Anchor system with many kinds of applications, especially for smaller loads Service class 2 galvanized steel Technical approvals ETA-120358; Declarations of Performance: DE-DoP-e12 0358 ETA-120358, UK-DoP-e120358 FEATURES Material Stainless steel screw and plastic expansion part Benefits 8 spreading elements, which during mounting dowel prevents rotation of a nylon plug in the borehole The anchor made of polyamide PA6 that ensures high resistance to weathering APPLICATIONS Header member Concrete Porenbeton Natural stones Brickwork For Use With Concrete and reinforced hollow s Brick full hollow brick Composite materials 15
TECHNICAL DATA Product Dimensions Item Code Frame anchor [ x L0] Countersunk screw [ x Ls] Holes x depth holes [d0 x h1] Max. Fixture Thickness [tfix] Fixture Hole [df] Overall anchor embedment depth - h nom Drive [TORX SW] Screw Total Length [L] Anchor Packaging [Cdt] [pcs] 8-8010 A4 08080A4 8 x 80 6 x 85 8x80 10 - - T-30 6 80 8 50 8-12050 A408120A4 8 x 120 6 x 125 8x80 50 - - T-30 6 120 8 50 10-8515 A410085A4 10 x 85 7 x 90 10x80 15 - - T-40 7 85 10 50 10-10030 A4 10100A410 x 100 7 x 105 10x80 30 - - T-40 7 100 10 50 10-13565 A4 10135A410 x 135 7 x 140 10x80 65 - - T-40 7 135 10 50 10-16090 A4 10160A410 x 160 7 x 165 10x80 90 - - T-40 7 160 10 50 10230A410 x 230 10-230160 A4 7 x 235 10x80 160 - - T-40 7 230 10 50 Recommended loads C2025 (4) Tension [Rds,N] [kn] Brick (5) Masonry Brick C2025 (4) Shear [Rds,V] [kn] Brick (5) Masonry Brick 8-8010 A4 1 0.2 0.2 1 1 0.2 0.2 1 8-12050 A4 1 0.2 0.2 1 1 0.2 0.2 1 10-8515 A4 10-10030 A4 10-13565 A4 10-16090 A4 10-230160 A4 25
1) Operating expenses: they are calculated from data characteristic values in the ETA on which partial safety factors from the ETAG 001 and a part of shares ɣf coefficient = 1.4 are applied. 2) Tensile service charges: these are calculated for the non-reinforced and reinforced standard whose irons are spaced S 15 cm or S 10 cm if their is less than or equal to 10 mm. 3) Shear service charges: Shear service charges are indicated for a single anchor regardless edge distance slab. To shear loads applied near the edge (C 10hef or 60d). The break slab edge should be checked in accordance with ETAG 001, Annex C, Method A. 4) non-cracked : Concrete is considered uncracked when the tension within the is σl + σr equals 0. In the absence of detailed verification σr = 3 N will be taken mm2 (σl matches the pressure inside the resulting from external loads, including anchors loads). 5) hollow cinder: in the case of use on hollow papaign, it is imperative that the ankle through the 2nd cell. For the service charges thereon, please contact our technical service. Recommended capacities - single anchor - no edge distances 8-8010 A4 8-12050 A4 10-8515 A4 10-10030 A4 10-13565 A4 10-16090 A4 10-230160 A4 C2025 Tension - N rec [kn] brick Recommended capacities C2025 Shear - V rec [kn] brick Bending moment - M rec [Nm] 1 0.2 0.2 1 3.8 0.2 0.2 1 6.2 1 0.2 0.2 1 3.8 0.2 0.2 1 6.2 The design capacities have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The design anchor must comply with ETAG020 "Plastic anchors for multiple use in for Non-structural Applications, Annex C". Temperature range: -40 C to +40 C (Max long term temp: +24 C, max short tem temp: +40 C) 35
Design capacities - single anchor - no edge distances 8-8010 A4 8-12050 A4 10-8515 A4 10-10030 A4 10-13565 A4 10-16090 A4 10-230160 A4 C2025 Tension - N Rd [kn] brick Design capacities C2025 Shear - V Rd [kn] brick Bending moment - M Rd [Nm] 1.4 0.3 0.3 1.4 5.3 0.3 0.3 1.4 8.7 1.4 0.3 0.3 1.4 5.3 0.3 0.3 1.4 8.7 The design capacities have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The design anchor must comply with ETAG020 "Plastic anchors for multiple use in for Non-structural Applications, Annex C". Temperature range: -40 C to +40 C (Max long term temp: +24 C, max short tem temp: +40 C) 45
INSTALLATION Installation Cette cheville permet une pose rapide sur et au travers de la pièce à fixer. Les ergots de blocage sur les côtés entraînent un maintien et un verrouillage de forme parfaite pour les matériaux creux et pleins. Percer le trou Dépoussièrer le trou Enfoncer la cheville au travers de la pièce à fixer Visser Installation data Ø drilling [d0] Screw [ds] Collar [dr] Washer [dm] Depth drilling hole [h1] Depth drilling hole [hnom] Min. Member Thickness [hmin] Fixture Hole [df] spacing () [smin] spacing (masonry) [smin] edge distance () [cmin] edge distance (masonry) [cmin] 8-8010 A4 8 6-19 80 70 100-60 250 60 100 8-12050 A4 8 6-19 80 70 100-60 250 60 100 10-8515 A4 10-10030 A4 10-13565 A4 10-16090 A4 10-230160 A4 55