calculated by measuring coil-in temperature (1) and coil-out temperature (2). All other functions are identical to the EC2-35x Series as described above. The horizontal axis represents the temperature, with St the setpoint for day operation and rd the difference at day, while r6 is the setpoint for night operation and r7 the difference at night. The vertical axis represents cooling operation (1 = cooling, 0 = no cooling). A control parameter allows switching off the evaporator fan during no cooling. Depending on the application, air temperature control may be tied to the air-in or the air-out temperature sensor or a virtual air temperature sensor with the weighted average of air-in and airout temperatures. A more precise temperature control can be achieved (EC2-3xx only) by using the modulating temperature mode as shown below: Network 7 6 9 8 4 3 5 1 2 EC2-21x The EC2-21x model is a traditional case controller with a thermostat for temperature control used in conjunction with conventional solenoid valve and TXV. All functions and features except electronic superheat control are identical to the EC2-3xx Series. Two volt free digital inputs of the EC2-211 LON FTT-10 version may be logically bound using any LON management software such as ANL-220 to the digital output. This function is also possible with the EC2-212 when utilising the SNMP protocol. Switching the lights on/off is one such application for the additional inputs & output. Superheat Control The EC2-3xx Series controls evaporator superheat by varying the mass flow through the Electrical Control Valve (ECV). The controller automatically calculates the valve opening time required for the correct refrigerant mass flow by measuring pressure and temperature at the evaporator output (EC2-35x) or by measuring coil-in temperature and coil-out temperature (EC2-31x). ECN-Pxx pipe type temperature sensors and PT4 pressure transmitters from ALCO Controls must be used. The controller works in two operating modes: fixed superheat and adaptive superheat. In the fixed mode, the superheat setpoint is fixed to a user-defined value. In the adaptive mode the controller varies superheat setpoints in the range between 3K and 15 K depending on system conditions to maintain stable operation. The pressure drop through a distributor or the glide associated with certain refrigerants (e.g. R407C) can be compensated in the controller. Temperature Control (besides EC2-111/-112) The ECN-Sxx air sensors are used for temperature control of the display case. The dead band control function is described in the diagram below: The horizontal axis represents the temperature, the vertical axis the superheat setting. At high temperatures, the controller works with minimum superheat. St is the setpoint for day operation, at which the superheat is already increased. rd specifies the proportional band in which the superheat is modulated. Equivalent is r6, the setpoint for the night operation and r7 the width of the proportional band at night. At a temperature of St minus ½*rd (day) or r6 minus ½*r7 (night) the valve is closed. In case the controller should be used in a heat pump for heating, the function of the temperature controller can be inversed: When used with a standard condensing unit, the compressor relay can be used to switch the coil of power contactor. The compressor relay is not used in a refrigeration system with a rack controller. In this application, the electrical control valve closes when the thermostat setpoint has been reached and the rack will automatically pump down if there is insufficient demand from the rest of the refrigeration system. Defrost EC2 Series Controllers allow local defrost management through the built-in defrost timer but also permit remote defrost scheduling through the networking connection. For remote defrost details please consult the operating instructions. Two basic defrost modes are possible: Natural Defrost For medium temperature applications without defrost heaters. In this mode the evaporator fans are turned on during the defrost period. Electrical / hot gas defrost All timing parameters can be selected to cover specific defrost modes, see the diagrams below for the function of defrost output and fan output at defrost: Fan Defrost Defrost can be activated after power up (d4 flag) and the delay (d5). Delay (d6) allows for pump down. The defrost will end EC2 35018_FR_R15.docx 3 / 10 09.08.2011

