Un choix rationnel Smart solution



Documents pareils
anthogyr SOMMAIRE CONTENTS 1. SYSTÈME D IMPLANTS OSSFIT / THE OSSFIT IMPLANT SYSTEM 2. GAMME D IMPLANTS OSSFIT / THE RANGE OF OSSFIT IMPLANTS

L. Obert, T. Lascar, A. Adam

Instructions Mozilla Thunderbird Page 1

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

APPENDIX 6 BONUS RING FORMAT

Exemple PLS avec SAS

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

Natixis Asset Management Response to the European Commission Green Paper on shadow banking

Le No.1 de l économie d énergie pour patinoires.

Improving the breakdown of the Central Credit Register data by category of enterprises

Guide d installation Deco Drain inc. DD200

COUNCIL OF THE EUROPEAN UNION. Brussels, 18 September 2008 (19.09) (OR. fr) 13156/08 LIMITE PI 53

Monitor LRD. Table des matières

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Nouveautés printemps 2013

Forthcoming Database

Règlement relatif à l examen fait conformément à la Déclaration canadienne des droits. Canadian Bill of Rights Examination Regulations CODIFICATION

Embases pour raccordement G1/8 - G1/4

Gestion des prestations Volontaire

CLIM/GTP/27/8 ANNEX III/ANNEXE III. Category 1 New indications/ 1 re catégorie Nouvelles indications

1.The pronouns me, te, nous, and vous are object pronouns.

ONTARIO Court File Number. Form 17E: Trial Management Conference Brief. Date of trial management conference. Name of party filing this brief

INSTITUT MARITIME DE PREVENTION. For improvement in health and security at work. Created in 1992 Under the aegis of State and the ENIM

Lavatory Faucet. Instruction Manual. Questions?

DOCUMENTATION - FRANCAIS... 2

Contents Windows

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

Comprendre l impact de l utilisation des réseaux sociaux en entreprise SYNTHESE DES RESULTATS : EUROPE ET FRANCE

CONVENTION DE STAGE TYPE STANDART TRAINING CONTRACT

DOCUMENTATION - FRANCAIS... 2

GASKET FOR TONER COLLECTION BOTTLE

Fabricant. 2 terminals

CLASSIFICATION REPORT OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2007

CLASSIFICATION REPORT OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2007

Contrôle d'accès Access control. Notice technique / Technical Manual

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Face Recognition Performance: Man vs. Machine

Tex: The book of which I'm the author is an historical novel.

Editing and managing Systems engineering processes at Snecma

INDIVIDUALS AND LEGAL ENTITIES: If the dividends have not been paid yet, you may be eligible for the simplified procedure.

LE FORMAT DES RAPPORTS DU PERSONNEL DES COMMISSIONS DE DISTRICT D AMENAGEMENT FORMAT OF DISTRICT PLANNING COMMISSION STAFF REPORTS

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

ETABLISSEMENT D ENSEIGNEMENT OU ORGANISME DE FORMATION / UNIVERSITY OR COLLEGE:

RÉSUMÉ DE THÈSE. L implantation des systèmes d'information (SI) organisationnels demeure une tâche difficile

Une avancée majeure dans le domaine de l implantologie. Roxolid SLActive Moins invasif pour de nouveaux standards

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

Archived Content. Contenu archivé

Mon Service Public - Case study and Mapping to SAML/Liberty specifications. Gaël Gourmelen - France Telecom 23/04/2007

FÉDÉRATION INTERNATIONALE DE NATATION Diving

BNP Paribas Personal Finance

Credit Note and Debit Note Information (GST/ HST) Regulations

Positionnement de l implant

de stabilisation financière

QUESTIONNAIRE DESTINE AUX VETERINAIRES ET AUX RESPONSABLES DE CLINIQUE VETERINAIRES

Bourses d excellence pour les masters orientés vers la recherche

FOURTH SESSION : "MRP & CRP"

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

ADHEFILM : tronçonnage. ADHEFILM : cutting off. ADHECAL : fabrication. ADHECAL : manufacturing.

