Biosensor Microprobe Arrays for In Vivo Monitoring of Neurotransmitters



Documents pareils
Design and Realization of Fiber. Monitoring Applications

REMOTE DATA ACQUISITION OF EMBEDDED SYSTEMS USING INTERNET TECHNOLOGIES: A ROLE-BASED GENERIC SYSTEM SPECIFICATION

Photoactivatable Probes for Protein Labeling

Macro-to-Microchannel Transition in Two-Phase Flow and Evaporation

An Ontology-Based Approach for Closed-Loop Product Lifecycle Management

Fonctionnalisation de surfaces de carbone nanostructuré et son effet sur la réponse électrochimique

Forthcoming Database

RÉSUMÉ DE THÈSE. L implantation des systèmes d'information (SI) organisationnels demeure une tâche difficile

Quatre axes au service de la performance et des mutations Four lines serve the performance and changes

THÈSE. présentée à TÉLÉCOM PARISTECH. pour obtenir le grade de. DOCTEUR de TÉLÉCOM PARISTECH. Mention Informatique et Réseaux. par.

physicien diplômé EPFZ originaire de France présentée acceptée sur proposition Thèse no. 7178

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Présentation par François Keller Fondateur et président de l Institut suisse de brainworking et M. Enga Luye, CEO Belair Biotech

SMALL CITY COMMERCE (EL PEQUEÑO COMERCIO DE LAS PEQUEÑAS CIUDADES)

Exemple PLS avec SAS

Z-Axis Compliance Device Compliance en z

Les marchés Security La méthode The markets The approach

A METHOD FOR THE DESIGN OF NEURO-FUZZY CONTROLLERS; AN APPLICATION IN ROBOT LEARNING

Analysis of Water Transport in Polymer Electrolyte Fuel Cells using Neutron Imaging

Qualité de la conception de tests logiciels : plate-forme de conception et processus de test

CEPF FINAL PROJECT COMPLETION REPORT

iqtool - Outil e-learning innovateur pour enseigner la Gestion de Qualité au niveau BAC+2

FOUNDATIONS OF SYSTEMS AND PROPERTIES: METHODOLOGICAL SUPPORT FOR MODELING PROPERTIES OF SOFTWARE-INTENSIVE SYSTEMS

Programming Server-Side Web Applications with Object-Oriented PHP NC Group Syllabus. Duration: 75 hours 1-2-2

1. Formation F5 - Local Traffic Manager Configuring (LTM)

Population responses to environmental forcing : approaches to model and monitor habitat characteristics

Scénarios économiques en assurance

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

PIB : Définition : mesure de l activité économique réalisée à l échelle d une nation sur une période donnée.

sur le réseau de distribution

INTRODUCTION : INFORMATIONS CLÉS ET ACTIVITÉS DU HELPDESK REACH&CLP LUXEMBOURG. 31 mars 2015 Laurène Chochois Helpdesk REACH&CLP Luxembourg

Integrated Music Education: Challenges for Teaching and Teacher Training Presentation of a Book Project

COUNCIL OF THE EUROPEAN UNION. Brussels, 18 September 2008 (19.09) (OR. fr) 13156/08 LIMITE PI 53

INSERTION TECHNIQUES FOR JOB SHOP SCHEDULING

REVITALIZING THE RAILWAYS IN AFRICA

Université de XY University of XY. Faculté XY Faculty of XY

Projet de réorganisation des activités de T-Systems France

Archived Content. Contenu archivé

Tier 1 / Tier 2 relations: Are the roles changing?

Cedric Dumoulin (C) The Java EE 7 Tutorial

HSCS 6.4 : mieux appréhender la gestion du stockage en environnement VMware et service de fichiers HNAS Laurent Bartoletti Product Marketing Manager

Modélisation géostatistique des débits le long des cours d eau.

