Machine Torch Cap-Sensor Switch Replacement Torche machines remplacement du contacteur du capteur de la buse

Documents pareils
GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Lavatory Faucet. Instruction Manual. Questions?

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Logitech Speaker System Z553 Setup Guide Guide d installation

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

R.V. Table Mounting Instructions

Folio Case User s Guide

Package Contents. System Requirements. Before You Begin

Instructions Mozilla Thunderbird Page 1

Contents Windows

Notice Technique / Technical Manual

Contrôle d'accès Access control. Notice technique / Technical Manual

Fabricant. 2 terminals

Guide d'installation rapide TFM-560X YO.13

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

GASKET FOR TONER COLLECTION BOTTLE

Sécurité relative aux sièges auto et aux rehausseurs

ENGLISH 4 FRANÇAIS 6 ESPAÑOL 8

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

MONTEGO 3 PERSON CUSHION GARDEN SWING WITH CANOPY ASSEMBLY INSTRUCTIONS ITEM# SC-177-2GS

lundi 3 août 2009 Choose your language What is Document Connection for Mac? Communautés Numériques L informatique à la portée du Grand Public

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Warning: Failure to follow these warnings could result in property damage, or personal injury.

DOCUMENTATION - FRANCAIS... 2

Nouveautés printemps 2013

Installation Guide. Ceramic Oval Handle Trim Kit

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

SYSTÈME DE GAINES À SPIRALE ET RACCORDS TOURNANTS

SERVEUR DÉDIÉ DOCUMENTATION

Stainless Steel Solar Wall Light

PRESENTATION REMOTE TÉLÉCOMMANDE DE PRÉSENTATION. User Guide Manuel de l utilisateur

How to Login to Career Page

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Logitech Wireless Performance Combo MX800 Setup Guide Guide d installation

Start Here Point de départ

DOCUMENTATION - FRANCAIS... 2

en SCÈNE RATIONAL Rational Démonstration SDP : automatisation de la chaîne de développement Samira BATAOUCHE sbataouche@fr.ibm.com

Embases pour raccordement G1/8 - G1/4

Monitor LRD. Table des matières

Paxton. ins Net2 desktop reader USB

POLICY: FREE MILK PROGRAM CODE: CS-4

VTP. LAN Switching and Wireless Chapitre 4

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

Quick start guide. HTL1170B

WEB page builder and server for SCADA applications usable from a WEB navigator

22/09/2014 sur la base de 55,03 euros par action

Logitech G502 Proteus Core Setup Guide Guide d installation

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

Start Here Point de départ Epson Stylus

PAR_ _09543_EUR DATE: 17/12/2014. Suite à l'avis PAR_ _08654_EUR

SunATM 4.0 Release Notes

If you understand the roles nouns (and their accompanying baggage) play in a sentence...

Information Equipment

LOOPED THREAD OSTEOSUTURE: SMARTLOOP

Gestion des prestations Volontaire

MANUEL MARKETING ET SURVIE PDF

L'Offre sera ouverte pendant 18 jours de bourse, à un prix par action de 152,30 EUR. BPCE International et Outre-Mer

Quick Installation Guide TEW-AO12O

/MC Quick Install Guide Guide d installation rapide

Oracle Database SQL Developer Guide D'Installation Release 4.0 E

Tutoriel de formation SurveyMonkey

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

Table des matières ENGLISH VERSION NEAR BOTTOM OF PAGE. Transferts sécurisés de fichiers Système MFT (Managed File Transfer) Guide de l utilisateur

Guide de récupération de Windows Server 2003 R2 pour serveurs Sun x64

Android. Trucs et astuces

Lecteurs pour bibliothèque L40/80

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

SYSTÈME JETS D AIR WISH WISH AIR JETS SYSTEM Système de massage à jets d air pour bains en polymère - Air jet massage system for polymer bathtubs

Credit Note and Debit Note Information (GST/ HST) Regulations

Guide de démarrage du système modulaire Sun Blade 6000

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

Quatre axes au service de la performance et des mutations Four lines serve the performance and changes

Garage Door Monitor Model 829LM

Utiliser un proxy sous linux

USB 598. Quick Start Guide (Windows) Guide de démarrage rapide (Windows) USB Modem. Modem USB.