Cedric Dumoulin (C) The Java EE 7 Tutorial

Notice Technique / Technical Manual

UNIVERSITY OF MALTA FACULTY OF ARTS. French as Main Area in an ordinary Bachelor s Degree

Paxton. ins Net2 desktop reader USB

Lesson Plan Physical Descriptions. belle vieille grande petite grosse laide mignonne jolie. beau vieux grand petit gros laid mignon

Scénarios économiques en assurance

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN 61303:1997

Loi sur la Semaine nationale du don de sang. National Blood Donor Week Act CODIFICATION CONSOLIDATION. S.C. 2008, c. 4 L.C. 2008, ch.

Laboratory accredited by the French Home Office (official gazette date February 5 th, 1959, modified) Valid five years from August 27 th, 2013

Folio Case User s Guide

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

AUDIT COMMITTEE: TERMS OF REFERENCE

MANAGEMENT SOFTWARE FOR STEEL CONSTRUCTION

WEB page builder and server for SCADA applications usable from a WEB navigator

Présentation par François Keller Fondateur et président de l Institut suisse de brainworking et M. Enga Luye, CEO Belair Biotech

IPSAS 32 «Service concession arrangements» (SCA) Marie-Pierre Cordier Baudouin Griton, IPSAS Board

NOM ENTREPRISE. Document : Plan Qualité Spécifique du Projet / Project Specific Quality Plan

Application Form/ Formulaire de demande

Frequently Asked Questions

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Institut français des sciences et technologies des transports, de l aménagement

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

sur le réseau de distribution

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Quatre axes au service de la performance et des mutations Four lines serve the performance and changes

FICHE D INSCRIPTION ET FICHE D INFORMATION MEDICALE POUR ELEVES LYCEE FRANÇAIS INTERNATIONAL

Interest Rate for Customs Purposes Regulations. Règlement sur le taux d intérêt aux fins des douanes CONSOLIDATION CODIFICATION

GAME CONTENTS CONTENU DU JEU OBJECT OF THE GAME BUT DU JEU

Stérilisation / Sterilization

Once the installation is complete, you can delete the temporary Zip files..

RISK-BASED TRANSPORTATION PLANNING PRACTICE: OVERALL METIIODOLOGY AND A CASE EXAMPLE"' RESUME

Consultants en coûts - Cost Consultants

This is a preview - click here to buy the full publication NORME INTERNATIONALE INTERNATIONAL STAN DARD. Telecontrol equipment and systems

IDENTITÉ DE L ÉTUDIANT / APPLICANT INFORMATION

INFORMATION DE BASE SUR LES PROCÉDURES CHIRURGICALES. Straumann Dental Implant System

How to Login to Career Page

Transplantation pulmonaire et mucoviscidose. Optimiser la prise en charge médicale

Transcription:

D E N T A L C A R E B Y N A T U R E

Un choix rationnel Smart solution

Le système Anthofit / The Anthofit system 2 connexions prothétiques / 2 prosthetic connexions Octogone Interne (OI) / Internal Octagon (OI) Trois diamètres d implants et trois embases prothétiques Three diameters of implant and three prosthetic platforms Ø 3.5 mm Ø 4.0 mm Ø 5.0 mm Titane médical grade II / Medical titanium grade II Disponible en version Straight (cylindrique) ou conique (tapered) Available as a straight or as a tapered version Hexagone Externe (HE) / External Hexagon (HE) 4 diamètres d implant et 2 plateformes prothétiques 4 diameters of implant and 2 prosthetic platforms R Ø prothétique 4.1 mm Regular communes aux implants Ø 3.5, 3.75 et 4 mm 4.1 mm Regular prosthetic Ø identical for implants Ø 3.5, 3.75 and 4 mm L Ø prothétique 5 mm Large propre à l implant Ø 5 mm 5 mm Large prosthetic Ø for implant Ø 5 mm Titane médical grade II / Medical titanium grade II Implant auto-taraudant cylindrique Straight self-tapping implant Ø 4.1 mm Ø 5.0 mm