ERA-Net Call Smart Cities. CREM, Martigny, 4 décembre 2014 Andreas Eckmanns, Responsable de la recherche, Office Fédéral de l énergie OFEN

CLIM/GTP/27/8 ANNEX III/ANNEXE III. Category 1 New indications/ 1 re catégorie Nouvelles indications

La Poste choisit l'erp Open Source Compiere

IPSAS 32 «Service concession arrangements» (SCA) Marie-Pierre Cordier Baudouin Griton, IPSAS Board

The UNITECH Advantage. Copyright UNITECH International Society All rights reserved. Page 1

ÉVALUATION DES RÉTROACTIONS DONNÉES PAR UN LOGICIEL D AIDE À L APPRENTISSAGE DE L ÉCRITURE MANUSCRITE

EU- Luxemburg- WHO Universal Health Coverage Partnership:

Préconisations pour une gouvernance efficace de la Manche. Pathways for effective governance of the English Channel

Object Oriented Parallel Discrete Event Simulation: The PROSIT Approach

Les Ontariens rejettent catégoriquement le projet de création d une école afrocentriste

F1 Security Requirement Check List (SRCL)

Cell-Based Deformation Monitoring via 3D Point Clouds

Rôle du sommeil dans la consolidation de la mémoire: un dialogue entre structures cérébrales

AUDIT COMMITTEE: TERMS OF REFERENCE

Les méthodes alternatives de surveillance de la qualité des eaux. Présentation du projet SWIFT-WFD

L. Obert, T. Lascar, A. Adam

Judge Group: P Title: Quel est meilleur: le compost ou le fertilisant chimique? Student(s): Emma O'Shea Grade: 6

Frequently Asked Questions

CONCLUSION. 31 mars 2015 Laurène Chochois Helpdesk REACH&CLP Luxembourg

Revision of hen1317-5: Technical improvements

CLIQUEZ ET MODIFIEZ LE TITRE

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

Possible ECHO Shelter & Settlement Indicators (version 15/05/13) revised by EDB/MP & DH 13/06

NORME INTERNATIONALE INTERNATIONAL STANDARD. Dispositifs à semiconducteurs Dispositifs discrets. Semiconductor devices Discrete devices

Natixis Asset Management Response to the European Commission Green Paper on shadow banking

FOURNIR UN SERVICE DE BASE DE DONNÉES FLEXIBLE. Database as a Service (DBaaS)

NOM ENTREPRISE. Document : Plan Qualité Spécifique du Projet / Project Specific Quality Plan

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Comment le Health 2.0 peut contribuer à l'autonomie éclairée du citoyen. Sarah Cruchet, Célia Boyer, Maria-Ana Simonet et Vincent Baujard

Application Form/ Formulaire de demande

Editing and managing Systems engineering processes at Snecma

Les contraintes de financement des PME en Afrique : le rôle des registres de crédit

Once the installation is complete, you can delete the temporary Zip files..

Rapport de certification

Measurements of B Meson Lifetime Ratios with the LHCb Detector

BILL 203 PROJET DE LOI 203

Rountable conference on the revision of meat inspection Presentation of the outcome of the Lyon conference

Improving the breakdown of the Central Credit Register data by category of enterprises

Plateforme Technologique Innovante. Innovation Center for equipment& materials

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN 61303:1997

Notice Technique / Technical Manual

Lean approach on production lines Oct 9, 2014

Cloud Computing: de la technologie à l usage final. Patrick CRASSON Oracle Thomas RULMONT WDC/CloudSphere Thibault van der Auwermeulen Expopolis

- Couches - Éléments - Domaines - ArchiMate et les techniques du BABOK

ICA Congress, Brisbane 2012 Thème général : Les temps qui changent. La confiance et les archives*

Comprendre l impact de l utilisation des réseaux sociaux en entreprise SYNTHESE DES RESULTATS : EUROPE ET FRANCE

Working Group on Implementation of UNGCP Meeting

RAPID Prenez le contrôle sur vos données

PeTEX Plateforme pour e-learning et expérimentation télémétrique

Introduction à l ISO/IEC 17025:2005

VTP. LAN Switching and Wireless Chapitre 4

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

La solution idéale de personnalisation interactive sur internet

Transcription:

Biosensor Microprobe Arrays for In Vivo Monitoring of Neurotransmitters THÈSE N O 4614 (2010) PRÉSENTÉE LE 11 MARS 2010 À LA FACULTÉ SCIENCES ET TECHNIQUES DE L'INGÉNIEUR LABORATOIRE DE CAPTEURS, ACTUATEURS ET MICROSYSTÈMES SECTION DE MICROTECHNIQUE ÉCOLE POLYTECHNIQUE FÉDÉRALE DE LAUSANNE POUR L'OBTENTION DU GRADE DE DOCTEUR ÈS SCIENCES PAR Olivier FREY acceptée sur proposition du jury: Prof. M. A. Ionescu, président du jury Prof. N. de Rooij, Prof. M. Koudelka-Hep, directeurs de thèse Dr J. W. Dalley, rapporteur Prof. A. Hierlemann, rapporteur Dr P. Ruther, rapporteur Suisse 2010

Abstract Real-time monitoring of neurotransmitters is of utmost importance for understanding the functioning of the brain. Especially L-glutamate and choline play a major role in chemical signalling and are highly involved in cognitive functions such as learning, memory and behaviour. In this thesis, silicon microprobe arrays were realised comprising several microelectrodes with a size of 50 150 µm 2. The microtechnological fabrication process allows an application-tailored design to position the electrodes at defined target regions in the brain. Microprobes with a length up to 8 mm and a cross-section of 40 100 µm 2 have been fabricated allowing minimally invasive implantation at low tissue damage to be achieved. L-glutamate and choline are detected by the amperometric detection of peroxide using the microelectrodes coated with an enzymatic membrane. An array-compatible method for spatially controlled and parallel membrane deposition by electrochemically aided adsorption and chemical co-cross-linking with glutaraldehyde was developed. The enzymatic membrane deposition is followed by electropolymerisation of m-phenylenediamine to deposit a semipermeable membrane rejecting electroactive interferents such as ascorbic acid and dopamine that are endogenously present in the extracellular fluid. The resulting biosensors show adequate characteristics in sensitivity, detection limit as well as functional and storage lifetimes for acute monitoring of the neurotransmitters in brain tissue. The results of an extensive in vitro assessment and in vivo functional tests are presented. In array configuration, the biosensors allow simultaneous multi-site recordings of one analyte from different brain regions or multi-analyte recordings within defined spatial brain areas. Additionally, microchannels were integrated with the biosensor arrays to perform chemical stimulation by the local delivery of neuroactive substances: SU-8 microinjector arrays comprising several microfluidic channels or the direct integration of microchannels into the silicon shaft were realised. Both allow a precise positioning of the fluidic outlet relative to the biosensors and lowvolume injections. The biosensors integrated with the delivery channels enable the bilateral interaction with neuronal tissue on the neurochemical level at required temporal

and spatial resolution. This thesis is a part of the European integrated project NeuroProbes aiming at realising three-dimensional arrays of multi-functional microprobes, assembled in a modular way to perform in vivo electrophysiological and biological measurements. The biosensor is one of the functionalities to be integrated in this platform. The result is a new device for neuroscientists that will allow most complete 3D mapping of neuronal circuitry and relate these complex signalling mechanisms to observable behaviour. Keywords: microprobe, microinjector, enzyme electrode, biosensor, in vivo, choline, glutamate.

