Regulation and governance through performance in the service management contract



Documents pareils
Tier 1 / Tier 2 relations: Are the roles changing?

Le projet WIKIWATER The WIKIWATER project

PRESENTATION. CRM Paris - 19/21 rue Hélène Boucher - ZA Chartres Est - Jardins d'entreprises GELLAINVILLE

JSIam Introduction talk. Philippe Gradt. Grenoble, March 6th 2015

Glossaire : définitions des termes utilisés dans les fiches sur les indicateurs de performance

Nouveautés printemps 2013

La Poste choisit l'erp Open Source Compiere

Préconisations pour une gouvernance efficace de la Manche. Pathways for effective governance of the English Channel

Cliquez pour modifier les styles du texte du masque

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

Scénarios économiques en assurance

F1 Security Requirement Check List (SRCL)

Lean approach on production lines Oct 9, 2014

INDIVIDUALS AND LEGAL ENTITIES: If the dividends have not been paid yet, you may be eligible for the simplified procedure.

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

NOM ENTREPRISE. Document : Plan Qualité Spécifique du Projet / Project Specific Quality Plan

Plateforme Technologique Innovante. Innovation Center for equipment& materials

AUDIT COMMITTEE: TERMS OF REFERENCE

Présentation par François Keller Fondateur et président de l Institut suisse de brainworking et M. Enga Luye, CEO Belair Biotech

CALCUL DE LA CONTRIBUTION - FONDS VERT Budget 2008/2009

Edna Ekhivalak Elias Commissioner of Nunavut Commissaire du Nunavut

MANAGEMENT SOFTWARE FOR STEEL CONSTRUCTION

How to Login to Career Page

PEINTAMELEC Ingénierie

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

The impacts of m-payment on financial services Novembre 2011

Stratégie DataCenters Société Générale Enjeux, objectifs et rôle d un partenaire comme Data4

Borrowing (Property and Casualty Companies and Marine Companies) Regulations

Sagemcom EDI with Suppliers

INSTITUT MARITIME DE PREVENTION. For improvement in health and security at work. Created in 1992 Under the aegis of State and the ENIM

#FeelTheDifference. Nouveau en 2014 : Vos événements dans un lieu unique aux portes de Paris New in 2014 : Your events in an unique venue near Paris

Frequently Asked Questions

Interest Rate for Customs Purposes Regulations. Règlement sur le taux d intérêt aux fins des douanes CONSOLIDATION CODIFICATION

REVITALIZING THE RAILWAYS IN AFRICA

La gestion des risques IT et l audit

Natixis Asset Management Response to the European Commission Green Paper on shadow banking

3 rd ORGANIC PROCESSING CONFERENCE

IPSAS 32 «Service concession arrangements» (SCA) Marie-Pierre Cordier Baudouin Griton, IPSAS Board

RAPID Prenez le contrôle sur vos données

EN UNE PAGE PLAN STRATÉGIQUE

ADHEFILM : tronçonnage. ADHEFILM : cutting off. ADHECAL : fabrication. ADHECAL : manufacturing.

Credit Note and Debit Note Information (GST/ HST) Regulations

France SMS+ MT Premium Description

Manager, Construction and Engineering Procurement. Please apply through AECL website:

Institut français des sciences et technologies des transports, de l aménagement

SEMINAIRE SAS VISUAL ANALYTICS LAUSANNE, MARCH 18 : JÉRÔME BERTHIER VALERIE AMEEL

SCC / QUANTUM Kickoff 2015 Data Protection Best Practices

Fédération Internationale de Handball. b) Règlement du but

Exemple PLS avec SAS

Le MDM (Master Data Management) Pierre angulaire d'une bonne stratégie de management de l'information

PAR_ _09543_EUR DATE: 17/12/2014. Suite à l'avis PAR_ _08654_EUR

22/09/2014 sur la base de 55,03 euros par action

POLICY: FREE MILK PROGRAM CODE: CS-4

Comprehensive study on Internet related issues / Étude détaillée sur les questions relatives à l Internet. November/Novembre 2014

BASE DE DONNÉES DES ASPECTS SOCIOÉCONOMIQUES EN MÉDITERRANÉE OCCIDENTALE

IPv6: from experimentation to services

Extension fonctionnelle d un CRM. CRM étendu >> Conférence-débat 15 April Club Management des Systèmes d Information de l'iae de Paris Alumni