Nouveau! 2 niveaux de sablage / New! 2 levels of sandblasting Les implants de la gamme Anthofit OI tapered et Anthofit OI straight sont disponibles en deux versions. Anthofit OI tapered and Anthofit OI straight are available in 2 versions. Dans sa version Full BCP, l implant présente un col sablé qui optimise l ancrage osseux au niveau coronaire. Un micro-col lisse sécuritaire (minimum) de hauteur 0,4 mm est maintenu afin d anticiper les résorptions osseuses (+/- 0,5 mm) généralement rapportées sous l interface prothétique des implants juxta-crestaux. Ce micro-col permet également d optimiser la qualité du joint prothétique et de prémunir la restauration prothétique contre le développement d une flore bactérienne à ce niveau. Cliniquement cet implant est idéal pour les cas à visée esthétique lorsque l épaisseur de muqueuse attachée est suffisante (+/- 2mm) ou a été préalablement augmentée par greffe. Full BCP version: the implant neck is sandblasted in order to enhance the crestal bone anchorage. A micro smooth surface collar of 0.4mm height has been maintained in order to anticipate bone absorptions (+/- 0.5mm) generally reported under the prosthetic interface in case of juxta-crestal positionnings of implants. The micro smooth surface collar also contributes to the quality of the prosthetic joint and prevents the restauration from the development of bacterial flora. Clinically speaking, the Full BCP version is ideal for aesthetic cases where mucosa is sufficient (+/- 2mm) or if it has been previously grafted. Anthofit Full BCP Optimal Bone Anchorage Dans sa version classique, l implant présente un col lisse de hauteur 1,5 mm. La hauteur d enfouissement de l implant peut être adaptée selon les situations cliniques afin de décaler l interface prothétique coronairement et de réduire le niveau d invasivité du joint prothétique. Cet implant polyvalent est utilisable dans l ensemble des cas. Il est particulièrement intéressant à utiliser lorsque l irrégularité des crêtes osseuses est importante ou lorsque le sujet présente des antécédents parodontaux. In its classical version, the implant has a smooth surface collar of 1.5mm. The burying depth of the implant may be adapted according to the clinical cases so as to move the prosthetic interface above the bone crest and thus reduce the invasivity of the prosthetic interface. This polyvalent implant can be used in any cases. But it can be mostly used when bone crests are irregular or when the patient presents periodontal diseases. Countersink HE Anthofit BCP

Etat de surface ostéoconducteur Osseo-conductor quality surface L état de surface implantaire est un des facteurs influençant l obtention de l ostéointégration. A ce sujet, l ensemble des études sur la compréhension du processus de cicatrisation est unanime sur la supériorité des implants à surfaces rugueuses par rapport aux implants à surfaces lisses. Les études comparatives rapportent, à différents intervalles de temps post-implantation, des taux d interface os-implant ainsi que des couples d arrachement supérieurs lorsque l état de surface présente une topographie irrégulière. The implant s surface quality is one of the factors influencing the osseo-integration. On this subject, the majority of the studies about the comprehension of the healing process is unanimous on the superiority of the implants with rough surfaces compared to the implants with smooth surfaces. At various intervals of post-implantation time, comparative studies conclude that the rates of interface bone-implant as well as the couples of extraction are higher when the surface quality presents an irregular topography. Média Ultra-Propre Utra-Clean Media La rugosité de surface des implants Anthofit est obtenue par sablage au BCP (Biphasic Calcium Phosphate). Le caractère bio-compatible et résorbable de ce média permet de garantir l obtention d un état de surface ultra-propre qui ne dénature pas la couche de TiO2 pendant la phase de traitement industriel. Salgado et Coll. 1ont montré que le sablage BCP ne présentait pas de résidu et qu aucune trace d acide n était détectée par diffraction X après traitement, contrairement aux médias conventionnels, comme l alumine et la silice, dont les traces sont cytotoxiques et susceptibles d entraîner des ostéolyses périphériques après implantation. Si toutefois une particule BCP devait persister en surface, le caractère biocompatible de ce média prémunirait l implant contre tout risque de défaut d ancrage osseux. The roughness of the Anthofit implant surface is obtained by BCP (Biphasic Calcium Phosphate). The biocompatibility and resorbability features of this media guarantee an ultra-clean surface treatment which does not have any incidence on the TiO2 layer during the following industrial treatment phases. Salgado and Coll. 1have shown that BCP sanding does not have any residue and that no traces of acid were detected by X diffraction after treatment, as opposed to the more traditional media such as alumina and silicon whose residues are known to be cytotoxic and may lead to peripheral osteolysis post implant placement. If however there was a chance that a BCP particle remained on the treated surface, the biocompatibility feature of this media will protect the implant against any risk of lack of bone anchorage. L intégralité de la gamme Anthofit bénéficie du traitement BCP The complete range of the Anthofit implant line is BCP treated 8 Grossissement x 2500 Magnification x 2500