Résumé La mesure en temps réelle de neurotransmetteurs est de la plus haute importance pour comprendre le fonctionnement du cerveau. Le L-glutamate et la choline joue un rôle majeur dans la transmission de signaux chimiques et sont fortement impliqués dans les fonctions cognitives telles que l apprentissage, la mémoire et le comportement. Dans cette thèse, une matrice de micropointes en silicium comprenant plusieurs microélectrodes de 50 150 µm 2 fût réalisée. Leur conception sur mesure par des méthodes de microfabrication permet le placement des électrodes dans des régions cibles prédéfinies du cerveau. Des micropointes d une longueur maximale de 8 mm et d une section de 40 100 µm 2 furent fabriquées afin de permettre leur implantation en minimisant les lésions provoquées aux tissus cérébraux. Le L-glutamate et la choline sont mesurés ampérométriquement par détection de peroxyde généré par une membrane enzymatique couvrant les microélectrodes. Une méthode de déposition de membranes par adsorption électrochimique assistée et co-réticulation avec du glutaraldehyde fût développée. Elle est compatible avec la matrice de pointes pour le dépôt localisé et en parallèle. Le dépôt de la membrane enzymatique est suivi par l électro-polymérisation de m- phenylenediamine pour obtenir la déposition d une membrane semi-perméable qui bloque des interférents électroactifs tels que l acide ascorbique et la dopamine, ces derniers étant présent dans le fluide extracellulaire. Les biocapteurs obtenus présentent des caractéristiques adéquates en termes de sensibilités, limite de détection ainsi que de durée de vie de conservation et en opération pour la détection précise des neurotransmetteurs dans les tissus du cerveau. Les résultats d une vaste évaluation in vitro et de tests fonctionnels in vivo sont présentés. En configuration en matrice, les biocapteurs permettent la mesure simultanée d un analyte dans plusieurs régions du cerveau ou de plusieurs analytes dans une zone précise. De plus, des microcanaux furent intégrés dans la matrice de biocapteurs permettant une stimulation chimique par la distribution locale de substance neuroactive: Des micro-injecteurs en SU-8 avec plusieurs canaux microfluidiques

ou l intégration directe des microcanaux dans les pointes en silicium furent réalisés. Les deux solutions permirent un positionnement précis de l extrémité du canal par rapport au biocapteur pour une injection de petits volumes. Les biocapteurs avec les microcanaux intégrés permettent une interaction bilatérale avec le tissu neuronal au niveau neurochimique à la résolution spatiale et temporelle requise. Cette thèse fait partie du projet européen NeuroProbes visant à la réalisation de matrices tridimensionnelles de micropointes multifonctionnelles assemblées de façon modulaire pour des mesures électrophysiologiques et biologiques in vivo. Le biocapteur est l une des fonctionnalités à être intégré dans cette platforme. Le résultat est un nouveau dispositif pour la neuroscience qui permettra une mesure tridimensionnelle fortement avancée des circuits neuronaux et de lier ces mécanismes complexes de transmission à des comportements observables. Mots-clés: micropointe, microinjecteur, electrode enzymatique, biocapteur, in vivo, choline, glutamate.

Contents Abstract Résumé Contents Glossary i iii v ix 1 Introduction 1 1.1 Neural networks in the brain.......................... 3 1.1.1 The neuron................................ 3 1.1.2 The synapse and the role of neurotransmitters............ 4 1.1.3 Neurotransmitter acetylcholine and L-glutamic acid......... 5 1.2 Monitoring neurochemicals........................... 9 1.2.1 Motivation................................ 9 1.2.2 Historical overview state of the art.................. 9 1.2.3 Future prospects............................. 12 1.3 The NeuroProbes project............................. 13 1.3.1 Objectives................................. 13 1.3.2 Relevance of the project......................... 14 1.3.3 Involved partners and their role..................... 15 1.4 Development of the biosensors.......................... 16 1.4.1 Project plan................................ 16 1.4.2 Concept of the NeuroProbes 3D-array................. 17 1.4.3 Structure of the thesis.......................... 20

