RAVWP12 12 depth RAVWP15 15 depth

Documents pareils
Lavatory Faucet. Instruction Manual. Questions?

Folio Case User s Guide

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

À noter, s il vous plaît : Ne pas utiliser de l alcool à friction. Il contient un hydratant et n est pas convenable pour nettoyer des cloisons.

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Guide d'installation rapide TFM-560X YO.13

Instructions Mozilla Thunderbird Page 1

Guide d installation Deco Drain inc. DD200

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Notice Technique / Technical Manual

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

Practice Direction. Class Proceedings

Module Title: French 4

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Contents Windows

DOCUMENTATION - FRANCAIS... 2

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

Package Contents. System Requirements. Before You Begin

Embases pour raccordement G1/8 - G1/4

Le No.1 de l économie d énergie pour patinoires.

How to Login to Career Page

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Paxton. ins Net2 desktop reader USB

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

DOCUMENTATION - FRANCAIS... 2

Profilés pour escalier Prostep Cerfix Prostep Wood

R.V. Table Mounting Instructions

SYSTÈME JETS D AIR WISH WISH AIR JETS SYSTEM Système de massage à jets d air pour bains en polymère - Air jet massage system for polymer bathtubs

Atelier Progress Rollbase

Contrôle d'accès Access control. Notice technique / Technical Manual

Once the installation is complete, you can delete the temporary Zip files..

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

Tutoriel de formation SurveyMonkey

Sécurité relative aux sièges auto et aux rehausseurs

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

Editing and managing Systems engineering processes at Snecma

PARIS ROISSY CHARLES DE GAULLE

Fabricant. 2 terminals

F1 Security Requirement Check List (SRCL)

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

Application Form/ Formulaire de demande

Nouveautés printemps 2013

Start Here Point de départ

Garage Door Monitor Model 829LM

Bill 69 Projet de loi 69

RULE 5 - SERVICE OF DOCUMENTS RÈGLE 5 SIGNIFICATION DE DOCUMENTS. Rule 5 / Règle 5

Start Here Point de départ Epson Stylus

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

has brought a motion to change the order of Justice, dated. the agreement between you and (name of party bringing this motion), dated.

USB 598. Quick Start Guide (Windows) Guide de démarrage rapide (Windows) USB Modem. Modem USB.

ONTARIO Court File Number. Form 17E: Trial Management Conference Brief. Date of trial management conference. Name of party filing this brief

MODE D EMPLOI USER MANUAL

BLUELINEA ,00 EUR composé de actions de valeur nominale 0,20 EUR Date de création : 17/01/2006

WEB page builder and server for SCADA applications usable from a WEB navigator

AIDE FINANCIÈRE POUR ATHLÈTES FINANCIAL ASSISTANCE FOR ATHLETES

Vanilla : Virtual Box

Stainless Steel Solar Wall Light

Spécial Catégorie 6 Patch Cords

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

lundi 3 août 2009 Choose your language What is Document Connection for Mac? Communautés Numériques L informatique à la portée du Grand Public

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

Name Use (Affiliates of Banks or Bank Holding Companies) Regulations

Quatre axes au service de la performance et des mutations Four lines serve the performance and changes

FÉDÉRATION INTERNATIONALE DE NATATION Diving

Gestion des prestations Volontaire

Trim Kit Installation Instruction

An Act to Amend the Tobacco Sales Act. Loi modifiant la Loi sur les ventes de tabac CHAPTER 46 CHAPITRE 46

MONTEGO 3 PERSON CUSHION GARDEN SWING WITH CANOPY ASSEMBLY INSTRUCTIONS ITEM# SC-177-2GS

MASSEY COLLEGE & UNIVERSITY OF TORONTO

72" STORAGE SHELF OR WORKBENCH ÉTAGERÈ DE RANGEMENT OU ETABLI DE 72 PO

ŒNOVIDEO. Demande d inscription. Festival International des Films documentaires sur la vigne et le vin. Madame, Monsieur,

accidents and repairs:

McGILL UNIVERSITY MARTLET CLASSIC UNIVERSITE McGILL CLASSIQUE MARTLET

Multiple issuers. La cotation des actions ROBECO ci-dessous est suspendue sur EURONEXT PARIS dans les conditions suivantes :

SA-32 / SA-62 INSTRUCTION MANUAL - MANUEL D INSTRUCTIONS

Restaurant Application Quick Reference Guide

ADHEFILM : tronçonnage. ADHEFILM : cutting off. ADHECAL : fabrication. ADHECAL : manufacturing.

