INSULATED JACKET INSTALLATION INSTRUCTIONS for Built-In Outdoor Grills



Documents pareils
R.V. Table Mounting Instructions

Notice Technique / Technical Manual

Warning: Failure to follow these warnings could result in property damage, or personal injury.

Instructions Mozilla Thunderbird Page 1

Folio Case User s Guide

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

Guide d'installation rapide TFM-560X YO.13

Package Contents. System Requirements. Before You Begin

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Paxton. ins Net2 desktop reader USB

Contrôle d'accès Access control. Notice technique / Technical Manual

DOCUMENTATION - FRANCAIS... 2

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

How to Login to Career Page

Lavatory Faucet. Instruction Manual. Questions?

Guide d installation Deco Drain inc. DD200

BILL 203 PROJET DE LOI 203

Table of Contents/Table des matières COOKTOP SAFETY

Garage Door Monitor Model 829LM

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

Sécurité relative aux sièges auto et aux rehausseurs

Cheque Holding Policy Disclosure (Banks) Regulations. Règlement sur la communication de la politique de retenue de chèques (banques) CONSOLIDATION

POLICY: FREE MILK PROGRAM CODE: CS-4

Contents Windows

Gestion des prestations Volontaire

If you understand the roles nouns (and their accompanying baggage) play in a sentence...

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Application Form/ Formulaire de demande

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

lundi 3 août 2009 Choose your language What is Document Connection for Mac? Communautés Numériques L informatique à la portée du Grand Public

First Nations Assessment Inspection Regulations. Règlement sur l inspection aux fins d évaluation foncière des premières nations CONSOLIDATION

LE FORMAT DES RAPPORTS DU PERSONNEL DES COMMISSIONS DE DISTRICT D AMENAGEMENT FORMAT OF DISTRICT PLANNING COMMISSION STAFF REPORTS

FOURTH SESSION : "MRP & CRP"

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

Embases pour raccordement G1/8 - G1/4

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

Once the installation is complete, you can delete the temporary Zip files..

Exemple PLS avec SAS

DOCUMENTATION - FRANCAIS... 2

Fabricant. 2 terminals

Quick Start Guide This guide is intended to get you started with Rational ClearCase or Rational ClearCase MultiSite.

Quick Installation Guide TEW-AO12O

À noter, s il vous plaît : Ne pas utiliser de l alcool à friction. Il contient un hydratant et n est pas convenable pour nettoyer des cloisons.

WEB page builder and server for SCADA applications usable from a WEB navigator

SM6. fiche adaptation adaptation instructions. résistances chauffantes. heating resistors. distribution MT ensembles préfabriqués à votre service

PARIS ROISSY CHARLES DE GAULLE

Utiliser une WebCam. Micro-ordinateurs, informations, idées, trucs et astuces

AMENDMENT TO BILL 32 AMENDEMENT AU PROJET DE LOI 32

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

72" STORAGE SHELF OR WORKBENCH ÉTAGERÈ DE RANGEMENT OU ETABLI DE 72 PO

1.The pronouns me, te, nous, and vous are object pronouns.

Credit Note and Debit Note Information (GST/ HST) Regulations

Monitor LRD. Table des matières

JSIam Introduction talk. Philippe Gradt. Grenoble, March 6th 2015

Stainless Steel Solar Wall Light

Quatre axes au service de la performance et des mutations Four lines serve the performance and changes

L. Obert, T. Lascar, A. Adam

Le Cloud Computing est-il l ennemi de la Sécurité?

APPENDIX 6 BONUS RING FORMAT

DOCUMENTATION - FRANCAIS... 2

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

Get Instant Access to ebook Cest Maintenant PDF at Our Huge Library CEST MAINTENANT PDF. ==> Download: CEST MAINTENANT PDF

SÉCURITÉ DU LAVE-VAISSELLE

Module Title: French 4

CEST POUR MIEUX PLACER MES PDF

FÉDÉRATION INTERNATIONALE DE NATATION Diving

Editing and managing Systems engineering processes at Snecma

Comment Créer une Base de Données Ab Initio

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

Support Orders and Support Provisions (Banks and Authorized Foreign Banks) Regulations

Dans une agence de location immobilière...