either when the defrost termination temperature (dt) has been exceeded or after the maximum defrost duration (dp). Other delays take care for synchronization of multiple evaporators in the same system (du), for drain (d7) and for injection (d8). The next defrost will occur after the specified defrost interval (di). Fans can be switched off at defrost (F3 flag) and switched on after defrost and drip time delay (Fd). End of defrost is detected by the dedicated defrost temperature sensor ECN-F60 or alternatively by the air-off temperature sensors ECN-Sxx. Sensors Low cost NTC sensors are available with different cable lengths to meet specific customer's requirements for optimal positioning of the sensors. All sensors are hermetically sealed for high reliability and long life. Air sensors have a plastic housing, pipe and fin sensors have metal housings for optimal thermal conductivity and the fin sensor has an additional mounting clip. Display and Keypad With the 2½ digit display temperatures within ±199 C can be shown with a resolution of 1 C. The resolution improves to 0.1 C within a range of ±19.9 C. The display unit can be switched from C to F. When displaying F the same resolution as above applies. Indicator LEDs show the status of compressor, fan, defrost and alarm. A blinking LED indicates that the EC2 Controller is trying to fulfill a task but is prevented from doing so by another restraint in the system. An example of this would be the minimum compressor run time. Operation and Commissioning Setup and commissioning of an EC2 Series Controller may be performed by using one of the following options: - Locally or remote with a PC connected to the TCP/IP Ethernet port of the EC2. - Remotely via the EMS Server connected to the LON port of an EC2. - Locally through the 4-button keypad. For initial commissioning of a new installation depending on the networking technology of the EC2 the first two options are the most appropriate. Commissioning is done via dedicated menus with meaningful default values, which make commissioning an EC2 a plug-and-play type of job. Anybody who is familiar with Microsoft Windows based programs and WebBrowsers should find it very intuitive without the need for special training. WebServer function of the EC2 with TCP/IP Ethernet networking capabilities Though the actual status of the controllers can be viewed on the local display, it is much more convenient to do the viewing on a PC. All relevant parameters and modes are visible on a single WebPage simultaneously. For even more details and for setup and maintenance a click on one of the screen tabs calls up a WebPage dedicated to specific task. All of this can be done with a standard WebBrowser like the Internet Explorer, the Mozilla Firefox or others. The picture on page 4 shows the homepage of an EC2-312 with the monitoring WebPage of the controller. Echelon LON Networking Capabilities of the EC2 The remote access, viewing and monitoring features of the LON version EC2 Series Controllers match and exceed the capabilities of their TCP/IP counterparts. Though remote access requires the use of the Emerson EMS Monitoring Server or special third party LON compliant hardware and software, many more additional functions and features are available. The LON version EC2 Controllers are equipped with FTT10 (free topology) transceiver types. This offers the installer greatest flexibility in the way the controllers are connected to the LON network in addition to offering higher communication transmission rates. When connected to the LON network, the individual EC2 Series Controllers may be bound together through peer-to-peer communication to form self-contained control loops for applications such as synchronised defrosting. Retrieval and download of setups and data is very comfortable and easily achievable in LON systems. Refer to the "Alco Networking Application" sheets for further details. Where to apply TCP/IP Ethernet vs. LON Controllers In general TCP/IP Ethernet controllers are more applicable for small and medium refrigeration systems with only a few pieces of refrigeration equipment. No special hardware or special software is needed and whoever can set up a small PC network has all the necessary know-how to set up and operate EC2 and EC3 TCP/IP Ethernet controllers. In larger installations LON has its merits. Network wiring is easier and less costly. Peer-to-peer communication is another benefit of LON and data retrieval and storage are very easily achievable. These advantages come at a price however: a monitoring and server device like the Emerson EMS is needed along with some special know-how in LON technology. The associated cost therefore makes LON technology primarily applicable in large refrigeration plants with many pieces of refrigeration equipment like Supermarkets or large cold storage facilities. EC2 35018_FR_R15.docx 4 / 10 09.08.2011

The top fields indicate status of compressor, defrost heater and fan (left) and a general alarm (right). The fields below show temperatures, pressure (EC2-352 only) of all sensors attached to the controller as well as the setpoints for air temperature and superheat. The actual value for superheat and the valve opening are displayed too. All status messages (thermostat, defrost and evaporator) are displayed in the lower section with normal font, all active messages are in bold letters. A rolling graph with air temperature and superheat data over a period of approximately 10 minutes can be displayed: Alarm / maintenance functions EC2 Series Controllers provide many alarm codes to facilitate diagnosis. Limit violation alarms are associated with temperature and pressure set point (high-, low alarm, sensor failure). Alarm management includes the issuing of an alarm message through the network and to show the alarm code on the controllers display. The priorities and subsequent actions can be individually defined for each alarm when connected to a PC or an EMS monitoring server. The TCP/IP Ethernet versions EC2 Controllers have the capability to send alarm messages directly by email. While the display indicates alarms as blinking symbols only, the monitoring WebPage shows all alarms in text form. All possible alarm messages are visible, active alarms are highlighted bold, see below: A logfile can be stored on the PC. The file format of the datalog is text with semicolon (;) separated fields. On the picture below is a sample log file from an EC2-312, imported in Microsoft Excel : All WebPages, which allow the change of controller parameters, are password protected. Below is the example for the thermostat configuration WebPage of an EC2-312 Controller. The set points of day and night operation, as well as the settings which will initiate an alarm can be easily reviewed and modified if needed: Safety Functions Various safety functions are available for use particularly when the EC2 is controlling the compressor directly. These safety features are used to prevent compressor damage and include: Limitation of maximum evaporating pressure (MOP), delay of compressor start after control reset, minimum time between two starts, minimum compressor off time, minimum compressor run time. Safe operating modes allow the system to continue to operate safely even when the signal is lost from a defective or disconnected sensor. Particularly useful facilities are the service functions, which enable the engineer to manually control the system during commissioning. They include manual operation of compressor, fan and Electrical Control Valve, or special operating modes of system for cleaning, permanent night operation, manual defrost or others, see below: EC2 35018_FR_R15.docx 5 / 10 09.08.2011