Cegedim. Half-year results

THE LAW SOCIETY OF UPPER CANADA BY-LAW 19 [HANDLING OF MONEY AND OTHER PROPERTY] MOTION TO BE MOVED AT THE MEETING OF CONVOCATION ON JANUARY 24, 2002

Surveillance de Scripts LUA et de réception d EVENT. avec LoriotPro Extended & Broadcast Edition

Improving the breakdown of the Central Credit Register data by category of enterprises

CEPF FINAL PROJECT COMPLETION REPORT

Le rôle de la DSI avec l audit Interne pour la maîtrise des risques

Mise en place d un système de cabotage maritime au sud ouest de l Ocean Indien. 10 Septembre 2012

SAP SNC (Supply Network Collaboration) Web Package. (Français / English) language. Edition 2013 Mars

Name of document. Audit Report on the CORTE Quality System: confirmation of the certification (October 2011) Prepared by.

Rountable conference on the revision of meat inspection Presentation of the outcome of the Lyon conference

UML : Unified Modeling Language

SMALL CITY COMMERCE (EL PEQUEÑO COMERCIO DE LAS PEQUEÑAS CIUDADES)

staff worldwide years 36b. revenues countries

Bill 69 Projet de loi 69

de stabilisation financière

Consultants en coûts - Cost Consultants

IT Roadmap Powered by Aris IT Architect William Poos, IT Gov Manager at NRB 08 Février 2011

La solution idéale de personnalisation interactive sur internet

IODE Consulting I Intelligence on Demand Slide 1

AXES MANAGEMENT CONSULTING. Le partage des valeurs, la recherche de la performance. Sharing values, improving performance

Loi sur l aide financière à la Banque Commerciale du Canada. Canadian Commercial Bank Financial Assistance Act CODIFICATION CONSOLIDATION

Cloud for Sales Retail Execution Piloter la relation client en temps réel pour doper votre présence en linéaire. SAP Forum, Lausanne Juin 17, 2014

Disclosure on Account Opening by Telephone Request (Retail Associations) Regulations

Règlement sur les baux visés à la Loi no 1 de 1977 portant affectation de crédits. Appropriation Act No. 1, 1977, Leasing Regulations CODIFICATION

Master Développement Durable et Organisations Master s degree in Sustainable Development and Organizations Dossier de candidature Application Form

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

Information Security Management Lifecycle of the supplier s relation

Paxton. ins Net2 desktop reader USB

Agile&:&de&quoi&s agit0il&?&

Pourquoi mesurer l impact? Benoît Fontaine 11/02/2014

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN 61303:1997

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Comprendre l impact de l utilisation des réseaux sociaux en entreprise SYNTHESE DES RESULTATS : EUROPE ET FRANCE

Afin de valider votre inscription merci de bien veiller à :

BELAC 1-04 Rev

INSTRUMENTS DE MESURE SOFTWARE. Management software for remote and/or local monitoring networks

la valorisation des externalités positives des services d eau potable et d assainissement

General Import Permit No. 13 Beef and Veal for Personal Use. Licence générale d importation n O 13 bœuf et veau pour usage personnel CONSOLIDATION

INTERNATIONAL CONSULTANT & SUPPLIERS TO THE WINE & SPIRITS TRADE

L ESPACE À TRAVERS LE REGARD DES FEMMES. European Economic and Social Committee Comité économique et social européen

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

Transcription:

Regulation and governance through performance in the service management contract Agathe Cohen- Syndicat des eaux d'ile-de-france Florence- séminaire du 7 et 8 février 2013

Summary 1- Key figures of SEDIF 2- Scope of the management contract 3- Operator compensation scheme Diagram of operator's remuneration Technical performance indicators Financial performance indicators Performance monitoring 4- Results 2011 2

Key figures SEDIF: Syndicat des Eaux d Ile-de-France Founded in 1923 to produce and deliver drinking water SEDIF today : Covers 149 cities located on the outskirts of Paris Supplies 4 millions customers (almost 40% of Ile de France) Produces 255 millions m 3 /yr (800 000 m 3 distributed/day) Main Assets : 3 water treatment plants on rivers Seine, Marne, Oise (Choisy-le-Roi, Neuilly-sur- Marne, Méry-sur-Oise) 48 relay plants 63 tanks 38 chlorination stations 8 300 kilometres of pipes The price of water: 1.41 excl.taxes/m 3 (January 2011) Previous contract implemented since 1962 A new management contract came into effect on the 1st of January 2011 3