Plus de mouillabilité Greater humidity Plus une surface est mouillable (ou hydrophile), plus la surface d exposition sera irriguée par l afflux sanguin et donc favorable à l adhésion cellulaire dans la phase initiale de cicatrisation. Les valeurs des énergies de surface mesurées avec un goniomètre et trois solutions différents (eau, iodométhane et formamide) sur des implants sablés au BCP sont celles nécessaires pour l obtention d une bonne adhésion cellulaire. The more a surface can be made humid (wet), the greater will be the surface of contact toward the influx of blood and that will lead to cell anchorage during the initial healing phase. Values of surface energies measured by a goniometer and three differents s(water, iodine methane and formamide) on BCP sand-blasted implants is to be found between 45 and 54 mj/sqm, which is the necessary range to obtain satisfactory cell anchorage. Efficacité prouvée Proven efficiency In vivo, des surfaces sablées BCP ont été comparées à des surfaces lisses ou sablées avec de l alumine, dans des épiphyses fémorales de rat. Les résultats montrent une ostéogénèse de contact avec les surfaces sablées BCP, contrairement aux témoins avec des surfaces lisses ou sablés alumines, qui présentaient une interface fibreuse sans ostéogénèse de contact. Les analyses histologiques de Paolo Trisi et Coll.2 ont révélé que l interface os-implant moyenne est significativement plus importante avec une surface traitée par sablage BCP (73,31% ± 17,76%) qu avec les surfaces lisses (38,01% ± 19,32%), quelle que soit la qualité de l os. Sanz et Coll.3 ont implanté chez des lapins des vis de titane traitées en surface par un sablage BCP. Ils ont observé un excellent contact entre l os et l implant et surtout l absence de tissus fibreux. Enfin, dans une étude menée dans le cadre de l INSERM, Goyenvalle 4 démontre que les surfaces sablées à partir du BCP permettent d obtenir un état de surface rugueux permettant une ostéo-intégration rapide et efficace. In vivo, BCP sand-blasted surfaces have been compared with non-treated or alumina-treated ones in femoral epiphysis of rats. Results show an osteogenesis of contact with BCP treated surfaces as opposed to the non-treated or alumina-treated ones which showed a fibrous interface with osteogenesis of contact. Histological analysis by Paolo Trisi et al2. has shown that the average bone-implant interface is significantly more important with a surface treated by BCP (73.31% ± 17.76%) than with a machine-made surface (38.01% ± 19.32%), independently from bone quality. Sanz et al3. placed BCP surface-treated titanium screws on rabbits. They observed excellent bone-implant contact and furthermore the absence of fibrous tissues. Finally, in a study completed with the INSERM, Goyenvall confirms the titanium surfaces blasted with calcium phosphate ceramics improve bone ingrowth. 1. Salgado T, Legeros JP, Wang J. Effect of alumina and apatitic abrasives on Ti alloy substances. Bioceramics 1998 ; 11: 683-686 2. Tristi P et al. Contact osseux avec des implants comportant une face usinée et une face MTX dans les sinus greffés. Parosont.Dent.2001 ; 10 : 126-131 3. Sanz A, Oyarzun A, Todisco M. Contact osseux avec des implants comportant une face usinée et une face MTX dans les sinus greffés. Parodont. Dent. Res. 2003 4. Goyenvalle E. Calcium Phosphate Ceramic blasting on titanium surface improve bone ingrowth. 2007 INSERM