Vanilla : Virtual Box

MANUEL MARKETING ET SURVIE PDF

Stratégie DataCenters Société Générale Enjeux, objectifs et rôle d un partenaire comme Data4

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Interest Rate for Customs Purposes Regulations. Règlement sur le taux d intérêt aux fins des douanes CONSOLIDATION CODIFICATION

F1 Security Requirement Check List (SRCL)

GASKET FOR TONER COLLECTION BOTTLE

Loi sur l aide financière à la Banque Commerciale du Canada. Canadian Commercial Bank Financial Assistance Act CODIFICATION CONSOLIDATION

Ships Elevator Regulations. Règlement sur les ascenseurs de navires CODIFICATION CONSOLIDATION. C.R.C., c C.R.C., ch. 1482

RÈGLEMENT SUR LES CEINTURES DE SÉCURITÉ ET LES ENSEMBLES DE RETENUE POUR ENFANTS R.R.T.N.-O. 1990, ch. M-35

INVESTMENT REGULATIONS R In force October 1, RÈGLEMENT SUR LES INVESTISSEMENTS R En vigueur le 1 er octobre 2001

Lesson Plan Physical Descriptions. belle vieille grande petite grosse laide mignonne jolie. beau vieux grand petit gros laid mignon

RAPID Prenez le contrôle sur vos données

Tex: The book of which I'm the author is an historical novel.

Logitech Speaker System Z553 Setup Guide Guide d installation

FO-FDHB6-1 Central Heat Blower Kit for Onyx, Opel and Delta

Nouveautés printemps 2013

L'Offre sera ouverte pendant 18 jours de bourse, à un prix par action de 152,30 EUR. BPCE International et Outre-Mer

Comment Accéder à des Bases de Données MySQL avec Windows lorqu'elles sont sur un Serveur Linux

CETTE FOIS CEST DIFFERENT PDF

Utiliser un proxy sous linux

Transcription:

INSULTED JCET INSTLLTION INSTRUCTIONS for Built-In Outdoor Grills INSTLLTION REQUIREMENTS... 1 Tools and Parts... 1 Location Requirements... 2 Product Dimensions... 2 Built-In Outdoor Grill Enclosure... 2 Cabinet Cutout Dimensions... 3 INSTLLTION INSTRUCTIONS... 5 Prepare Built-In Grill for Insulated Jacket Installation... 5 Install Insulated Jacket... 6 Table of Contents / Table des matières EXIGENCES D'INSTLLTION... 7 Outillage et pièces... 7 Exigences d'emplacement... 8 Dimensions du produit... 8 Enceinte du gril d'extérieur encastré... 8 Dimensions de l'ouverture à découper dans le placard... 9 INSTRUCTIONS D'INSTLLTION... 11 Préparation du gril encastré pour l'installation d'un chemisage isolé... 11 Installation du chemisage isolé... 12 Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. lways read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. ll safety messages will follow the safety alert symbol and either the word DNGER or WRNING. These words mean: DNGER You can be killed or seriously injured if you don't immediately follow instructions. WRNING You can be killed or seriously injured if you don't follow instructions. ll safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. IMPORTNT: This grill is manufactured for outdoor use only. For grills that are to be used at elevations above 2000 ft (609.6 m) orifice conversion is required. See Gas Supply Requirements section. It is the responsibility of the installer to comply with the minimum installation clearances specified on the model/serial rating plate. The model/serial rating plate can be found on the right-hand side of the grill. INSTLLTION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools Needed #2 Phillips screwdriver #3 Phillips screwdriver Parts Supplied Insulated jacket Side mounting flanges Back mounting flange W10138385

