BO600RP/BO600RH Horizontal & Vertical retrofit housing Bandeau architectural horizontal & vertical P300RP/P600RP Retrofit handle Poignées ventouse



Documents pareils
Contrôle d'accès Access control. Notice technique / Technical Manual

Notice Technique / Technical Manual

Paxton. ins Net2 desktop reader USB

Lavatory Faucet. Instruction Manual. Questions?

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

Fabricant. 2 terminals

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

Z-Axis Compliance Device Compliance en z

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

FRANCAIS DGM1. Centrale Vigik 1 porte. N d homologation : - PS MS Gamme: Vigik MANUEL D INSTALLATION.

Folio Case User s Guide

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

DGA. Self Contained Digicode Keypad Digicode avec électronique intégrée INSTALLATION MANUAL MANUEL D INSTALLATION. Group Company

Contrôle d accès Access control MOD-TCPIP-AI. Notice technique / Technical Manual

Guide d'installation rapide TFM-560X YO.13

Guide d installation Deco Drain inc. DD200

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Instructions Mozilla Thunderbird Page 1

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Embases pour raccordement G1/8 - G1/4

R.V. Table Mounting Instructions

Electroserrures à larder 282, 00

SYSTÈME JETS D AIR WISH WISH AIR JETS SYSTEM Système de massage à jets d air pour bains en polymère - Air jet massage system for polymer bathtubs

APPENDIX 6 BONUS RING FORMAT

WEB page builder and server for SCADA applications usable from a WEB navigator

NOGENT PERCHE HABITAT Office Public de l Habitat

How to Login to Career Page

L. Obert, T. Lascar, A. Adam

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Judge Group: P Title: Quel est meilleur: le compost ou le fertilisant chimique? Student(s): Emma O'Shea Grade: 6

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Le passé composé. C'est le passé! Tout ça c'est du passé! That's the past! All that's in the past!

POLICY: FREE MILK PROGRAM CODE: CS-4

Pièces métalliques pour équipement des coffrets. Metal components for High-End Trunks / Cases / Boxes

lundi 3 août 2009 Choose your language What is Document Connection for Mac? Communautés Numériques L informatique à la portée du Grand Public

Utiliser une WebCam. Micro-ordinateurs, informations, idées, trucs et astuces

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

Once the installation is complete, you can delete the temporary Zip files..

PRINCIPE DE HOTTE SPÉCIALE COMPLÈTE TYPE «RHC» COMPLETE «RHC» TYPE SPECIAL HOOD SYSTEM

GASKET FOR TONER COLLECTION BOTTLE

Software and Hardware Datasheet / Fiche technique du logiciel et du matériel

SYSTÈME DE GAINES À SPIRALE ET RACCORDS TOURNANTS

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Acce s aux applications informatiques Supply Chain Fournisseurs

Application Form/ Formulaire de demande

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

2/ Configurer la serrure :

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

Deadline(s): Assignment: in week 8 of block C Exam: in week 7 (oral exam) and in the exam week (written exam) of block D

Contents Windows


Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Package Contents. System Requirements. Before You Begin

DGM4 KIT DGM4 TDG4. Centrale Vigik 4 portes MANUEL D INSTALLATION. Gamme: Vigik. Group Products

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

VTP. LAN Switching and Wireless Chapitre 4

Eco-Conception. Démarche et livrables Guy Laudereau Sept 2008 technique. environnement. attentes des clients. coût

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Logitech Speaker System Z553 Setup Guide Guide d installation

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

Principe de TrueCrypt. Créer un volume pour TrueCrypt

Nouveautés printemps 2013

MONTEGO 3 PERSON CUSHION GARDEN SWING WITH CANOPY ASSEMBLY INSTRUCTIONS ITEM# SC-177-2GS

ARP-090G / ARP-090K NOTICE D'EMPLOI INSTRUCTION MANUAL

SÉCURIBLOC 31 / 30. La rénovation plus pratique et plus esthétique : label A2P* (1) ou version standard

Caractéristiques techniques du module électronique Témoin lumineux rouge

Practice Direction. Class Proceedings

Garage Door Monitor Model 829LM

Coffrets de table Accessoires

Notice de montage DORMA AGILE 150 DORMOTION Montage mural

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

AIDE FINANCIÈRE POUR ATHLÈTES FINANCIAL ASSISTANCE FOR ATHLETES

Innovation in Home Insurance: What Services are to be Developed and for what Trade Network?

