President Cast Front Insert Model 536CXBI Approved for use with Valor heater 530 & 530 insert models only

Documents pareils
Instructions Mozilla Thunderbird Page 1

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Le No.1 de l économie d énergie pour patinoires.

Folio Case User s Guide

R.V. Table Mounting Instructions

Lavatory Faucet. Instruction Manual. Questions?

Paxton. ins Net2 desktop reader USB

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Application Form/ Formulaire de demande

Monitor LRD. Table des matières

GASKET FOR TONER COLLECTION BOTTLE

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

APPENDIX 6 BONUS RING FORMAT

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

FÉDÉRATION INTERNATIONALE DE NATATION Diving

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Notice Technique / Technical Manual

Guide d installation Deco Drain inc. DD200

Archived Content. Contenu archivé

Once the installation is complete, you can delete the temporary Zip files..

POLICY: FREE MILK PROGRAM CODE: CS-4

Fabricant. 2 terminals

Trim Kit Installation Instruction

Embases pour raccordement G1/8 - G1/4

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

Gestion des prestations Volontaire

Contrôle d'accès Access control. Notice technique / Technical Manual

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

How to Login to Career Page

CLIM/GTP/27/8 ANNEX III/ANNEXE III. Category 1 New indications/ 1 re catégorie Nouvelles indications

Sécurité relative aux sièges auto et aux rehausseurs

FCM 2015 ANNUAL CONFERENCE AND TRADE SHOW Terms and Conditions for Delegates and Companions Shaw Convention Centre, Edmonton, AB June 5 8, 2015

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

Contents Windows

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

RAPID Prenez le contrôle sur vos données

Utiliser un proxy sous linux

Guide d'installation rapide TFM-560X YO.13

Editing and managing Systems engineering processes at Snecma

Laboratory accredited by the French Home Office (official gazette date February 5 th, 1959, modified) Valid five years from August 27 th, 2013

Frequently Asked Questions

Package Contents. System Requirements. Before You Begin

If the corporation is or intends to become a registered charity as defined in the Income Tax Act, a copy of these documents must be sent to:

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

CHANGE GUIDE France- Monaco- Guyana- Martinique- Guadeloupe- Reunion- Mayotte

MONTEGO 3 PERSON CUSHION GARDEN SWING WITH CANOPY ASSEMBLY INSTRUCTIONS ITEM# SC-177-2GS

INSTITUT MARITIME DE PREVENTION. For improvement in health and security at work. Created in 1992 Under the aegis of State and the ENIM

Stéphane Lefebvre. CAE s Chief Financial Officer. CAE announces Government of Canada participation in Project Innovate.

Garage Door Monitor Model 829LM

accidents and repairs:

FO-FDHB6-1 Central Heat Blower Kit for Onyx, Opel and Delta

France SMS+ MT Premium Description

AIDE FINANCIÈRE POUR ATHLÈTES FINANCIAL ASSISTANCE FOR ATHLETES

Bourses d excellence pour les masters orientés vers la recherche

ETABLISSEMENT D ENSEIGNEMENT OU ORGANISME DE FORMATION / UNIVERSITY OR COLLEGE:

Stratégie DataCenters Société Générale Enjeux, objectifs et rôle d un partenaire comme Data4

Installation d'un serveur RADIUS

Le passé composé. C'est le passé! Tout ça c'est du passé! That's the past! All that's in the past!

Immeuble indépendant 298 m2 sur 3 niveaux + terrasse 5bis rue de Beauce Paris

Maximum Capacity / Capacité maximal: 10 kg/min

Acce s aux applications informatiques Supply Chain Fournisseurs

TROIS ASPECTS DE LA COMPARAISON ALLEMAGNE-FRANCE SUR L ELECTRICITE

DOCUMENTATION - FRANCAIS... 2

Comprendre l impact de l utilisation des réseaux sociaux en entreprise SYNTHESE DES RESULTATS : EUROPE ET FRANCE

Free filter reminders! Sign up online at: santevia.com/filterease. need help? Contact Santevia!