Location Requirements Product Dimensions WRNING 38" (96.5 cm) Explosion Hazard Do not store fuel tank in a garage or indoors. Do not store grill with fuel tank in a garage or indoors. Failure to follow these instructions can result in death, explosion, or fire. 25⁵ ₈" (65.0 cm) B 11¾" (29.8 cm) 27¾" (70.5 cm) 23⁷ ₈" (60.5 cm) WRNING Fire Hazard Do not use grill near combustible materials. Do not store combustible materials near grill. Doing so can result in death or fire. Select a location that provides minimum exposure to wind and traffic paths. The location should be away from strong draft areas. Do not obstruct flow of combustion and ventilation air. Clearance to combustible construction for built-in and freestanding outdoor grills: minimum of 24" (58.0 cm) must be maintained between the front of the grill hood, sides and back of the grill and any combustible construction. zero clearance may be maintained on the insulated jacket surfaces to any combustible construction.. 27" (68.6 cm) 36" (91.4 cm) 48" (121.9 cm) B. 27" (68.6 cm) models - 32⁷ ₈" (83.3 cm) 36" (91.4 cm) models - 41⁷ ₈" (106.2 cm) 48" (121.9 cm) models - 53⁷ ₈" (136.6 cm) Built-In Outdoor Grill Enclosure The insulated jacket kit is used to prepare a built-in grill purchased for a non-combustible enclosure to be installed in a combustible enclosure. Built-in grills without a jacket are to be installed only in a non-combustible enclosure and are rated for Natural/LP gas. If a combustible enclosure is used, a jacketed grill is required. n insulated jacket kit is available to convert a built-in grill for use in a combustible enclosure. The enclosure for the built-in outdoor grill is to be a minimum of 11" (28.0 cm) high x 23" (58.4 cm) deep x (33" [83.8 cm] for 27" [68.6 cm] grill and 42" [106.7 cm] for 36" [91.4 cm] grill and 54" [137.2 cm] for 48" [121.9 cm] grill) wide. The installation of this grill must conform with local codes or, in the absence of local codes, with either the National Fuel Gas Code, NSI Z223.1/NPF 54, Natural Gas and Propane Installation Code, CS B149.1, or Propane Storage and Handling Code, B149.2. Copies of the standards listed may be obtained from: CS International 8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575 NOTE: The insulated jacket drops into the opening and the bottom of the insulated jacket should be supported by the bottom support of the cabinet cutout. Do not use side support on insulated jacket built-in grills. 2

Cabinet Cutout Dimensions The dimension chart and illustration below include cutout dimensions and minimum spacing requirements for all built-in outdoor products. The illustration is for reference. The design of your cabinet layout can be personalized, but the dimensions for the cutouts and minimum spacing must be followed. C 3" (7.6 cm) min. to open hood C E 12" (30.5 cm) min. to any accessory 12" min. to any accessory 9¹ ₈" (23.2 cm) 5" (12.7 cm) min. E J Side or Sear Burners D Grills or Refreshment Centers Warming Drawer ccess Doors Utility or Trash Drawer 20⁷ ₈" (53.0 cm) 2¹ ₂" (6.4 cm) min. L D 1¹ ₂" (3.8 cm) min. 20⁵ ₈" (52.4 cm) Refrigerator or Ice Maker G H B F M Minimum Spacing Requirement Between Cutouts - Dimension Between 2 or more sets of ccess Doors adjacent to each other: = 14" (35.6 cm) when 2 adjacent doors are opened to 90 degrees = 8" (20.3 cm) when 1 of the adjacent doors is opened to 90 degrees Between a set of ccess Doors and a Trash Drawer, Utility Drawer, Warming Drawer, Refrigerator, or Ice Maker: = 8" (20.3 cm) when 1 of the adjacent doors is opened to 90 degrees Between a Trash Drawer, Utility Drawer, or Warming Drawer: = 3" (7.6 cm) Cabinet Height and Depth Dimensions Dimension Minimum Dimension B Minimum With outdoor refrigerator 37" (94.0 cm) 26" (66.0 cm) Grill with insulated jacket 36½" (92.7 cm) 27" (68.6 cm) Grill without insulated jacket 35½" (90.2 cm) 26" (66.0 cm) 3