DOCUMENTATION MODULE BLOCKCATEGORIESCUSTOM Module crée par Prestacrea - Version : 2.0

Exercices sur SQL server 2000

SLIM ATIC Multipoints / Motorisée Microswitch Mécanique Série

DCS-5020L. Pan & Tilt Day/Night Network Camera Cloud Camera. Quick Install Guide

DOCUMENTATION - FRANCAIS... 2

Stérilisation / Sterilization

CHIFFRES CLÉS. IMport

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

PARIS ROISSY CHARLES DE GAULLE

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

Tutoriel de formation SurveyMonkey

Installation de la serrure e-lock multipoints

Gestion des prestations Volontaire

LA RUBRIQUE «SUR MESURE»

RAPID Prenez le contrôle sur vos données

Quick Installation Guide TEW-AO12O

Barrières infrarouge actif double faisceaux Multi fréquences SBT 30F-60F-80F-100F-150F Notice d installation. Logo

Editing and managing Systems engineering processes at Snecma

Sécurité relative aux sièges auto et aux rehausseurs

PRESENTATION. CRM Paris - 19/21 rue Hélène Boucher - ZA Chartres Est - Jardins d'entreprises GELLAINVILLE

UP 588/13 5WG AB13

NUGELEC. NOTICE D'UTILISATION DU B.A.A.S. du type Ma - STI / MaME - STI. pages. 1 introduction 2. 2 encombrement 3 fixation

Transcription:

GLISH ANCAIS P300RP / Horizontal & Vertical retrofit housing & vertical P300RP/P600RP Retrofit handle Poignées ventouse The installer s choice

INSTALLATION MANUAL INSTALLATION MANUAL Thank you for buying our products and for the confidence you placed in our company. 1] PRODUCTS OVERVIEW NFS 61-937. Pre-assembled. Fast installation. Covers previous installation fixing holes. Pre-drilled sections (adjustable). Ergonomic design. SAA finish (Satin Anodised Aluminium). Aesthetic. Suitable for metal, wood and glass doors. Ideal for retrofit applications. Magnets supplied with terminal blocks. Groove at the back of the magnet housing for cable management. Magnet housing supplied with cover. Options: Aluminium rail spacers, Aluminium cable tray, Installation on glass door (UBK2), RAL colour, Monitored NO/NC, Cut to size. Holding force: 2 x 300kg, Dimensions (L x W x D): - = 92 x 10 x 62mm, - STD = 2190 x 10 x 63mm, - = 200 x 10 x 63mm. Magnet housing for frame mount. Armature housing with end caps for door mount. Input voltage: 12/24/48V dc. Consumption: - 12V dc = 00mA (per magnet), - 24V dc = 20mA (per magnet), - 48V dc = 20mA (for both magnets). WEEE CE Certification -20 C to +70 C 63,2 ALMA 60 30,9 28,6 2,3 AME DOOR LEAF Recommended Power supplies ARD24 REO 8,8 2,3 7,7 DOOR AME FIXED LEAF BS602 BS24 10 8,8 30,9 28,6 REO 37 ALMA 63,2 60 MOUNTING HIGH RESISTANCE TO VANDALISM 7,7 DOOR OPING LEAF 37 10 Product Details 2] INFORMATION & RECOMMDATIONS Power Considerations The handle is designed to house electromagnets with a holding force of 300Kg each. These units can be supplied by either 12Vdc or 24Vdc depending upon your preferred choice (48Vdc supplied on special request). The current required depends on the amount of electromagnetic locks, and the voltage chosen please see Technical Specification, and ensure you have allocated sufficient power to (200mm housing with 2 magnetic locks) would require: PSU12/2 or ARD2/12 at 12Vdc PSU24/1 or ARD24 at 24Vdc. Information The electromagnets are pre-fitted within the lock section. The armature plates are pre-fitted within the architectural handle. Both sections are supplied with end caps. 200MM STD 2190MM 92 MM Number of 300Kg magnets 2 2 2 Lock section with cover 1 1 1 Architectural handle with fixing cover 1 1 1 End caps for handle 2 2 2 End caps for lock section 2 2 2 RAL colour (option) - Cut to size (option) - 3 or 4 magnetic locks (option) - - Monitored (option) - 3] PACKAGE CONTTS 200 mm STD 2190 mm 92 mm Profiled handle with end caps Profiled handle fixings cover Box section back-plate Wiring Plan your cable routes before commencing installation. We recommend a maximum distance of 10m from the power supply to the electromagnetic locks (to prevent volt drop). If the distance is greater, then make sure you have increased the cross section of the cable to compensate. General Advice The 2 parts of the architectural housing are designed to be surface mounted on the door and frame, where they should be parallel when the door is closed. If there is a rebate, then it will be necessary to pack out the lower part to be parallel to the other (Aluminium rail spacer, Ref: REO). You can also use the PRP800 (Reinforcement section) or ALMA (Aluminium Cable tray) to reinforce the housing mounting. Handle () You must secure the handle with the 2 screws which comes with the retrofit housing. Box section cover End caps Handle screw kit Manual 1 1 1 1 2 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 2-1 1 2 3