Frequently Asked Questions

Guide pour l Installation des Disques Durs SATA et Configuration RAID

AUDIT COMMITTEE: TERMS OF REFERENCE

BILL 203 PROJET DE LOI 203

Comprendre l impact de l utilisation des réseaux sociaux en entreprise SYNTHESE DES RESULTATS : EUROPE ET FRANCE

PIB : Définition : mesure de l activité économique réalisée à l échelle d une nation sur une période donnée.

Appointment or Deployment of Alternates Regulations. Règlement sur la nomination ou la mutation de remplaçants CONSOLIDATION CODIFICATION

/MC Quick Install Guide Guide d installation rapide

Railway Operating Certificate Regulations. Règlement sur les certificats d exploitation de chemin de fer CODIFICATION CONSOLIDATION

INTERNATIONAL CONSULTANT & SUPPLIERS TO THE WINE & SPIRITS TRADE

Forthcoming Database

Judge Group: P Title: Quel est meilleur: le compost ou le fertilisant chimique? Student(s): Emma O'Shea Grade: 6

GASKET FOR TONER COLLECTION BOTTLE

If the corporation is or intends to become a registered charity as defined in the Income Tax Act, a copy of these documents must be sent to:

Toni Lazazzera Tmanco is expert partner from Anatole ( and distributes the solution AnatoleTEM

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

Conférence Bales II - Mauritanie. Patrick Le Nôtre. Directeur de la Stratégie - Secteur Finance Solutions risques et Réglementations

Transcription:

Installation instructions for your new wall plenum RAVWP6 6 depth RAVWP8 8 depth RAVWP12 12 depth RAVWP15 15 depth Before you begin Read these instructions completely and carefully. IMPORTANT OBSERVE ALL GOVERNING CODES AND ORDINANCES. Note to Installer Be sure to leave these instructions with the Consumer. Note to Consumer Keep these instructions with your Owner s Manual for future reference. YOUR WALL PLENUM WILL ONLY WORK IF INSTALLED CORRECTLY. MAKE SURE TO INSTALL IT IN THE CORRECT ORIENTATION AS SHOWN IN THE ILLUSTRATIONS. Tools Needed (depending on installation) Ruler or tape measure Level Screwdriver Hammer Pencil Drill Saw Parts Needed Flashing Caulk (silicone) Heading and framing materials Shims Attachment screws (6) plenum to wall Installation Overview Proper header for structural support. Apply proper caulking and flashing. Properly square and level plenum. NOTE: The plenum has a wax cardboard weather cover. Do not remove this cover until ready to install the architectural louver. Architectural Louver Exterior/ Outside Wall Wall Plenum Insulating Foam Strips Top and bottom (2) Sides (2) (cut to match depth of plenum exposed in the interior closet) RAVWP6 6 D x 19¾ W x 32 H RAVWP8 8 D x 19¾ W x 32 H RAVWP12 12 D x 19¾ W x 32 H RAVWP15 15 D x 19¾ W x 32 H Case 1 Pub No. 31-60912-1 07-10 GE

Step 1 Measure, cut and frame out the wall plenum opening Measure and mark on the inside of the external closet wall the plenum cutout dimensions as shown below. Step 2 Install the plenum 1. Before caulking and permanent attachment, place the plenum into the cutout hole and check for fit and level. External wall 20 32¼ 2. Insert the plenum into the cutout opening with 1/4 minimum protruding from the external wall. Side view 1/4 min. Outside Inside closet, looking out through wall plenum rough cutout IMPORTANT: The wall plenum is not designed to carry structural loads. A proper header opening must be built into the rough opening. The plenum requires flashing, shim and caulk for a weatherresistant installation. NOTE: It is the responsibility of the installer to properly install the plenum and meet building code requirements. (continued on next page) 2

Step 2 Install the plenum (cont.) 3. Attach the sides of the plenum to the wall studs using 6 screws. Use 3 screws on each side. Do not use screws in the plenum top or bottom. Step 3 Install the insulating foam strips 1. Measure and cut the shorter (top and bottom) foam strips to match the depth of the plenum that is exposed in the interior wall. NOTE: Pilot holes may need to be drilled through the plenum and into the frame. 2. Peel off the backing and apply the foam strips to the top and bottom of the plenum along the front edges and against the interior walls. (continued on next page) 3

Step 3 Install the insulating foam strips (cont.) 3. Measure and cut the longer (left and right) side foam top strips to match the depth of the plenum that is exposed in the interior wall. Step 4 Seal the plenum 1. Caulk the 6 screw heads and any gaps on the inside. 4. Peel off the backing and apply the foam strips to each side of the plenum along the front edges and against the interior walls. 2. From the outside, caulk all exterior gaps between the plenum and the wall. 4