vi CONTENTS 2 Silicon microprobe arrays 23 2.1 Introduction.................................... 24 2.2 Requirements................................... 28 2.2.1 General aspects.............................. 28 2.2.2 Application-specific........................... 28 2.3 Design....................................... 31 2.3.1 Preliminary tests and first generation microprobes.......... 31 2.3.2 Final microprobe layout......................... 32 2.4 Fabrication.................................... 37 2.5 Results and discussion.............................. 40 2.6 Packaging..................................... 44 2.6.1 Printed circuit board........................... 44 2.6.2 Highly flexible ribbon-cable....................... 45 2.6.3 Reference electrode............................ 45 2.7 Conclusion.................................... 46 3 Biosensor integration 47 3.1 Introduction.................................... 48 3.1.1 Biosensor definition........................... 48 3.1.2 Detection principle the enzyme-electrode.............. 48 3.1.3 Requirements............................... 52 3.1.4 Immobilisation of enzymes........................ 55 3.1.5 Schemes for interference removal.................... 56 3.1.6 Overview on enzyme layer deposition methods............ 58 3.1.7 Electrochemically aided adsorption EAA.............. 66 3.2 Microprobe array functionalisation....................... 70 3.2.1 Chemicals................................. 70 3.2.2 Apparatus................................. 70 3.2.3 Enzyme immobilisation......................... 71 3.2.4 Anti-interference scheme......................... 72 3.3 In vitro calibration set-up............................ 74 3.4 Results and discussion.............................. 75 3.4.1 Membrane deposition general remarks................ 75 3.4.2 Sensor performance........................... 76 3.4.3 Interference rejection........................... 81 3.4.4 Parallel depositions and reproducibility................ 82 3.4.5 Spatial control and cross-talk...................... 82 3.5 Conclusion.................................... 84

CONTENTS vii 4 Liquid delivery 85 4.1 Introduction.................................... 86 4.2 Conventional micropipettes........................... 88 4.2.1 Assembly with silicon microprobes................... 88 4.3 SU-8 microinjectors................................ 90 4.3.1 Motivation and state-of-the art..................... 90 4.3.2 Design................................... 92 4.3.3 Fabrication process............................ 94 4.3.4 Fabrication results............................ 96 4.3.5 Assembly with biosensor microprobes................. 98 4.3.6 Injection tests............................... 99 4.3.7 Discussion................................. 100 4.4 Silicon biosensor microprobe arrays with integrated microfluidic channels. 103 4.4.1 Motivation and state-of-the-art..................... 103 4.4.2 Integration with NeuroProbes designs................. 104 4.4.3 Fabrication and adapted design..................... 105 4.4.4 Packaging................................. 107 4.4.5 Biosensor and liquid delivery testing.................. 109 4.5 Conclusion.................................... 111 5 In vivo measurements 113 5.1 Introduction.................................... 113 5.1.1 Motivation and interest......................... 113 5.1.2 Challenges................................ 114 5.1.3 State of the art.............................. 115 5.2 Materials and methods.............................. 118 5.2.1 Functionalisation procedure and storage................ 118 5.2.2 In vivo criteria.............................. 118 5.2.3 Experimental section........................... 119 5.3 Results and discussion.............................. 121 5.3.1 General remarks............................. 121 5.3.2 Recordings in the prefrontal cortex................... 122 5.3.3 Recordings in the cerebellum...................... 126 5.4 Conclusion.................................... 128

viii CONTENTS 6 Microfluidic approaches 129 6.1 Microfluidic device for membrane deposition.................. 130 6.1.1 Deposition concept............................ 130 6.1.2 Design and fabrication.......................... 131 6.1.3 Set-up................................... 134 6.1.4 Functionalisation............................. 134 6.1.5 Results.................................. 136 6.2 Microfluidic calibration device.......................... 138 6.2.1 Idea and Motivation........................... 138 6.2.2 Design and fabrication.......................... 139 6.2.3 Operation................................. 140 6.2.4 Results.................................. 142 6.3 Microfluidic cartridges Conclusion...................... 144 6.4 On-chip focused dispensing approach...................... 145 6.4.1 Idea and Design............................. 145 6.4.2 Fabrication and functionalisation.................... 146 6.4.3 Results and Discussion.......................... 147 7 Summary and Outlook 149 References 155 Acknowledgements 165 Publications 169 Biography 171