FOURTH SESSION : "MRP & CRP"

Trim Kit Installation Instruction

Archived Content. Contenu archivé

CEST POUR MIEUX PLACER MES PDF

DCS-5020L. Pan & Tilt Day/Night Network Camera Cloud Camera. Quick Install Guide

Free filter reminders! Sign up online at: santevia.com/filterease. need help? Contact Santevia!

Once the installation is complete, you can delete the temporary Zip files..

DEMANDE D OUVERTURE DE COMPTE REQUEST OF ACCOUNT OPENING. PROFIL CLIENT Customer Profile. Identité* Identity. Nom de jeune fille* / Maiden name

DOCUMENTATION - FRANCAIS... 2

General Import Permit No. 13 Beef and Veal for Personal Use. Licence générale d importation n O 13 bœuf et veau pour usage personnel CONSOLIDATION

BLUELINEA ,00 EUR composé de actions de valeur nominale 0,20 EUR Date de création : 17/01/2006

MODE D EMPLOI USER MANUAL

À l'approche du festival MUTEK 2015, nous vous contactons pour vous faire part de quelques informations importantes.

Interest Rate for Customs Purposes Regulations. Règlement sur le taux d intérêt aux fins des douanes CONSOLIDATION CODIFICATION

86 rue Julie, Ormstown, Quebec J0S 1K0

DOCUMENTATION MODULE BLOCKCATEGORIESCUSTOM Module crée par Prestacrea - Version : 2.0

GAME CONTENTS CONTENU DU JEU OBJECT OF THE GAME BUT DU JEU

Transcription:

Machine Torch Cap-Sensor Switch Replacement Torche machines remplacement du contacteur du capteur de la buse Field Service Bulletin Bulletin de service sur le terrain 806030 Revision 3 December 2013 Révision 3 Décembre 2013

cap-sensor switch replacement WARNING ELECTRIC SHOCK CAN KILL Disconnect electrical power before performing any maintenance. See the Safety and Compliance Manual included with your system for more safety precautions. Introduction Purpose This Field Service Bulletin describes the procedure for replacing the cap-sensor switch on T45m (Powermax45 ) and the Duramax series (Powermax65/85) machine torches. Powermax105 (Duramax)/Powermax125 (Duramax Hyamp): Complete instructions for installing this repair kit are included in the Service Manual. To download the Service Manual, go to www.hypertherm.com and click the Downloads library link. Powermax105 Service Manual (807580) Powermax125 Service Manual (808070) Materials and tools Assorted Phillips and TORX screwdrivers Kit 228321 contents (T45m) Part number Description Quantity 075704* Machine screw 1 220724 T45m cap-sensor assembly 1 Kit 228720 contents (Duramax/Duramax Hyamp series machine torches) Part number Description Quantity 075618* Machine screw 3 075704* Machine screw 1 220929 Powermax65/Powermax85/Powermax105/Powermax125/MRT/ MRT 2 cap-sensor assembly 1 * Screws included with kits as spares if needed. Field Service Bulletin 1