Le forage terminal / Final drilling Les gammes Anthofit OI & HE straight Anthofit OI & HE straight implant ranges En protocole standard, les forets terminaux des gammes Anthofit OI straight et Anthofit HE straight présentent un code couleur correspondant à chaque diamètre d implant. In standard protocol, the final drills of the Anthofit OI straight range and Anthofit HE straight range propose a color code matching with each implant s diameter. Forets hélicoïdaux Twist drills NOUVEAU! NEW! NOUVEAU! NEW! NOUVEAU! NEW! OI HE HE OI HE OI HE Ø 3,5 mm Ø 3,75 mm Ø 4,0 mm Ø 5,0 mm Option : en fonction de la densité osseuse, il est possible d opter pour un alésage terminal sur-calibré ou sous-calibré de +/- 0.25 mm par rapport au protocol standard. Option: depending to the osseous density, it is possible to choose a final drilling over- or under-calibrated of +/- 0.25 mm compared to standard protocol. Implant Ø 3,5 mm Implant Ø 3,75 mm Implant Ø 4,0 mm Implant Ø 5,0 mm calibrage standard / standard calibration Ø 3,0 mm Ø 3,25 mm Ø 3,5 mm Ø 4,5 mm Os dur Hard bone Os tendre Soft bone Os dur Hard bone Os tendre Soft bone Os dur Hard bone Os tendre Soft bone Os dur Hard bone Os tendre Soft bone Ø 3,25 mm Ø 2,75 mm Ø 3,50 mm Ø 3,0 mm Ø 3,75 mm Ø 3,25 mm Ø 4,75 mm Ø 4,25 mm

La gamme Anthofit OI tapered / The Anthofit OI tapered range Les forets terminaux de la gamme Anthofit OI tapered comprennent un code couleur correspondant à chaque diamètre d implant. Un foret conique est associé à chaque taille d implant. The final drills of the Anthofit OI tapered range include a color code corresponding to each diameter of implant. A conical drill is associated to each size of implant. Forets lames Blade drills NOUVEAU! NEW! NOUVEAU! NEW! NOUVEAU! NEW! Ø 3,5 mm Ø 4,0 mm Ø 5,0 mm Les gammes prothétiques / The prosthetic ranges Anthofit OI tapered conique Anthofit OI straight cylindrique Anthofit HE straight cylindrique Gamme prothétique OI commune Common OI Prosthetic range Gamme prothétique HE spécifique Specific HE Prosthetic Range Clés de vissage prothétique communes / Common prosthetic tightening wrenches

TiNplus, moignon Titane / TiNplus, Titanium abutment Le moignon TiN-plus est en alliage de titane. Il est recouvert d un revêtement TiN bio-compatible dont la teinte permet d atténuer les reflets bleutés susceptibles de transparaître au travers des parodontes fins. Le chanfrein biseauté de la collerette favorise un meilleur écoulement du ciment et le congé rayonné rend ce moignon aisément retouchable en hauteur pour créer des profils anatomiques personnalisés. The TiN-plus abutment is a titanium alloy-based abutment. It is covered with a bio-compatible TiN coating which diminishes grey shading appearance through thin gingiva tissue. The chamfered edge of the collar gives way to a better cement spreading while the curved upper shape of the abutment allows for easy length reworks in order to create custom-made anatomical profiles. Associé aux chapes de sur-coulés calcinables proposées par le système Anthofit, le TiN-plus est la garantie d une finition parfaite du rebord marginal de la couronne. Together with the overcastable preparation copings proposed by the Anthofit system, the TiN-plus guarantees an excellent finishing of the marginal crown edge Vis DLC / DLC screw «Diamond Like Carbon» Afin de parer aux dévissages intempestifs, les vis de fixation de prothèse Anthofit sont en alliage de titane revêtu d un traitement carbone amorphe. Ce dernier permet d optimiser l effort de tension de la vis qui agit directement sur le serrage des composants et leur stabilité dans le temps. Le gain en tension pour un couple donné est évalué à + 40%. In order to prevent unexpected screw loosenings, the titanium alloy-based Anthofit abutment fixing screws are covered with an amorphous carbon coating. It allows, for a given torque, to optimise the screw s tightening effort, a feature which plays a direct role on the tightening of the different components and their long standing stability. The gain in tension for a given torque is assessed as being of +40%. Test : effort de tension pour un vissage à 35 N.cm Test : tightening effort at 35 N.cm Vis Titane Vis DLC Effort de tension Tightening effort