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

GAME CONTENTS CONTENU DU JEU OBJECT OF THE GAME BUT DU JEU

Confirmation du titulaire de la carte en cas de contestation de transaction(s) Cardholder s Certification of Disputed Transactions

Stainless Steel Solar Wall Light

MODE D EMPLOI USER MANUAL

Practice Direction. Class Proceedings

Consultants en coûts - Cost Consultants

Curve. Innover pour simplifier! Mistral signe les fontaines High Tech à hauteur adaptable. Mistral signs the High Tech coolers with adaptable height

OpenOffice.org Calc Ouvrir un classeur

Table des matières QUINCAILLERIE FONCTIONNEL FUNCTIONAL HARDWARE. Clé H1 Serrure et pêne H2. Serrure à levier H4

Comment sauvegarder ses documents

CLASSIFICATION REPORT OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2007

BILL 203 PROJET DE LOI 203

Institut français des sciences et technologies des transports, de l aménagement

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

33 inch open & closed storage Rangement à espace fermé et ouvert de 33po (83.7cm) 33 pulgadas almacenaje abierto y cerra

IPSAS 32 «Service concession arrangements» (SCA) Marie-Pierre Cordier Baudouin Griton, IPSAS Board

PRINCIPE DE HOTTE SPÉCIALE COMPLÈTE TYPE «RHC» COMPLETE «RHC» TYPE SPECIAL HOOD SYSTEM

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

F1 Security Requirement Check List (SRCL)

TARIFS PIETONS SAISON PEDESTRIAN RATES SEASON 2014/2015 TARIFS ASSURANCE CARRE NEIGE CARRE NEIGE INSURANCE RATES 2014/2015

If you understand the roles nouns (and their accompanying baggage) play in a sentence...

Transcription:

INSTALLATION MANUAL Portrait President Cast Front Insert Model 536CXBI Approved for use with Valor heater 530 & 530 insert models only Requires the use of a 582CPB or 583CPB Closure Plate (sold seperately)! DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. INSTALLER Leave this manual with the appliance. CONSUMER Retain this manual for future reference. Notes: This kit must be installed or serviced by a qualified installer, service agency or gas supplier. These instructions are to be used in conjunction with the main installation instructions for the above listed heater models. Applications The President Cast Front for Insert 536CXBI is intended to install on the Valor Portrait 530 heater when installed as an insert fi replace. The Valor model 530 heater with the 536CXBI President Cast Front and 582 or 583 Closure Plate comes ready for installation as an insert unit into existing solid-fuel burning fi replaces provided space and local codes permit. 4005304-04 2018, Miles Industries Ltd. 1

Kit Contents 536CXBI 1 Front Casting Assembly with Barrier Screen 1 Top Baffle 1 Pack of Screws Top Baffle Casting Tolerances Due to the nature of cast iron, dimensional consistency may vary from one unit to the next and some variation in surface fi nish and fl atness is to be expected. We have done our best to control and make allowance for this; however some variation is inevitable. 536CXBI Front Casting with Barrier Screen 582CPB or 583CPB Closure Plate each kit supplied with the following: 1 Closure plate 2 Mounting brackets 4 M4 x 12 mm screws 6 No 8 x 3/8 screws The two models of closure plates vary in size. See following pages for Dimensions and installation of the closure plates. Mounting Brackets 582 Closure Plate 583 Closure Plate 582CPB or 583CPB 2

Insert dimensions for 3 engine configurations These dimensions are for non-combustible installations 20 A 8-3/4 Mantel leg See table D B 3/4 2 x 3 dia. colinear adaptor 2 x 3 dia. colinear vent E 4-1/8 4-3/4 x 3 dia. co-axial adaptor Do not put furniture or objects within 36 of front of appliance Ensure base of heater is flush with finished hearth height, otherwise cast front will not fit. 8-3/4 3/4 25-1/4 530 engine with 556CLA co-linear adaptor 3/8 19-1/4 530 insert engine with standard co-linear vent 3/4 7/8 530 insert engine with 530CVA co-axial vent adapter Clearances Mantel depth A Min. clearance B Up to 7 4 Above 7 up to 8 5 Above 8 up to 9 7 Above 9 up to 10 8 Above 10 up to 12 9 More than 12 9 +extra 1 for every 1 depth above 12 Mantel leg projection D Up to 8 2 More than 8 6 Min. clearance from appliance side E 3

582CPB or 583CPB Closure Plate (required) Dimensions Installation 1. Fit the top baffle under the top panel of the appliance case. Secure with 2 thread forming screws. 26 (660 mm) 31 (787 mm) 2. Locate and secure mounting brackets to side of engine with 2 screws each side; brackets are set forward from liner body front approximately 10mm (3/8 ) 582CPB Closure Plate 30 (762 mm) 33 (838 mm) 583CPB Closure Plate 4

