INSTALLATION INSTRUCTIONS PVSDS1-1 DEEP SHROUD KIT

Documents pareils
Lavatory Faucet. Instruction Manual. Questions?

Folio Case User s Guide

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE ombre pendant lamp lampe suspendue à tons dégradés, chocolat

ASSEMBLY INSTRUCTIONS DIRECTIVES POUR L'ASSEMBLAGE luster chandelier lamp chandelier à trois branches en verre lustré

R.V. Table Mounting Instructions

Guide d'installation rapide TFM-560X YO.13

Warning: Failure to follow these warnings could result in property damage, or personal injury.

GIGABIT PCI DESKTOP ADAPTER DGE-530T. Quick Installation Guide+ Guide d installation+

Table des matières QUINCAILLERIE FONCTIONNEL FUNCTIONAL HARDWARE. Clé H1 Serrure et pêne H2. Serrure à levier H4

03/2013. Mod: WOKI-60IP/TR. Production code: DTWIC 6000

MONTEGO 3 PERSON CUSHION GARDEN SWING WITH CANOPY ASSEMBLY INSTRUCTIONS ITEM# SC-177-2GS

Instructions Mozilla Thunderbird Page 1

Fabricant. 2 terminals

PARIS ROISSY CHARLES DE GAULLE

WINTER BOAT STORAGE SYSTEM SYSTÈME DE REMISAGE HIVERNAL POUR BATEAU

Instructions pour mettre à jour un HFFv2 v1.x.yy v2.0.00

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

Application Form/ Formulaire de demande

Package Contents. System Requirements. Before You Begin

Notice Technique / Technical Manual

Logitech Tablet Keyboard for Windows 8, Windows RT and Android 3.0+ Setup Guide Guide d installation

TABLE DES MATIERES A OBJET PROCEDURE DE CONNEXION

France SMS+ MT Premium Description

SYSTÈME JETS D AIR WISH WISH AIR JETS SYSTEM Système de massage à jets d air pour bains en polymère - Air jet massage system for polymer bathtubs

How to Login to Career Page

Compléter le formulaire «Demande de participation» et l envoyer aux bureaux de SGC* à l adresse suivante :

Embases pour raccordement G1/8 - G1/4

Guide d installation Deco Drain inc. DD200

Trim Kit Installation Instruction

The new consumables catalogue from Medisoft is now updated. Please discover this full overview of all our consumables available to you.

Paxton. ins Net2 desktop reader USB

Thank you for choosing the Mobile Broadband USB Stick. With your USB Stick, you can access a wireless network at high speed.

MELTING POTES, LA SECTION INTERNATIONALE DU BELLASSO (Association étudiante de lʼensaparis-belleville) PRESENTE :

that the child(ren) was/were in need of protection under Part III of the Child and Family Services Act, and the court made an order on

Règlement sur le télémarketing et les centres d'appel. Call Centres Telemarketing Sales Regulation

DOCUMENTATION - FRANCAIS... 2

Contrôle d'accès Access control. Notice technique / Technical Manual

WiFi Security Camera Quick Start Guide. Guide de départ rapide Caméra de surveillance Wi-Fi (P5)

Contents Windows

Stainless Steel Solar Wall Light

NORMES D INSTALLATION PARTITION W/SCA Avec rideau gonflable

GASKET FOR TONER COLLECTION BOTTLE

Tutoriel de formation SurveyMonkey

SYSTÈME DE GAINES À SPIRALE ET RACCORDS TOURNANTS

English Q&A #1 Braille Services Requirement PPTC Q1. Would you like our proposal to be shipped or do you prefer an electronic submission?

Garage Door Monitor Model 829LM

Logitech Speaker System Z553 Setup Guide Guide d installation

Quick Installation Guide TEW-AO12O

3615 SELFIE. HOW-TO / GUIDE D'UTILISATION

Judge Group: P Title: Quel est meilleur: le compost ou le fertilisant chimique? Student(s): Emma O'Shea Grade: 6

Archived Content. Contenu archivé

72" STORAGE SHELF OR WORKBENCH ÉTAGERÈ DE RANGEMENT OU ETABLI DE 72 PO

JSIam Introduction talk. Philippe Gradt. Grenoble, March 6th 2015

Laboratory accredited by the French Home Office (official gazette date February 5 th, 1959, modified) Valid five years from August 27 th, 2013

FO-FDHB6-1 Central Heat Blower Kit for Onyx, Opel and Delta

Propriétés de la matière. Material properties. Sonde de pression Pressure probe. Ref : Français p 1. English p 3.