Gestion du profil d émergence / Management of the emergence profile 66 90 Les vis de cicatrisation et transferts sont profilés en adéquation avec les moignons prothétiques de la gamme. Pour une gestion parfaite du profile d émergence lors des étapes de laboratoire, il est impératif d utiliser les transferts d empreintes dont le profil correspond à celui préfiguré par la vis de cicatrisation. The healing screws and transfers are shaped to match with the prosthetic abutments of the range. For a perfect management of the emergence profile during the laboratory steps, it is imperative to use the impression transfers with the profile corresponding to the one prefigured by the healing screw. La connexion Octogone Interne OI / The Internal Octagon OI connexion La connexion OI (octogone interne) est munie d un clip interne qui procure une stabilité primaire du moignon lors de la pose en bouche, avant le vissage. Le «clic» d emboîtement garantit le bon positionnement du moignon. The OI connection (Internal Octagon) offers an internal groove which gives a primary stability of the abutment at the time of the placing in mouth, before tightening. The fitting «click» guarantees the right positioning of the abutment.

Ancillaire chirurgical modulaire / Flexible surgical ancillary Le système Anthofit propose 2 ancillaires complets permettant chacun de travailler avec l un des 3 implants de la gamme. Les instruments sont classés sur des séquenceurs amovibles intercalés verticalement dans la trousse. The Anthofit system proposes 3 full kits, each one allowing to work with one of the three implants in the range. Instruments are classified on easy-to-remove racks placed individually in the surgical kit. Chaque ancillaire est modulable : des kits d évolution sont disponibles séparément afin de pouvoir élargir simplement et économiquement la compatibilité de la trousse à l un ou l autre système d implant de la gamme Anthofit. Each kit is evolutive : some complementing kits are available separately to enable enlarging the compatibility of the tool kit to match with any system of the Anthofit implant range, in a straight, yet economical manner. Trousse modulable Evolutive kit En option, il est également possible de compléter la trousse avec les kits os dur/os tendre. Ces kits regroupent les forets de diamètres intermédiaires au protocole standard, permettant de moduler le diamètre de forage final en adéquation avec la qualité de l os. It is also possible to complete the surgical kit with hard bone/soft bone kits may it be needed. These kits propose drills of intermediate diameters, compared to the standard protocol, making it possible to modulate the final shaft size in accordance with the quality of the bone. Deux alternatives de mini kits réservés aux systèmes Anthofit HE straight et Anthofit OI straight sont également proposées. Ils regroupent l outillage minimum nécessaire à la pose d un de ces implants. (présentation p. 51) Two mini kits alternatives dedicated to the Anthofit HE straight and Anthofit OI straight systems are also proposed. They propose the minimum number of tools necessary to the placing of either connexions of the straight range of implants. (presentation P. 51) 14

Emballage / Packaging L implant, livré stérile, est protégé par un triple emballage. Trois étiquettes de traçabilité accompagnent chaque implant, dont deux sont destinées à être collées sur le dossier patient (original et copie patient). The implant is protected by a triple packaging and is supplied sterile. Three stickers for traceability are provided with each implant, of which two are intended to be used in the patient s file (one staying with the dentist and one for the patient s own use). Symboles utilisés sur les étiquettes / Symbols used on backstickers : STERILE REF Code de commande Part number LOT Lot de fabrication Manufacturing batch R 2 CE Numero de CE / CE number Suivre le mode d emploi See instructions for use Stérilisation aux Rayons Gamma Gamma ray sterilization Anthofit OI tapered Pastille de contrôle de stérilisation Indication dot attesting of a good sterilization Anthofit OI tapered Full BCP Non stérile / Non sterile Anthofit OI straight Ne pas réutiliser / Not to be re-used Anthofit OI straight Full BCP Date de fabrication / Manufacturing date Date de péremption End of use date Anthofit HE straight Système en prise directe / Direct handling L implant peut être vissé manuellement ou directement au contre-angle. The implant can be placed in mouth manually or directly with the contra-angle 15