INSTALLATION MANUAL INSTALLATION MANUAL 4] ASSEMBLY 1 2 3 Position the box-section backplate, complete with pre-fitted electro-magnetic locks, on to the door frame - ensure the positioning will allow for the architectural handle to close securely over the section. Once you are satisfied with the position, mark the vertical and horizontal holes, then drill as required. Take note of the cable entry holes, and feed the cables through. Fix the section into place, then wire the electromagnetic locks in accordance with the wiring schematic in Section. Fit the box section cover into place, fix the end caps and secure with the screws provided. To finalise the assembly, tighten all fixings, and protect the handle fixing section by fitting the cover and end caps. With the door closed, position the architectural handle onto the edge of the opening leaf of the door, ensuring the handle covers the box-section. Mark the vertical and horizontal holes, drill as required, then temporarily fix the handle leaving a small gap around the box section check the alignment of the magnets in the box section with the armatures in the handle. Adjust if necessary, then once satisfied, secure the handle by completing the fixings. Insert the end caps and secure. Position the box-section backplate, complete with pre-fitted electromagnetic locks, on to the door frame (or fixed door leaf if installing onto double doors) - ensure the positioning will allow for the architectural handle to close securely over the section. Once you are satisfied with the position, mark the vertical and horizontal holes, then drill as required. Take note of the cable entry holes, and feed the cables through. Fix the section into place, then wire the electromagnetic locks in accordance with the wiring schematic in Section. Fit the box section cover into place, fit the end caps and secure with the screws provided. To finalise the assembly, tighten all fixings, and protect the handle fixing section by fitting the cover and end caps. With the door closed, position the architectural handle onto the edge of the opening leaf of the door, ensuring the handle covers the box-section. Mark the vertical and horizontal holes, drill as required, then temporarily fix the handle leaving a small gap around the box section check the alignment of the magnets in the box section with the armatures in the handle. Adjust if necessary, then once satisfied, secure the handle by completing the fixings. Cut the top cover unit into 2 pieces. Double check the length of each section of top cover before final cutting. Take into account the plastic handle (21MM). Ensure the plastic handle is at optimum position for users, then make the final cuts to the covers. Insert the end caps and secure. Insert the plastic handle and clip it into position. Secure the handle with the 2 screws. 4