Frequently Asked Questions

Editing and managing Systems engineering processes at Snecma

MONTREAL NOTICE DE MONTAGE. Réf Carport une place à toit plat 298 x 500 cm. Charge tolérée (neige) : 100 kg/m2 Hauteur utile : 235 cm

Quick start guide. HTL1170B

Le No.1 de l économie d énergie pour patinoires.

Free filter reminders! Sign up online at: santevia.com/filterease. need help? Contact Santevia!

DOCUMENTATION - FRANCAIS... 2

Gestion des prestations Volontaire

SERVEUR DÉDIÉ DOCUMENTATION

Cedric Dumoulin (C) The Java EE 7 Tutorial

Module Title: French 4

POLICY: FREE MILK PROGRAM CODE: CS-4

calls.paris-neuroscience.fr Tutoriel pour Candidatures en ligne *** Online Applications Tutorial

33 inch open & closed storage Rangement à espace fermé et ouvert de 33po (83.7cm) 33 pulgadas almacenaje abierto y cerra

À noter, s il vous plaît : Ne pas utiliser de l alcool à friction. Il contient un hydratant et n est pas convenable pour nettoyer des cloisons.

Lesson Plan Physical Descriptions. belle vieille grande petite grosse laide mignonne jolie. beau vieux grand petit gros laid mignon

Comfort Duett. TV-kit. USA: English/Français/Español. Comfort Duett

Procédure d installation de la Sauvegarde de Windows Server

Vanilla : Virtual Box

Micro-ordinateurs, informations, idées, trucs et astuces utiliser le Bureau à distance

Utiliser un proxy sous linux

Once the installation is complete, you can delete the temporary Zip files..

PACKZ System Requirements. Version: Version: Copyright 2015, PACKZ Software GmbH. 1

Installation Instructions La section française commence après la section anglaise

LOGICIEL D'ADMINISTRATION POUR E4000 & G4000 MANAGEMENT SOFTWARE FOR E4000 & G4000

Panneau d alimentation de Store Cellulaire

Monopoint / Kit applique serrure EL Série 9560

lundi 3 août 2009 Choose your language What is Document Connection for Mac? Communautés Numériques L informatique à la portée du Grand Public

Z-Axis Compliance Device Compliance en z

NOT SHOWN: Installation Guide and Wi-Fi Setup Card for the customer LED. Test Button OVERVIEW

Le Cloud Computing est-il l ennemi de la Sécurité?

Le passé composé. C'est le passé! Tout ça c'est du passé! That's the past! All that's in the past!

Dishwasher Lave-vaisselle

Spécial Catégorie 6 Patch Cords

If the corporation is or intends to become a registered charity as defined in the Income Tax Act, a copy of these documents must be sent to:

XtremWeb-HEP Interconnecting jobs over DG. Virtualization over DG. Oleg Lodygensky Laboratoire de l Accélérateur Linéaire

APPENDIX 2. Provisions to be included in the contract between the Provider and the. Holder

Mesure chimique. Chemical measurement. Sonde de température Pt 1000 Inox Pt 1000 stainless steel. Ref : Français p 1.

Sécurité relative aux sièges auto et aux rehausseurs

FCM 2015 ANNUAL CONFERENCE AND TRADE SHOW Terms and Conditions for Delegates and Companions Shaw Convention Centre, Edmonton, AB June 5 8, 2015

McGILL UNIVERSITY MARTLET CLASSIC UNIVERSITE McGILL CLASSIQUE MARTLET

Installation et Guide de programmation EMTouch clavier pêne dormant serrures

Using a Walker. 2. Move your injured or weak leg toward the walker first. If you have had surgery on both legs, use either leg to begin walking.

Transcription:

INSTALLATION INSTRUCTIONS PVSDS1-1 DEEP SHROUD KIT FOR USE ON: PVS(18,35)(N,P) INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE. Tools Needed: 5/16 Nut Driver 10 + or Socket with Extension Masking or Painter s Tape Drill Masonry Drill Bit Standard Flat Screwdriver Phillips Screwdriver Pliers Level Carton Contents: PART NUMBER DESCRIPTION QTY 31557 Deep Rear Shroud 1 31556 Pipe Stop Bracket 1 32179 Vent Transition Box, Deep Shroud 1 32326 Flue Support Bracket 1 R11567 Intake Connector Gasket 1 R11737 Hose Clamp 1 R3580 #8-18 x 1/2 Phillips Truss Head Screws 6 32642 1 x 1-1/2 White Fiberfrax Spacer 1 Installation 1. Remove the four #10 x 1/2 hex-head screws securing the standard rear shroud to the wall furnace and remove the rear shroud. Discard the standard rear shroud. 2. Attach the deep rear shroud to the wall furnace using the same four #10 x 1/2 hex-head screws removed in step 1. 3. Move the wall furnace into position against the wall, ensure the wall furnace is level. Adjust the legs on the bottom of the wall furnace if necessary. See Figure 1. Figure 1 WARNING The deep rear shroud is for use in floor mounted installations ONLY! DO NOT use the Deep Rear Shroud kit for mounting the wall furnace in an off the floor, wall mounted installation. If the wall furnace needs to be installed above floor level, as in a garage, an elevated platform will need to be constructed. Note for Garage Installations: The wall furnace must be raised 15-1/2 off of the floor on a platform to meet the 18 minimum off the floor required. 37848-0-0117 Page 1

4. Use masking or painter s tape to mark the location of the two top corners of the deep shroud against the wall. See Figure 2. 7. Determine flue pipe direction (left, right, or up) and remove the corresponding knock out. If installing the wall furnace in a direct vent configuration, remove both knock outs. See Figure 4. Figure 2 5. Move the wall furnace away from the wall. Remove the four #10 x 1/2 hex-head screws securing the deep shroud to the wall furnace and remove the deep shroud. 6, Place the deep shroud back into position against the wall and mark the mounting hole locations. See Figure 3. Drill the proper sized holes for the field supplied anchors. The mounting holes are sized to accommodate 3/16, 1/4, or 3/8 diameter anchors. Figure 4 8. Install the flue support bracket using two #8-18 x 1/2 Phillips head screws provided. See Figure 5. Figure 5 Figure 3 Page 2 37848-0-0117

9. If installing the wall furnace in a direct-vent configuration, assemble the pipe stop bracket to the inside of the air box and install the blue intake connector gasket to the vent transition box. Attach the vent transition box to the rear shroud using two #8-18 x 1/2 Phillips head screws provided. Make sure that the vent transition box opening is aligned with the knock out. See Figure 6. 13. Secure the 90 degree elbow inside of the deep shroud to the flue support bracket using the hose clamp provided. See Figures 8 and 9. Figure 8 NOTE ORIENTATION OF BRACKET. Figure 6 10. Secure the deep shroud in place on the wall using four field-supplied anchors. See Figure 7. Figure 9 Figure 7 11. Install the gas supply line to the wall furnace following the wall furnace s installation instructions. 12. Refer to the venting section of the wall furnace s installation instructions and run the vent pipe to the rear shroud. Make sure that the flue terminates 1 1/2 from the end of the support bracket. See Figure 8. For PVC a short piece of pipe will need to be used as an extension, the Poly-Pro elbow no extension will be needed. If using Poly-Pro piping, place the white 1 x 1-1/8 pad provided between the elbow and the flue support bracket prior to installing and tightening the hose clamp. See Figure 9. 14. If Installing the wall furnace in a direct-vent configuration, insert the intake air pipe through the shroud and into the vent transition box. Make sure that the pipe is fully up against the pipe stop bracket. 15. Install condensation drain and secure the wall furnace to the deep shroud following the venting section of the installation instructions provide with the wall furnace. 37848-0-0117 Page 3

Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 4 37848-0-0117

INSTRUCTIONS D INSTALLATION TROUSSE DE CAPOT PROFOND PVSDS1-1 Outils requis : Tournevis à douille 5/16 po d au moins 10 po ou douille 5/16 po avec rallonge Ruban cache Perceuse Foret de maçonnerie Tournevis à lame plate standard Tournevis Phillips Pince Niveau Contenu de l emballage À UTILISER SUR : PVS(18,35)(N,P) LES INSTRUCTIONS DOIVENT ÊTRE LAISSÉES AU PROPRIÉTAIRE POUR CONSULTATION ULTÉRIEURE. NUMÉRO DE PIÈCE DESCRIPTION QTÉ 31557 Capot arrière profond 1 31556 Support d arrêt de tuyau 1 32179 Caisson de transition, capot profond 1 32326 Support de tuyau de fumée 1 R11567 Joint du connecteur d admission 1 R11737 Collier de serrage 1 R3580 Vis Phillips à tête bombée n o 8-18 x 1/2 po 6 32642 Espaceur Fiberfrax blanc 1 x 1 1/2 po 1 Installation 1. Enlever les quatre vis à tête hexagonale n o 10 x 1/2 po qui fixent le capot arrière standard sur l appareil de chauffage mural et enlever le capot arrière. Se départir du capot arrière standard. 2. Fixer le capot arrière profond à l appareil de chauffage en utilisant les vis à tête hexagonale n o 10 x 1/2 po enlevées à l étape 1. 3. Placer l appareil de chauffage mural en position contre le mur, en s assurant qu il est de niveau. Régler les pieds dans le bas de l appareil si nécessaire. Figure 1 AVERTISSEMENT Le capot profond arrière est destiné à une utilisation sur des installations montées sur plancher SEULEMENT! N UTILISEZ PAS la trousse de capot arrière profond pour monter l appareil de chauffage mural sans qu il ne repose sur le plancher. Si l appareil de chauffage mural doit être installé au-dessus du niveau du plancher, par exemple dans un garage, une plateforme surélevée doit être construite. Remarque pour les installations dans un garage : L appareil de chauffage mural doit être élevé à 15 1/2 po (394 mm) du plancher sur une plateforme pour satisfaire la distance minimale requise de 18 po (457 mm) depuis le plancher. 37848-0-0117 Page 1

4. Utiliser du ruban-cache pour marquer la position des deux coins supérieurs du capot profond sur le mur. Voir Figure 2. 7. Déterminer la direction du tuyau de fumée (gauche, droite ou haut) et enlever la débouchure correspondante. Pour une installation en configuration à ventilation directe, enlever les deux débouchures. Voir Figure 4. Figure 2 5. Déplacer l appareil à l écart du mur. Enlever les quatre vis à tête hexagonale n o 10 x 1/2 po qui fixent le capot profond sur l appareil de chauffage mural et enlever le capot profond. 6. Replacer le capot profond en position contre le mur et marquer les positions des trous de montage. Voir Figure 3. Percer des trous de diamètre approprié pour les ancrages achetés localement. Les trous de montage devront recevoir des ancrages de diamètres 3/16, 1/4 ou 3/8 po. Figure 4 8. Installer le support de tuyau de cheminée à l aide des deux vis Phillips à tête hexagonale n o 8-18 x 1/2 fournies. Voir Figure 5. Figure 5 Figure 3 Page 2 37848-0-0117

9. Pour une installation en configuration à ventilation directe, monter le support d arrêt de tuyau sur l intérieur du caisson d air et poser le joint du connecteur d admission bleu sur le caisson de transition. Fixer le caisson de transition sur le capot arrière à l aide des deux vis à tête Phillips n o 8-18 x 1/2 fournies. S assurer que l orifice du caisson de transition est aligné sur la débouchure. Voir Figure 6. 13. Fixer le coude à angle droit à l intérieur du capot profond sur le support de tuyau de fumée à l aide du collier de serrage fourni. Voir les Figures 8 et 9. Figure 8 NOTER ORIENTATION L ORIENTATION DU OF BRACKET. SUPPORT Figure 6 10. Fixer le capot profond en place sur le mur à l aide des quatre ancrages achetés localement. Voir Figure 7. COUSSINET BLANC Figure 9 Figure 7 11. Installer la conduite d alimentation en gaz sur l appareil de chauffage mural en suivant les instructions d installation de l appareil. 12. Se reporter à la section sur la ventilation dans les instructions d installation de l appareil de chauffage et acheminer le tuyau de ventilation jusqu au capot arrière. S assurer que le tuyau de fumée se termine à 1 1/2 po (38 mm) de l extrémité du support. Voir Figure 8. Pour le PVC, un petit segment de tuyau devra servir de rallonge; dans le cas du coude Poly-Pro aucune rallonge n est nécessaire. Dans le cas d une tuyauterie Poly-Pro, placer le coussinet blanc de 1 x 1 1/8 po fourni entre le coude et le support de tuyau de fumée avant d installer et de serrer le collier de serrage de tuyau. Voir Figure 9. 14. Pour une installation de l appareil de chauffage mural dans une configuration à ventilation directe, insérer le tuyau d admission d air à travers le capot et dans le caisson de transition. S assurer que le tuyau est bien appuyé contre le support d arrêt de tuyau. 15. Installer le drain de condensation et fixer l appareil de chauffage sur le capot profond en se reportant à la section sur la ventilation des instructions d installation fournies avec l appareil. 37848-0-0117 Page 3

Empire Comfort Systems Inc. Belleville, IL Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d entretien ou de réparation, veuillez contacter votre revendeur. www.empirecomfort.com Page 4 37848-0-0117