Cutout Dimensions - Built-in Grill Grill Size Dimension C Dimension D Dimension E 27" (68.6 cm) 29⁵ ₈" (75.2 cm) 10¾" (27.3 cm) 22⁷ ₈" (58.1 cm) 36" (91.4 cm) 38⁵ ₈" (98.1 cm) 10¾" (27.3 cm) 22⁷ ₈" (58.1 cm) 48" (121.9 cm) 50⁵ ₈" (128.6 cm) 10¾" (27.3 cm) 22⁷ ₈" (58.1 cm) Cutout Dimensions - Built-in Grill with Insulated Jacket Grill Size Dimension C Dimension D Dimension E 27" (68.6 cm) 33" (83.8 cm) 11¾" (29.8 cm) 24" (61.0 cm) 36" (91.4 cm) 42" (106.7 cm) 11¾" (29.8 cm) 24" (61.0 cm) 48" (121.9 cm) 54" (137.2 cm) 11¾" (29.8 cm) 24" (61.0 cm) Cutout Dimensions - Built-in Side Burner Burner Position Dimension C Dimension D Dimension E Front to Back 13½" (34.3 cm) 10¾" (27.3 cm) 22⁵ ₈" (57.5 cm) Side by Side 24½" (62.2 cm) 10¾" (27.3 cm) 16⁷ ₈" (42.9 cm) Cutout Dimensions - Built-in Sear Burner Dimension C Dimension D Dimension E 13½" (34.3 cm) 10⁵ ₈" (27.0 cm) 22¹¹ ₁₆" (57.6 cm) Cutout Dimensions - Built-in Refreshment Center Dimension C Dimension D Dimension E 30½" (77.5 cm) 10¾" (27.3 cm) 23" (58.4 cm) Cutout Dimensions - Built-in ccess Doors Door Size Dimension F Dimension L* 18" (45.7 cm) 16³ ₁₆" (41.1 cm) 1½ (3.8 cm) 27" (68.6 cm) 25¹ ₈" (63.8 cm) 1½ (3.8 cm) 30" (76.2 cm) 28¹ ₈" (71.4 cm) 1½ (3.8 cm) 36" (91.4 cm) 34¹ ₈" (86.7 cm) 1½ (3.8 cm) 48" (121.9 cm) 46¹ ₈" (117.2 cm) 1½ (3.8 cm) *Dimension L is the minimum mounting surface area around the opening for mounting the optional door or drawers. 4

Cutout Dimensions - Outdoor Refrigerator Dimension G Dimension H 24" (61.0 cm) 35¼" (89.5 cm) Cutout Dimensions - Outdoor Ice Maker Dimension G Dimension H 18" (45.7 cm) 34" (86.4 cm) min. to 34½" (87.6 cm) max. Cutout Dimensions - Built-in Warming Drawer Warming Drawer Size Dimension J 24" (61.0 cm) 22½" (57.2 cm) Cutout Dimensions - Built-in Utility Drawer and Built-in Trash Drawer Dimension M Dimension L* 12¼" (31.1 cm) 1½ (3.8 cm) *Dimension L is the minimum mounting surface area around the opening for mounting the optional door or drawers. Excessive Weight Hazard Use two or more people to move and install grill. Failure to do so can result in back or other injury. INSTLLTION INSTRUCTIONS Prepare Built-In Grill for Insulated Jacket Installation WRNING 1. Unpack grill. Remove all packaging materials and remove grill from carton. 2. Move grill close to desired outdoor location. 3. Using a #3 Phillips screwdriver, remove the 6 side flange spacers from both sides of the grill (3 on each side).. Side flange spacers 5

4. Using a #3 Phillips screwdriver, remove the 2 side flanges from the sides of the grill and set aside. 5. Using a #2 Phillips Screwdriver remove and set aside the 3 fasteners on the back side of the grill as shown in the illustration.\. Fasteners WRNING Install Insulated Jacket Excessive Weight Hazard Use two or more people to move and install insulated jacket. Failure to do so can result in back or other injury. 1. Unpack insulated jacket. Remove all packaging materials and remove insulated jacket from carton. 2. Move insulated jacket close to desired outdoor location. 3. Using the 3 fasteners you previously removed, install the insulated jacket back mounting flange on the grill securely, tightening the fasteners.. Side mounting flange 5. Place the insulated jacket into the enclosure cutout. 6. Lift the grill into the insulated jacket and ensure that the grill flange rests on top of the lip on the insulated jacket and is supported by the bottom support of the cutout. 7. Check to be sure there is enough room at the back of the grill to connect to the gas supply and electrical plug-in. B. Back mounting flange 4. Using the 6 fasteners previously removed from the grill side flanges and a #3 Phillips screwdriver, install the insulated jacket side mounting flanges on each side of the grill.. Mounting flange B. Insulated jacket 8. Proceed with normal grill installation. See Outdoor Grill Installation Instructions. 6