INSTALLATION MANUAL INSTALLATION MANUAL ] WIRING 6] NOTES Example N 1: Exit button only (VHLD timer optional) -WAY TERMINAL STRIP NON MONITORED VERSION + 12Vdc or 24Vdc positive * - 12Vdc or 24Vdc negative * 12Vdc 24Vdc Voltage 12Vdc or 24Vdc Exit Button RANGE 2 x 300KG magnetic locks N 1 N 2 Example N 2: Access Control + Exit Button * Voltage: 12Vdc or 24Vdc. Place the «jumpers» to select 12Vdc or 24Vdc supply to your magnetic locks OPTIONS -WAY TERMINAL STRIP MONITORED VERSION + 12Vdc or 24Vdc positive * - 12Vdc or 24Vdc negative * NC Contact «Normally Closed» COM Common NO Contact «Normally Open» * Voltage: 12Vdc or 24Vdc. Place the «jumpers» to select 12Vdc or 24Vdc supply to your magnetic locks. 12Vdc TIME RELAY FOR S (REF: TPV) Important: When using a timer in circuit, please make note of the voltage used and ensure the timer can operate at the same voltage (example shows TPV). Adjustable timer (0 to 20 seconds) 24Vdc Voltage 12Vdc or 24Vdc Access Control Unit Exit Button N 1 -Way Terminal Strip non monitored version + 12Vdc or 24Vdc positive * - 12Vdc or 24Vdc negative * 12Vdc 24Vdc N 2 * Voltage: 12Vdc or 24Vdc. Place the «jumpers» to select 12Vdc or 24Vdc supply to your magnetic locks RANGE 2 x 300KG magnetic locks Example N 3: Access Control + Exit Button Exit Button Access Control Unit N 1 24 V DC Input voltage: 48 V DC* N 2 RANGE 2 x 300KG magnetic locks Input voltage: 48 VDC. Magnetic locks connected in series. 6 7

MANUEL D INSTALLATION MANUEL D INSTALLATION Merci pour l achat de ce produit et pour la confiance que vous accordez à notre entreprise. 1] PRÉSTATION DU PRODUIT NFS 61-937. Esthétique. Installation sur tout type de porte (huisserie métallique, bois et verre). Idéal pour les rénovations. Profils pré-percés (réglables). Ventouses avec bornier de raccordement pré-installées sur le poteau technique. Largeur recouvrant les anciennes installations. Passage des câbles facilité grâce au bossage central à l arrière du poteau technique (support des ventouses). Capot de recouvrement du poteau technique après montage. Options : rehausses en aluminium, moulures en aluminium, pose sur porte en verre (Réf : UBK2), teinte RAL, signal NO/NF, Coupe. Force du bandeau : 2 x 300 kg, Dimensions (L x l x P) : - = 92 x 10 x 62 mm - STD = 2190 x 10 x 63 mm, - = 200 x 10 x 63 mm. Poteau technique sur le dormant prévu pour l installation des ventouses. Poignée bandeau sur l ouvrant pour l installation des contre-plaques. Bouchons ABS pour extrémités bandeaux et poteau technique. Alimentation : 12/24/48 V DC. Consommation : - 12 V DC = 00 ma (par ventouses), - 24 V DC = 20 ma (par ventouses), - 48 V DC = 20 ma (pour les 2 ventouses). DEEE Certification CE -20 C à +70 C 63,2 ALMA 60 30,9 28,6 2,3 DORMANT OUVRANT Alimentations préconisées ARD24 2,3 REO 8,8 7,7 DORMANT BS602 BS24 10 8,8 30,9 28,6 REO 37 ALMA 63,2 60 TEMPS DE POSE 7,7 OUVRANT HAUTE RÉSISTANCE AU VANDALISME 37 10 Détail produits Ventouse(s) 300 Kg avec Contreplaque(s) Support mural avec Capot Poignée bandeau avec Cache vis 2] RAPPELS ET RECOMMANDATIONS Alimentations préconisées Le bandeau est conçu pour des ventouses ayant une force de retenue chacune de 400 Kg, alimentées sous 12 V DC ou 24 V DC. Prévoir une alimentation suivant le branchement choisi. L arrivée de courant se fait coté fixe ou semi-fixe à l aide d un flexible si nécessaire. Il existe deux alimentations adaptées pour le (avec 2 ventouses) : - BS602 ou ARD2/12 en 12 V DC - ADC24, AS6 ou BS24 en 24 V DC. Câblage Prévoir du fil 9/10 souple. Nous préconisons une distance maximun de 10 mètres, entre la ventouse et son alimentation. Si cette distance est supérieure, prévoir le câble nécessaire à l installation. 200 mm STD 2190 mm 92 mm Profil poignée avec bouchons Profil cache-vis 200 MM STD 2190 MM 92 MM 2 2 2 1 1 1 1 1 1 Bouchons Poignée bandeau 2 2 2 Bouchons Support mural 2 2 2 Possibilité de teinte RAL (option) Coupe sur-mesure (option) - 3 ou 4 ventouses (option) - - Signal (option) - 3] ÉLÉMTS FOURNIS Capot pour support mural Conseils d utilisation Le bandeau s installe sur des portes en tirant et affleurantes à un ou deux vantaux (service/ semi-fixe). Il se pose sur des portes parfaitement alignées, dans le cas contraire, il faut prévoir une cale (Réf : REO). Vous pouvez également renforcer votre porte avec le profil renfort (Ref: PRP800) et cacher votre installation électrique avec le passecâble (Ref: ALMA). Rappel Les ventouses sont déjà montées sur le support mural. La poignée bandeau est équipée en série des contreplaques et des bouchons à chaque extrémité. Poignée () Vous devez impérativement fixer la poignée plastique avec les deux vis dédiées fournies avec le produit. Profil support mural Bouchons casquette Poignée Kit visserie 1 1 1 1 2 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 2-1 1 - Notice 8 9