3. Secure Closure Plate to Mounting Brackets with 6 thread forming screws. 4. If the hooks have been shipped loose with the cast front, fi x them to the front at its top corners. Hang the front on the appliance. 5

Cleaning WARNING DO NOT TOUCH THE BARRIER SCREEN, THE CAST FRONT OR THE GLASS WHILE THEY ARE HOT! Let the fireplace cool first before cleaning it. WARNING FOR YOUR SAFETY, ensure the barrier screen is reinstalled on the fireplace after maintenance. To clean the barrier screen and the cast front use a soft brush. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer s barrier for this appliance. To clean the fireplace glass window, refer to the owner s manual supplied with the appliance. DO NOT clean the glass with ammonia. Removing the front unit Unhook the front unit. Lift it up by holding the decorative grille. DO NOT lift it by holding the top. Always securely replace the window and the front with barrier screen before lighting. 6

Repair Parts List # Description Number Alternate no. 1 Front Unit 568979 040A519 2 Door Hinge Bolt 568999 420K558 3 Ashpan Door 568989 540K048AZ 4 Washer 532529 100B810 5 Magnet unit 569009 020A085 6 Front Casting 568929 050A255AZ 7 Front Casting Hook RH 568949 330A923 8 Front Casting Hook LH 568939 330A922 9 Top Casting 568969 550K065AZ 10 Top Baffle 569019 340B252AZ 11 Barrier Screen 4003359 4003359 12 Closure Plate 582-26 wide 31 high 4005203AZ 13 Closure Plate 583-30 wide 33 high 4005198AZ 14 Mounting Bracket (2) with each plate 4005199 14 1 8 10 9 7 13 (583CPB) 11 3 2 4 5 6 12 (582CPB) Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. Designed and Manufactured by / for Miles Industries Ltd. 190 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfireplaces.com 7

DIRECTIVES D INSTALLATION LE PREMIER MC FOYER À GAZ RADIANT Portrait Devanture de fonte President pour encastrables 536CXBI Homologuée pour usage avec les foyers Valor 530 et 530 encastrables seulement Exige l usage de la Plaque de finition 582CPB ou 583CPB (vendues séparément)! DANGER VITRE CHAUDE - RISQUE DE BRÛLURES. NE TOUCHEZ PAS UNE VITRE NON REFROIDIE. NE LAISSEZ JAMAIS UN ENFANT TOUCHER LA VITRE. L écran pare-étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection des enfants et des personnes à risques. INSTALLATEUR Laissez cette notice avec l appareil CONSOMMATEUR Conservez cette notice pour consultation ultérieure Note : Cette devanture doit être installée par un installateur qualifi ée, une agence de service certifi ée ou un fournisseur de gaz. Ces instructions doivent être utilisées conjointement avec les instructions fournies avec le foyer. Applications La Devanture de fonte President pour encastrables 536CSBI est conçue pour installer avec le foyer Valor Portrait 530 dans une application encastrable. Mis ensemble, le foyer Valor 530, la Devanture de fonte 536CXBI et la Plaque de fi nition 582CPB ou 583CPB fournissent les éléments nécessaires à l installation comme encastrables dans les foyers à combustibles solides lorsque l espace et les codes locaux le permettent. 8

Contenu des kits 536CXBI 1 Devanture de fonte avec Pare-étincelles 1 Défl ecteur du haut 1 Ensemble de vis Déflecteur du haut Variations de la fonte De par leur nature, deux articles de fonte fabriqués du même moule peuvent montrer de légères variations dans leurs dimensions et leur fi nition. Nous faisons tout ce qui est possible pour limiter ces variations qui ne peuvent cependant pas être éliminées. Devanture de fonte avec Pare-étincelles 536CXBI Plaques de finition 582CPB ou 583CPB chaque Plaque de fi nition fournie avec les articles suivants : 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis n o 8 x 3/8 Les deux de plaques de fi nition offertes sont de taille différente. Consultez les pages suivantes pour connaître les dimensions et les directives d installation des plaques de fi nition. Supports de montage Plaque de finition 582 Plaque de finition 583 582CPB ou 583CPB 9