INSTRUCTIONS D'INSTLLTION - CHEMISGE ISOLÉ pour grils encastrés d extérieur Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. ssurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d alerte de sécurité. Ce symbole d alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d autres. Tous les messages de sécurité suivront le symbole d alerte de sécurité et le mot DNGER ou VERTISSEMENT. Ces mots signifient : DNGER VERTISSEMENT Risque possible de décès ou de blessure grave si vous ne suivez pas immédiatement les instructions. Risque possible de décès ou de blessure grave si vous ne suivez pas les instructions. Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et ce qui peut se produire en cas de non-respect des instructions. IMPORTNT : Ce gril est conçu et fabriqué pour l'utilisation à l'extérieur uniquement. Pour un gril qui doit être utilisé à une altitude supérieure à 2000 pi (609,6 m), il est nécessaire de changer le gicleur d'admission de gaz. Voir la section Spécifications de l'alimentation en gaz. C'est à l'installateur qu'incombe la responsabilité de respecter les distances de séparation minimums spécifiées sur la plaque signalétique. On trouve la plaque signalétique sur le côté droit du gril. EXIGENCES D'INSTLLTION Outillage et pièces Rassembler les outils et pièces nécessaires avant de commencer l'installation. Lire et suivre les instructions fournies avec les outils indiqués ici. Outillage nécessaire : Tournevis Phillips n 2 Tournevis Phillips n 3 Pièces fournies Chemisage isolé Tringles de montage latérales Tringle de montage arrière 7

Exigences d'emplacement Dimensions du produit VERTISSEMENT 38" (96,5 cm) Risque d'explosion Ne pas remiser de réservoir à carburant dans un garage ou à l'intérieur. Ne pas remiser un gril avec réservoir de carburant dans un garage ou à l'intérieur. Le non-respect de ces instructions peut causer un décès, une explosion ou un incendie. 25⁵ ₈" (65,0 cm) B 11¾" (29,8 cm) 27¾" (70,5 cm) 23⁷ ₈" (60,5 cm) VERTISSEMENT. 27" (68,6 cm) 36" (91,4 cm) 48" (121,9 cm) B. Modèles de 27" (68,6 cm) - 32⁷ ₈" (83,3 cm) Modèles de 36" (91,4 cm) - 41⁷ ₈" (106,2 cm) Modèles de 48" (121,9 cm) - 53⁷ ₈" (136,6 cm) Risque d'incendie Ne pas utiliser le gril près de matériaux combustibles. Ne pas remiser de matériaux combustibles près du gril. Le non-respect de ces instructions peut causer un décès ou un incendie. Choisir un emplacement d'installation qui minimise l'exposition au vent et à la circulation des personnes. L'emplacement d'installation devra être éloigné de toute zone de fort courant d'air. Ne pas entraver la circulation de l'air (pour combustion et ventilation). Dégagement de séparation à respecter par rapport au matériau combustible pour un gril utilisé à l'extérieur (autonome ou encastré) : Dégagement de 24" (58,0 cm) ou plus entre tout matériau combustible et l'avant du capot du gril, les côtés et l'arrière du gril. ucun dégagement n est nécessaire entre la surface du chemisage isolé et toute construction combustible. Enceinte du gril d'extérieur encastré Le chemisage isolé permet de préparer l'installation dans une enceinte combustible d'un gril à encastrer conçu initialement pour l'installation dans une enceinte non combustible. Un gril encastré sans chemisage ne peut être installé que dans une enceinte non combustible et doit être alimenté au gaz naturel ou au propane. Si le gril est installé dans une enceinte combustible, l'emploi d'un chemisage isolant est nécessaire. Un chemisage d'isolation est disponible pour la conversion d'un gril encastré pour utilisation dans une enceinte combustible. Dimensions minimales de l'enceinte qui recevra le gril d extérieur encastré : hauteur 11" (28,0 cm) x profondeur 23" (58,4 cm) x (33" [83,8 cm] pour gril de 27" [68,6 cm] et 42" [106,7 cm] pour gril de 36" [91,4 cm] et 54" [137,2 cm] pour gril de 48" [121,9 cm]) (largeur). L'installation de ce gril doit être réalisée en conformité avec les prescriptions des codes locaux ou, en l'absence de codes locaux, avec les prescriptions du Code national en vigueur : National Fuel Gas Code, NSI Z223.1/NPF 54, code CS B149.1 (Installation à gaz naturel ou propane), ou CS B149.2 (Utilisation et stockage du propane). Pour obtenir un exemplaire des normes mentionnées : CS International 8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575 REMRQUE : Le chemisage isolé sera inséré dans l'ouverture; le fond du chemisage isolé doit être soutenu par un support au fond de l'ouverture découpée dans l'enceinte d'encastrement. Ne pas utiliser un support latéral pour un gril encastré avec chemisage isolé. 8