MANUEL D INSTALLATION MANUEL D INSTALLATION 4] MONTAGE 1 2 3 Positionnez le support mural avec ses ventouses sur le fixe ou semi fixe. Prenez les marques dans les trous oblongs horizontaux et verticaux et percez la surface du vantail au niveau des marques. Prévoyez les sorties des câbles grâce au bossage central à l arrière du support mural et en vous aidant du schéma de câblage des ventouses (page suivante). Vissez le support mural et fixez les bouchons à chaque extrémité du profil à l aide des vis auto-perçeuses à tête bombée (fournies). Positionnez le capot sur le support mural et emboitez-le dans son logement. Pour le bandeau, même procédure, installez le cache vis dans sa charnière et emboitez-le dans son logement. Positionnez la poignée bandeau munie de ses contreplaques sur l ouvrant. Prenez les marques dans les trous oblongs horizontaux et verticaux pour fixer la poignée bandeau. Percer la surface de la porte au niveau des marques réalisées. Placez et vissez provisoirement la poignée afin de laisser un léger espace qui vous permettra d effectuer le réglage final de l ensemble. Fermez la porte, vérifiez que les ventouses sont bien positionnées face à leur contreplaques puis fixez définitivement la poignée bandeau. Présenter les cache-vis et les clipser dans le profilé pour finaliser l installation. Positionnez le support mural avec ses ventouses sur le fixe ou semi fixe. Prenez les marques dans les trous oblongs horizontaux et verticaux et percez la surface du vantail au niveau des marques. Prévoyez les sorties des câbles grâce au bossage central à l arrière du support mural et en vous aidant du schéma de câblage des ventouses (page suivante). Vissez le support mural et fixez les bouchons à chaque extrémité du profil à l aide des vis auto-perçeuses à tête bombée fournies. Positionnez le capot sur le support mural et emboitez-le dans son logement. Pour le bandeau, même procédure, installez le cache vis dans sa charnière et emboitez-le dans son logement. Positionnez la poignée bandeau munie de ses contreplaques sur l ouvrant. Prenez les marques dans les trous oblongs horizontaux et verticaux pour fixer la poignée bandeau. Percer la surface de la porte au niveau des marques réalisées. Placez et vissez provisoirement la poignée afin de laisser un léger espace qui vous permettra d effectuer le réglage final de l ensemble. Fermez la porte, vérifiez que les ventouses sont bien positionnées face à leur contreplaques puis fixez définitivement la poignée bandeau. Coupez le cache vis en deux parties distinctes de manière à pouvoir insérer la poignée (encombrement environ 20 mm). Vérifiez que la poignée est située à une hauteur accaptable du sol pour en faciliter l usage. Présenter les cache-vis et les clipser dans le profilé puis placez la poignée. Pour garantir la bonne tenue de la poignée dans le temps, il est impératif de fixer la poignée avec les deux vis fournies à cet effet. 10 11