Key figures A public drinking water service for the greater metropolitan Paris area 4

Scope of the management contract Operation, maintenance and monitoring of equipments Customer relationship Implementation of works: Pipes renewal (18 L km/yr), automatic equipments Yearly amount = 21 M excl. taxes 5

Operator compensation scheme Incentive scheme must address various issues: Ensure the private operator bares a part of operational risks Encourage the private operator to improve productivity and service performance Enable the private operator to make profits while minimising potential opportunity costs Ensure legibility and transparency Limit SEDIF exposure to unjustified risks Cour des Comptes (French court of auditors): "contractual obligations must focus more on the goals to reach than on the means to implement; the link between performance and remuneration must be strong" 6

Diagram of operator's remuneration Share paid out regardless of operating income balance (art 42.2 of contract) Remuneration Fixed share minus penalties 2% of yearly retail sales and wholesale water revenue Variable share 1 st part 40% of operating account balance minus fixed share, based on reaching quality target 2 nd part 40% of operating account balance minus fixed share, based on the operator s control over operating cost 3 rd part 20% of operating account balance (when balance positive) minus fixed share Ceiling for operator s remuneration set at 9% of total water sales 7

Financial performance indicators 1) Share of operating account balance if balance positive (3 rd part) 2) Productivity gains assessed w/coefficient k n (2 nd part) k n = k n reflects productivity gains required from operator each year: ( 1 pn ) ( CRCF CFref ) ref + CR CV V V - max. incentive scheme (100% of 40%) if k n < 0.9875 - min. incentive scheme (0% of 40%) if k n > 1.0125 o C n CV ref ref o n 0 8

Diagram of operator's remuneration Share paid out regardless of operating income balance (art 42.2 of contract) Remuneration Fixed share minus penalties 2% of yearly retail sales and wholesale water revenue Variable share 1 st part 40% of operating account balance minus fixed share, based on reaching quality target 2 nd part 40% of operating account balance minus fixed share, based on the operator s control over operating cost 3 rd part 20% of operating account balance (when balance positive) minus fixed share Ceiling for operator s remuneration set at 9% of total water sales 9

Technical performance indicators Set of indicators broken down into 4 categories Number of indicators Number of indicators with an impact on remuneration Customer service 17 16 Technical management 43 18 Sustainable development 24 20 Water quality 52 0 136 indicators with penalties 54 indicators with an impact on the remuneration 10

Technical performance indicators Scale to assess incentive 10 Incentive Penalties 0 Value of the indicator Minimum threshold Maximum threshold 11

Technical performance indicators How to ensure the reliability of the indicator value provided by the operator? A certification of the performance indicator production process must be obtained and maintained by an independent organization. A specific description and definition note is produced for each indicator Permanent access to the operator's information system 12