Dimensions de l'ouverture à découper dans le placard Le tableau de dimensions et l'illustration ci-dessous comprennent les dimensions de l'ouverture à découper et les valeurs minimales de dégagements de séparation pour tous les produits d'extérieur encastrés. L'illustration est à titre de référence. La conception de la disposition de votre placard peut être personnalisée, mais les dimensions pour les ouvertures à découper et les dégagements de séparation doivent être respectées. C 3" (7,6 cm) min. vers le capot ouvert C E 12" (30,5 cm) min. vers n'importe quel accessoire 12" min. vers n'importe quel accessoire 9¹ ₈" (23,2 cm) 5" (12,7 cm) min. E J Brûleurs latéraux ou à infrarouge D Grils ou comptoirs pour rafraîchissements Tiroirréchaud Portes d'accès Tiroir utilitaire ou à déchets 20⁷ ₈" (53,0 cm) 2¹ ₂" (6,4 cm) min. L D 1¹ ₂" (3,8 cm) min. 20⁵ ₈" (52,4 cm) Réfrigérateur ou machine à glaçons G H B F M Valeur de dégagement de séparation minimale entre les ouvertures à découper - Dimension Entre au moins 2 portes d'accès adjacentes : = 14" (35,6 cm) lorsque 2 portes adjacentes sont ouvertes à 90 degrés = 8" (20,3 cm) lorsque l'une des portes adjacentes est ouverte à 90 degrés Entre un ensemble de portes d'accès et un tiroir à déchets, un tiroir utilitaire, un tiroir-réchaud, réfrigérateur ou machine à glaçons : = 8" (20,3 cm) lorsque l'une des portes adjacentes est ouverte à 90 degrés Entre un tiroir à déchets, un tiroir utilitaire ou un tiroir-réchaud : = 3" (7,6 cm) Dimensions de hauteur et profondeur pour le placard Dimension Minimum Dimension B Minimum vec réfrigérateur d'extérieur 37" (94,0 cm) 26" (66 cm) Gril avec housse d'isolation 36½" (92,7 cm) 27" (68,6 cm) Gril sans housse d'isolation 35½" (90,2 cm) 26" (66 cm) 9

Dimensions de l'ouverture à découper - Gril encastré Taille du gril Dimension C Dimension D Dimension E 27" (68,6 cm) 29⁵ ₈" (75,2 cm) 10¾" (27,3 cm) 22⁷ ₈" (58,1 cm) 36" (91,4 cm) 38⁵ ₈" (98,1 cm) 10¾" (27,3 cm) 22⁷ ₈" (58,1 cm) 48" (121,9 cm) 50⁵ ₈" (128,6 cm) 10¾" (27,3 cm) 22⁷ ₈" (58,1 cm) Dimensions de l'ouverture à découper - Gril encastré avec housse d'isolation Taille du gril Dimension C Dimension D Dimension E 27" (68,6 cm) 33" (83,8 cm) 11¾" (29,8 cm) 24" (61 cm) 36" (91,4 cm) 42" (106,7 cm) 11¾" (29,8 cm) 24" (61 cm) 48" (121,9 cm) 54" (137,2 cm) 11¾" (29,8 cm) 24" (61 cm) Dimensions de l'ouverture à découper - Brûleur latéral encastré Position du brûleur Dimension C Dimension D Dimension E De l'avant vers l'arrière 13½" (34,3 cm) 10¾" (27,3 cm) 22⁵ ₈" (57,5 cm) Côte à côte 24½" (62,2 cm) 10¾" (27,3 cm) 16⁷ ₈" (42,9 cm) Dimensions de l'ouverture à découper - Brûleur à infrarouge encastré Dimension C Dimension D Dimension E 13½" (34,3 cm) 10⁵ ₈" (27,0 cm) 22¹¹ ₁₆" (57,6 cm) Dimensions de l'ouverture à découper - Comptoir pour rafraîchissements encastré Dimension C Dimension D Dimension E 30½" (77,5 cm) 10¾" (27,3 cm) 23" (58,4 cm) Dimensions de l'ouverture à découper - Portes d'accès encastrées Taille de la porte Dimension F Dimension L* 18" (45,7 cm) 16³ ₁₆" (41,1 cm) 1½" (3,8 cm) 27" (68,6 cm) 25¹ ₈" (63,8 cm) 1½" (3,8 cm) 30" (76,2 cm) 28¹ ₈" (71,4 cm) 1½" (3,8 cm) 36" (91,4 cm) 34¹ ₈" (86,7 cm) 1½" (3,8 cm) 48" (121,9 cm) 46¹ ₈" (117,2 cm) 1½" (3,8 cm) *La dimension L représente la zone de surface de montage minimale autour de l'ouverture pour le montage de la porte ou des tiroirs facultatifs. 10