Dimensions, applications encastrables - 3 configurations Ces dimensions sont pour installations incombustibles 20 (508 mm) A 8-3/4 (222 mm) Patte de manteauvoir table Manteau D B 3/4 (19 mm) Raccord colinéaire à 2 buses de 3 dia. 4-1/8 (105 mm) Évent colinéaire 2 buses de 3 dia. Raccord coaxial 4-3/4 x 3 dia. E Ne placez aucun meuble ou objet à moins de 36 (914 mm) du devant du foyer Assurez-vous que la base du foyer est égale à la surface de la dalle protectrice devant le foyer; autrement la devanture de fonte ne pourra pas être installée. 8-3/4 (222 mm) 3/4 (19 mm) Foyer 530 avec raccord colinéaire 556CLA 25-1/4 (641 mm) 3/8 (10 mm) Foyer 530 encastrable avec évent colinéaire 19-1/4 (489 mm) 3/4 (19 mm) 7/8 (22 mm) Foyer 530 encastrable avec raccord d évent coaxial 530CVA Dégagements (708 mm) Profondeur de manteau A Jusqu à 7 (178 mm) De 7 à 8 (178 à 203 mm) De 8 à 9 (203 à 229 mm) De 9 à 10 (229 à 254 mm) De 10 à 12 (254 à 305 mm) Plus de 12 (305 mm) Dégagement minimum B 4 (102 mm) 5 (127 mm) 7 (178 mm) 8 (203 mm) 9 (229 mm) 9 (229 mm) + 1 (25 mm) extra pour chaque 1 (25 mm) de profondeur audessus de 12 (305 mm) (553 mm) Projection de la patte de manteau D Jusqu à 8 (203 mm) Plus de 8 (203 mm) Dégagement minimum du côté de l appareil E 2 (51 mm) 6 (153 mm) 10

Plaque de finition 582CPB ou 583CPB (exigée) Dimensions Installation 1. Placez le défl ecteur du haut sous le panneau de dessus de la boîte de foyer. Fixez-le avec 2 vis autoformeuses. 26 (660 mm) 31 (787 mm) 2. Positionnez et fi xez les supports de montage de chaque côté de la caisse du foyer à l aide de 2 vis par côté; les supports dépassent l avant de la caisse d environ 3/8 de pouce (10mm). Plaque de finition 582CPB 30 (762 mm) 33 (838 mm) Plaque de finition 583CPB 11

3. Fixez la plaque de fi nition aux supports de montage à l aide de 6 vis autotaraudeuses. 4. Si les crochets ne sont pas installés, installez-les aux coins supérieurs de la devanture de fonte. Accrochez la devanture à l appareil. 12

Entretien AVERTISSEMENT NE TOUCHEZ PAS LE PARE-ÉTINCELLES, LA DEVANTURE OU LA FENÊTRE LORSQU ILS SONT CHAUDS! Laissez le foyer refroidir avant de le nettoyer. AVERTISSEMENT POUR RAISONS DE SÉCURITÉ, assurez-vous que le pare-étincelles soit réinstallé sur le foyer après l entretien. Pour nettoyer le pare-étincelles et la devanture de fonte, utilisez une brosse souple. Si le pare-étincelles est endommagé, il doit être remplacé par le pare-étincelles conçu par le manufacturier pour cet appareil. Pour nettoyer la vitre de la fenêtre du foyer, consultez le guide du consommateur fourni avec le foyer. NE PAS nettoyer la vitre avec un produit à base d ammoniaque. Enlèvement de la devanture Décrochez la devanture en la tenant sous la parure ornementale du haut. NE PAS soulever la devanture par son bord supérieur. Toujours remettre la fenêtre et la devanture munie du pare-étincelles en place et les fixer solidement avant d allumer le foyer. 13

Liste de pièces # Description Numéro Numéro alternatif 1 Devanture complète 568979 040A519 2 Boulon, charnière du garde-cendres 568999 420K558 3 Garde-cendres 568989 540K048AZ 4 Rondelle 532529 100B810 5 Aimant 569009 020A085 6 Devanture de fonte 568929 050A255AZ 7 Crochet, côté droit 568949 330A923 8 Crochet, côté gauche 568939 330A922 9 Dessus de fonte 568969 550K065AZ 10 Défl ecteur d air 569019 340B252AZ 11 Pare-étincelles 4003359 4003359 12 Plaque de fi nition 26 sur 31 4005203AZ 13 Plaque de fi nition 30 sur 33 4005198AZ 14 Supports de montage (2) avec chaque plaque 4005199 14 1 8 10 9 7 13 (583CPB) 12 (582CPB) 11 3 2 4 5 6 Parce que nous favorisons une politique de développement continu, certains détails de la présente publication peuvent varier. Conçue et fabriquée par / pour Miles Industries Ltd. 190 2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tél. 604-984-3496 Téléc. 604-984-0246 www.foyervalor.com 14