cap-sensor switch replacement Replace the cap-sensor switch (T45m) Please refer to the figures on the following page when performing the instructions below. Remove the cap-sensor switch 1. Turn OFF the power and disconnect the torch lead from the power supply. 2. Remove the consumables from the torch. 3. Remove the gear rack using a screwdriver to remove the 2 black screws that secure it to the positioning sleeve. 4. Remove the 6 screws (3 at each end) that secure the positioning sleeve to the rear mounting ring and to the torch body using a screwdriver. Slide the positioning sleeve off the torch. 5. Disconnect the wire connector for the cap-sensor switch. 6. Remove and discard the cap-sensor switch using a screwdriver to remove the mounting screw. Install the new cap-sensor switch 1. Connect the new cap-sensor switch wire connector to the torch lead. 2. Fasten the cap-sensor switch to the torch body using a screwdriver to tighten the mounting screw. 3. Slide the positioning sleeve over the torch body and check its alignment with the screw holes. Use a screwdriver to install the 6 screws (3 at each end) that secure the positioning sleeve to the rear mounting ring and to the torch body. 4. Attach the gear rack to the sleeve using a screwdriver to tighten the 2 black screws. 5. Replace the consumables and reconnect the torch lead to the power supply. 2 Field Service Bulletin

cap-sensor switch replacement Consumables Positioning sleeve Gear rack Rear mounting ring Strain relief T45m overview Cap-sensor switch mounting screw Cap-sensor switch wire connector Cap-sensor switch Wire connector Switch holder T45m cap-sensor switch detail Field Service Bulletin 3

cap-sensor switch replacement Replace the cap-sensor switch (Duramax series machine torches) Please refer to the figures on the following page when performing the instructions below. Remove the cap-sensor switch 1. Turn OFF the power and disconnect the torch lead from the power supply. 2. Remove the consumables from the torch. 3. If applicable, unscrew the strain relief body from the strain relief nut and slide the strain relief body back along the torch lead. 4. If applicable, unscrew the strain relief nut from the positioning sleeve and slide the nut back along the torch lead. 5. Unscrew the positioning sleeve and coupler (full-length machine torch) or coupler (mini-machine torch) from the mounting sleeve. 6. Remove the three screws from the consumables end of the mounting sleeve using a screwdriver and slide the mounting sleeve off the front of the torch body. 7. Disconnect the wire connector for the cap-sensor switch. 8. Remove and discard the cap-sensor switch using a screwdriver to remove the mounting screw. Install the new cap-sensor switch 1. Install the cap-sensor switch using a screwdriver to tighten the mounting screw to 9.22 kg cm (8 in-lbs). 2. Connect the wire connector for the cap-sensor switch. 3. Slide the mounting sleeve over the front of the torch body, aligning the slot in the mounting sleeve with the capsensor plunger. 4. Tighten the three mounting sleeve screws to 11.52 kg cm (10 in-lbs) using a screwdriver. 5. Thread the coupler (mini-machine torch) or coupler and positioning sleeve (full-length machine torch) into the mounting sleeve until hand tight. 6. If applicable, thread the strain relief nut into the coupler (mini-machine torch) or positioning sleeve (full-length machine torch) until hand tight. 7. If applicable, thread the strain relief body onto the strain relief nut until hand tight. 8. Replace the consumables and reconnect the torch lead to the power supply. 4 Field Service Bulletin

cap-sensor switch replacement Consumables Mounting sleeve Coupler Positioning sleeve Strain relief nut* Torch lead Gear rack Strain relief body* * MRT 2 torches for Powermax600 CE systems do not have a strain relief nut or strain relief body. Full-length machine torch overview Consumables Mounting sleeve Coupler Strain relief body* Strain relief nut* Torch lead * MRT 2 torches for Powermax600 CE systems do not have a strain relief nut or strain relief body. Mini-machine torch overview Mounting sleeve Cap-sensor switch mounting screw Cap-sensor switch Mounting sleeve screws (3) Torch body Cap-sensor switch wire connector Cap-sensor switch detail Field Service Bulletin 5