MANUEL D INSTALLATION MANUEL D INSTALLATION ] SCHÉMAS DE RACCORDEMT 12 V DC 24 V DC 6] NOTES Montage N 1 : Bouton poussoir intérieur (+ Carte TPV en option) + Alimentation 12 V ou 24 V DC * - Alimentation 12 V ou 24V DC * Alimentation 12 V ou 24 V DC Bouton poussoir (NO/NF) intérieur GAMME Ventouse 2 x 300 KG VTOUSE N 1 VTOUSE N 2 * Alimentation : 12 V DC ou 24 V DC. En fonction du placement des cavaliers vous alimentez votre ventouse en 12 V DC ou en 24 V DC. OPTIONS BORNIER POINTS (VTOUSE) + Alimentation 12 V ou 24 V DC * - Alimentation 12 V ou 24V DC * NC Contact «Normalement Fermé» COM Commun NO Contact «Normalement Ouvert» * Alimentation : 12 V DC ou 24 V DC. En fonction du placement des cavaliers vous alimentez votre ventouse en 12 V DC ou en 24 V DC. COMMANDE TEMPORISÉE PAR TPV Important :Lorsque la ventouse est équipée d un bornier, il est impératif d enlever les deux cavaliers du TPV. 12 V DC 24 V DC Réglage de la temporisation (de 0 à 20 secondes) Montage N 2 : Contrôle d accès + Bouton poussoir intérieur Alimentation 12 V ou 24 V DC Contrôle d accès extérieur (NF) Temporisé BP (NF) intérieur VTOUSE N 1 12 V DC 24 V DC Bornier points (ventouse) + Alimentation 12 V ou 24 V DC * - Alimentation 12 V ou 24V DC * VTOUSE N 2 * Alimentation : 12 V DC ou 24 V DC. En fonction du placement des cavaliers vous alimentez votre ventouse en 12 V DC ou en 24 V DC. GAMME Ventouse 2 x 300 KG Montage N 3 : Contrôle d accès + Bouton poussoir intérieur Contrôle d accès extérieur (NF) Temporisé BP (NF) intérieur VTOUSE N 1 24 V DC Alimentation 48 V DC* VTOUSE N 2 GAMME Ventouse 2 x 300 KG Alimentation : 48 V DC. Ventouses raccordées en série. 12 13

Reference : G03010387V0 Extranet : EXE-_IM --P300RP-P600RP CMYK A - 03 *G03010387V0* Group ANCE (Headquarter/Siège social) Phone: +33 (0)1 48 91 01 02 Fax: +33 (0)1 48 91 21 21 ANCE + EXPORT Phone: +33 (0)1 48 91 01 02 Fax: +33 (0)1 48 91 21 21 AMERICAS [CANADA - USA] Phone: +1 (40) 682 794 Fax: +1 (40) 682 990 BELUX [BELGIUM - NETHERLAND - LUXEMBOURG] Phone: +32 (0) 6 73 93 00 Fax: +32 (0) 6 73 93 0 SUISSE Phone: +41 (0)21 882 18 41 Fax: +41 (0)21 882 18 42 CHINA Phone: +86 (0)10 6241416 Fax: +86 (0)10 6241419 IBÉRICA [SPAIN - PORTUGAL] Phone: +34 (0)93 390 966 Fax: +34 (0)93 390 970 ITALIA Phone: +39 0321 90 73 Fax: +39 33 127 89 96 MAROC Phone: +212 (0) 22 48 09 40 Fax: +212 (0) 22 48 34 69 SWED [SWED - DMARK - NORWAY - FINLAND] Phone: +46 (0)31 760 19 30 Fax: +46 (0)31 748 09 30 UK [UNITED KINGDOM - IRELAND] Phone: +44 (0)1628 31300 Fax: +44 (0)1628 31003 Toutes les informations mentionnées à titre indicatif sur le présent document (photos, dessins, caractéristiques techniques et dimensions) peuvent varier et sont susceptibles de modifications sans notification préalable. The installer s choice