FICHE DESCRIPTIVE DE L'IP 6 Version 2.1 Date: 17/10/2012 Réf. Nom Différents Noms relevés Thème Dimension Sous-Dimension Rôle Finalité 6-I-C-X-SPDE Rendement du réseau Nom SPDE: rendement du réseau Nom MEDD : rendement du réseau Nom FNCCR: Rendement du réseau de distribution ( P104) Nom IGD: Rendement net d utilisation de la ressource Gestion du service Gestion du réseau SO Contractuel avec intéressement et pénalités Cet indicateur permet de connaître la part des volumes introduits dans le réseau de distribution qui est consommée avec autorisation sur le périmètre du service ou vendue en gros à un autre service d eau potable. Sa valeur et son évolution sont le reflet de la politique de lutte contre les pertes d eau en réseau de distribution. Définition : Il s agit du ratio entre le volume consommé autorisé augmenté des volumes vendus en gros et le volume produit augmenté des volumes achetés en gros. Définition de l'annexe 6bis: Le rendement du réseau est obtenu en faisant le rapport entre, d'une part, le volume consommé autorisé augmenté des volumes vendus à d'autres services publics d'eau potable et, d'autre part, le volume produit augmenté des volumes achetés à d'autres services publics d'eau potable. Le volume consommateurs sans comptage et le volume de service du réseau sont ajoutés au volume comptabilisé pour calculer le volume consommé autorisé. arrêté du 2 mai 2007 Unité Sans dimension (exprimé par un pourcentage) Fréquence de détermination Préciser la fréquence de détermination de l'indicateur ainsi Annuelle. Les volumes pris en compte pour l année n sont ceux déterminés au titre de l année n. que la période sur laquelle les évènements sont pris en compte Lister précisément les données nécessaires Il s'agit des données nécessaires à la production de l indicateur (préciser le nom de chaque type de donnée permettant le calcul) Entité (unité ou cellule) responsable de la production SACE - Unité Coordination de la Distribution des données Personne responsable de la validation des données et P. Thouvenel / D. Kruz / D. Bihel son remplaçant Recoupement(s) effectué(s) pour vérifier la cohérence SO des données Personne responsable de la validation de l'indicateur et G. Bayon / P. Thouvenel son remplaçant Méthode de collecte des données Brève description du processus - Les volumes produits sur 12 mois (365 ou 366 jours) - IP24 - Les volumes achetés en gros (importés) sur 12 mois (365 ou 366 jours) - IP25 - Les volumes vendus en gros (exportés) sur 12 mois (365 ou 366 jours) - IP26 - Les volumes comptabilisés qui sont les volumes consommés issus du relevé des compteurs chez les abonnés et autres usagers équipés de compteurs (particuliers, industriels, services municipaux, fontaines avec compteur, bornes incendie avec compteurs etc..). - IP22 - Les volumes consommateurs sans comptage. Ces volumes sont estimés - - Les volumes de service du réseau. Ces volumes sont estimés - Les volumes consommateurs sans comptage et les volumes de service du réseau constituent l'ip 23 Les données nécessaires au calcul de cet IP sont des indicateurs définis par ailleurs et décrits dans les fiches descriptives correspondantes. Le portail IP calcul l'ip 6 à partir des valeurs de ces IP liés, selon la règle de calcul décrite ci-dessous. Le RVD vérifie la présence de données validées pour les IP 22,23, 24, 25 et 26. Le calcul, fait par le portail IP, a été contrôlé lors de la recette de l'indicateur. Règles de calcul / mesure Application support Détailler les applications support par type de donnée identifiée Règles d'archivage des données d'entrée Rendement = (volume consommé autorisé + volume vendu en gros) / (volume produit + volume acheté en gros) X 100 = ( IP22 + IP23 +IP26 ) / ( IP24 + IP25 ) x 100 avec : volume consommé autorisé = volume comptabilisé + volume consommateurs sans comptage + volume de service du réseau = IP22 + IP 23 volume en m3, IP arrondi au plus près à 2 décimales Portail IP Règles d'archivage des résultats Recommandations pour la maitrise de la qualité de l'indicateur et règles pour l'interprétation Précisions sur les informations non prises en compte et qui pourraient améliorer la fiabilité de l indicateur Règles de consolidation à une échelle supérieure Données contextuelles Précisions éventuelles sur les caractéristiques des mesures/informations, ou sur l indicateur lui-même qui faciliteront la compréhension de son résultat et de son évolution Portail IP SO Bilan des indicateurs FNCCR (ref SEDIF xxi-2b) et bilan réseau (ref SEDIF* XXB-2i) * xx année de l'exercice Les volumes utilisés pour cet indicateur sont les mêmes que ceux utilisés pour l indice linéaire des volumes non comptés et l indice linéaire de pertes en réseau. On se réfèrera aux fiches indicateurs pour la définition précise de tous les volumes utilisés. Seuil de déclenchement des pénalités <88,4% Pénalité 20000 par 0,1 % manquant : pénalité de 20 000 euros si 88,4> IP >=88,3, 40 000 euros si 88,3> IP >=88,2... Objectif >=90% Intéressement 25 Intéressement nombre total de points 150 13

Results 2011 Water sales: 234 M Remuneration: 12.5 M Fixed share: 4.7M Variable share: 7.8M 1st part: 4.8M 2 nd part: 0 M 3rd part: 3M 14

Thank you 15