cap-sensor switch replacement 6 Field Service Bulletin

remplacement du contacteur du capteur de la buse AVERTISSEMENT UN CHOC ÉLECTRIQUE PEUT ÊTRE MORTEL Débrancher l alimentation électrique avant tout entretien. Se au Manuel de sécurité et de conformité compris avec votre système pour d autres mesures de sécurité. Introduction Objet Ce bulletin de service sur le terrain décrit les procédures de remplacement du contacteur du capteur de buse sur les torches machines T45m (Powermax45) et des séries Duramax (Powermax65/85). Powermax105 (Duramax)/Powermax125 (Duramax Hyamp) : Les instructions complètes pour l installation de ce kit de réparation sont incluses dans le Manuel de service. Pour télécharger le Manuel de service, se rendre sur www. hypertherm.com et cliquer sur le lien «Bibliothèque des téléchargements». Manuel de service du Powermax105 (807580) Manuel de service du Powermax125 (808070) Matériel et outils requis Tournevis Phillips et TORX divers Contenu du kit 228321 (T45m) Numéro Description Quantité de référence 075704* Vis mécanique 1 220724 Ensemble du capteur de la buse, T45m 1 Contenu du kit 228720 (Torches machines séries Duramax/Duramax Hyamp) Numéro Description Quantité de référence 075618* Vis mécanique 3 075704* Vis mécanique 1 220929 Ensemble du capteur de la buse Powermax65/Powermax85/Powermax105/Powermax125/MRT/ MRT 2 1 * Les vis contenues dans les kits sont des vis de rechange, le cas échéant. Bulletin de service sur le terrain a-1

remplacement du contacteur du capteur de la buse Remplacement du contacteur du capteur de buse (T45m) Se reporter aux figures de la page suivant lors de l exécution des instructions ci-dessous. Retrait du contacteur du capteur de buse 1. Couper l alimentation (OFF) et débrancher le faisceau de torche de la source de courant. 2. Retirer les consommables de la torche. 3. Dévisser les deux vis noires qui fixent solidement la crémaillère dans la gaine de positionnement avec le tournevis puis déposer la crémaillère. 4. Retirer les six (6) vis (trois à chaque extrémité) qui fixent solidement la gaine de positionnement à la bague de montage arrière et au corps de la torche avec le tournevis. Glisser la gaine de positionnement hors de la torche. 5. Débrancher le connecteur du fil du contacteur du capteur de la buse. 6. Retirer le contacteur de détection de la buse en utilisant un tournevis pour retirer la vis de montage. Installation du contacteur du capteur de buse 1. Brancher le contacteur neuf du capteur de la buse au faisceau de torche. 2. Fixer le contacteur du capteur de la buse au corps de la torche avec la vis de montage. Serrer avec le tournevis. 3. Glisser la gaine de positionnement sur le corps de la torche et vérifier le bon alignement avec les trous de vis. Enfiler les six (6) vis (trois à chaque extrémité) qui fixent solidement la gaine de positionnement à la bague de montage arrière et au corps de la torche et serrer avec le tournevis. 4. Fixer la crémaillère à la gaine avec les deux (2) vis noires; les serrer avec le tournevis. 5. Remettre en place les consommables et rebrancher le faisceau de torche à la source de courant. a-2 Bulletin de service sur le terrain

remplacement du contacteur du capteur de la buse Consommables Gaine de positionnement Crémaillère d engrenage Bague de montage arrière Serre-câble Vue d ensemble de la T45m Vis de montage du contacteur du capteur de la buse Connecteur de fil du contacteur du capteur de la buse Contacteur du capteur de la buse Connecteur de fil Porte-contacteur Détail du contacteur de détection de buse de la T45m Bulletin de service sur le terrain a-3