Dimensions de l'ouverture à découper - Réfrigérateur d'extérieur Dimension G Dimension H 24" (61,0 cm) 35¼" (89,5 cm) Dimensions de l'ouverture à découper - Machine à glaçons d'extérieur Dimension G Dimension H 18" (45,7 cm) 34" (86,4 cm) min. à 34½" (87,6 cm) max. Dimensions de l'ouverture à découper - Tiroir-réchaud encastré Taille du tiroir-réchaud Dimension J 24" (61 cm) 22½" (57,2 cm) Dimensions de l'ouverture à découper - Tiroir utilitaire encastré ou tiroir à déchets encastré Dimension M Dimension L* 12¼" (31,1 cm) 1½ (3,8 cm) *La dimension L représente la zone de surface de montage minimale autour de l'ouverture pour le montage de la porte ou des tiroirs facultatifs. INSTRUCTIONS D'INSTLLTION Préparation du gril encastré pour l'installation d'un chemisage isolé VERTISSEMENT Risque du poids excessif Utiliser deux ou plus de personnes pour déplacer et installer le gril. Le non-respect de cette instruction peut causer une blessure au dos ou d'autre blessure. 3. Utiliser un tournevis Phillips n 3 pour enlever les 6 cales d'espacement des deux côtés du gril (3 de chaque côté) 1. Déballer le gril. Retirer tout matériau d'emballage et retirer le gril de l'emballage. 2. pprocher le gril de l'emplacement d'installation désiré à l'extérieur.. Cales des tringles latérales 11

4. Utiliser un tournevis Phillips n 3 pour enlever les 2 tringles de montage latérales des côtés du gril; conserver celles-ci à part. 5. Utiliser un tournevis Phillips n 2 pour enlever les 3 vis de fixation du panneau arrière du gril (voir l'illustration) - conserver les vis.. Fermoirs VERTISSEMENT Risque du poids excessif Utiliser deux ou plus de personnes pour déplacer et installer le chemisage isolé. Le non-respect de cette instruction peut causer une blessure au dos ou d'autre blessure. Installation du chemisage isolé 1. Déballer le chemisage isolé. Retirer tout matériau d'emballage et retirer le chemisage isolé de l'emballage. 2. pprocher le chemisage isolé de l'emplacement d'installation désiré à l'extérieur. 3. Utiliser les 3 vis enlevées précédemment pour installer la tringle de montage arrière du chemisage isolé sur le gril; serrer solidement les vis.. Tringle de montage latérale 5. Placer le chemisage isolé dans l'espace d'encastrement. 6. Soulever le gril pour l'insérer dans le chemisage isolé; veiller à ce que le rebord du gril prenne appui au sommet de la lèvre du chemisage isolé, et à ce qu'il soit soutenu par le support du fond de l'espace d'encastrement. 7. Vérifier la présence d'un espace suffisant à l'arrière du gril pour le raccordement à la canalisation de gaz et au circuit électrique. B.Tringle de montage arrière 4. Utiliser les 6 vis enlevées précédemment (elles fixaient les tringles latérales du gril) pour installer les tringles de montage du chemisage isolé sur chaque côté du gril (tournevis Phillips n 3).. Tringle de montage B. Chemisage isolé 8. Poursuivre le processus normal d'installation du gril. Voir les instructions d'installation du gril d extérieur. W10138385 2008. ll rights reserved. Tous droits réservés. 11/08 Printed in China Imprimé en Chine