Electrical Connection For electrical connection removable screw connectors can be used. This allows the electrical wiring to be completed at the display case manufacturer and the controller is simply pluggedin on site when necessary. The terminal Kit must be ordered separately For TCP/IP controllers an Ethernet cable must be used. The assembled cable ECX-N60 comes with RJ45 connector on one side and the 4-pin screw connector at the other. Accessoires Typical Screw Connctor Kit EC2-312, Rear side Kit de bornes et cables Type Code N Kit de bornes EC2-35x / -37x / -31x / -39x K02-000 800 050 Kit de bornes EC2-21x / -29x / -11x K02-211 807 647 Ethernet cable (TCP/IP, RJ45/4-pin-conn.) 6,0m ECX-N60 804 422 Pulse Width Modulated Electrical Control Valves (for details see datasheet EX2) Nominal capacity R404A 0,06 to 12,1kW EX2-I00 801 090 Orifice 4 0,7 to 7,7kW EXO-004 801 089 Orifice 3 0,5 to 5,1kW EXO-003 801 088 Orifice 2 0,3 to 3,0kW EXO-002 801 087 Orifice 1 0,2 to 2,3kW EXO-001 801 086 Orifice 0 0,1 to 1,1kW EXO-000 801 085 Orifice X 0,06 to 0,6kW EXO-00X 801 084 Coil 24VAC ASC 24V 801 052 Cable and connector assembly for EX2 1.5m length ASC-N15 804 570 3m length ASC-N30 804 571 6m length ASC-N60 804 572 Sonde NTC pour air 1,5m cable length ECN-S15 804 304 (10kΩ at 25 C) 3m cable length ECN-S30 804 305 6m cable length ECN-S60 804 284 Sonde NTC pour tube 3m cable length ECN-P30 804 280 (10kΩ at 25 C) 6m cable length ECN-P60 804 281 8m cable length ECN-P80 804 282 Sonde NTC pour évaporateur, clips d'ailette, fils avec embout (10kΩ at 25 C) 6m cable length ECN-F60 804 283 ECN-Sxx Sonde NTC pour air ECN-Pxx Sonde NTC pour tube ECN-Fxx Fin Sensor PT5-07M Pressure Transmitter with Cable Plug Assembly PT4-Mxx Pressure Transmitter Cable Assembly for PT5-0.8 7bar 0 18bar 1.5m cable length 3m cable length 6m cable length PT5-07M PT5-18M PT4-M15 PT4-M30 PT4-M60 802 350 802 351 804 803 804 804 804 805 ECT-323 ECT-523 Transformateur d alimentation Class II 230VAC Input, 24V output, 25VA, DIN 115-230VAC Input, 12/24V output, 20VA ECT-323 804 442 ECT-523 804 332 Exemple de liste matériel pour une vitrine réfrigérée: Régulateur (EXV) EC2-311 807 681 Détendeur à EX2- M00 801 091 impulsions Restricteur N 2 EXO-003 801 088 Kit de bornes K02-000 800 050 Sondes pour tube (2) ECN- P60 804 281 Sondes pour air (2) ECN- S30 804 305 Sonde pour ailette ECN- F60 804 283 Transformateur ECT-523 804 332 EC2 35018_FR_R15.docx 6 / 10 09.08.2011

Kits Parts List: PCN 808 000 808 001 808 002 808 003 808 004 808 005 808 008 808 009 808 010 808 011 808 006 Kit EC2-211 Ctr. Kit LON EC2-212 Ctr. Kit TCP/IP EC2-291 Ctr. Kit LON 808 007 Terminal Kits K02-000 800 050 1 1 1 1 1 1 1 1 K02-211 807 647 1 1 1 1 Sensors ECN-F60 804 283 1 1 1 1 1 1 1 1 1 1 1 1 ECN-P60 804 281 2 2 2 2 1 1 3 3 4 4 ECN-S60 804 284 2 2 2 2 2 2 Transformers ECT-523 804 332 1 1 1 1 1 1 1 1 1 1 1 1 Pressure Transmitter PT5-07M 802 350 1 1 1 1 Cable Assembly PT4 PT4-M60 804 805 1 1 1 1 EC2-292 Ctr. Kit TCP/IP EC2-311 Ctr. Kit LON EC2-312 Ctr. Kit TCP/IP EC2-351 Ctr. Kit LON EC2-352 Ctr. Kit TCP/IP EC2-371 Ctr. Kit LON EC2-372 Ctr. Kit TCP/IP EC2-391 Ctr. Kit LON EC2-392 Ctr. Kit TCP/IP EC2 35018_FR_R15.docx 7 / 10 09.08.2011