remplacement du contacteur du capteur de la buse Remplacement du contacteur du capteur de buse (Torches machines séries Duramax) Se reporter aux figures de la page suivant lors de l exécution des instructions ci-dessous. Retrait du contacteur du capteur de buse 1. Couper l alimentation et débrancher le faisceau de torche de la source de courant. 2. Retirer les consommables de la torche. 3. Le cas échéant, dévisser le corps du serre-câble de son écrou puis ramener le corps du serre-câble le long du faisceau de torche. 4. Le cas échéant, dévisser l écrou du serre-câble de la gaine de positionnement puis le ramener le long du faisceau de torche. 5. Dévisser la gaine de positionnement et le coupleur (torche machine pleine longueur) ou le coupleur (mini-torche machine) du collier de montage. 6. Retirer les trois (3) vis du côté des consommables du collier de montage avec le tournevis et glisser le collier de montage vers l avant du corps de la torche pour le retirer. 7. Débrancher le connecteur du fil du contacteur du capteur de la buse. 8. Retirer le contacteur du capteur de la buse en utilisant un tournevis pour retirer la vis de montage. Installation du contacteur du capteur de buse 1. Installer le contacteur de détection de la buse en utilisant un tournevis pour serrer la vis de montage à 9,22 kg cm. 2. Brancher le connecteur du fil du contacteur du capteur de la buse. 3. Glisser le collier de montage sur l avant du corps de la torche. Aligner la rainure du collier de montage avec le plongeur du capteur de la buse. 4. Serrer les trois vis du collier de montage à l aide d un tournevis à un couple de 11,52 kg cm. 5. Visser à la main le coupleur (mini-torche machine) ou le coupleur et la gaine de positionnement (torche machine pleine longueur) dans le collier de montage jusqu à ce qu ils soient bien serrés. 6. Le cas échéant, visser à la main l écrou du serre-câble dans le coupleur (mini-torche machine) ou la gaine de positionnement (torche machine pleine longueur) jusqu à ce qu il soit serré. 7. Le cas échéant, visser à la main le corps du serre-câble dans son écrou jusqu à ce qu il soit serré. 8. Remettre en place les consommables et rebrancher le faisceau de torche à la source de courant. a-4 Bulletin de service sur le terrain

remplacement du contacteur du capteur de la buse Consommables Collier de montage Coupleur Gaine de positionnement Écrou du serre-câble* Faisceau de torche Crémaillère d engrenage Corps du serre-câble* * Les torches MRT 2 pour les systèmes Powermax600 CE ne possèdent pas d écrou ou de corps de serre-câble. Vue d ensemble de la torche machine pleine longueur Consommables Collier de montage Coupleur Corps du serre-câble* Écrou du serre-câble* Faisceau de torche * Les torches MRT 2 pour les systèmes Powermax600 CE ne possèdent pas d écrou ou de corps de serre-câble. Vue d ensemble de la mini-torche machine Collier de montage Vis de montage du contacteur du capteur de la buse Contacteur du capteur de la buse Vis du collier de montage (3) Corps de la torche Connecteur de fil du contacteur du capteur de la buse Détail du contacteur de détection de buse Bulletin de service sur le terrain a-5

remplacement du contacteur du capteur de la buse a-6 Bulletin de service sur le terrain

Hypertherm Inc. 2013 All rights reserved Tous droits réservés Hypertherm, Powermax, and Duramax are trademarks of Hypertherm Inc. and may be registered in the United States and/or other countries. Hypertherm, Powermax et Duramax sont des marques d Hypertherm Inc. qui peuvent être déposées aux États-Unis et/ou dans d autres pays. Hypertherm, Inc. Hanover, NH 03755 USA 603-643-3441 Tel Hypertherm Europe B.V. 4704 SE Roosendaal, Nederland 31 165 596907 Tel Hypertherm (Shanghai) Trading Co., Ltd. PR China 200231 86-21-60740003 Tel Hypertherm (S) Pte Ltd. Singapore 349567 65 6 841 2489 Tel Hypertherm (India) Thermal Cutting Pvt. Ltd. Chennai, Tamil Nadu 91 0 44 2834 5361 Tel Hypertherm Brasil Ltda. Guarulhos, SP - Brasil 55 11 2409 2636 Tel Hypertherm México, S.A. de C.V. México, D.F. 52 55 5681 8109 Tel Hypertherm Korea Branch Korea, 612-889 82 51 747 0358 Tel www.hypertherm.com