Instructions d installation pour votre nouveau plénum mural RAVWP6 15 cm de profondeur RAVWP8 20 cm de profondeur RAVWP12 30 cm de profondeur RAVWP15 38 cm de profondeur Avant de commencer Lire attentivement ces instructions dans leur intégralité IMPORTANT OBSERVER TOUTES LES RÉGLEMENTATIONS ET ORDONNANCES EN VIGUEUR. Remarque pour l installateur S assurer de laisser ces instructions au client. Remarque pour le consommateur Garder ces instructions avec le manuel utilisateur pour référence ultérieure. LE PLÉNUM MURAL NE FONCTIONNE QUE S IL EST INSTALLÉ CORRECTEMENT. S ASSURER DE L INSTALLER DANS LA BONNE ORIENTATION COMME ILLUSTRÉ. Outils nécessaires (selon l installation) Règle ou mètre Niveau Tournevis Marteau Crayon Perceuse Scie Pièces nécessaires Solin Matériau d étanchéité (silicone) Cales Matériaux de chevêtre et de charpente Vis de fixation (6) du plenum au mur Aperçu de l installation Chevêtre approprié pour le support structurel. Appliquer le bon mastic et le bon solin. REMARQUE : Le plenum présente un couvercle de protection contre les intempéries en carton ciré. Ne pas retirer ce couvercle avant d être prêt à installer l évent à lames architectural. Aligner et mettre de niveau correctement le plenum Évent à lames architectural Extérieur/Mur extérieur Bandes de mousse isolantes Haut et bas (2) Côtés (2) (couper pour assortir la profondeur de plénum exposé dans le coffret intérieur) Plenum mural RAVWP6 15 cm profondeur x 50 cm de large x 81 cm de haut RAVWP8 20 cm profondeur x 50 cm de large x 81 cm de haut RAVWP12 25 cm profondeur x 50 cm de large x 81 cm de haut RAVWP15 32,5 cm profondeur x 50 cm de large x 81 cm de haut coffret 1 Pub No. 31-60912-1 08-10 GE

Étape 1 Mesurer, couper et charpenter l ouverture du plenum mural Mesurer et marquer sur l intérieur du mur extérieur du coffret les dimensions de découpe du plenum comme illustré ci-dessous. Étape 2 Installation du plenum 1. Avant de mettre du mastic et de le fixer de manière permanente, placer le plénum dans le trou découpé et vérifier son ajustement et son niveau. Mur extérieur 20 32¼ 2. Insérer le plénum dans la découpe en le faisant dépasser au minimum de 6 mm du mur externe. Vue de côté 6 mm min Extérieur Intérieur du coffret, en regardant dans la découpe grossière de plénum mural IMPORTANT : Le plénum mural n est pas conçu pour supporter des charges structurelles. Une ouverture appropriée pour le chevêtre doit être intégrée à l ouverture grossière. Le plenum nécessite du solin, des cales et du mastic pour assurer une installation résistant aux intempéries. REMARQUE : Il relève de la responsabilité de l installateur d installer correctement le plénum et de respecter les spécifications du code du bâtiment. (suite page suivante) 2

Étape 2 Installation du plenum (suite) 3. Fixer les côtés du plenum aux poteaux de cloison avec 6 vis. Utiliser 3 vis de chaque côté. Ne pas utiliser de vis dans le haut ou le bas du plenum. Étape 3 Installation des bandes de mousse isolante 1. Mesurer et couper les bandes de mousse plus courtes (haut et bas) en fonction de la profondeur du plenum qui est exposée dans le mur intérieur. REMARQUE : Des trous d implantation peuvent avoir à être percés dans le plenum et dans la charpente. 2. Détacher le support et appliquer les bandes de mousse sur le haut et le bas du plenum le long des bords avant et contre les murs intérieurs. (suite page suivante) 3

Étape 3 Installation des bandes de mousse isolante (suite) 3. Mesurer et couper les bandes de mousse plus courtes (haut et bas) pour correspondre à la profondeur du plenum qui est exposé dans le mur intérieur. Step 4 Seal the plenum 1. Mettre du mastic sur les 6 têtes de vis et dans les espaces de joint à l intérieur. 2. De l extérieur, mettre du mastic dans les espaces de joint extérieurs entre le plenum et le mur. 4. Écarter le support et appliquer les bandes de mousse sur chaque côté du plenum le long des bords avant et contre les murs intérieurs. 4