Caractéristiques techniques Tension d'alimentation 24 V AC ±10% 50/60 Hz Plage températures stockage -10 + 70 C Puissance absorbée Entrées : - 5 sondes sur EC2-3xx - 3 sondes et 2 contacts digital sur EC2-1xx et EC2-2xx Sorties : contact de relais cos ϕ = 0.5 pour compresseur, ventilateur et dégivrage Sortie triac pour vanne de détente à impulsions Sortie interface de communication 20 VA pour le EC2-3xx (incluant la vanne EX2) 3 VA pour EC2-11x et EC2-21x) sondes NTC (1) Entrée batterie (temp. saturée) (1) Sortie batterie (gaz surchauffé) (2)Entrée et Sortie Air évaporateur (1)Fin de dégivrage ( optionnel ) contact simple ou inverseur 250 V max 8 A résistif 2 A inductif fonctionnement plage d'application des sondes NTC Affichage LED de signalisation d'état (Variables suivant les modèles) 0 + 50 C (boîtier) -50 + 50 C LED rouges, 2 1/2 digits Décimale automatique entre -19.9 & +19.9 Commutable entre C & F Compresseur, dégivrage, ventilateur, alarme, autre fonction de service Degré de protection IP 65 (montage frontal avec joint ) tension 24 VAC, 1 A maxi. Sondes à utiliser Type NTC 10K @ 25 C RS485 ou FTT10 Poids ~ 150 g Input and Output Configuration EC2-11x EC2-21x / -29x EC2-31x EC2-39x EC2-35x EC2-37x Temperature Inputs 10kΩ @ 25 C, -50 50 C 3 3 5 5 4 4 Pressure Transmitter Input 24VDC, 4 20mA 1 1 Digital Inputs, configurable Volt free contact 2 2 1 1 5V / 0,1mA Output relays, AgNi Inductive (AC15) 250V / 2A Resistive (AC1) 250V / 8A 3 3 3 3 Resistive (AC1) 250V / 6A 4 4 Output Triac for EX2 coil 24VAC 0,1 1A 1 1 1 1 Digital output configurable 4 1 1 1 Communication TCP/IP or Ethernet 10Mbit/sec. LON FTT10 EC2 35018_FR_R15.docx 8 / 10 09.08.2011

Wiring Diagrams TCP/IP: LON: EC2 35018_FR_R15.docx 9 / 10 09.08.2011

Physical dimensions, drawings EC2-3xx, -2xx, -1xx Transformateurs Les informations techniques de cette brochure sont à jour au moment de l'impression du document. Des mises à jour peuvent intervenir, veuillez contacter Emerson dans le cas où une confirmation officielle sur des données serait nécessaire. Les produits et spécifications de cette brochure sont susceptibles de modifications sans préavis. Malgré le soin apporté à la rédaction de ce document, les erreurs de publication n'engagent pas notre responsabilité contractuelle. Les informations données ici sont basées sur des données et des essais que Emerson considère comme fiables et en accord avec les connaissances techniques actuelles. Elles sont destinées uniquement aux personnes possédant les connaissances techniques et la qualification appropriées et agissant en connaissance de cause. Les conditions d'emploi étant en dehors de notre contrôle, nous ne pouvons assumer la responsabilité des résultats liés à une mauvaise utilisation. Nos produits sont conçus et adaptés aux emplacements fixes Pour les applications mobiles, des défaillances peuvent subvenir. L'aptitude à cela doit être assurée par le fabricant qui peut inclure de pratiquer des essais appropriés. Emerson Electric GmbH & Co OHG ALCO CONTROLS Postfach 1251 Heerstraße 111 D-71332 Waiblingen Germany Phone...49-7151-509-0 Fax...49-7151-509-200 www.emersonclimate.eu Benelux Germany, Austria & Switzerland France, Greece, Maghreb Italia Spain & Portugal UK & Ireland Sweden, Denmark, Norway & Finland Eastern Europe & Turkey Poland Russia & Cis Balkan Romania Ukraine Phone: +31 (0)77 324 0 234 +49 (0)6109 6059-0 +33 (0)4 78 66 85 70 +39 02 961 781 +34 93 41 23 752 +44 (0) 1635 876 161 +49 (0)2408 929 0 +49 (0)2408 929 0 +48 (0)22 458 9205 +7 495 981 9811 +385 (0) 1560 38 75 +40 364 73 11 72 +38 44 4 92 99 24 Fax: +31 (0)77 324 0 235 +49 (0)6109 6059 40 +33 (0)4 78 66 85 71 +39 02 961 788 888 +34 93 41 24 2 +44 (0) 1635 877 111 +49 (0)2408 929 528 +49 (0)2408 929 525 +48 (0)22 458 9255 +7 495 981 9816 +385 (0) 1 560 3879 +40 364 73 12 98 +38 44 4 92 99 28 EC2 35018_FR_R15.docx 10 / 10 09.08.2011